Operating Manual. isolate501

Similar documents
iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

Installation & Operating Manual. iwap202

Safety Manual. Omni-ID UHF Tags

FM Safety Manual. Omni-ID UHF Tags

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

Certificate of Compliance

Analog Universal Module HART for Zone 2 Series 9468/33

iant101 Zone 1 Omni Directional Antenna

IECEx Certificate of Conformity

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

RX Series UL Listed Explosion Proof Antenna Coupler For Hazardous Area Applications Installation & Operation Manual (IOM)

Making Safe Waves in Hazardous Areas

Temperature Input Module for Zone 1 Series 9482/32

Isolators A3/1. Vibration Transducer Supply Unit Series

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

INSTRUCTION MANUAL (ATEX / IECEx)

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Binary Output without Power Supply Series 9176

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Digital Input Output Module for Zone 2 Series 9470/33

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

OPTIWAVE 7300 C Supplementary instructions

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Isolating Repeater Input Series 9163

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Isolators A3/1.

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Optocoupler, Phototransistor Output, ATEX Certified

Hazardous environments

Digital Input Output Module for Zone 2 Series 9470/33

Binary Output Series 9175

DPharp Differential Pressure and Pressure Transmitters

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

IECEx BVS X issue No. :3. Funkwerk Security Communications GmbH John-F. -Ken nedy-stral1e Salzgitter Germany

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

IPJ-A0311-EU1 Threshold-FS Antenna Datasheet

SOLUTIONS BRIEF MOTOTRBO AND SOLAS

Industrial Pressure Transducers

Accutech GP10. Wireless gauge pressure field unit

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Safety in Hazardous Environments

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

FLEX Ex Power Supplies

SOM i.mx6. Regulation Information. Simple. Robust. Computing Solutions. Rev 1.1

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

Accutech DP20. Wireless differential pressure field unit

SET Installation and Operating Instructions. Level switch for two sensors

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Accutech RT10. Wireless RTD temperature field unit

Copyright Teletronics International, Inc. Patent Pending

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

AN5009 Application note

Digital Input Output Module for Zone 1 Series 9470/32

Accutech BR20. DIN rail mounted base radio

Accutech AI10 & AV10. Wireless multi-input field unit

Installation guide 971 SmartRadar LTi

High power radio transmission module MR03 type

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Accutech AP10. Wireless absolute pressure field unit

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

Accutech AM20. Wireless acoustic monitor field unit

3500/64M Dynamic Pressure Monitor

FOUNDATION Fieldbus Junction Box

Assembly. Front view. HiC2441. SL2 1b. Termination Board

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

PTE-C70 Cell Phone Signal Booster User Manual

Fieldbus Isolating Repeater Series 9185/11

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

PRetrans Table of contents

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Accutech TC10. Wireless thermocouple temperature field unit

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Inductive sensor slot-type SI2-K08-AP7

BTM Series Pulsed RF Power Amplifier Modules. Application Note

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

SIMATIC HMI Panel PC Ex OG, Thin Client Ex OG Notes Product Information

SPM-50 RF Spectrum Power Meter PC Software User Manual

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

Transcription:

Operating Manual isolate501

Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21

Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1 Storage of this Manual... 5 2.2 Special Conditions for Safe Use... 5 2.2.1 ATEX/IECEx... 5 2.3 List of Notes... 7 3 Installation and Setting-to-Work... 8 3.1 Input / Output parameters... 8 3.2 isolate501 Mounting and Earthing... 9 3.3 RF Connections... 12 3.4 Connection to a transmitter... 12 3.4.1 Example of RF threshold power calculation... 13 3.5 Connection to an antenna... 13 3.5.1 Example 1... 13 3.5.2 Example 2... 14 4 Intended Purpose Usage... 16 4.1 Transportation and Storage... 16 4.2 Authorized Persons... 16 4.3 Cleaning and Maintenance... 17 4.4 Safety Precautions... 17 4.5 Cleaning and Maintenance Intervals... 17 4.6 Aggressive substances and environments... 17 4.7 Exposure to external stresses... 18 5 Technical Data... 19 6 Label Drawing... 20 7 Manual Revision History... 21 Page 3 of 21

1 Introduction The isolate501 is an ATEX and IECEx approved RF galvanic isolator. For Zone 0/1 and mining applications, the isolate501 must be installed in the safe area. For Zone 2/22 applications, the isolate501 must be mounted in an IECEx/ATEX approved Ex n or Ex e enclosure with minimum IP54 rating while situated in hazardous gas atmospheres and must be mounted in an IECEx/ATEX approved Ex e enclosure with minimum IP54 rating while situated in hazardous dust atmospheres. The isolate501 galvanically isolates circuits in the hazardous area from potentially incendive faults using the intrinsic safety concept. When the isolate501 is connected to source equipment with Um 250V, it blocks DC, low-frequency AC and transient faults from appearing at the output terminal. The isolate501 will allow RF signals at frequencies within its wide pass-band (120MHz - 8GHz) to pass through to its output; these RF signals are incapable of causing ignition if their power level is within that specified in IEC60079-0:2011 Table 4. The galvanically isolated RF output of the isolate501 allows users to use nonhazardous area certified antennas* with their wireless hardware, such as the Extronics iant200 range of high quality rugged outdoor antennas. * Antennas not listed in the Extronics range must be assessed by the user to ensure that they meet the requirements for the installation of equipment in hazardous areas. Page 4 of 21

2 Safety Information and Notes 2.1 Storage of this Manual Keep this user manual safe and in the vicinity of the device. All persons who have to work on or with the device should be advised on where the manual is stored. 2.2 Special Conditions for Safe Use 2.2.1 ATEX/IECEx 2.2.1.1 The RF power input to the device must be limited to defined power levels dependent on the Equipment/Gas Group: Maximum safe input power, defined as in normal operation without user-settable software limits, and must include antenna gain consideration. Group I Group IIC Group IIB Group IIA Group III 6.0W (37.7 dbm) 2.0W (33 dbm) 3.5W (35.4 dbm) 6.0W (37.7 dbm) 6.0W (37.7 dbm) Page 5 of 21

2.2.1.2 2.2.1.3 2.2.1.4 2.2.1.5 2.2.1.6 The product must be mounted such that it is earthed before use in accordance with clause 15 in IEC 60079-0:2011. The product shall be mounted in an IECEx/ATEX approved Ex n or Ex e enclosure with minimum IP54 rating while situated in hazardous gas atmospheres. The product shall be mounted in an IECEx/ATEX approved Ex e enclosure with minimum IP54 rating while situated in hazardous dust atmospheres. No live connections or disconnections of connectors must be made on the product while situated in hazardous area. The product must only be situated in the safe area when providing ia output into mining M1 area. Page 6 of 21

2.3 List of Notes The notes supplied in this chapter provide information on the following. Danger / Warning. o Possible hazard to life or health. Caution o Possible damage to property. Important o Possible damage to enclosure, device or associated equipment. Information o Warning! Notes on the optimum use of the device For Zone 0/1 and mining applications, the isolate501 must only be installed in the safe area. For Zone 2/22 applications, the isolate501 must be mounted in an IECEx/ATEX approved Ex n or Ex e enclosure with minimum IP54 rating while situated in hazardous gas atmospheres and in an IECEx/ATEX approved Ex e enclosure with minimum IP54 rating while situated in hazardous dust atmospheres. Warning! The RF threshold power must be limited to the levels defined in IEC60079-0:2011 Table 4; the isolate501 does not provide any inband RF power limitation. See section 3.4.1 for details. Warning! To maintain safe operation, the isolate501 MUST be earthed. Refer to Section 3.2 for details. Warning! The antennas connected to the isolate501 must be installed in accordance with the earthing requirements of IEC60079-14:2014 clause 16.2.3. Warning! The isolate501 does not contain any user-serviceable parts. Any attempt to open the unit may render it unsafe and will void the warranty. Page 7 of 21

3 Installation and Setting-to-Work 3.1 Input / Output parameters The isolate501 has the following input/output parameters: U m =250V rms RF threshold Output Power = Effective RF Transmitter Power Input into the isolate501, multiplied by the antenna gain. The maximum permitted RF Threshold Output Power is dependent upon the Equipment Group in which the antenna is located, as defined in the following table. See section 3.4 for further details. ATEX/IECEx Equipment Group Maximum RF Threshold Power (Watts) Maximum RF Threshold Power (dbm) Mining Group I 6 37.7 Gas Group IIA 6 37.7 Gas Group IIB 3.5 35.4 Gas Group IIC 2 33 Dust Group III 6 37.7 Table 1: Maximum permitted RF Threshold Power Page 8 of 21

3.2 isolate501 Mounting and Earthing Warning! For Zone 0/1 and mining applications, the isolate501 must only be installed in the safe area. For Zone 2/22 applications, the isolate501 must be mounted in an IECEx/ATEX approved Ex n or Ex e enclosure with minimum IP54 rating while situated in hazardous gas atmospheres and in an IECEx/ATEX approved Ex e enclosure with minimum IP54 rating while situated in hazardous dust atmospheres. Warning! To maintain safe operation, the isolate501 MUST be earthed - see Figure 1. Page 9 of 21

Figure 1: Earthing and Mounting of isolate501 Page 10 of 21

Figure 2: isolate501 Dimensions Page 11 of 21

3.3 RF Connections The isolate501 is fitted with two SMA female connectors, one at each end. The isolate501 is a totally bi-directional device, and therefore either connector can function as the input or output. 3.4 Connection to a transmitter The isolate501 may be connected to any radio transmitter operating within its passband. It is the responsibility of the installer to ensure that the following requirements are met: 1. The RF threshold power radiated from the antenna must be limited to the levels shown in Table 1. The calculation of this should take into account the power output of the transmitter (as specified by the manufacturer in normal operation) and the gain of the antenna. It is permissible to consider losses in the cable in this calculation. 2. It is permissible for the maximum power output of the transmitter to be limited by a software setting, but it must not be possible for the end-user to override this. 3. Consideration of fault conditions in the transmitter is not necessary when calculating RF threshold power. The transmitter s maximum RF output power should be taken from the transmitter manufacturer s datasheet in normal operation, i.e. the maximum value of RF output power than can be set by the user. Page 12 of 21

3.4.1 Example of RF threshold power calculation The following example shows how the RF threshold power may be calculated: Maximum transmitter output power (from transmitter datasheet) = 20dBm (100mW) Coaxial cable loss = 2dB Antenna gain = 5dBi Threshold power = 20dBm 2dB + 5dBi Threshold power = 23dBm (200mW) 3.5 Connection to an antenna Warning! The antennas connected to the isolate501 must be installed in accordance with the earthing requirements of IEC60079-14:2014 clause 16.2.3. 3.5.1 Example 1 The conductive parts of the antenna must be isolated by at least 500Vrms from nearby conductive structures, to prevent hazardous earth currents from flowing in the coaxial cable. It is the responsibility of the installer to perform the necessary tests to verify this. Note: As the isolate501 must be earthed, the return path of the RF output connector will also be at earth potential. Therefore the verification of isolation of the antenna from earth must only be carried out when the antenna and isolate501 are not connected. Page 13 of 21

3.5.2 Example 2 When the isolate501 is installed inside an earthed enclosure, which has a single connection to earth, and the antennas are mounted to this enclosure, the antennas do not require 500V isolation from earth (as it may be earthed through the enclosure to the single earth point along with the isolate501) For more guidance consult IEC60079-14:2014 clause 16.2.3 Page 14 of 21

Page 15 of 21 Figure 3: Electrical Installation

4 Intended Purpose Usage Important Before setting the units to work, read the technical documentation carefully. Important The latest version of the technical documentation or the corresponding technical supplements is valid in each case. The isolate501 is built using modern components and is extremely reliable in operation; however it must only be used for its intended purpose. Please note that the intended purpose also includes compliance with the instructions issued by the manufacturer for installation, setting up and service. Any other use is regarded as conflicting with the intended purpose. The manufacturer is not liable for any subsequent damage resulting from such inadmissible use. The user bears the sole risk in such cases. 4.1 Transportation and Storage All isolate501 devices must be so transported and stored that they are not subjected to any excessive mechanical stresses. 4.2 Authorized Persons Only persons trained for the purpose are authorized to handle the isolate501; they must be familiar with the unit and must be aware of the Page 16 of 21

regulation and provisions required for explosion protection as well as the relevant accident prevention regulations. 4.3 Cleaning and Maintenance The isolate501 and all its components require no maintenance. All work on the isolate501 by personnel who are not expressly qualified for such activities will cause the Ex approval and the guarantee to become void. 4.4 Safety Precautions Important For the installation, maintenance and cleaning of the units, it is absolutely necessary to observe the applicable regulations and provisions concerned with explosion protection (IEC 60079-14), as well as the Accident Prevention Regulations. 4.5 Cleaning and Maintenance Intervals The cleaning intervals depend on the environment where the system is installed. 4.6 Aggressive substances and environments The isolate501 is not designed to come into contact with aggressive substances or environments, please be aware that additional protection may be required. Page 17 of 21

4.7 Exposure to external stresses The isolate501 is not designed to be subjected to excessive stresses e.g. vibration, heat, impact. Additional protection is required to protect against these external stresses. The isolate501 will require additional protection if it is installed in a location where it may be subjected to damage. Page 18 of 21

5 Technical Data Certification Type Maximum Input / Output Power Enclosure Material Environmental Dimensions (w x h x d) Weight RF Connections Ex na [Ex ia Ga] IIC T6 Gc Ex ic [Ex ia Da] IIIC T85 C Dc [Ex ia Ma] I II 3 (1) G D I (M1) ATEX/IECEx Maximum RF Maximum RF Equipment Threshold Power Threshold Power Group (Watts) (dbm) Mining Group I 6 37.7 Gas Group IIA 6 37.7 Gas Group IIB 3.5 35.4 Gas Group IIC 2 33 Dust Group III 6 37.7 Aluminium with chromate finish Ambient temperature: -40ºC to +80ºC Relative humidity; 0 to 95%, non-condensing 38.4 x 28 x 14.4 mm (57 mm including SMA connectors) 37g SMA Female Certification TRAC15ATEX0050X, IECEx TRC 15.0015X 1 Please note that it is the customers responsibility to ensure the maximum values for RF Threshold power as per Table 4.0 of IEC 60079-0:2011 are not exceeded. The maximum RF output of the wireless transmitter and antenna gain must be taken into account when installing equipment. Refer to manual for full details. Page 19 of 21

6 Label Drawing Where xxxx = Notified Body Number Page 20 of 21

7 Manual Revision History Revision Description Date By 1.0 Initial release of manual 29/09/2015 DC Page 21 of 21