FLUXUS G. Non-Invasive Gas Flow Measurement. Measure from outside what s flowing inside. Gas Storage Facilities. Gas Transmission

Similar documents
Technical Specification FLUXUS ADM 8x27

Technical Specification FLUXUS ADM 8127B

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Technical specification FLUXUS F401 H2O

Technical Specification FLUXUS G601

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Technical Specification FLUXUS F601

Advancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017

Technical Specification FLUXUS F601

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Technical specification FLUXUS F601

Technical specification FLUXUS WD

LST100 Ultrasonic level transmitter for upstream oil and gas

SITRANS LR 300: High Performance Radar for Level Measurement

Model Sono-Trak Transit Time

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

DigitalFlow TM CTF878

The Probe KK&S INSTRUMENTS - April / June 2013

Advanced Test Equipment Rentals ATEC (2832) Clamp-on Ultrasonic Flow Meter Family

Meters. Surveillance on demand.

Applications Features

Technical Specification FLUXUS F608**-F2

OPTIFLUX 5000 Technical Datasheet

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

deltawavec deltawavec deltawavec-f stationary deltawavec-p portable

SITRANS L Level instruments

Product data sheet Palas Fidas 200 E

Coriolis Massflowmeter

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

FH CMF Coriolis Mass Flow Meters

UIM-4F. UIM-4F for Custody Transfer Measurement Four Paths for Enhanced Accuracy and Reliability

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

OPTITEMP TT 20 Technical Datasheet

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

The transducer component converts the measured signal and displays the actual value.

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

ULTRASONIC FLOW METER FT101

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

Level Measurement With REFLEX RADAR

Proven Measurement for A World of Applications

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Ultrasonic level transmitter, non-contact

Level Measurement With REFLEX RADAR

OPTIFLUX 5000 Technical Datasheet

Advanced instrumentation solutions crafted with highest precision

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

INLINE flowmeter for continuous flow measurement

Specification DataFile

SERVOPRO MultiExact PROCESS ANALYSERS APPLICATIONS FEATURES

Liquid Ultrasonic Flow Meters

USM GT400 Ultrasonic Flowmeter

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

INDUSTRIAL VIBRATION SENSOR SELECTION MADE EASY

Coriolis Massflowmeter

Technical specification PIOX S721SA

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Technical specification PIOX R400-*CTF

Magnetostrictive Level Transmitter

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

Proximity Sensors Ultrasonic Precision Proximity Sensors

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

OPTIFLUX 1000 Technical Datasheet

mass flowmeter for compressed air

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

ClampOn DSP-06 Particle Monitor

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

4.00 ULTRASONIC ANALYZER

Ambient Conditions. Operating Conditions. Pressure

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

INLINE flowmeter for continuous flow measurement

DigitalFlow DF868. Panametrics Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Market leader in consistency control. Metso Blade Consistency Transmitter

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Activating Your Ideas. In Stainless Steel Pipe

REFLEX RADAR INDICATOR

wprime TM Series 280W-CI ULTRASONIC WATER METER

Level Measurement Products Installation Considerations-Radar

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

OPTITEMP. Compact sensors

LF Conductivity Measuring Probe

Polymer Electric. Product information. Ultrasonic Industrial Sensor USi

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Ceramax CPS341D. Technical Information

Submersible pressure sensor For water and wastewater Model LW-1

Technical specification PIOX S721SA. Ultrasonic measurement of sulfuric acid. Features. Applications

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

INSERTION paddle wheel flowmeter for continuous flow measurement

Beamex MC5-IS INTRINSICALLY SAFE MULTIFUNCTION CALIBRATOR. Made for extreme environments

Process Protection Acoustic sensors for pump monitoring

Design and applications

Ultrasonic Transmitters vs. Guided Wave Radar for Level Measurement

ICARUS ELECTRONIC GAS VOLUME CONVERTER

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Transcription:

FLUXUS G Non-Invasive Gas Flow Measurement Gas Storage Facilities Gas Transmission Natural Gas Extraction Chemical Industry Petrochemical Industry Offshore Manufacturing Industry Measure from outside what s flowing inside

Non-Invasive Gas Flow Measurement with FLUXUS G BEB FLEXIM's ultrasonic gas flow meters use the proven clamp-on transit-time correlation technique also employed for the F series liquid meters. Special ultrasonic transducers are simply clamped onto the outside of the pipe and never come in contact with the gas. The FLUXUS G series contains a broad variety of transmitters and transducers: from basic models for standard applications up to robust measuring systems for offshore use or for use in hazardous areas. Our tradition is innovation Ever since its inception, FLEXIM has been among the pioneers in the field of ultrasonic flow measurement. Many years of application experience combined with innovative concepts and solutions have allowed FLEXIM to extend the scope of the ultrasonic technology to noninvasive measurement of gases. Now, with the FLUXUS G series, FLEXIM sets a new standard. Special transmission technology combined with powerful software algorithms and intelligent adaptive signal processing gives these instruments the dependability you have come to expect from FLEXIM. 2

Adaptive Signal Processing In order to maximize the signal to noise ratio, an optimized transmission process featuring multipulse excitation was developed. The versatile measurement algorithm automatically adapts to the varying application conditions. Thus, disturbing factors such as beam dispersal and structure-borne pipe noise can be effectively compensated. Wide dynamic range amplifier The FLUXUS G measurement amplifier offers a uniquely wide dynamic range by including various frequency filters which are automatically tuned to the appropriate transducer frequency. This is particularly advantageous in the case of clamp-on ultrasonic gas flow measurement, which has to contend with very low signal levels. The FLUXUS G series instruments use digital signal processing. This enables them to adapt easily to a great variety of measuring tasks. Up to 1000 raw signals per second are transmitted for signal processing and analysis. FLEXIM's signal processing algorithms reflect many years of experience in extracting desired signals and rejecting unwanted noise signals. Thus, even weak signals of only a few μv are reliably detected and processed. BEB Pål Rønning 3

Superior Functionality FLUXUS G represents the ideal solution for non-invasive gas flow measurement. FLEXIM s non-invasive technology is an advantageous and cost-effective alternative to conventional methods, particularly with chemically aggressive, poisonous or high pressure media. With their extremely wide turn-down ratios, the instruments of the FLUXUS G series register even the smallest flows. Non-invasive measurement No contact with the medium, therefore no possibility of chemical attack. No need for expensive special materials (sour gas applications for example) No wear and tear, even with high flow velocities or with gas containing particles No clogging of small bore impulse lines with deposits, condensate, inhibitors, oil vapours, dust (as happens when using impulse lines in the measuring system) Insensitive to dust and humidity 4

No moving mechanical or pressure loaded parts Approved for explosion hazard areas Safe and maintenance-free Measurements can be made even at high operating pressures Unharmed by pressure peaks (for example at the onset of condensation) Transducers are mounted on the pipe Very cost-effective installation Precise, bi-directional flow measurement with high measurement dynamics Easy installation without process interruption Even minute flows are measurable Measurement is unaffected by No welding work gas density, viscosity and composition, dust, humidity, temperature or BEB No risk of leakage pressure Cost-advantageous, especially in Not sensitive to velocity peaks, high-pressure applications and for large pipe diameters swirling flows or transverse flows Long-term stable Absolutely no pressure loss, thus low operating costs measurement results High measurement rate, No pipe diameter reduction, therefore no pipe clogging fast response time 5

Technical Data Ultrasonic flow meters natively measure the actual volumetric flow. The transmitters feature an integrated flow computer which makes use of external temperature and pressure data to convert the actual volumetric flow into standard volume (mass) flow based on ISO 12213-1. In principle, flow measurement is possible on all types of gases. However, when measuring on metal pipes, a certain minimum pressure is required, depending on the composition of the gas and the pipe material. Plastic pipes will support operation at atmospheric pressure. Our application engineers will be pleased to advise you. The Transit Time Difference Correlation Principle makes use of the fact that the time of flight of an ultrasonic signal is affected by the flow velocity of the carrier medium. Like a swimmer working his way across a flowing river, an ultrasonic signal travels slower upstream than downstream. Our instruments work according to this transit-time principle: an ultrasonic pulse is sent downstream through the medium, another pulse is sent upstream. By measuring the transit-time difference, the flow velocity can be determined. The volumetric flow is then calculated out of the flow velocity and the pipe parameters. General Technical Data Measuring principle: Transit time difference correlation principle Flow velocity: (0.01 to 25) m/s, pipe size dependent Flow sensitivity: 0.025 cm/s Repeatability: 0.15 % of reading ± 0.01 m/s Accuracy Volume flow: (given a fully developed ± 1% to 3 % of reading ± 0.01 m/s, depending on the application rotationally symmetric ± 0.5 % of reading ± 0.01 m/s with process calibration flow profile) Path velocity: ± 0.5 % of reading ± 0.01 m/s Measurable gases: Ratio of the characteristic acoustic impedance of the pipe wall material to that of the gas <3000 Operating pressure: Measurement does not restrict the maximum operating pressure Pipe size range: (7 to 1600) mm Gas temperature: ( 20 to 120) C or ( 40 to 170) C depending on the transducer type 6

Applications Oil and Gas Chemical Industry Measurement on natural gas pipelines Measurement in natural gas storage installations (storage and extraction) Management of gas storage facilities (efficiency maximization, performance optimization, salt cavern leaching) Regulation and control of drilling sites in natural gas extraction Measurement of synthesized gas Gas measurement in the plastics production process (high pressure) Measurement of HCl gas during methanol synthesis Measurement of HCl gas during the production of Macrolon Control of compressor stations Dimensioning of extraction sites and drilling probes (efficiency maximization) Measurement of sour gas Measurement for the gas supply industry Measurement of injection gas in the petroleum industry Allocation and checkmetering Inventory control / Lost and unaccounted for gas analysis Measurement of injection media in gas processing (monoethylamine, TEG, etc.) with upgraded instrument. Ask FLEXIM! Manufacturing industry Measurement of compressed air Service Supervision of permanently installed meters Error diagnostics Service and maintenance Gas storage facility Kalle, Germany, RWE 7

The Transmitters A FLUXUS G for all purposes Whether for portable use, for rackmounting or for permanent installation, or even for offshore use: FLEXIM offers the appropriate FLUXUS G to meet each measurement challenge. ATEX and FM certified measurement systems for use in hazardous areas are available. Versatile process interfaces assure optimal integration into the user's process. Guaranteed user friendly No complex and elaborate instructions are required in order to use the intuitively structured menu of the FLUXUS G. The pipe and material parameters are easily entered, thanks to the internal media and materials data bank. Explosion-proof instruments can be operated without opening the housing and without requiring any additional devices. Technical Data Operating temperature: Measuring channels: Protection degree acc. to EN60529: Explosion protection in: Inputs: Qutputs: Calculation of the standard volume flow according to ISO 12213-1: 8

The Portable All-round Meter FLUXUS G601 The Multi-function Meters FLUXUS G704 / FLUXUS G709 The Explosion-proof Experts FLUXUS G800 / FLUXUS G801 Unmatched in performance, this handy and versatile instrument is ideal in support of service and maintenance activities. It may also be used for the control or even the temporary replacement of permanently installed meters. Permanently installed and freely configurable: The FLUXUS G704 is designed for permanent installation. With its range of electrical inputs and outputs, it can handle a variety of process parameters. Although technically identical to the G704, FLUXUS G709 is designed for permanent installation in 19" rack systems. FLUXUS G800 and G801 are ATEX certified for use in hazardous areas. The especially robust G801 is completely seawater-resistant and therefore ideal for offshore applications. 10 C to 60 C 10 C to 60 C 10 C to 50 C 2 1 or 2 1 or 2 IP65 G704: IP65 G709: IP20 IP66 ATEX Zone 2, FM Class I Div II for G704 ATEX Zone 1 and 2 Standard: Multifunctional: 2 x current, 1 x voltage, 1 x temperature Standard: 2 x current, 2 x binary A variety of combinations are available from 1 current output, 1 binary output (OC). Multifunctional: 2 x current, 2 x binary, 1 x frequency the following: current (0/4 ma to 20 ma), voltage, frequency, pulse, alarm Also available: 1 or 2 binary outputs (relay), 1 binary output (OC) and 1 current output Yes Maximum 4. Available are: temperature (4-wire Pt 100), current, voltage Yes Yes 9

The Transducers Two transducers types providing a uniquely wide application range All FLUXUS G transmitters support both lamb wave and shear wave transducers at all transducer frequencies. In this way the measuring system can be optimized to the process. The Lamb wave transducer is ideal for high velocity gas measurement as found in natural gas pipelines. The shear wave transducer covers a wide range of pipe diameters and wall thicknesses. It s the best choice for mobile measurement and application diagnostics, as well as for thick-wall pipes. Robust construction All FLEXIM clamp-on transducers are watertight and especially made for use in harsh industrial environments. The transducer housings are made of PEEK or PPSU with stainless steel protection caps. Robust construction and rugged wiring guarantee long-term stability and measuring reliability. Paired, calibrated transducers Each pair of transducers has been wet-flow calibrated at the factory. All calibration data is stored in a transducerresident non-volatile memory and is automatically transferred to the transmitter upon connection. Consequently, parameterization errors are eliminated and there is never a need for a zero adjustment. 10

Our application engineers will be glad to offer you expert advice. Call for an application review today! Robust transducer mounting fixtures The Variofix mounting fixtures hold the transducers safely in place and ensure continuous and constant contact pressure between the transducers and the pipe surface, even if temperature variations cause the pipe diameter to change. Made of stainless steel, they are corrosion-proof and wear resistant. The transducers can be removed and remounted onto the Variofix rail without readjustment. The offshore mounting rail is made to meet the highest operational demands right down to the very last bolt. The rail is seawater-proof and provides your transducers the highest protection they deserve. General Technical Data of the Transducers Application range*: Shear wave transducers: Transducers available for diameters from 30 to 1100 mm. A minimal pipe wall thickness is required. Lamb wave transducers: Transducers available for diameters from 7 to 1600 mm and wall thicknesses from 1 to 23 mm. Each transducer type is assigned to a given wall thickness range. Operating temperature: Gas temperature and ambient temperature : between ( 20 to 120) C and ( 40 to 170) C depending on the transducer type. Use in explosion Transducers for ATEX Zone 1 and 2 as well as for FM Div 2 hazard area: available Explosion protection Depends on the transducer type and on the atmosphere type. temperature: The explosion protection range is usually wider than the operating temperature range. Protection degree IP65 or IP67 acc. to EN60529: Material: PPSU or PEEK with stainless steel caps *: the specified range is valid for natural gas in steel pipes, under the conditions defined in the specification sheets. 11

FLEXIM A short portrait For over 15 years FLEXIM has been an active leader in many areas of process instrumentation in both national and international markets. In addition to non-invasive flow measurement systems, FLEXIM specializes in innovative online process analysis using ultrasonic technology and refractometry. Year after year, the Berlin based company continues its substantial investment in research and development in order to maintain and further improve its position as an industry leader. As a result, our customers benefit greatly from our cutting edge patented technology. Competent and professional associates in our sales offices and regional headquarters in Europe and overseas ensure the worldwide distribution of FLEXIM s proven technology and guarantee you qualified service. BUGASV5-1EN Subjet to change without notification. 2009/06 FLEXIM GmbH Berlin, Germany Tel. +49 30 93 66 76-60 Fax +49 30 93 66 76-80 info@flexim.de www.flexim.com FLEXIM AMERICAS Corporation Headquarters 250-V Executive Drive Edgewood, NY 11717 Phone: (631) 492-23 00 Fax: (631) 492-21 17 Toll free: 1-888-852-7473 (North America only) usinfo@flexim.com www.flexim.com FLEXIM Instruments Asia Pte Ltd Singapore Phone: +65 67 94 53 25 Fax: +65 68 62 28 36 asia@flexim.com Shanghai, China Phone: +86 (21) 649 575 20 shanghai@flexim.com