World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

Similar documents
Masonry Frames Interior/Exterior* Drywall Frames Interior**

Solid Core Wood Door / Steel Frame Packages

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

55 Series Exit Device

Installation Instructions

S O L I D B R O N Z E H A R D W A R E the beauty of fine design, the eternity of solid bronze V E N E T O SOLID BRONZE

Bravura. UL Listed Commercial Locksets FORGED. Designs from Great European Homes. Fall 2009

1800 Series. Flatbar Exit Devices. An ASSA ABLOY Group brand

88 Series. Exit device

88 Series. Exit device

Hookbolt. Non Handed. Flat LH Bevel RH Bevel Radius Radius with Weather-strip. Radius Flat Bevel

Product Guide. An Introduction to Hollow Metal Terminology and CURRIES Product. ASSA ABLOY, the global leader in door opening solutions

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents

Steel Hawk 4300 Electrified Deadlatch (elatch)

DOOR SAVERS AVAILABLE IN STEEL, STAINLESS STEEL (32D), BRIGHT BRASS (3), BRONZE (10) AND OIL RUBBED BRONZE (10B)

55 Series. Exit device

Mortise Locks. Narrow Mortise Locks Series NML Features Ordering String Functions Trim Sets Cylinders Strikes Specifications

Adams rite. Deadbolts, Deadlocks & Hookbolts Series maximum security laminated deadlocks/hookbolts

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

Headline. Push/Pull Latches

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

TECHNICAL DATA SHEET STANDARD STEEL FRAMES SPECIFICATIONS MESKER STANDARD STEEL FRAMES

1530(F) Mortise Exit Devices Installation Instructions

4200 Series. Commercial Exit Device

Hardware Fitting Accessories Bolts

2100 series exit devices. rugged reliability

Headline Push/Pull Latches

Exit Device 5820 SERIES GRADE 1 PUSH BAR SPECIFICATIONS HEAD COVER OPTIONS STRIKES APPLICATION.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

Introduction Exit Hardware Rim device... 4 Surface mounted vertical rod device... 6 Mortise lock device... 5

Affinity Site Survey. Address: City: State: Zip: Distributor: ACP #: Address: City: State: Zip: Date Submitted: Requested Installation Date:

M O R T I S E L O C K S

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

NM SERIES. Extra Heavy Duty Mortise Locks Grade 1

Monarch XX Series. Crossbar Exit Device

SLIDING DOOR LOCKS MISCELLANEOUS

7.01. Door Hardware & Accessories

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

3000 Series Exit Devices Premier Product

DB1000 SERIES. Heavy-Duty Tubular Grade 1 Deadbolts. Standard Features. Optional Features. Options

Deadlatch 451 Series. Faceplates - Deadlatch. Strikes - Deadlatch. DeadLatch for Aluminum Stile Doors. Non-Handed. 451 NC0772 1¹ 8 Backset Deadlatch 4

STANDARD-DUTY CYLINDRICAL LOCKSETS 5300 SERIES CATALOG LOCK CYLINDRICAL

Pre-Hanging Information

HEAVY-DUTY GRADE 1 KEY-IN-KNOB LOCKSET 5400 SERIES CATALOG LOCK KEY-IN-KNOB

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

4000 Series. The Gainsborough 4000 Series Heavy Duty Cylindrical Locksets KEY IN KNOB LOCKSETS

DIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.

Section B. DEADBOLT ENTRANCE SETS general information. Deadbolt & Mortise Entry Sets. A deadbolt entry set includes:

S O L I D B R O N Z E H A R D W A R E the beauty of fine design, the eternity of solid bronze M A R S T O N SOLID BRONZE

COMMERCIAL DOORS, FRAMES AND HARDWARE

INPACT 94 and 95. Exit device

Cross bar. Exit devices

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Finish Hardware. Contents. Section 10

ED3000 Series. Exit Device Parts Manual

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

6200 Series. System Components Series Electric Strikes

Seamed Edge Doors 1000 Series

Stainless Steel Continuous Hinges

6200 Series. Strikes for mortise or cylindrical devices. Features and benefits. Overview. Non handed design provides greater flexibility

THIS PAGE INTENTIONALLY LEFT BLANK

This section describes the design requirements and materials/products for door hardware.

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

INPACT 94 AND 95 Series Exit Device

BEFORE STARTING INSTALLATION

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Metal Sound Retardant Door Hardware Information Bulletin

930 Series Mortice Exit Device

Mortise Locks. European Mortise Locks Series EML Features Ordering String Functions Trim Sets European Profile Cylinders Specifications

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

No. 059FL. No. 251FL. No. 260FL. No. 305RE. Etruscan Bronze. Florentine Brass. Siena Brass (D) All designs available in these finishes.

MEDIUM DUTY LOCKS - LEVERS. Distributed By. DH Pace National Key Service Center DHPace.

Victory Fire Door Inspections

INTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Exit Devices & Door Locks For Severe Windstorm & Hurricane Doors

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

Your global resource for quality commercial door hardware. Euroline Catalog Euroline Catalog

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

98/ Customer Service # Dogging Key (use to lock down pushbar)

Contents. The undisputed leader in door accessory hardware /ING BuyLine 2600

LT Series. Decorative tubular locks

ARCHITECTURAL DOOR HARDWARE ROLLER LATCHES, PADDLE HANDLES, DOOR HANDLES & BARS CATALOG

Entry Mortise Lock Set Lever to Lever

PD5000 Sliding/Pocket Door Locks

Mortise Locks 185 Series

DIVISION Hardware

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

4000 Series MS Deadlock Strikes

Passage Mortise Lock Set Lever to Lever

OFFSET PIVOTS STOREFRONT HARDWARE

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

Door Thickness For Cylindrical Door Locks with PB-CW PB-CW S-CW BZ-CW 612

SECTION FINISH HARDWARE

Transcription:

World s Leading Manufacturer Of Traffic Doors Supplemental Instructions for the Single and Double Door Order Form

World s Leading Manufacturer Of Traffic Doors 2809 SW th Street Redmond, OR 97756 Phone: -800-57-6856 FA: -800-285-026 ) DATE - Fill in the Date that the Order is completed. QUOTATION / ORDER - Check if the Order is for a Quote or an Actual Order. 2) FINISHED OPENING SIZE (FOS) - Input your desired Finished Opening Size, (see Figures & 2). The Door Panel will be constructed using the FOS Dimensions provided on the order form, therefore it is very critical that these measurements be accurate. Select Single Panel or Double Panel ROUGH OPENING SIZE - If you are Ordering a Frame for your opening you must have adequate clearance for the frame to fit within the rough opening, see Figures & 2. Butt Style Frames require a minimum clearance of -/ (2-/8 Ea. Side) in width, and a minimum clearance of 2-/8 in height, See Figure. Wrap Style Frames require a minimum clearance of in width and a minimum clearance of / in height, See Figure 2. Wall Thickness Jamb Width ) MODEL - N/A This is a supplemental instruction booklet for the CR00 Order Form, covering Single & Double Panels. CR00 Corrosion Resistant Panels are NOT Intended for Exterior Use! ROUGH OPENING SIZE (Finished Opening + -/ in Width & 2-/8 in Height) FINISHED OPENING SIZE Frame (Butt Style) CR00 Panel Figure ROUGH OPENING SIZE (Finished Opening + in Width & / in Height FINISHED OPENING SIZE Frame (Wrap Style) CR00 Panel Figure 2 Wall Thickness Jamb Width ) PANEL COLOR - Indicate your choice color from the available options below: Forest Green Navy Cloud Grey Beige Jade Arctic White Choc. Brown Burgundy Cadet Blue Black Med. Brown Royal Blue Metallic Grey Red 5) QUANTITY - Input the desired number of identical panels entered on this order form. 6) FRAME - If you are not ordering a Frame select Door ONLY NO FRAME. This selection requires Hinge and Strike Locations, refer to Figure in Section 8 (Hinges). If your application requires a frame you must select an FRP Frame or a Stainless Steel Frame For both Styles of Frames you must select Mounting Style, Hand & Profile. Mounting Style - Select Butt or Wrap To determine which mounting method best suits your needs please refer to Figures & 2 at left. Profile - See Figure for FRP & Figure for Stainless Steel NOTE: Some Masonry Conditions Require a Header on the Frame. Select Header on Frame if this condition applies. WALL Thickness is required information for either Frame and is crucial in the construction of your frame, See Figures & 2. Please provide wall thickness information in inches. Hand - Select Left Hand, Right Hand, Left Hand Reverse, Right Hand Reverse, Double IN or Double OUT. To avoid confusion please refer to Figure 8 in Section 7 (Page 2), use Figures 9 & 0 for Double Panels. The Hand Selection on the Frame must match the Swing Selection for the Door. Anchor Style - See Figures 5 & 6 (Page 2) for Anchor Details. Specify New Construction or Existing Construction 5 8 2 Single Rabbet STANDARD FRP FRAME PROFILES Double Rabbet Figure Drywall Single Rabbet THROAT Page CR00 Supplemental Instruction Booklet 5 8 5 8 2 8 2 Double Rabbet (Large Throat) 5 Double Rabbet Page STANDARD STAINLESS STEEL FRAME PROFILES Figure 6) FRAMES Continued on Page 2

6) FRAME (Continued) - Anchor Details for FRP & Stainless Steel Frames. SS Plate Reinforcement /8 SS Sleeve Anchor Page 2 CR00 Supplemental Instruction Booklet World s Leading Manufacturer Of Traffic Doors 2809 SW th Street Redmond, OR 97756 Phone: -800-57-6856 FA: -800-285-026 This is a supplemental instruction booklet for the CR00 Order Form, covering Single & Double Panels. CR00 Corrosion Resistant Panels are NOT Intended for Exterior Use! 7) DOOR SWING - This portion is Extremely Critical in the correct production of your door/doors. See Figure 8 for descriptions of Swings on Single Panels and Figures 9 & 0 for descriptions of Swings on Double Panels. Select the desired swing on the order form. EISTING MASONRY ANCHOR FRP FRAME ANCHOR DETAIL Figure 5 LH Left Hand RH Right Hand MASONRY TEE PUNCHED & DIMPLED FACE ANCHOR ADJUSTABLE LOOP ANCHOR LHR Left Hand Reverse RHR Right Hand Reverse = Keyed Side All Views Are From KEYED Side of Door Figure 8 METAL STUD TRUSS TYPE ADJUSTABLE FLOOR CLIP WELDED FLOOR CLIP Figure 9 If you are Ordering Double Doors you must indicate the Inactive Panel ( See Figure 0) or select Both Panels Active (See Figure 9). Right Hand Active Left Hand Active EP BOLT SPACER CHANNEL STUD Z CLIP STUD CLIP STAINLESS STEEL FRAME ANCHOR DETAILS Figure 6 Page 2 Left Hand Active Figure 0 Right Hand Active

World s Leading Manufacturer Of Traffic Doors 2809 SW th Street Redmond, OR 97756 Phone: -800-57-6856 FA: -800-285-026 8) HINGES - Select NONE if you Do Not require Hinges or Prep. If you require Hinges or Hinge Prep select from the following: CD000 - Standard -/ x -/ Mortise Hinges. Stanley FBB9 - Premium -/ x -/ Mortise Hinges. Hinge Prep Only You must provide the following for Hinge Prep: a. Hardware Brand, Model & Size b. Hardware Locations (See Figure ) Continuous for continuous Piano Style Hinge. Select Hager 790-909 for Standard Hinge or Other If you Select Other, you must provide the following: a. Hardware Brand & Model IMPORTANT NOTE: If you are ordering for Hinge Prep Only, or Frame is Provided by Others, or you are replacing existing doors, you must provide accurate dimensions of all hardware locations. Dimensions must be taken from the top of the panel to the top of the Hinges, and from the top of the panel to the of any Lock Sets and Levers, see Figure. If you are measuring a Frame and/or the Door Panel is not available refer to Figure 2. Deadbolt Spacing (Only if Deadbolt is used) This is a supplemental instruction booklet for the CR00 Order Form, covering Single & Double Panels. CR00 Corrosion Resistant Panels are NOT Intended for Exterior Use! s indicate Required Dimensions! C L C L Figure st Hinge 2nd Hinge rd Hinge IMPORTANT: A th Hinge is Required on Door Panels 7-0 and Taller th Hinge NOTE: If you need to take measurements from the inside of the frame you must Subtract /8 to match any measurements that would be taken from the top of the door panel. /8 Gap between Top of Door Panel & inside of Frame Door Panel Figure 2 Header Frame Page 9) LOCKSETS - Select NONE, NONE with Prep or one of the Passage Sets/Lock Sets listed below. If you select NONE with Prep, you must provide the following information before production can begin: a. Location of Hardware (See Figure ) b. Brand of Hardware c. Model Number d. Backset e. Bore Please provide a template if available. For descriptions of Passage Sets, Lock Sets and Deadbolts, See Figures a, b & c. IMPORTANT: If Selecting Prep for Cylindrical Lock, Measure from inside top of frame... to the of the Strike Plate. NOTE: Chase Doors does not Prep for Mortise Locks. We will install customers Mortise Lock if the actual Hardware is provided prior to production! Figure C L LC Strike Plate Frame Cylindrical Passage/Lock Sets NON-FERROUS Brushed Chrome Finish (26D) ANSI Passage Latch (Non-Keyed) F75 STANDARD PREMIUM CD2000 D0 Both knobs and levers always unlocked. Page CR00 Supplemental Instruction Booklet Entrance Lock (Single Keyed Lock) F82 STANDARD PREMIUM CD200 D5 Turn/Push-Button locking: pushing and turning button locks outside knob/lever requiring use of key until button is manually unlocked. Push-Button Locking: pushing button locks outside knob/lever until unlocked by key or by turning inside knob/lever. SPECIAL ORDER ITEM Vestibule Lock (Double Keyed Lock) F88 STANDARD PREMIUM Not Available D60 Unlocked by key from outside when outside knob/lever is locked by key in inside knob/lever. Inside knob/lever is always unlocked. Figure a 9) LOCKSETS Continued on Page

9) LOCKSETS - Continued from Page SCHLAGE L900 L9050 L9060 SCHLAGE B660 B662 SCHLAGE L Series Passage/Lock Sets Passage Latch (Non-Keyed Lock) Latchbolt retracted by lever or knob from either side at all times. Office & Inner Entry (Keyed Lock) F0 Latchbolt retracted by lever or knob from either side unless outside is made inoperative by key outside or by rotating inside turn piece. When outside is locked, latchbolt is retracted by key outside or by lever or knob inside. Outside lever or knob remains locked until thumbturn is returned to vertical or by counter clockwise rotation of key. Auxiliary latch deadlocks latchbolt when door is closed. Apartment Entrance (Keyed Lock) F09 Latchbolt retracted by lever or knob from either side unless outside is locked by key from inside. When locked, latchbolt retracted by key outside or lever or knob inside. Auxiliary latch deadlocks latchbolt when door is closed. Figure b SCHLAGE B Series Deadbolts Single Cylinder Deadbolt Deadbolt thrown or retracted by key from outside or by inside turn unit. Bolt automatically deadlocks when fully thrown. Double Cylinder Deadbolt ANSI F0 ANSI E5 E Deadbolt thrown or retracted by key from either side. Bolt automatically deadlocks when full thrown. Figure c 9) WINDOWS (Vision Light/Vision Panel) - Select the size of window that you require, See Figure 5. Select NONE if you do not require a window. Select a Frame Material a. Stainless Steel 0 # Brush Finish Available in the following sizes: ) 6 x6 2) 0 x0 ) 8 x8 ) x 5) x0 6) x6 Select a Frame Mounting method for Stainless Steel Frames Only (See Figure 6) ) Surface Mount (Standard) 2) Flush Mount (Stainless Steel ONLY) b. Injection Molded ABS Frame (Black) Available in the following sizes: ) 0 x0 2) x ) x0 NOTE: ABS Frames are Surface Mounted ONLY! (See Figure 6) Select a Glass for your Window a. Tempered Glass (Not Available with ABS Frame) b. Polycarbonate c. Wire Glass (Not Available with ABS Frame) Page 0) WINDOWS (Vision Light/Vision Panel) - Continued 0 6 58 * * 0 6 Page CR00 Supplemental Instruction Booklet World s Leading Manufacturer Of Traffic Doors 2809 SW th Street Redmond, OR 97756 Phone: -800-57-6856 FA: -800-285-026 This is a supplemental instruction booklet for the CR00 Order Form, covering Single & Double Panels. CR00 Corrosion Resistant Panels are NOT Intended for Exterior Use! ) OPTIONS - Chase Doors offers several options for the CR00. You may select from any of the following: Kickplates - Select Polyethylene or Stainless Steel 8 NONE 0 x 0 8 x 8 x 6 2 6 2 x 0 x 6 6 x 6 0 x 0 AVAILABLE WINDOW SIZES * NOT Available on 0 or Panels ** Only Available with ABS Frame *** Only Available with Stainless Steel Frame Figure 5 Surface Mounted Flush Mounted Surface Mounted Stainless Steel Stainless Steel Black ABS FRAME MOUNTING OPTIONS Figure 6 Select a Size: Polyethylene Available Heights: 6,, 8, & 6 6 Stainless Steel Available Heights:, 8, & 6 Select a Color (Polyethylene Plates Only): See Page 2, Section Panel Color for available colors. Select Both Sides or One Side - If you select One Side you must specify which side of the door you would like your Kickplate placed. Select Push Side or Pull Side (See Figure 7) Pull Side Push Side *** *** *** Pull Side IMPORTANT NOTE: Price reflects One Kickplate on One Side of One Panel Only. Push Side Figure 7 ) OPTIONS Continued on Page 5 * 0 **

0) OPTIONS - Continued from Page Push Plate - Select Polyethylene or Stainless Steel Choose a Color for Polyethylene Push Plate Only Pull Handle - Only available in Stainless Steel Polyethylene Push Plate Stainless Steel Push Plate Figure 8 Door Closers CD000 is Standard and does not have SRI coating. LCN0 is Premium and has SRI coating. LCN0H is Premium with Hold Open Stainless Steel Pull Handle Figure 9 Exit Device - Choose the Rim Device or the Surface Mounted Vertical Rod Device, See Figure 20. Von Duprin 98 & 99 Series Rim Device 0 gauge Stainless Steel Non Handed / Throw, Latch bolt Hex Key Dogging Von Duprin 98 & 99 Series Surface Mounted Vertical Rod Device Non Handed 5/8 Throw, Latch Bolt Hex Key Dogging Figure 20 Closer Rim Device Surface Mounted Vertical Rod Device Trim Options - Standard Trims are shown in Figure 2 with Sizes & Descriptions. Select One () if applicable. Louver - 0 Stainless Steel w/ Satin Finish is standard. Specify SIZE. Specify Size by Width (W) then Height (H), See Figure 22. NOTE: Stainless Steel Louvers are Special Order Items and Require Extended Lead Times! HEIGHT WIDTH Stainless Steel Louver Figure 22 Astragal Select T Style, Double Active Split or Custom. Inactive Panel Door Panel T Style Astragal Double Active Astragal Figure 2 Flush/Surface Bolts Select NONE, Surface Bolt or Flush Bolt. Select Top Mount, Bottom Mount or Both. Select a Material & Finish Standard (Brass w/ Chromium Finish) or Stainless Steel Figure 2 Surface Bolt Active Panel Door Panel Flush Bolt Sweep - Select / or / for Standard Sweep. Select Automatic for an Automatic Sweep, See Figure 25. Page 5 CR00 Supplemental Instruction Booklet World s Leading Manufacturer Of Traffic Doors 2809 SW th Street Redmond, OR 97756 Phone: -800-57-6856 FA: -800-285-026 This is a supplemental instruction booklet for the CR00 Order Form, covering Single & Double Panels. CR00 Corrosion Resistant Panels are NOT Intended for Exterior Use! Select a size (Flush Bolts ONLY) Longer lengths are recommended for taller doors. Trim Description Plate Size Grip Projection ANSI Function Cylinder Type 990NL-V x-/6 x/ 5-/ 0 Rim 990TP-V x-/6 x/ 5-/ 05 Rim Figure 2 992L-V 2-5/8 x0-5/8 x/ -/ 2-/ 08 Rim FFL Page 5 / / / Sweep / Sweep Automatic Sweep Figure 25 Stainless Steel Capping - Used for Doors that are cut to a Custom Width. Capping is Flush Mounted on the Leading Edge, See Figure 26. 8 Gauge Stainless Steel Capping (Flush) Figure 26 FFL