Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST REPORT... 1 CONTENT...

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

1 SUMMARY OF STANDARDS AND RESULTS

EMC test report AU01+E04

Test Report GUANGDONG EAST POWER CO., LTD

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

3. MEASURING DEVICES AND TEST EQUIPMENT For Radiated Emission Measurement... 6

PT. SARANA KARYA SOLUSINDO.

EMC TEST REPORT. Report No.: CE10-LIE040101E

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC Test report for LED Panel Light Models , , , , ,

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

2620 Modular Measurement and Control System

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

9. Electrostatic Discharge Immunity Test (ESD)

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. According to

CONFORMANCE TEST REPORT FOR EN /-6

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

TEST REPORT on behalf of Shanghai ZLAN Information Technology Co.,Ltd Serial Device Server

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC TEST REPORT. According to

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Description of Version

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

CE EMC Test Certification

C E R T I F I C A T I O N

EMC MEASUREMENT AND TEST REPORT

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

CE TEST CERTIFICATION

CE TEST CERTIFICATION

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

EMC Test Report. Report Number: M030826

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC TEST REPORT For : SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard

EMC TEST REPORT. according to

CE-EMC TEST REPORT. Prepared for : Kinglumi Co., Ltd. Bldg 3, Nangang 3nd Industrial Zone, Tangtou, Shiyan Town, Bao an District, Shenzhen City, China

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

Transcription:

EMC TEST REPORT For MPP SOLAR INC Model Number: PIP 2424MS Prepare for Address : MPP Solar Inc : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan Prepare by Address : MPP Solar In : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan E.U.T. : Inverter (3KVA) Brand Name : MPP Solar Model NO. : PIP 2424MS Measurement Standard : EN 55022:2010 EN 61000-3-2:2006+A1:2009+A2, EN 61000-3-3:2008 EN 55024:2010 (EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-11:2004) Date of Test : Jul. 3 to Jul. 24, 2013 Date of Report : Aug. 08, 2013 This Test Report is issued under the Authority of: Prepared by Approved by This report shows that the E.U.T. is technically compliant with the EN 55022, EN 61000-3-2, EN 61000-3-3, and EN 55024. This report applies to above tested sample only and shall not be reproduced in part without written approval of MPP Solar Inc 1 / 47

TABLE OF CONTENTS 1. SUMMARY OF TEST RESULTS...4 2. GENERAL INFORMATION...5 2.1 Details of E.U.T....5 2.2 Description of Support Device...5 2.3 Block Diagram of Test Setup...5 2.4 Test Facility...6 2.5 Abnormalities from Standard Conditions...6 3. MEASURING DEVICES AND TEST EQUIPMENT...7 3.1 For Mains terminals Disturbance voltage Test...7 3.2 For Radiated Emission Measurement...7 3.3 For Harmonic / Flicker Measurement...7 3.4 For Electrostatic Discharge Immunity Test...8 3.5 For RF Electromagnetic Field Immunity Test...8 3.6 For Electrical Fast Transient /Burst Immunity Test...8 3.7 For Surge Immunity Test...8 3.8 For Injected Currents Immunity Measurement...8 3.9 For Voltage Dips and Interruptions Measurement...8 4. MAINS TERMINAL DISTURBANCE VOLTAGE MEASUREMENT...9 4.1 Block Diagram of Test Setup...9 4.2 Limit of Mains Terminal Disturbance voltage measurement...9 4.3 Test Procedure...10 4.4 Operating Condition of E.U.T...10 4.5 Mains Terminal Disturbance Voltage Test Results...10 5. RADIATED EMISSION MEASUREMENT...15 5.1 Block Diagram of Test...15 5.2 Limit of Radiated Emission Measurement...15 5.3 Test Procedure...16 5.4 Operating Condition of E.U.T...16 5.5 Radiated Emission Measurement Result...16 6. HARMONIC CURRENT EMISSION TEST...21 6.1 Block Diagram of Test Setup...21 6.2 Limits of Harmonics current measurement...21 6.3 Test Procedure...22 6.4 Operating Condition of E.U.T...22 6.5 Test Results...22 7. VOLTAGE FLUCTUATIONS & FLICKER TEST...26 7.1 Block Diagram of Test Setup...26 7.2 Limits of Voltage Fluctuations & Flicker Measurement...26 7.3 Test Procedure...26 7.4 Operating Condition of E.U.T...26 2 / 47

7.5 Test Results... 27 8. PERFORMANCE CRITERIA FOR IMMUNITY...29 9. ELECTROSTATIC DISCHARGE TEST...30 9.1 Block Diagram of Test Setup...30 9.2 Test Standard and Severity Levels...30 9.3 Test Procedure...31 9.4 Test Results...31 10. RF FIELD STRENGTH SUSCEPTIBILITY TEST...33 10.1 Block Diagram of Test Setup...33 10.2 Test Standard and Severity Levels...33 10.3 Test Procedure...34 10.4 Test Results...34 11. ELECTRICAL FAST TRANSIENT/BURST TEST...36 11.1 Block Diagram of Test Setup...36 11.2 Test Standard and Severity Levels...36 11.3 Test Procedure... 37 11.4 Test Result... 37 12. SURGE IMMUNITY TEST...39 12.1 Block Diagram of Test Setup...39 12.2 Test Standard and Severity Levels...39 12.3 Test Procedure...39 12.4 Test Result...40 13. INJECTED CURRENTS SUSCEPTIBILITY TEST...42 13.1 Block Diagram of Test Setup...42 13.2 Test Standard and Severity Levels...42 13.3 Test Procedure...43 13.4 Test Result...43 14. VOLTAGE DIPS AND INTERRUPTIONS TEST...45 14.1 Block Diagram of Test Setup...45 14.2 Test Standard and Severity Levels...45 14.3 Test Procedure...45 3 / 47

1. SUMMARY OF TEST RESULTS The E.U.T. has been tested according to the following specifications: Standard Test Type Result Remarks Mains Terminal Disturbance PASS Uncertainty: 2.7dB EN 55022: 2010 Voltage Test Radiated Emission Test PASS Uncertainty: 3.4dB EN 61000-3-2: 2006+ A1: 2009+A2: 2009 Harmonic current emission PASS Meets the requirements. EN 61000-3-3: 2008 Voltage fluctuations & flicker PASS Meets the requirements. IMMUNITY(EN 55024: 2010) Standard Test Type Result Remarks Meets the EN 61000-4-2: 2009 Electrostatic discharge PASS requirements of immunity test Performance Criterion B EN 61000-4-3: 2006+A2: 2010 EN 61000-4-4: 2004+A1: 2010 EN 61000-4-5: 2006 EN 61000-4-6: 2009 EN 61000-4-11: 2004 Radio-frequency, electromagnetic field immunity test Electrical fast transient/ burst immunity test Surge immunity test Injected Currents immunity test Voltage Dips and Interruptions PASS PASS PASS PASS PASS Meets the requirements of Performance Criterion A Meets the requirements of Performance Criterion B Meets the requirements of Performance Criterion B Meets the requirements of Performance Criterion A Meets the requirements of Performance Criterion B&C 4 / 47

2. GENERAL INFORMATION 2.1 Details of E.U.T. E.U.T. Model No. Brand Name E.U.T. Type Operation Frequency Rating Test Voltage Cable Description of model different Remark : Inverter (3KVA) : PIP 2424MS : MPP Solar : Class A : Below 108MHz : AC 100-240V 50/60Hz 3KVA/2.4KW : AC 230V 50Hz, DC 24V Battery : None : None : None 2.2 Description of Support Device None 2.3 Block Diagram of Test Setup Block diagram of connection between the E.U.T. and simulators 5 / 47

2.4 Test Facility Site Description EMC Lab: Listed by CNAS, August 16, 2012 The certificate is valid until August 15, 2015 The Laboratory has been assessed and proved to be in compliance with CNAS/CL01 The Certificate Registration Number is L5795. Listed by FCC, August. 02, 2011 The Certificate Number is 665078. Listed by Industry Canada, July 01, 2011 The Certificate Registration Number. Is 46405-9743 2.5 Abnormalities from Standard Conditions None 6 / 47

3. MEASURING DEVICES AND TEST EQUIPMENT 3.1 For Mains terminals Disturbance voltage Test Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCI 101152 Nov. 05, 2011 1 Year 2. L.I.S.N Rohde & Schwarz ENV 216 101317 Nov. 05, 2011 1 Year 3. L.I.S.N Schwarzbeck NNLK8129 8129-212 Nov. 05, 2011 1 Year 4. RF Switching Compliance Direction RSU-M2 38311 Nov. 05, 2011 1 Year Unit Systems Inc. 5. Pulse Limiter MTS-systemtechnik MTS-IMP-136 261115-01 Nov. 05, 2011 1 Year 0-0022 3.2 For Radiated Emission Measurement Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCI7 100837 Nov. 05, 2011 1 Year 2. Antenna Schwarzbeck VULB9162 9162-010 Nov. 28, 2011 1 Year 3. Positioning Controller UC UC 3000 N/A N/A N/A 4. Color Monitor SUNSPO SP-140A N/A N/A N/A 5. Single Phase Power Line SAEMC PF201A-32 110210 N/A N/A 6. 3 Phase Power Line Filter SAEMC PF401A-200 110318 N/A N/A 7. DC Power Filter SAEMC PF301A-200 110245 N/A N/A 8. Cable UBER+SUHNER CBL2-NN-1M 22320001 Nov. 05, 2011 1 Year 9. Cable Schwarzbeck CIL02 N/A Nov. 05, 2011 1 Year 10. Power Amplifier HP HP 8447D 1145A0020 Nov. 05, 2011 1 Year 3 3.3 For Harmonic / Flicker Measurement Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Power California CTS 72846 Nov. 05, 2011 1 Year 2. Software California CTS30 N/A N/A N/A 7 / 47

3.4 For Electrostatic Discharge Immunity Test Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. ESD Tester TESEQ NSG 437 432 Nov. 21, 2011 1 Year 3.5 For RF Electromagnetic Field Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. RF Power Meter ESE 4242 13984 Sep.1, 2012 1 Year 2. Power Amplifier TESEQ CBA 1G-150 T44029 Sep.1, 2012 1 Year 3. Signal Agilent N5181A MY501425 Sep.1, 2012 1 Year 30 Generator 4. Power Sensor ESE 51011EMC 35716 Sep.1, 2012 1 Year 5. Antenna CORAD ATR80M6G 0337307 Sep.1, 2012 1 Year Log-Periodic 3.6 For Electrical Fast Transient /Burst Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Burst Tester EM TEST UCS 500N V1104108683 Nov. 05, 2011 1 Year 2. Coupling Clamp EM TEST HFK 0311-94 Nov. 05, 2011 1 Year 3. Test Soft EM TEST lec. control N/A N/A N/A 3.7 For Surge Immunity Test Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Surge Tester EM TEST UCS 500N V1104108683 Nov. 05, 2011 1 Year 2. Test Soft EM TEST lec. control N/A N/A N/A 3.8 For Injected Currents Immunity Measurement Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. CS Test System FRANNIA CIT-10 126A1163 Mar. 22, 2013 1 Year 2. CDN FRANNIA CDN-M2+M3 A2210150 Mar. 22, 2013 1 Year 3.9 For Voltage Dips and Interruptions Measurement Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Dips Tester EM TEST UCS500N V1104108683 Nov. 05, 2011 1 Year 2. Test Soft EM TEST lec.control N/A N/A N/A 3. Dips EM TEST V4780S2 0111-11 Nov. 05, 2011 1 Year 8 / 47

4. MAINS TERMINAL DISTURBANCE VOLTAGE MEASUREMENT 4.1 Block Diagram of Test Setup 4.2 Limit of Mains Terminal Disturbance voltage measurement Test Standard: EN 55022 Limits for conducted disturbance at the mains ports of class A ITE. Frequency range Limits (dbìv) MHz Quasi-peak Average 0.15 to 0.50 79 66 0.50 to 30 73 60 Note: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.5 MHz. 9 / 47

4.3 Test Procedure The E.U.T. is put on the 0.8 m high table and connected to the AC mains through a Artificial Mains Network (AMN). This provided a 50ohm coupling impedance for the tested equipments. Both sides of AC line are checked to find out the maximum conducted emission levels according to the EN55022 regulations during conducted emission test. The bandwidth of the test receiver (R&S Test Receiver ESCI) is set at 9 KHz. 4.4 Operating Condition of E.U.T. 4.4.1 Setup the E.U.T. and simulators as shown in Section 2.3. 4.4.2 Turn on the power of all equipments. 4.4.3 Let the E.U.T. work in modes (Normal operation mode, Stored energy operation mode) and test it. 4.5 Mains Terminal Disturbance Voltage Test Results PASS. Please refer to the following pages. 10 / 47

11 / 47

12 / 47

13 / 47

14 / 47

5. RADIATED EMISSION MEASUREMENT 5.1 Block Diagram of Test 5.2 Limit of Radiated Emission Measurement Test Standard: EN 55022 Limits for radiated disturbance of class A ITE at a measuring distance of 3m Limits below 1GHz Frequency range MHz 30 to 230 230 to 1000 Quasi-peak limits db(uv/m) 50 Note 1 The lower limit shall apply at the transition frequency. Note 2 Additional provisions may be required for cases where interference occurs. 57 15 / 47

5.3 Test Procedure E.U.T. and its simulators are placed on a turntable, which is 0.8 meter high above ground. The turntable can rotate 360 degrees to determine the position of the maximum emission level. E.U.T. is set 3.0 meters away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and down between 1.0 meter and 4 meters to find out the maximum emission level. Broadband antenna (calibrated bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of the antenna is set on measurement. In order to find the maximum emission levels, all of the interface cables must be manipulated according to EN55022 on radiated emission measurement. The bandwidth of the EMI test receiver (R&S ESCI7) is set at 120 KHz. The frequency range from 30 MHz to 1000 MHz is checked. 5.4 Operating Condition of E.U.T. 5.4.1 Setup the E.U.T. and simulators as shown in Section 2.3. 5.4.2 Turn on the power of all equipments. 5.4.3 Let the E.U.T. work in modes (Normal operation mode, Stored energy operation mode) and test it. 5.5 Radiated Emission Measurement Result PASS. Please refer to the following pages. 16 / 47

17 / 47

18 / 47

19 / 47

20 / 47

6. HARMONIC CURRENT EMISSION TEST 6.1 Block Diagram of Test Setup 6.2 Limits of Harmonics current measurement Test Standard: EN 61000-3-2: 2006+A1: 2009+A2: 2009 Limits for Class A equipment Harmonics Order n Max. permissible harmonics current A Odd harmonics 3 2.30 5 1.14 7 0.77 9 0.40 11 0.33 13 0.21 15<=n<=39 0.15 15/n Even harmonics 2 1.08 4 0.43 6 0.30 8<=n<=40 Harmonics Order n Limits for Class D equipment Max. permissible harmonics current per watt ma/w Max. permissible harmonics current A 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33 13 0.30 0.21 15<=n<=39 3.85/n 0.15 15/n 0.23 8/n For the following categories of equipment limits are not specified in this edition of thestandard. Note 1: Equipment with a rated power of 75W or less, other than lighting equipment. 21 / 47

6.3 Test Procedure The E.U.T. was put on the top of a wooden table 0.8m above the ground and operated to produce the maximum harmonic components under normal operating conditions for each successive harmonic component in turn. The E.U.T. is classified as follows: Class A: Balanced three-phase equipment, Household appliances excluding equipment as Class D, Tools excluding portable tools, Dimmers for incandescent lamps, audio equipment,equipment not specified in one of the three other classes. Class B: Portable tools; Arc welding equipment which is not professional equipment. Class C: Lighting equipment. Class D: Equipment having a specified power less than or equal to 600W of the following types: Personal computers and personal computer monitors and television receivers. 6.4 Operating Condition of E.U.T. 6.4.1 Setup the E.U.T. and simulators as shown in Section 2.3. 6.4.2 Turn on the power of all equipments. 6.4.3 Let the E.U.T. work in test mode (Normal operation mode) and test it. 6.5 Test Results PASS. Please refer to the following page. 22 / 47

Harmonics Class-A per Ed. 3.2 (2009)(Run time) EUT: Inverter(3KVA) Tested by: Sance Test category: Class-A per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2013-07-08 Start time: 15:49:27 End time: 15:52:19 Test duration (min): 2.5 Data file name: H-000113.cts_data Comment: Normal Customer: MPP SOLAR INC M/N: PIP 2424MS Test Result: Source qualification: Normal Current & voltage waveforms Harmonics and Class A limit line European Limits The test result:. Worst harmonic was #9 with 25.86% of the limit. 23 / 47

Current Test Result Summary (Run time) EUT: Inverter (3KVA) Tested by: Sance Test category: Class-A per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2013-07-09 Start time: 13:31:15 End time: 13:34:07 Test duration (min): 2.5 Data file name: H-000113.cts_data Comment: Normal Customer: MPP SOLAR INC M/N:PIP 2424MS Test Result: Source qualification: Normal THC (A): 0.44 I-THD (%): 4.49 POHC (A):00 POHC Limit (A):0.320 Highest parameter values during test: V_RMS (Volts): 229.95 Frequency (Hz): 50 I_Peak (Amps): 13.665 I_RMS (Amps): 9.771 I_Fund (Amps): 9.746 Crest Factor: 1.400 Power (Watts): 2235.8 Power Factor: 0.997 Harm# Harms(avg) 100%Limit %of Harms(max) 150%Li %of Status 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 05 0.319 03 0.223 03 0.152 02 0.103 02 73 01 52 01 37 01 29 01 24 02 21 01 19 01 18 00 16 01 14 01 13 01 12 01 13 01 14 01 16 02 1.080 2.300 0.430 1.140 0.300 0.770 0.400 0.184 0.330 0.153 0.210 0.131 0.150 0.115 0.132 0.102 0.118 92 0.107 84 98 77 90 71 83 66 78 61 73 58 68 54 64 51 61 48 58 46 Limit 13.9 19.6 19.8 25.9 22.1 07 0.327 05 0.227 03 0.156 02 0.106 02 74 01 52 01 38 02 29 02 25 02 22 01 20 01 18 01 16 01 14 01 15 02 13 01 15 01 16 01 17 02 mit 1.620 3.450 0.645 1.710 0.450 1.155 0.345 0.600 0.276 0.495 0.315 0.197 0.225 0.173 0.199 0.153 0.178 0.138 0.161 0.125 0.147 0.115 0.135 0.106 0.125 99 0.116 92 0.109 86 0.102 81 96 77 91 73 87 69 Limit 0.44 9.48 0.81 13.25 0.73 13.51 0.67 17.74 0.84 14.96 0.63 16.55 0.65 16.72 1.06 14.50 1.08 13.91 1.65 13.71 0.88 13.42 0.65 13.16 0.64 12.92 0.92 12.43 1.56 13.88 1.84 12.90 1.25 15.81 1.44 17.80 1.81 19.18 3.15 24 / 47

Voltage Source Verification Data (Run time) EUT: Inverter (3KVA) Tested by: Sance Test category: Class-A per Ed. 3.2 (2009) (European limits) Test Margin: 100 Test date: 2013-07-10 Start time: 14:41:23 End time: 14:44:15 Test duration (min): 2.5 Data file name: H-000113.cts_data Comment: Normal Customer: MPP SOLAR INC M/N: PIP 2424MS Test Result: Source qualification: Normal Highest parameter values during test: Voltage (Vrms): 229.95 Frequency(Hz): 50 I_Peak (Amps): 13.665 I_RMS (Amps): 9.771 I_Fund (Amps): 9.746 Crest Factor: 1.400 Power (Watts): 2235.8 Power Factor: 0.997 Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 83 0.574 77 55 55 51 31 21 27 33 19 30 13 19 18 22 16 32 28 24 08 17 05 14 06 13 04 16 05 17 06 14 04 21 04 23 05 25 15 0.460 2.069 0.460 0.920 0.460 0.690 0.460 0.460 0.460 18.03 27.75 16.73 5.93 12.02 7.40 6.72 4.66 5.80 14.33 8.34 13.10 5.49 8.37 7.91 9.56 7.09 14.04 12.13 10.45 3.52 7.39 2.13 6.19 2.58 5.83 1.74 6.90 2.32 7.47 2.73 6.21 1.73 9.28 1.79 9.85 2.28 10.69 6.40 25 / 47

7. VOLTAGE FLUCTUATIONS & FLICKER TEST 7.1 Block Diagram of Test Setup 7.2 Limits of Voltage Fluctuations & Flicker Measurement Test Standard: EN 61000-3-3: 2008 Test Item Pst (Short-term flicker indicator.) Plt (Long-term flicker indicator.) Td(t)(ms) ( Maximum time that d(t) exceeds 3.3%) dmax(%) (Maximum relative voltage change.) dc(%) (Relative steady-state voltage change) Limit 1.0 0.65 500 4 3.3 7.3 Test Procedure The E.U.T. was put on the top of a wooden table 0.8m above the ground and operated to produce the most unfavorable sequence of voltage changes under normal operating conditions. 7.4 Operating Condition of E.U.T. 7.4.1 Setup the E.U.T. and simulators as shown in Section 2.3. 7.4.2 Turn on the power of all equipments. 7.4.3 Let the E.U.T. work in test mode (Normal operation mode) and test it. 26 / 47

7.5 Test Results PASS. Please refer to the following page. 27 / 47

Flicker Test Summary per EN/IEC61000-3-3(Run time) EUT: Inverter (3KVA) Tested by: Sance Test category: All parameters (European limits) Test Margin: 100 Test date: 2013-07-11 Start time: 13:34:48 End time: 13:45:09 Test duration (min): 10 Data file name: F-000114.cts_data Comment: Normal Customer: MPP SOLAR INC M/N: PIP 2424MS Test Result: Status: Test Completed Psti and limit line European Limits Plt and limit line Parameter values recorded during the test: Vrms at the end of test (Volt): 225.82 Highest dt (%): 0 Test limit (%):3.30 Time(mS) > dt: Test limit (ms): 50 Highest dc (%): 0 Test limit (%):3.30 Highest dmax (%): 0 Test limit (%):4.00 Highest Pst (10 min. period): 64 Test limit: 1.000 Highest Plt (2 hr. period): 28 Test limit: 0.650 28 / 47

8. PERFORMANCE CRITERIA FOR IMMUNITY The performance criteria are referred to the test standard: EN 55024 Performance Criteria A The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended. Performance Criteria B After the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance of loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operation state or stored data is allowed to persist after test. If the minimum performance lever (or the permissible performance loss) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonable expect from the equipment if used as intended. Performance Criteria C Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacturer s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost. 29 / 47

9. ELECTROSTATIC DISCHARGE TEST 9.1 Block Diagram of Test Setup 9.2 Test Standard and Severity Levels 9.2.1 Test Standard: EN 55024 (EN 61000-4-2: 2009 Air Discharge: Severity Level: 3, ± 8KV; Contact Discharge: Level: 2, ± 4KV) 9.2.2 Severity Levels: Level Test Voltage Contact Discharge (KV) 1. ±2 2. ±4 3. ±6 4. ±8 X Special Test Voltage Air Discharge (KV) ±2 ±4 ±8 ±15 Special 30 / 47

9.3 Test Procedure 9.3.1 Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the E.U.T.. After each discharge, the discharge electrode shall be removed from the E.U.T.. The generator is then re-triggered for a new single discharge and repeated 20 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed 9.3.2 Contact Discharge: All the procedure shall be same as Section 9.3.1. except that the tip of the discharge electrode shall touch the E.U.T. and the generator is then re-triggered for a new single discharge and repeated 50 times for each pre-selected test point. 9.3.3 Indirect discharge for horizontal coupling plane At least 10 single discharges(in the most sensitive polarity) shall be applied at the front edge of each HCP opposite the center point of each unit(if applicable) of the E.U.T. and 0.1m from the front of the E.U.T.. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge. 9.3.4 Indirect discharge for vertical coupling plane At least 10 single discharge (in the most sensitive polarity) shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the E.U.T.. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the E.U.T. are completely illuminated. 9.4 Test Results PASS. Please refer to the following page. 31 / 47

Electrostatic Discharge Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: Test Specifications: Tested mode: AC 230V 50Hz, Required Performance Criterion: B DC 24V ±2, 4 kv Contact Discharge; ±2, 4, 6, 8 kv Air Discharge Contact: For each point positive 25 times and negative 25 times Air: For each point positive 10 times and negative 10 times Normal operation mode, Stored energy operation mode Test Point Kind A-Air Discharge C-Contact Discharge Result (Performance Criterion) Slot of the E.U.T. 10 points C A DC Output 8 points A A Enclosure 10 points A. C A Indirect Discharge (HCP) C A Indirect Discharge (VCP) C A Note: Test Equipment : ESD Tester (TESEQ, NSG 437) Test Engineer : Sance 32 / 47

10. RF FIELD STRENGTH SUSCEPTIBILITY TEST 10.1 Block Diagram of Test Setup 10.2 Test Standard and Severity Levels 10.2.1 Test Standard EN 55024 (EN 61000-4-3: 2006+A2: 2010, Severity Level: 2, 3V/m) 10.2.2 Severity Levels Level 1. 2. 3. X Field Strength V/m 1 3 10 Special 33 / 47

10.3 Test Procedure The E.U.T. and its simulators are placed on a turn table which is 0.8 meter above ground. E.U.T. is set 3 meter away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of E.U.T. must be faced this transmitting antenna and measured individually. All the scanning conditions are as follows : Condition of Test Remarks ----------------------------------------- ---------------------------------------- 1. Fielded Strength 3 V/m (Severity Level 2) 2. Radiated Signal Modulated 3. Scanning Frequency 80-1000 MHz 4. Dwell time of radiated 015 decade/s 5. Waiting Time 1 Sec. 10.4 Test Results PASS. Please refer to the following page. 34 / 47

RF Field Strength Susceptibility Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: AC 230V 50Hz, Required Performance Criterion: A DC 24V Test Specifications: Modulation: 1kHz, 80%AM; Step Size: 1%; Dwell Time: 1s Tested mode: Frequency (MHz) Normal operation mode, Stored energy operation mode Level (V/m) 80-1000 3 Antenna polarity Horizontal Vertical Side Front Left Right Back Front Left Right Back Result (Performance Criterion) A A A A A A A A Note: Test Equipment : 1. Signal Generator : N5181A (Agilent) 2. Power Amplifier : CBA 1G-150 (TESEQ) 3. Log.-Per. Antenna: ATR80M6G (CORAD) 4. RF Power Meter. Dual Channel : 4242 (ESE) 5. Power Sensor: 51011EMC (ESE) Test Engineer : Sance 35 / 47

11. ELECTRICAL FAST TRANSIENT/BURST TEST 11.1 Block Diagram of Test Setup 11.2 Test Standard and Severity Levels 11.2.1 Test Standard EN 55024 (EN 61000-4-4: 2004+A1: 2010, Severity Level, Level 2: 1KV) 11.2.2 Severity level Open circuit output test voltage and repetition rate of the impulses Level 1. 2. 3. 4. X On power port, PE Voltage peak KV 0.5 1.0 2.0 4.0 Special Repetition rate KHz 5 or 100 5 or 100 5 or 100 5 or 100 Special On I/O (Input/Output) Signal data and control ports Voltage peak Repetition rate KV KHz 0.25 5 or 100 0.5 5 or 100 1.0 5 or 100 2.0 5 or 100 Special Special Note 1 Use of 5 KHz repetition rates is traditional; however, 100 KHz is closer to reality. Product committees should determine which frequencies are relevant for specific products or product types. Note 2 With some products, there may be no clear distinction, between power ports and I/O ports, in which case it is up to product committees to make this determination for test purposes. Note 3 X is an open level. The level has to be specified in the dedicated equipment specification. 36 / 47

11.3 Test Procedure The E.U.T. is put on the table which is 0.8 meter high above the ground. This reference ground plane shall project beyond the E.U.T. by at least 0.1m on all side and the minimum distance between E.U.T. and all other conductive structure, except the ground plane beneath the E.U.T., shall be more than 0.5m. 11.3.1 For input and output AC power ports: The E.U.T. is connected to the power mains by using a coupling device which couples the EFT interference signal to AC power lines. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 minutes. 11.3.2 For signal lines ports: It s unnecessary to test. 11.3.3 For DC ports: It s unnecessary to test. 11.4 Test Result PASS. Please refer to the following page. 37 / 47

Electrical Fast Transient/Burst Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: AC 230V 50Hz Required Performance Criterion: B Test Specifications: Test mode: Repetition Frequency: 5kHz; Duration: 15ms; Period: 300ms Normal operation mode Line : AC Mains Signal line DC line Coupling : Direct Capacitive Note : Line Test Voltage Result (Performance Criterion) L ±1KV A N ±1KV A PE ±1KV A L N ±1KV A L PE ±1KV A N PE ±1KV A L N PE ±1KV A Signal line DC line Test Equipment : Burst Tester(EM TEST, UCS500N) Test Engineer : Sance 38 / 47

12. SURGE IMMUNITY TEST 12.1 Block Diagram of Test Setup 12.2 Test Standard and Severity Levels 12.2.1 Test Standard EN 55024 (EN 61000-4-5: 2006, Severity Level: Line To Line, Level 2:1.0KV; Line to Earth, Level 3: 2.0KV) 12.2.2 Severity level Severity Level 12.3 Test Procedure 1 2 3 4 * Open-Circuit Test Voltage KV 0.5 1.0 2.0 4.0 Special 1. Set up the E.U.T. and test generator as shown on Section 12.1. 2. For line to line coupling mode, provide a 1.0KV 1.2/50us voltage surge (at open-circuit condition) and 8/20us current surge to E.U.T. selected points. 3. At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are conducted during test. 4. Different phase angles are done individually. 39 / 47

5. Record the E.U.T. operating situation during compliance test and decide the E.U.T. immunity criterion for above each test. 12.4 Test Result PASS. Please refer to the following page. 40 / 47

Surge Immunity Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: AC 230V 50Hz Required Performance Criterion: B Test Specifications: Voltage surge 1.2/50 us ; Current surge 8/20 us ; Five positive and five negative pulses each at 0, 90, 180 and 270. Test mode: Normal operation mode Line Phase Angle Test Voltage Result (Performance Criterion) L-N 0, 90, 180, 270 ±1KV A L-PE 0, 90, 180, 270 ±2KV A N-PE 0, 90, 180, 270 ±2KV A Signal line DC line Note : Test Equipment : Burst Tester(EM TEST, UCS500N) Test Engineer : Sance 41 / 47

13. INJECTED CURRENTS SUSCEPTIBILITY TEST 13.1 Block Diagram of Test Setup 13.2 Test Standard and Severity Levels 13.2.1 Test Standard EN 55024 (EN 61000-4-6: 2009, Severity Level: 3V (rms), 0.15MHz ~ 80MHz) 13.2.2 Severity level Level 1. 2. 3. X Field Strength V 1 3 10 Special 42 / 47

13.3 Test Procedure 1. Set up the E.U.T., CDN and test generators as shown on Section 13.1. 2. Let the E.U.T. work in test mode and measure it. 3. The E.U.T. are placed on an insulating support 0.1m high above a ground reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3m from E.U.T.. Cables between CDN and E.U.T. are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 4. The disturbance signal described below is injected to E.U.T. through CDN. 5. The E.U.T. operates within its operational mode(s) under intended climatic conditions after power on. 6. The frequency range is swept from 150 KHz to 80 MHz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1KHz sine wave. 7. The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value. 8. Recording the E.U.T. operating situation during compliance testing and decide the E.U.T. immunity criterion. 13.4 Test Result PASS. Please refer to the following page. 43 / 47

Injected Currents Susceptibility Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: AC 230V 50Hz Required Performance Criterion: A Test Specifications: Test mode: Modulation : 1KHz, 80%AM, Step Size : 1%, Dwell Time : 1s Normal operation mode Test Port Frequency (MHz) Level(V) Result (Performance Criterion) AC Mains 0.15~80 3 A Note : Test Equipment : FRANNIA, CIT-10 Test Engineer : Sance 44 / 47

14. VOLTAGE DIPS AND INTERRUPTIONS TEST 14.1 Block Diagram of Test Setup 14.2 Test Standard and Severity Levels 14.2.1 Test Standard EN 55024 (EN 61000-4-11: 2004) 14.2.2 Severity level Test Level %UT Voltage dip and short interruptions %UT 0 100 40 60 70 30 Duration (in period) 0.5 1 5 10 25 50 * 14.3 Test Procedure 1. Set up the E.U.T. and test generator as shown on Section 14.1. 2. The interruptions are introduced at selected phase angles with specified duration. 3. Record any degradation of performance. 45 / 47

14.4 Test Result PASS. Please refer to the following page. 46 / 47

Voltage Dips and Interruptions Test Results Ambient Condition: Temp.: 27 R.H.: 56 % Air Pressure: 98 kpa Power Supply: AC 230V 50Hz Required Performance Criterion: B & C Test Specifications: 0%UT, 0.5Cycle; 70%UT, 25Cycle; 0%UT,250Cycle Test mode: Test Level % UT Normal operation mode Duration (in period) Result (Performance Criterion) 0 0.5P A 70 25P B 0 250P B Note : Test Equipment : Dips Tester: EM TEST, UCS 500N Test Engineer : Sance 47 / 47