Development of a spectrometry system Using lock-in amplification technique

Similar documents
Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

TracQ. Basic Data Acquisition and Spectroscopy Software

A DSP IMPLEMENTED DIGITAL FM MULTIPLEXING SYSTEM

Supplementary Materials for

Design Implementation Description for the Digital Frequency Oscillator

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

combustion diagnostics

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Multi-Channel High Performance Data Acquisition System and Digital Servo Controller Module

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Improving the Collection Efficiency of Raman Scattering

Experimental Analysis of Luminescence in Printed Materials

The University of Toledo R. Ellingson and M. Heben

Measuring of small AC signals using lock-in amplifiers. Narrow band selective amplifiers + amplitude detector. Lock-in amplifiers

Lock-In Amplifiers SR510 and SR530 Analog lock-in amplifiers

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

pulsecheck The Modular Autocorrelator

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

ModBox-SB-NIR Near Infra Red Spectral Broadening Unit

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Dual-channel Lock-in Amplifier Module

A Software Implementation of Data Acquisition Control and Management for Czerny Turner Monochromator

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

Measuring of small AC signals using lock-in amplifiers. Narrow band selective amplifiers + amplitude detector. Lock-in amplifiers

Photon Counters SR430 5 ns multichannel scaler/averager

FFT Spectrum Analyzer

SCCH 4: 211: 2015 SCCH

Measuring of small AC signals using lock-in amplifiers. Narrow band selective amplifiers + amplitude detector. Lock-in amplifiers

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

APE Autocorrelator Product Family

University of Wisconsin Chemistry 524 Spectroscopic Components *

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

David Jameson 4/4/2018

Oriel Cornerstone 130 1/8 m Monochromator

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments

COMPONENTS OF OPTICAL INSTRUMENTS. Topics

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

USE OF MATLAB IN SIGNAL PROCESSING LABORATORY EXPERIMENTS

CHAPTER 3 BASIC OPERATING METHODS OF PHOTOMULTIPLIER TUBES

UNMATCHED OUTPUT POWER AND TUNING RANGE

190 nm (6.5 ev) Laser-ARPES. Laser ARPES using a Tunable ps UV Source

Introduction. sig. ref. sig

Universal and compact laser stabilization electronics

A new picosecond Laser pulse generation method.

Low Phase Noise Laser Synthesizer with Simple Configuration Adopting Phase Modulator and Fiber Bragg Gratings

Fast Raman Spectral Imaging Using Chirped Femtosecond Lasers

Applications Information

Chapter 8. Wavelength-Division Multiplexing (WDM) Part II: Amplifiers

Diode Laser Control Electronics. Diode Laser Locking and Linewidth Narrowing. Rudolf Neuhaus, Ph.D. TOPTICA Photonics AG

LASER DOPPLER VELOCIMETRY

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Instructions for the Experiment

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

CONTROLLABLE WAVELENGTH CHANNELS FOR MULTIWAVELENGTH BRILLOUIN BISMUTH/ERBIUM BAS-ED FIBER LASER

Basic Components of Spectroscopic. Instrumentation

MS260i 1/4 M IMAGING SPECTROGRAPHS

FlexDDS-NG DUAL. Dual-Channel 400 MHz Agile Waveform Generator

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

ModBox - Spectral Broadening Unit

Setup of the four-wavelength Doppler lidar system with feedback controlled pulse shaping

CHAPTER 8 PHOTOMULTIPLIER TUBE MODULES

Low threshold continuous wave Raman silicon laser

Models 296 and 295 combine sophisticated

50 MHz Voltage-to-Frequency Converter

Measuring Spectral Performance of Night Vision Devices

Nd: YAG Laser Energy Levels 4 level laser Optical transitions from Ground to many upper levels Strong absorber in the yellow range None radiative to

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

taccor Optional features Overview Turn-key GHz femtosecond laser

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Datasheet C400. Four Channel Pulse Counting Detector Controller

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

IBIL setup operation manual for SynerJY software version

Instruction manual and data sheet ipca h

Basic Instrumentation

Ozone Absorption Cross Sections Laboratory Measurements

DEVELOPMENT OF A NEW INJECTION LOCKING RING LASER AMPLIFIER USING A COUNTER INJECTION: MULTIWAVELENGTH AMPLIFICATION

ericssonz LBI-38640E MAINTENANCE MANUAL FOR VHF TRANSMITTER SYNTHESIZER MODULE 19D902780G1 DESCRIPTION

Ultrafast Surface-Enhanced Raman Probing of the Role of Hot Electrons in Plasmon-Driven Chemistry. Supporting Information

Microscopic Structures

Principles of Fluorescence Techniques 2014 Urbana-Champaign, Illinois April 7-10, 2014

David Jameson 3/23/2015

UV AQUAtracka. In-situ PMT Fluorimeter

1170 LIDAR / Atmospheric Sounding Introduction

Fiber lasers and their advanced optical technologies of Fujikura

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

The Weber Conference on Advanced Fluorescence Microscopy Techniques December 12-17, 2011 Buenos Aires

ULS24 Frequently Asked Questions

THE BENEFITS OF DSP LOCK-IN AMPLIFIERS

Femtosecond to millisecond transient absorption spectroscopy: two lasers one experiment

Working in Visible NHMFL

Transcription:

VNU. JOURNAL OF SCIENCE, Mathematics - Physics, T.xXI, n 0 2, 2005 Development of a spectrometry system Using lock-in amplification technique Department of Physics, College of Science, VNU Abstract. Raman spectroscopy and optical second-harmonic (SH) spectroscopy has a very important role in studies of optical properties of materials. Our goal is to build a spectrometry system to measure weak optical signals such as Raman scattering and surface SH signals. We studied to improve an old Double Grating Spectrograph GDM-1000 (Carl Zeiss, Jena, Germany) for wider range of wavelengths and transformed it successfully into a spectrometry system coupling with computer using Lock-in amplification technique. By this spectrometry system we can now obtain weak optical signals, for example, Raman Spectra of Vietnam petrol extracts excited by not only an 2W Argon laser but also by a 30mW He-Ne laser. Key words: Raman spectroscopy, Optical- Second Harmonic Spectroscopy, Surface SH generation. 1. Introduction Laser Raman spectroscopy including Raman Scattering, Resonance Raman Scattering, Stimulated Raman Scattering (SRS), Coherent Anti- Stokes Raman Scattering (CARS) has been used as a very powerful spectroscopic technique to study molecular structures and optical properties of condensed-phase matters. Recently, Nonlinear Optical Sum Frequency Generation (SFG) and Second Harmonic Generation (SHG) effects have become a spectroscopic tool for surface probe with high surface specificity [1]. The Second Harmonic Spectroscopy is considered as a prominent candidate for better understanding of the optical properties of nanostructures [2]. However, these optical signals are very weak and it requires a spectrometry system with high resolution and sensitivity. The Double Grating Spectrograph GDM-1000 (Carl Zeiss Jena Germany) of our laboratory has a high resolution but it operates with an old self-recorder and a head-on type photomultiplier M12FC which is sensitive to the ultraviolet region (400-550nm). It is suitable only for studying Raman Scattering excited by 5W Ion-Argon laser or high-pressure Hg lamps. Furthermore, the recorded spectra could not be treated by computer. We studied to improve this spectrograph for higher sensitivity in wider range of wavelengths and coupling with computer to treat data. We replaced the M12FC PMT by a side-on R-928 PMT (Hamamatsu) and detected PMT signals by a digital signal processor (DSP) lock-in amplifier (Model SR830, Stanford). A stepper motor with suitable design and construction was connected. A compatible control and data- acquisition program was written for the new spectrometry system. Several measurements were carried out to determine the operation regime and calibration. We succeeded in obtaining Raman spectra of petrol extracts by 30mW He-Ne laser 1

2 excitation. Our new spectrometry system shows many advantages for studying Raman and Fluorescence spectra as well as weak optical signal spectra in general. 2. Construction of the improved Spectrometry system 6 Signal In Spectral Signal LPT Port CPU GPIB interface 7 4 5 SR830 lock-in amplifier Chopper Signal GDM -1000 Step Motor Fig.1: Experimental setup of the spectrometry system 1 3 Fig. 2: Schematic of GDM-1000 1-input slit; 2,5 -mirrors; 4-chopper; 3,6- Gratings; 7- output slit 2 Our experimental setup of the improved spectrometry is shown in Fig.1. The monochromator GDM-1000 consisting of two 650lines/mm gratings can operate in spectrum region of 7500-16675 cm-1 (for the first order of the grating) and in the region of 16675-28700 cm-1 (for the second order of grating). The optical schematic of the GDM-1000 is given in Fig.2. We removed the self-recorder and studied to couple the spectrograph with computer. A stepper motor of 1.8o /step was installed in a suitable position to rotate the grating for wavelength scanning. One step of the motor corresponds to 0.0832cm-1. In the circuit controlling stepper motor through parallel port of computer, a sequence of digital signals is sent to LPT port: 0001;0011;0010;0110;0100;1100;1 000;1001 corresponding to Fig.3: Diagram of stepper motor controller positions steps 1 2 3 4 5 6 7 8 (Fig.3) [3]. The head-on type photo multiplier M12FC of the GDM-1000 spectrograph is sensitive in region of 400-550nm wavelengths (Fig.4a). For the longer wavelength

Development of a spectrometry system using lock-in 3 response up to 900nm, we replaced the M12FC PMT by a side-on R-928 PMT (Hamamatsu). The spectral response characteristics of R-928 PMT is given in Fig.4b. This side-on R-928 PMT employs a reflection-mode photo cathode and a circular-cage structure electron multiplier which has good sensitivity and high amplification at a relatively low supply voltage. A DP-type socket (C6270- Hamamatsu) with built-in voltage divider and power supply was used to operate the R-928 PMT. The C6270 socket has input voltage of 15V±1Vdc and give output voltage of 0-1250 Vdc. Relative sensitivity (a) (b) Wavelength (nm) Fig.4 : Spectral sensitivity of the M12FC (a) and the R-928 PMT (b) Spectral signals from PMT were detected by a DSP lock-in amplifier (Model SR830, Stanford). The block diagram of the SR830 lock-in amplifier was presented in Fig 5. The SR830 has five boards: Key board, display board, Analog Input board, DSP Logic board and CPU and Power supply board. The DSP logic board takes a digital input from the A/D converter on the Analog Input board and perform all of the computations related to the measurements before it is displayed on the screen. This includes generating the digital reference sine wave, demodulating the signal, low-pass filtering the results, and offset and expanding the outputs. The internal oscillator sine output and AUX D/A outputs are generated on this board. The reference phases lock loop control the clock of this board whenever the reference mode is external. These functions are implemented within a system comprised of five function blocks: the digital signal processor (DSP), the DAC outputs, the timing signal generator, the reference clock generator and the I/O interface. Through the use of highly efficient algorithms, the system is capable of real-time lock-in operation to 100kHz with 24dB/oct filtering on both X and Y as well as providing a synthesized analog sine output. The SR830 utilizes a Motorola 24-bit DSP56001 digital signal processor (U501). The DSP is configured without external memory. The lock-in algorithms run entirely within the internal program and data memory of the DSP itself. The host processor bus is connected to the main CPU board via the I/O interface on the DSP logic board. The 80C186 processor on the CPU board acts as the host processor to the DSP.DSP firmware and commands are downloaded from the CPU board to invoke different operating modes. The analog input board provides the very important link between the input spectral signal and the SDP processor. From the front panel BNC the spectral signal passes through a low distortion front-end amplifier, gain stages, notch filters, anti-aliasing filter and

4 finally an A/D converter. Once converted to digital form, the input signal is ready to be processed by the Digital Signal Processor. The SR830 DSP Lock-in Amplifier can be remotely programmed via either the RS232 or GPIB (IEEE-488) interfaces. Any computer supporting one of these interfaces may be used to program the SR830. Both interfaces are receiving at all times, however, the SR830 will send responses to only one interface. We could specify the output interface with the [Setup] key or use the OUTX command at the beginning of every program to direct the responses to the correct interface. Voltage A B Current I Low Noise Differential Amp 50/60 HZ Notch 100/120 HZ Notch 90 0 Shifter Gain Sensitive Detector Low Pass DC Gain Offset Expand R and Calc Y Out R Reference In Discriminator PLL Locked Loop Internal Oscillator Shifter Sensitive Detector Low Pass DC Gain Offset Expand X Out Sine Out TTL Out Discriminator Fig 5: The block diagram of the SR830 lock-in amplifier In this research, a GPIB card is used to communicate between computer and SR830. Before attempting to communicate with the SR830 over the GPIB interface, the SR830's device address must be set. The address is set with the [Setup] key and may be set between 1 and 30. Communications with the SR830 uses ASCII characters. Commands may be in either upper or lower case and may contain any number of embedded space characters. A command to the SR830 consists of a four characters command mnemonic, arguments if necessary, and a command terminator. The SR830 has a 256 character input buffer and processes commands in the order received. Similarly, the SR830 has a 256-character output buffer to store outputs until the host computer is ready to receive. Detailed command list can be seen in reference [4]. A computer program (named Spectra-Department of Quantum Optics-VNU) was written coding in Visual Basic to control the spectrum measurement procedure and data- acquisition. The interface of this program is presented bellow.

Development of a spectrometry system using lock-in 5 Fig.6: The interface of the spectrum measurement procedure 3. Spectrum measurements Fig 7: Raman spectra of petrol extract samples a-sample 5B110 excited by Argon laser; b- Sample 5B110 excited by He-Ne laser c-sample 5B115 excited by Argon laser; d- Sample 5B115 excited by He-Ne laser We carried out several spectrum measurements to determine the operation regime and calibration of the improved spectrometry system, for examples, fluorescence spectra of Mn-doped ZnS, Stokes and Anti-Stokes Raman scattering spectra of some typical Hydrocarbons excited by Argon laser and He-Ne laser. Our

6 new spectrometry system shows high sensitivity and resolution and many advantages for studying Raman and Fluorescence spectra. We succeeded in obtaining Raman spectra of petrol extracts by 30mW He-Ne laser excitation. The high sensitivity of this spectrometry system in the Red and IR -spectrum region gives the capacity to study the Raman spectra of weak intensity excited by a medium power He-Ne laser instead of CW-high power water - cooled Ion-Argon laser. Furthermore, there was not Fluorescence spectrum profile in Raman spectra excited by He-Ne laser of 632,8nm wavelength. In many cases of Raman spectrum studies, the excitation by near UV- Argon laser results in fluorescence which overlaps Raman spectrum. This was proved very clearly in the Raman spectra of the petrol extract sample 5B110 and 5B11 (petrol extracts from Bach Ho, Vietnam). The Raman spectra excited by He-Ne laser showed more Raman peaks, that means more information, in comparison with Argon laser excitation (Fig.7) 4. Conclusion We improved an old Double Grating Spectrograph GDM-1000 (Carl Zeiss, Jena, Germany) for high sensitivity in wider range of wavelengths and transformed it successfully into a high resolution spectrometry system coupling with computer using Lock-in amplification technique. This is an economic solution and very suitable for teaching and research in Universities. By this spectrometry system we can now obtain weak optical signals, for example, Raman Spectra of Vietnam petrol extracts excited by a 30mW He-Ne laser instead of Ion Argon laser. The Raman excitation by He-Ne laser showed many advantages in comparison with Argon laser excitation. Acknowledgements: This work is supported by the Natural Science Research Program of VNU (QG-04) and the National Basic Science Research Program of Vietnam. References 1. Nguyen The Binh, Surface probe by second harmonic generation, Advances in Photonics and Applications, (2004), pp.75-81. Proceeding of the International Workshop on Photonics and Applications, Hanoi (IWPA- 2004). 2. Takeshi Kitahara, Goro Mizutani, Optical second-harmonic spectroscopy of Au nanowires, Journal of Applied physics, Vol. 95. No9(2004). 3. Bhaskar Gupta, Understanding various types of Stepper Motors And Controlling it through Parallel Port, Homepage: http://collection.sharewith.us (2004). 4. Stanford Research Systems, Model SR830 DSP Lock-in Amplifier, (1993), 5.1-5.34 5. Halina Baranska, Laser Raman spectrometry, John Wiley& sons Warsaw 1987.