MEMORY RECORDER/ANALYZER

Similar documents
EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

EDX-5000A. Memory Recorder/Analyzer. High-speed sampling at 200 khz per 32 channels Simultaneous recording of video with a high-speed camera

DM3100V2 Specifications

Dynamic Strain Amplifiers

WR300 SERIES. Direct Recording. Multi-Function. Direct Operation. Easy PC Connection. Thermal Arraycorders

WR300 SERIES. Direct Recording Chart, Internal Memory, 40GB HDD. Multi-Function Voltage / Temperature / Strain / Frequency

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

Signal Input and Trigger

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

Function Modules GL7- DISP GL7 - SSD GL7 - DCO. Datasheet. Function Modules. Voltage Output Module

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Fast 10-ms Sampling Up to 600 Channels Data Logging. MEMORY HiLOGGER 8423

Vibration amplifier Model 6634C

Analog Arts SF990 SF880 SF830 Product Specifications

RIGOL Data Sheet. DG2000 Series Function/Arbitrary Waveform Generator DG2041A, DG2021A. Product Overview. Main Features.

SDM3045X Digital Multimeter. DataSheet

Vector Network Analyzers ZVB

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

NEW! Transient Data Acquisition. Stand alone. Compact. Powerful.

Analog Arts SF900 SF650 SF610 Product Specifications

SDM3045X Digital Multimeter. DataSheet

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

Tablet Oscilloscope Data Sheet

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

Fast 10-ms Sampling Up to 600 Channels Data Logging. Data Logger

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Moku:Lab. Specifications INSTRUMENTS. Moku:Lab, rev

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

Portable Multi-Channel Recorder Model DAS240-BAT

Data Sheet. Function/Arbitrary Waveform Generator. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

SDM3055 Digital Multimeter. DataSheet

Signal Conditioning Amplifier

MEMORY HiCORDER Recorders

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

Advanced Test Equipment Rentals ATEC (2832)

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

Audio Analyzer R&S UPV. Preliminary Specifications

World-Class Accuracy & Measurement Range (40 Conventional Models)

U1604A Handheld Oscilloscopes, 40 MHz

IMPEDANCE ANALYZER IM3570

Omniace RA2300MKII/RA2300MKII-S

Telemetrie-Messtechnik Schnorrenberg

R3131A. Advanced Test Equipment Rentals ATEC (2832) A personal spectrum analyzer for use in diverse applications R3131A

DT9838. Strain- and Bridge-Based Measurement Module. Key Features: Bridge Configurations. Analog Input Features

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

10-CH Digital Thermometer Module

ATA-2001 Analog LVDT/RVDT Signal Conditioner with digital calibration

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

Agilent ESA-L Series Spectrum Analyzers

Low Noise Variable Gain Low Frequency Voltage Amplifier

SC-4/M User manual 4-channel measuring amplifier

4 K to 512 K words (2 n, n = 12 to 19) or 2 to 10,000 control points (linear interpolation between control points)

Telemetrie-Messtechnik Schnorrenberg

Agilent Technologies 3000 Series Oscilloscopes

Rugged, Professional and Ready for the Field. Capture high- to low-voltage signals in a single device. MEMORY HiCORDER MR8880

1510A PRECISION SIGNAL SIMULATOR

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

15. Specifications WF1947/WF

DP2000 ORDERING GUIDE To Order MODEL NO.

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

KMT - Kraus Messtechnik GmbH

Digital Phosphor Oscilloscopes

10-CH, 100 ks/s Digitizer Module

Digital Multimeters R6871E/R6871E-DC. R6871E/R6871E-DC Digital Multimeters. High-Speed and Low-Price DMM with a Sampling Rate of 2,000 Times/Second

Spectrum Analyzers 2680 Series Features & benefits

NI 6143 Specifications

High-speed programmable attenuator MAT800

DG4000 Series Waveform Generators

SCXI 8-Channel Isolated Analog Input Modules

DG5000 series Waveform Generators

Kistler LabAmp for DynoWare

DC Resistance Meters 2840 Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Agilent Technologies 3000 Series Oscilloscopes

Rugged, Professional and Ready for the Field MR MEMORY HiCORDER. Capture high- to low-voltage signals in a single device

SPECIFICATIONS Digital Indicator 1. General

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

Arbitrary/Function Generator AFG1000 Series Datasheet

Function/Arbitrary Waveform Generator

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

Part Numbering System

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

RS-232C. 3801, 3802 (High-accuracy) 3803, 3804, 3805 (Economically priced) & DIGITAL HiTESTER. Support efficient data collection.

Transcription:

NEW MEMORY RECORDER/ANALYZER By the Specialist in Stress Measurement

All-in-one All-purpose Instrument From Measurement to Monitoring, Recording and Processing The EDX-2000A is a general-purpose, expandable all-in-one instrument that can measure, monitor, record and process signals from various sensors. It has 2 types, 32-channel type and 64-channel type. The EDX-2000A starts measuring according to preset conditions and can simultaneously sample signals of 16 channels at 200 khz (32 channels at 100 khz). A built-in large-capacity hard disk enables storage of 32-channel data with 10 khz sampling frequency for approximately 13 hours. The recorded and processed data can easily be transferred online or offline to the PC. Furthermore, the EDX-2000A enables recording of voice memos, analog reproduction of recorded data with an optional DA card, and recording of CAN data with an optional CAN card.

FEATURES Processes data for FFT or frequency analysis, etc. during measurement in progress, thereby enabling monitoring of input signals and checking of processed results in real time. All-in-one measuring instrument with conditioner cards (optional) built-in. A battery is built in to safeguard against instantaneous power failure. Built-in large capacity hard disk enables storage of 32-channel data with 10 khz sampling frequency for approximately 13 hours. Voice memos can be recorded together with measured data. An optional CAN card enables CAN data recording. An optional DA card enables reproduction of analog data. FFT analysis, frequency analysis, arithmetical operations, etc. are possible. Maximum sampling frequency is 200 khz, and simultaneous sampling of 16 channels is possible even at such a high frequency. Interactive operation makes measuring tasks easy and speedy. Easy-to-handle ATA card or hard disk card is optionally available for transferring offline data to the PC. Connecting LAN interface between the EDS-2000A and PC allows online data transfer to the PC. DAS-100A Data Analysis Software is optionally available.

Various display functions satisfy demanding needs by presenting m Displays during Measurement X-Y Graph 1 Graph Bar Graph (All Channels) Display of Various Divisions for Every Channel List of Numeric Values Displays of Data Analyzed Simultaneously with Measurement Simultaneous FFT Analysis during Measurement Simultaneous Histogram Analysis during Measurement

asured values, graphs or processed data in real time. Condition Setting Displays Data Reproduction Display Channel Condition (Channel Name) Channel Condition (Unit) Reproduced Data Measuring Condition Setting Setting for Simultaneous Histogram Processing Analysis Displays Environment Setting Display FFT Analysis Differential/Integrate Condition Setting Environment Setting Arithmetical Operations Histogram Analysis File Displays File Management File Format Conversion

Specifications General Models Model Max. Analog Input Channels Note: Number of conditioner slots. Number of Slots Number of Input Channels EDX-2000A-32: Max. 32 EDX-2000A-64: Max. 64 Number of channels: The number of channels of built-in conditioner cards x the number of slots Analog Input: Refer to specifications of built-in cards Digital Input: 16 bits, TTL level, contact input Voice Input: 1 channel (voice memos can be recorded together with measured data) Number of Output Channels: Refer to specifications of DA card) Sampling Method: Simultaneous sampling of all channels Frequency: (1-2-5 system) 1 Hz to 200 khz for up to 16-channel data recording 1 Hz to 100 khz for up to 32-channel data recording 1 Hz to 50 khz for up to 64-channel data recording 1 Hz to 10 khz for simultaneous data processing (refer to software specifications) Data Recording Capacity: 30 GB or more Display: 10.4-inch color LCD (for setting various conditions and data monitoring in graphic and numeric formats) Operation: Through panel keys and external keyboard External Control Signal: External clock input Interface Ports Keyboard: Mini DIN 6-pin port for connection to English keyboard; conforming to 106 External Display: 15-pin port (VGA) for monitor display PCMCIA: Conforming to PCMCIA Ver. 4.2. Compatible with optional ATA card or hard disk card for collecting recorded data LAN: For transferring data to the PC (10BASE-T/100BASE-TX) Power Requirements: 100 to 120 VAC/190 to 240 VAC, 10 to 30 VDC; Power consumption with the CDV-40A card mounted to all channels and with full load Power source EDX-2000A-32 EDX-2000A-64 100 VAC, 50 Hz 2.3 A 2.8 A 200 VAC, 50 Hz 1.3 A 1.5 A 12 VDC 8.0 A 9.4 A 24 VDC 3.8 A 4.6 A Battery is built in to safeguard against instantaneous power failure. Operating Temperature Range: 0 to 40 C Operating Humidity Range: 20 to 80%RH (noncondensing) Storage Temperature Range: 20 to 60 C Vibration Resistance: 29.42 m/s 2 (3 G), 5 to 55 Hz (when operating) 49.03 m/s 2 (5 G), 5 to 55 Hz (when not operating) Shock Resistance: 196.1 m/s 2 (20 G)/11 ms Dimensions & Weight EDX-2000A-32: 350(W) x 132(H) x 300(D) mm (excluding protrusions), approx. 12 kg (with 2 units of 8-channel CDV-40A mounted) EDX-2000A-64: 430(W) x 156(H) x 300(D) mm (excluding protrusions), approx. 13 kg (with 2 units of 8-channel CDV-40A mounted) Standard Accessories Digital input card DIB-40A (built into the main body), AC power cable P-18 (with 3P-2P conversion adapter CM-33), DC power cable, Instruction Manual Options Dummy panel EDX2000-DUMMY Remote control unit RCU-40A Synchronous cable N-94 8-channel sensor input cables U-40, etc. 8-channel bridge box Data analysis software DAS-100A Remote Control Unit RCU-40A Control Functions REC: To start data recording PAUSE: To pause data recording STOP: To stop data recording VOICE MEMO: To record voice memo LED Displays: REC, PAUSE, VOICE MEMO Cable Length: Approx. 1.5m Built-in Cards Strain/Voltage Measuring Card CDV-40A Item Number of Input Channels Input Type Input Resistance Coupling Applicable Gage Factor Excitation Voltage Balance Adjustment Range Measuring Range Range Accuracy Nonlinearity Frequency Response Range Lowpass Filter Highpass Filter (DC cut) Resolution of A-D Conversion Strain Meas. 8 (centralized connector) Balanced input Approx. (10 MΩ + 10MΩ) DC/AC (DC cut) 2.00 2.00 VDC ±2% (120 to 1k Ω) Bridge resistance ±2.4% (±12000 µm/m) 500, 1k, 2k, 5k, 10k, 20k, 50k µm/m, OFF ±0.2% FS with each range ±0.1% FS Voltage Meas. Unbalanced input Approx. 1 MΩ DC coupling: DC to 50 khz, dev. +1 db/ 3 db AC coupling: 0.2, 1 Hz to 50 khz Transfer characteristics: 2nd order Butterworth Cutoff frequency: 8 steps of 10, 30, 100, 300, 1k, 3k, 10 khz and FLAT Cuttoff amplitude: 3 ±1 db Attenuation: 12 db ±1 db/oct Cutoff frequency: 0.2 Hz, 1 Hz Attenuation: 6 db/oct 16 bits Options: Voltage conversion adaptor FV-1A, 8-channel input cables U-38 to U-48 (N81 to N85 should be used in combination for remote-sensing transducers. Dynamic Strain Amplifier Card DPM-42A For strain gages and strain gage transducers. The card uses carrier for bridge excitation and thus, it is suitable for measurement of low level strain. The input and output are isolated. Applicable Sensors: Strain gages, strain gage transducers Number of Measuring Channels: 4 Frequency Response Range: DC to 5 khz (deviation: ±10%) Carrier Frequency: 12 khz Applicable Bridge Resistance: 120 to 1000 Ω Gage Factor: 2.00 fixed Bridge Excitation: 2 VAC rms Balance Adjustment Range Resistance: ±2.4% (±12000 µm/m) Capacitance: 2000 pf Balance Adjustment Method Resistance: True electron auto-balancing method Capacitance: CST (self-tracking) method Range: 200, 500, 1000, 2000, 5000, 10000, 20000 µm/m and OFF (8 steps) Calibration: ±100% and ±50% in each range Nonlinearity: Within ±0.2% FS Lowpass Filter 2nd order Butterworth Cutoff frequency: 10, 30, 100, 300, 1k Hz and FLAT (6 steps) Cutoff accuracy: 3 ±1 db Attenuation: 12 db/oct Resolution: 16 bits Additional Function: For input check by inserting a resistor to a side of a bridge Monitor Output: ±5 V Accuracy: Within ±0.5% (±FS) Nonlinearity: Within ±0.5% FS Withstand Voltage: 250 VAC for 1 minute between input and output Thermocouple Card CTA-40A For temperature measurement with 2 types of thermocouples, K (CA) and T (CC). The card has the input/output isolated. Applicable Sensors: Thermocouples K (CA) and T (CC) Number of Input Channels: 8 Thermocouple Resistance: 200 Ω or less with burnout ON 1000 Ω or less with burnout OFF Measuring Range: 6 steps including OFF K1230: 200 to 1230 C T400: 200 to 400 C K480: 200 to 480 C T210: 200 to 210 C K240: 200 to 240 C System Accuracy: Within ±(0.5% rdg + 1) C at an ambient temperature of 20 ±3 C Within ±(0.5% rdg + 2) C in a temperature range of 0 to 40 C Calibration: 100%, 50% in each range and absolute 0 C Frequency Response Range: DC to 10 Hz Resolution: 16 bits Burnout: Built-in burnout display ON/OFF Note: If the thermocouple resistance is high, accurate measurement is made possible by turning the burnout function OFF. 0.1, 0.2, 0.5, 1, 2, 5, 10 V, OFF

Monitor Output: 5 V Accuracy: Within ±0.5% (+FS) Nonlinearity: Within ±0.5% FS Insulation Resistance: 50 MΩ or more (500 VDC) between input and output and between channels F/V Converter Card CFV-40A For measurement of input pulse frequency. This card has a power supply for sensors and the input/output isolated. Applicable Sensors: AC signal output sensors Number of Input Channels: 4 Input Signals: AC (zero-cross), TTL level (including open collector signals) Input Voltage Range: ±(0.5 V to 50 V) with large hysteresis ±(0.1 V to 50 V) with small hysteresis Measuring Range: 9 steps of 50, 100, 500, 1k, 2k, 5k, 10k, 20k Hz and OFF Accuracy: Within ±0.1% FS Calibration: 100%, 50% (added) in each range and 0% (absolute) Response Time: 10 µs or less with pulse input continued 2 cycles of input frequency + 50 µs or less with pulse input discontinued Resolution: 16 bits Sensor Power Supply: 12 VDC within ±10% (50 ma or less for each channel) Monitor Output: 5 V Accuracy: Within ±0.5% (+FS) Nonlinearity: Within ±0.1% FS Insulation Resistance: 50 MΩ or more (500 VDC) between input and output and between channels Remarks: Up to two F/V converter cards can be mounted to the 32-channel type EDX-2000A. For the 64-channel type, when two F/V converter cards are mounted, up to 4 other cards, and when one F/V converter card is mounted, up to 6 other cards can be mounted. Options: Voltage conversion adaptor FV-1A. 8-channel input cables U-38 to U-48 CAN Card CAN-40A For measurement of data frames on the controller area network (CAN). Maximum 16 kinds of data frames are simultaneously recorded with usual analog data. Number of CAN Ports: 1 Connectors: D-sub 9-pin for high and low speed CANs Compatible CAN Version: Bosch 2.0B (conforms to ISO 11898) Switchable between high-speed CAN and low-speed CAN Number of Measured IDs: Max. 16 CAN Controler Operating Clock: 40 MHz, 32 MHz Transmission Speed: 1000/800/500/250/125/100/83.3/62.5/50/33.3/25/20/10 kbps with high-speed CAN 125/100/83.3/62.5/50/33.3/25/20/10 kbps with low-speed CAN Setting Conditions for Communication: Sampling point, number of sampling times, re-synchronization jump width Measuring Channel Conditions: Start bit, bit length, data type, CAL coefficient (conditions to convert the extracted CAN data to physical values) Displays: Numeric display, frame display, graphic display together with analog data Remarks: Only one CAN card can be mounted to the last slot of the EDX-2000A. The maximum sampling frequency is 10 khz when CAN data is measured. Charge Amplifier Card CCA-40A For piezoelectric accelerometers. Applicable Sensors: Voltage-output piezoelectric accelerometers with built-in amplifier Number of Measuring Channels: 8 Sensor Power Supply: Constant-current 4 ma DA Card DAC-40A For analog reproduction of the data recorded with EDX-2000A. Number of Output Channels: 8 Connectors OUTPUT 1: BNC connector outputs data of a selected channel. OUTPUT 2: D-sub 9-pin connector outputs 8-channel data. Output Voltage: ±5 V FS (load resistance: 5 kω or more) Accuracy: Within ±0.15% FS Nonlinearity: Within ±0.05% FS Setting Conditions for D-A Conversion Reproduction rate: 1 to 10 khz (selected from internal sampling clock) Simultaneous playback of voice data: Yes/No Number of reproducing times: 1 to 1000 or infinite Set recording data channels, full scale of output and shift level Reproduce Data: All measured data and data in a display range Calibration: Absolute values of ±50% and ±100% of full scale Software Specifications Measuring Condition Setting Measuring Channel Conditions: Measuring channel, range, highpass filter, lowpass filter, CAL coefficient, offset, unit, channel name Measuring Mode Manual: Data recording through panel keys or remote-control unit Trigger: Automatic data recording based on trigger channel and trigger condition Interval: Automatic data recording at preset time intervals Sampling Frequency: Set a desired sampling frequency. Number of Recording Data: 2 to 2,000,000,000 (for 1-channel measurement with remaining capacity of 4 GB) 2 to hard disk remaining capacity (Sampling frequency of 1 to 10,000 Hz) 2 to 2,000,000,000 (Sampling frequency of 16,384 to 200,000 Hz) Test Information: Test title, date/time, comment, items/contents Saving and Loading of Measuring Conditions Measurement and Data Recording Monitor Display Monitor Modes Numeric: Measured values are digitally indicated. Time-series Graph: 1, 2 or 4 time-series graphs are displayed on a single screen page. Bar Graph: Values of all channels (max. 64) are displayed in bar graph. X-Y Graph: 1 or 2 graphs are displayed on a single screen page. Each graph may be traced as a relative graph with 4 channels. Analysis during Data Recording Types of Simyltaneous Analysis: FFT analysis, histogram analysis Either one can be selected during monitoring or recording. FFT Analysis Types of FFT Analysis: Linear spectrum, power spectrum, cross spectrum, auto-correlation, cross-correlation Number of Analyzed Data: 256, 512, 1024, 2048 Window Functions: OFF (rectangular window), hanning, hamming, Fejer, Blackman, Gaussian Histogram Analysis Types of Histogram Analysis: Max/Min, Peak/Valley, 1D rainflow, 2D rainflow Number of Slices: 1D: 16 (±8), 32 (±16), 64 (±32), 128 (±64), 256 (±128) 2D: 16 (±8), 32 (±16) Hysteresis: 2 to preset number of slices Offset: Can be set for the Max/Min analysis method. Data Reproduction Graphic Display Types of Graph Time-series Graph: 1, 2 or 4 graphs on a single screen page X-Y Graph: 1 graph is displayed on a single screen page; the graph may be traced as a relative graph with 4 channels. All Channels Graph: Max. 16 channels/screen page Graphic Display Conditions: Display channel(s), scale, number of display data, auxiliary line, etc. Graph Control: Scroll, cursor operation and value indication, zoom in/zoom out, all data display/magnification, playback of voice memos, etc. Saving and Loading of Display Conditions Data File Editing Data: Revising and editing recorded data (the number of data which can be edited at a time is limited) Header: Revising the header information (date/time of data recording, CAL coefficient, offset, unit, comment, channel name) File Saving: Saving the edited file as a different file Cutting: Saving a desired section of the recorded data file as a different file Conversion to ASCII: Converting the recorded data file into ASCII (CSV format) file Statistic Processing: Display and saving of maximum, minimum, average and standard deviation of the recorded data Analog Output: Reproducing already recorded analog output data to the DA card (optional)

Analysis Arithmetical Operations Arithmetical operations are performed between desired channels in max. 2 data files and the results are saved in a designated file. Setting Items Calculating File Name(s): Designate 1 (A) or 2 (A and B) data files. For 2 data files, the sampling frequency should be the same. File Name of Calculated Results: Designate the file name to save results of arithmetical operations. Operating Channels: Analog channels only (A01 to A64, B01 to B64) e.g. "A06" indicates channel 6 of file A and "B28," channel 28 of file B. Channels of Calculated Results: Max. 32 (C01 to C32) (C ; indicates the expression description channel.) e.g. C06 = (expression) makes the operated result saved in channel C06. Expression: Designate expression f ( ) in C = f (A, B ). The expression should be within 60 digits. The number of expressions (channels of calculated result) available for setting is maximum 192. Unit: A desired engineering unit can be designated for the calculated result. Channel Name: Comment on the channel of calculated result Operators and Expression Operators: +,,, /, trigonometric function, logarithmic function, exponential function, rosette function Remarks: Parenthesis (up to level 3) and variable cannot be used. "+" and " " are also effective as signs (e.g. 5.7, A15). Any calculated result (channel) cannot be used for any expression of other channel of calculated result. Also, any recursive processing is not possible. (e.g. C10 = C01 + C02, C12 = C12 + 3,1415 cannot be used.) Saving and Loading of Calculating Conditions FFT Analysis FFT analysis is performed on data of desired channel(s) of recorded data file and analyzed results are saved in a designated file. The results are graphically displayed for confirmaion. Types of FFT Analysis: Linear spectrum, power spectrum, cross spectrum, auto-correlation, cross-correlation Analysis Conditions Analyzing Channel(s): 1 or 2 (depends on type of FFT) Filter: Lowpass filter can be applied for pre-processing. Integration: Data can be integrated 1 or 2 times for pre-processing Number of Analyzed Data: 256, 512, 1024, 2048, 4096, 8192, 16384, 32768 Window Function: OFF (rectangular window), hanning, hamming, Fejer, Blackman, Gaussian Averaging Times and Number of Shift Data: Averaging of FFT results (1 to 99 times) and number of shift data (1 to 9999) Analysis Start Point: Designate the starting point of analysis on the target data. Analysis Result File: Analyzed results are saved together with the target time-series data. Analysis Result Graph: Target time-series data and analyzed results are graphically displayed. Cursor display and zoomin/zoom-out of X and Y axes are possible. Saving and Loadding of Analysis Conditions Histogram Analysis Histogram analysis is performed on recorded data and analyzed results are saved in a designated file. The results can be displayed on graph or table. Setting Items Target Channel: Designate the histogram analysis channel. Types of Histogram Analysis: A) Peak/valley B) Max/Min C) 1D rainflow D) 2D rainflow E) Amplitude F) 1D time at level G) Complex: 1D rainflow + Peak/valley H) Complex: 1D rainflow + Max/Min Number of Slices 1D types (abovementioned A, B, C, E, F, G and H ): 10 (±5) to 256 (±128) 2D type (abovementioned D): 10 to 50 (even number) Slice Width: Designate the width of a slice with physical value. Hysteresis: Set the number of masking slices in a range of 0 to the preset number of slices. Offset: Designate an offset value with physical value for max/min analysis. Analyzing File: Recorded data file or file of results obtained through arithmetical operations Analysis Result File: File of histogram analysis results Result Display: Table: List of histogram analysis results for every channel Graph: Graph of histogram analysis results for every channel (For 2D type, 3-dimensional graph is displayed) Differentiation/Integration, Filtering and Moving Averaging Number of Differentiation/Integration Times: 1 or 2 selectable Average correction possible for integration Digital Filters: 4th order Butterworth (with cutoff characteristic of 3 db and no phase lag) Highpass filter: FLAT, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 Hz Lowpass filter: FLAT, 10, 20, 50, 100, 200, 500, 1000 Hz (Effective at up to one-half the sampling frequency) Moving Averaging: 1 to 999 times File Management Functions: Copy file, delete file, change file and folder names, sort, create folder, delete, function of converting data in bulk Type of Target File: Condition file, data file, and text file Setting Environment Setting Items: Data recording folder, condition saving foler, date/ time, etc. Dimensions (9) 350 (9) (9) 430 (9) (9) 132 300 (21) (9) 156 300 (21) Specifications are subject to change without notice for improvement. Safety precautions Be sure to observe the safety precautions given in the instruction manual, in order to ensure correct and safe operation Reliability through integration Manufacturer, s Representative KYOWA ELECTRONIC INSTRUMENTS CO., LTD. Overseas Department: 1-22-14, Toranomon, Minato-ku, Tokyo 105-0001, Japan Tel: (03) 3502-3553 Fax: (03) 3502-3678 http://www.kyowa-ei.co.jp e-mail: overseas@kyowa-ei.co.jp Cat. No. 603B-U26 Printed in Japan on Recycled Paper 01/05 ocs