Omnicure S1500 UV Spot Curing System. 122, Chemin de la Cavée Orgeval Tèl :

Similar documents
OmniCure Setting the Standard for Precision Assembly UV Curing

OmniCure Setting the Standard for Precision Assembly UV Bonding

New PCA Accessory for the Q Series DSC Modules

BlueWave MX-150 LED Spot-Curing System High-Intensity Curing System with the Flexibility of Multiple Systems

BlueWave MX-150 LED Spot-Curing System High-Intensity Curing System with the Flexibility of Multiple Systems

EQ CL30 LED Flood 365 / 380 / 405

Worldwide Price List

New: up to mw/cm² LED. bluepoint LED. System-Features. Advantages

Oriel Sol3A Class AAA Solar Simulators

BlueWave MX-275 UV LED Curing System High-Intensity UV LED Flood-Curing System with Line Pattern Emitters

Adhesive curing with the DELOLUX 80 LED lamp. DELOLUX 80 LED Curing Lamp

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

KTP LASER. Photocoagulation System

Uniform surface Led series SFL-UV

lighting your creativity HONEY BADGER 320Ws Digital Flash Instruction Manual

Reliably embed with comfort and speed

Improved Radiometry for LED Arrays

EQUIPMENT. Loctite UV Curing Wand System. # Single Wand # Dual Wand OPERATION MANUAL

idonus UV-LED exposure system for photolithography

Applicable for the following PLC UV Head Controller model: PLC R

Tunable Laser. PZT Cavity Tuning

The use of ultraviolet (UV) energy

Advances in Measuring UV LED Arrays

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Oriel Flood Exposure Sources

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

577 nm: The Preferred Wavelength

IS-3000 SERIES INFRARED SCANNER

The Interfit S1. AC/DC Powered TTL/HSS Flash. Instruction Manual.

Improve asset protection and utilization

STROBOSCOPE, XENON - digital

UV PROCESS SUPPLY, INC. CON-TROL-CURE COMPACT RADIOMETER INSTRUCTION MANUAL PART # M

Influence of the light spectral distribution used in the radiometers calibration

Table 8 Overview light sources

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

Benefits of UV Light Curing...Page 3. Fundamentals of UV Light-Curing...Page 6. Designing a UV Light-Curing Process...Page 7

SUSS MA/BA Gen4 Series COMPACT MASK ALIGNER PLATFORM FOR RESEARCH AND LOW-VOLUME PRODUCTION

Validating a Conveyor Light-Curing Process Ensure Your Light-Curing Process Will Perform Accurately Every Time

illumia Plus Temperature Controlled Light Measurement Systems

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument

Keysight Technologies U5850 Series TrueIR Thermal Imagers

Automation Components, Inc. CURRENT 4-20 MA OUTPUT

Model #2 UVB Midband Ultraviolet Lamp Assembly with Timer

Cornerstone 260 1/4 m Monochromators

Web Coating and Laminating Systems

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Sun 2000 Solar Simulators Cost effective and versatile UV to IR sources

Aristo Archive Information. Aristo VCL4500 Series Dual Lamp Cold Light Head. General Information. Light Head

1510A PRECISION SIGNAL SIMULATOR

For the 50 years of BALCAR, we are pleased to announce a new line of generators, fully compatible with a complete digital workflow process.

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Measuring the Performance of UV LED Light Sources

An Introduction to UV LED Technology. Jennifer Heathcote Integration Technology Limited April 30, 2012

Programmable AC Power Source Model 9801

INSTALLATION AND OPERATING MANUAL

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

6 FT LED Bulb - T8-36W Lumens - UL Listed - Fluorescent T8 LED Replacement/Retrofit Lamp

10 Million Candlepower LED Spotlight - 36 Watt - Pistol Grip Foot Beam Lumens

Headquaters Dr. Hönle AG

EIT Instrument Markets Product Overview

Spotlight 150 and 200 FT-IR Microscopy Systems

Agilent Technologies 3000 Series Oscilloscopes

6 Million Candlepower LED Spotlight - 25 Watt Handheld Hunting Spotlight V DC ' Beam

Additel 875 Series Dry Well Calibrators

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

NOW WITH BROADER TUNING RANGE

True RMS Bench Multimeter 5492B

Compact High Intensity Light Source

Power Supplies 3. SDN-C Compact DIN Rail Series

28 Watt LED Bulb - 4ft T5HO LED Lamp Lumens - Replacement or Upgrade for Fluorescent Lights

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

Optical Inspection Systems

CC1-15: I-V Curve Data Acquisition System Description and features

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

SPECIFICATIONS. Table 2 - Specifications for rack mounted electronics with user controller. Document Number Rev 1

Use of the Photocalorimeter Accessory (PCA) with Tzero DSC

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

The Quality of Light TM. LineLight. Metaphase Technologies Inc. LL040710

Anapurna RTR3200i LED (+ white)

XRP Generators. Overview. Industrial X-Ray. Technology with Passion

Series 48 Air Cooled Laser & UC-2000 Quick Start Guide

The New Standard in Lightfastness Testing

bluephase Licence to cure LED for every use

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

SOLARONIX. Solixon A-1525-V

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

TracQ. Basic Data Acquisition and Spectroscopy Software

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL

XC4e PWM Digital Drive

User guide ProHead Plus

Professional Wide-Format UV Inkjet Printer

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

PAYBACK STARTS NOW INDUSTRIAL LIGHTING PRODUCT CATALOG

Preliminary. LedEngin, Inc. High Radiant Flux Density 400nm Violet LED Emitter LZP-00UA00. Key Features. Typical Applications.

TriVista. Universal Raman Solution

High Radiant Flux Density 400nm Violet LED Emitter LZP-00UA00

STC-205Di. Quick. Specs. For TIG, Plasma and Stick Welding A combo machine for arc welding and plasma cutting

Transcription:

UV Spot Curing System

The OmniCure S1500 delivers power, control and reliability in an extremely cost-effective, affordable system. Powerful 200 Watt Intelli-Lamp with a guaranteed lamp life of 2000 hours Automatic lamp striking with hot strike prevention that will protect lamp life Selectable bandpass filters to customize light wavelengths for specific applications Easy-to-use finger-touch controls with bright LED display

The OmniCure Advantage In Spot Curing Systems Recognized as the global leader in bonding systems for precision assembly with light-cured adhesives, the OmniCure S2000 provides the power, control and repeatability required for high-speed automated manufacturing assembly. Offering a powerful 200 Watt lamp with a guaranteed life of 2000 hours, the OmniCure S2000 also offers Closed-Loop Feedback technology and a flexible PC software interface for computer-controlled operation. When combined with OmniCure s R2000 Radiometer, the OmniCure S2000 s precision and reliability is unmatched. The OmniCure S2000 is also designed to adhere to regulatory validations and is RoHS compliant. Powerful 200 Watt Intelli-Lamp The powerful patented 200 Watt Intelli-Lamp installed in the OmniCure S1500 guarantees an amazing 2000-hour lamp life and a typical lamp life of up to 4,000 hours. Faster curing is achieved with high UVA irradiance of up to 10W/cm2. Intelligent Operation The OmniCure S1500 has a multitude of built-in features that provide greater control, precision and versatility. Features include an adjustable iris, patented Intelli-Lamp technology, selectable bandpass filters, process alarms, and lock out protection, most of which are found only in higher-priced curing systems. The curing system can also be programmed and controlled externally from a PLC using the 15-pin I/O ports. Ease-of-Use With snap-in lamp insertion, finger touch controls, an easy-to-read LED display, process indicators and automatic lamp striking, the OmniCure S1500 is simple to use. Hassle-free snap-in lamp insertion and a low-noise fan improve ongoing operation. OmniCure S1500 Typical Irradiance S1500 R2000 FILTER (nm) IRRADIANCE (W/cm2) 320-500 23 400-500 14.5 320-390 7.3 365 5.9 250-450 19.1 no filter 27.7

FEATURES Faster Shutter Activation Time Modified PLC Level 200W lamp technology with 2000 hour lamp life guarantee Intelli-Lamp Technology to cool lamp and monitor lamp hours Adjustable light output in 1% increments External PC Controlled Lamp Lamp Life Available Filters Panel Controls Panel Displays Warm-up Period Power In Power Supply Dimensions (LxWxH) Weight Includes Warranty BENEFITS Improved shutter activation latency increasing productivity Provides trigger signal versatility by selecting either edge or level modes Less frequent lamp changes for lower operating costs Maintain optimum operating condition, stable lamp output, longer lamp life, accumulated lamp hours Allowing very precise control of output Beneficial for automated assembly processes DESCRIPTION High Pressure 200 Watt Mercury Vapor Short Arc 2000 hours (guaranteed) Standard: 320-500nm Optional: 250-450nm*, 365nm, 320-390nm, 400-500nm, 250-600nm* Power On/Off, LED Display, Up/Down Adjust Buttons, Start/Stop Button Accumulated lamp usage, Exposure time (0.2-999.9sec), iris setting (0-100%) / irradiance level (0.2W/cm² - 40W/cm²), lamp on/warm-up, shutter open, calibrated, Light Guide detection, shutter/lamp error 4-minutes (typical) 100-120VAC / 200-240VAC, 50/60Hz High efficiency, switch mode, line isolated GENERAL SPECIFICATIONS 13.3 x 7.1 x 7.9 (33.8cm x 18.0cm x 20.1cm) 9.9lbs (4.5kg) Lamp Module, Selected Filter (installed), Protective Eyewear, Grounded and Shielded Power Cord, Foot Pedal, Manual 1 year (excluding Lamp and Light Guide)

Expanding Your Options Light Delivery To accommodate the various needs of its customers, the OmniCure S2000 is adaptable to four different light guide options. Ideally used with a multi-legged High Power Fiber Light Guide to cure multiple sites with a single light source, Single-Legged, Liquid-Filled and Fiber Light Guides are also available. Radiometer Optional Accessory: OmniCure R2000 Radiometer. Accurate radiometry is essential to maintaining a calibrated and repeatable UV curing process suitable for consistent, highquality production. Flexible Spectral Output The broad spectral output makes the OmniCure S2000 ideal for a wide range of applications. Selectable bandpass filters allow you to customize the light for your specific application.

Poly Dispensing Systems PDS S.A.S is a french company that commercializes a wide range of dosage equipments, proven and effective. Distributed in over 20 countries around the world, these equipements provide tailored solutions to many users in order to improve technically their manufacturing and reduce their productions costs. Our collaborators and sales engineers all have a strong technical competences. They are able to answer your questions and offer you, after analysis, the right solution for your particular need. FRANCE - SWITZERLAND NORTH AFRICA Poly Dispensing Systems 122, Chemin de la Cavée 78630 Orgeval FRANCE + 33 (0)1 39 62 40 92 + 33 (0)1 39 62 40 94 BELGIUM - NETHERLANDS LUXEMBOURG Gentec Benelux Rue de L Industrie, 12 B-1400 Nivelles BELGIQUE +32 2 351 1800 +32 2 351 1962 www.gentec-benelux.com