Ledex Drive Electronics and Coil Suppressors

Similar documents
EM-100 Controller. Installation Precautions. July 2016

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

Polarized, latching hermetically sealed relay Contact arrangement. 3 PDT Coil supply

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

TO-5 RELAYS ESTABLISHED RELIABILITY MILITARY DPDT

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

CENTIGRID ESTABLISHED RELIABILITY RELAYS

AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions

RC NETWORKS SALES GUIDE

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

DLVP A OPERATOR S MANUAL

Bulletin 700-R -RM Sealed Switch Relays

Hybrid & Electric Mobility Solutions Electric Vehicle Contactors

Table of Contents. CII Mid-Range Relays

Table of Contents. Kilovac Time Delay Relays

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

HIGH REPEATABILITY, TO-5 RELAYS DPDT

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

CONVENTIONAL TYPE REED RELAY EDR0 SERIES

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

HIGH REPEATABILITY, DC-8 GHz/20Gbps TO-5 RELAYS, DPDT

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

Ledex Tubular Linear Solenoids

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 18 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

SURFACE MOUNT HIGH REPEATABILITY SPDT, BROADBAND 16 GHZ 40GBPS MAGNETIC-LATCHING RF RELAY

PMT/UMT(275) Power Gap Description and Use Application Note

3. Contact Form A: SPST-NO

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Industrial Electronics

RT-3 UNIT RELAY 4-POINT TERMINAL

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

EXPERIMENT 5 : THE DIODE

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Experiment (1) Principles of Switching

PWM CONTROL FOR ELECTROMECHANICAL ACTUATORS. Engineered for higher performance and energy efficiency SPECIALISTS IN ELECTROMAGNETIC DEVICES

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

Analyzing the RCA TX81/82 Horizontal Output Stage

MOSFET as a Switch. MOSFET Characteristics Curves

Power-IO

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

RT-3 UNIT RELAY 4-POINT TERMINAL

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

EXPERIMENT 5 : DIODES AND RECTIFICATION

AUTOMOTIVE RELAY WITH ISO TERMINAL ARRANGEMENT

HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ, 20 Gbps MAGNETIC-LATCHING RF RELAY

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

Principle Of Step-up Chopper

LoopBack Relay. LB363 Series. With Built-in AC Bypass Capacitors. LoopBack Relay, Sensitive Coil, thru-hole with AC Bypass Capacitors

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Electromechanical Printed Circuit Board Relays Application Data

EXPERIMENT 5 : THE DIODE

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

Slim compact safety relay

Application Note # 5438

Chapter 5 Electric Logic Sensors and Actuators

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Considerations for Choosing a Switching Converter

Crane Control Class 7001

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Application Note 1047

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

1a 8A, 1a1b/2a 5A small polarized power relays

SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 4.0 Amperes V RRM V RMS V DC I O I FSM

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

HDB208LS. SURFACE MOUNT GLASS PASSIVATED HIGH EFFICIENCY SILICON RECTIFIER VOLTAGE 1000 Volts CURRENT 2.0 Ampere DB-LS FEATURES MECHANICAL DATA

DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY SEALED

SOLID-STATE RELAYS. DATA SHEET page 1/13. Overview

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Application Alley. Automated Test Equipment - Reed Relays. Pulsed High Current Testing Applications use Reed Relays PARTNER SOLVE DELIVER

TV-15, 30 AMP (1 Form A) Power Relay

HIGH EFFICIENCY SILICON RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 3.0 Amperes I O I 2 T R θ JL R θ JA C J T J T STG

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

LoopBack Relay. GLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

Technical Information General Purpose Relays

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

LOW-PROFILE SURFACE-MOUNT RELAY

* Low cost * Low leakage * Low forward voltage drop * High current capability DO-15 R2500F R3000F R4000F R5000F VRRM VRMS VDC IFSM. I 2 t 3.

Conventional Paper-II-2011 Part-1A

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

Transcription:

Ledex and Coil Suppressors

Ledex Coil Suppressors A voltage is generated by a changing magnetic field in proximity to a current-carrying member. The equation E = -N dø /dt, describes this by saying that the magnitude of the voltage is proportional to the number of turns (N), i.e., of a coil, and the rate of change of a magnetic field. This theory can be easily demonstrated by hooking a coil of wire to a voltmeter and passing a magnet through it. t can be observed that the faster the magnet moves, the higher the voltage. Essentially, the same theory applies when making a generator. Reading the equation the other way suggests that if a voltage is applied to a coil of wire, a change in the magnetic field will occur; i.e., before the voltage is applied, no field exists. Applying a voltage will cause a field to be generated, which will be maintained as long as the voltage is applied. When the voltage is removed, the field must dissipate. Nearly everyone is familiar with spark plugs in gasoline engines. A spark is generated due to a voltage between the contacts which is higher than the dielectric strength of air (which has a dielectric strength of approximately 40 volts/mil). f a spark plug is gapped at 0.025", a voltage of 25 x 40 = 1,000 volts would be necessary to create a dielectric breakdown (spark). How is more than 1,000 volts generated from a 12-volt automobile battery? A coil is charged with 12 volts, and when that voltage is removed, a voltage is created which is dissipated across the gap of the spark plug. This is similar to the operation of a solenoid, except the voltage generated is not useful in a typical solenoid circuit. n most cases, voltages of that great a magnitude would be damaging if not correctly suppressed. Damage can appear as a transfer of material, to welding of hard contacts, to destruction of the switching transistors junction, to even causing a dielectric breakdown of the coil insulation. Ledex coil suppressors minimize contact arcing and suppress the reverse voltage transient to safe levels to protect semiconductor switches. Coil suppressors should be used with all DC solenoid and relay coils to protect associated circuitry and to aid in minimizing electromagnetic interference (emi). Note in Figure 1 that switching on the AC side of the rectifier also slows the drop-out time of a solenoid which is advantageous for improved life of the solenoid. f drop-out time is critical, the solenoid must be switched on the DC side and a high-speed coil suppressor should be connected across the solenoid coil. Refer to Figure 2, which shows a typical coil suppressor connection noting the polarities of the power source and suppressor. Coil suppressors are designed for operation from 55 C to 80 C, with special models designed for 125 C incorporating JAN-rated electronic components. Figure 1. Switching on AC Side Figure 2. Coil Suppressor Connection + DC Source - Control Circuit Oscilloscope trace depicting coil suppression LEFT: Typical trace with capacitor as coil suppressor when 28 volt pulse to inductive load is interrupted. Collapsing magnetic field can generate a spike in excess of 350 volts. Spikes can short capacitors, cause coil burnout or damage other circuit components. RGHT: Same inductive nductive + Arc Supressor - load interrupted under identical conditions, but with coil suppressor No. 122654-00l connected in parallel with coil. Results: Eliminate arcing Extended contact life Minimize transients Protects other circuit components Ledex Solenoids K2

Ledex Coil Suppressors Diode/Capacitor Design Use Type A diode/capacitor designs when the lowest peak reverse voltage is required and when highest operating speed is not necessary. 0.38 (9.65) + - 0.63 (16.0) 2.0 (50.8) MN 0.75 (19.05) 0.19 (4.83) Red dot on unit indicates positive polarity Type A Part Number 122654-001 (not RoHS Compliant) Part Number 122655-001 (not RoHS Compliant) Diode/Capacitor/Zener Design Use these models when highest operating speed is required and when lowest peak reverse voltage rating is not necessary. + - 0.73 (18.54) 0.020 (0.508) (2) Leads 0.44 (11.18) 0.59 (14.99) 0.50 (12.70) Red dot on unit indicates positive polarity 0.38 (9.652) Type C Part Number 190805-001 Part Number 190810-001 PV Use with Maximum Peak nverse Ledex Diode Coil Suppressor Type Operating Voltage Solenoids Capacitor Part (not RoHS Compliant) Voltage (VDC) (VDC) (Size) Type Number Diode/Capacitor 33 1 1-8 A 122654-001 Diode/Capacitor 200 1 1-6 * A 122655-001 Diode/Capacitor/Zener 33 10 1-8 C 190805-001 Diode/Capacitor/Zener 200 36 1-6 * C 190810-001 * Suppression of arcing on hard switch contacts can be supplemented by placing a 0.05 mfd, 200 volt (min.) capacitor across the contacts in addition to our coil suppressor across the load. Ledex Solenoids K3

Ledex Rectifiers Ledex Rectifiers whose DC terminals are connected to the solenoid coil are self suppressing when switched on the AC side of the rectifier. n addition, Ledex rectifiers employ AC line transient suppressors to protect from incoming voltage spikes. Hard contact switches can be supplemented by adding a 0.05 to 0.1 mfd, 200 volt (min.) capacitor across the contacts to further minimize contact arcing. Efficient, light, and exceptionally reliable, Ledex transient protected silicon bridge rectifiers have built-in transient control. High voltage spikes on either AC or DC sides are automatically clipped at 200 volts, protecting the diode cells as well as other circuit components. Our silicon bridge rectifiers are carefully constructed and sealed to meet general requirements of military specification ML-E-5400 on insulation, terminals, vibration, shock, sand and dust, fungus, and salt atmosphere. They are recommended for use with all our electromechanical products, as well as for other systems which may be subjected to high voltage spikes from solenoids, relays and other inductive equipment sharing a common AC line. Storage and ambient temperature range is -55 C to 120 C. Transient Protection One of the early problems associated with the introduction of semiconductors was the destruction of diode cells and other circuit components by transients generated from collapsing magnetic fields. A transient spike in the high resistance direction and beyond the diode PV rating destroys the diode. n a silicon bridge, destruction can occur from transients generated by the inductive load or from other points on the AC system. Consideration should be given to the slower operating speed that results when an inductive load is switched from the AC side. Oscilloscope Trace of Transient Protection LEFT: Actual wave form read from DC output of unprotected full wave silicon bridge rectifier powering an inductive load. To prevent cell destruction, 1500 PV (N-1130) diodes were used. Typical DC output of bridge appears between 0 and 165 volts. Transient from AC Line Transients from the AC line flow through forward direction of two diodes and transient control. Forward direction can withstand the flow. Without protection, flow would be through inverse direction, resulting in diode damage. RGHT: When transient protection circuitry is added to the DC output, the 1400 volt transients are leveled to a safe 250. (These tests were conducted with a Tektronix 535 oscilloscope with 10-to-1 attenuated probe.) Low Resistance, High Current Capacity, Low Voltage Drop High Resistance, Leakage Current Only, High Voltage Drop (Limited by PV) - + + - To prevent current flow in the inverse direction, our silicon rectifiers have a low resistance shunt control built across the DC terminals. t allows the energy of the transient from the AC side to be dissipated through the forward direction of the diodes, protecting the rectifier as well as other circuit components. Transients from the DC side are dissipated directly through the built-in control device. When there is only a minor possibility of transients from the AC side of a silicon rectifier, the need for transient protection may be eliminated by placing the control switch on the AC side. n this way the rectifier is closed only when the load is energized, and the possibility of damage by transients is greatly reduced. Transient from DC Transients from the DC load bypass diodes by going through transient control. f transient control is removed, current path is through inverse direction of diodes. Ledex Solenoids K4

Ledex Rectifiers Octal Plug-n Typical Rectifier Hook-up Part Number A-46502-003 (not RoHS Compliant) Weight: 1 5 8 oz (46 grams) Mates with standard octal tube socket such as Cinch- Jones 8AB or equal. Arc Suppressor AC 0.687 (17.45) - DC 4 5 3 6 2 7 1 8 + DC AC 1.375 (34.93) 0.312 (7.93) 0.093 (2.362) 0.548 (13.92) 0.437 (11.10) 1.087 (27.61) Viewed from base; locate from key Part number 174488-001 is identical to A-46502-003 except that it has no built-in transient protection. f used with an inductive load, switching should be done on the AC side only. To switch on the DC side would require some provision to suppress transients within the 400 PV rating. This model may also be used for applications requiring 220 VAC. TC = Transient Control (Built-n) nput (50-400 Hz) Output VRMS Surge (amps) (VDC) 24 25 for 1 cycle 20 115 25 for 1 cycle 100 140 25 for 1 cycle 124 Current Rating by Duty Cycle 20 to 75 C 100 C Duty Max Current Max Pulse Max Current Max Pulse Cycle % (Amps) Length (Sec) (Amps) Length (Sec) 100 1.8 Cont. 0.75 Cont. 75 2.4 115 1.0 115 50 3.6 100 1.5 100 25 7.2 43 3.0 43 10 7.5 20 4.0 20 Maximum Ratings (25 C Ambient) Rating RMS applied voltage Recurrent peak voltage DC applied voltage Average rectified forward current at 60 Hz Non-repetitive peak surge current for 1 cycle Average transient energy dissipation Peak transient current on DC side of bridge (current spike tp <20 µsec) Operating temperature Value 139 VRMS 184 volts 175 volts 1.8 amp 30 amp 20 joules 1,000 amps -55 C to 115 C Electrical Characteristics Characteristic Typical Max Forward voltage drop ( F = 1.0 amp; T, = 25 C) 1.8 2.2 volts Transient voltage clipping level 273 volts NOTE: The output of the rectifier should not be grounded unless the input is isolated from the power line by a transformer. Ledex Solenoids K5

Ledex Hold-n Circuit Modules These convenient modules provide solutions to applications requiring high starting torque but lower holding torque at the end of the stroke. The modules supply high power to the solenoid to move your load, then reduce the wattage to a lower power level to hold the solenoid in the energized position. These modules use pulse width modulation to reduce the effective voltage to the solenoid to a preselected lower value. AC Hold-n Circuit Module for PWM Operation (Pick and Hold) Part Number 187478-001 (not RoHS Compliant) 2.625 ± 0.030 (66.68 ± 0.76) 2.250 ± 0.020 (57.15 ± 0.51) 6.00 (152.4) Min lead wires For AC input and to solenoid DC Hold-n Module for PWM Operation (Pick and Hold) Part Number 152160-001 (not RoHS Compliant) 0.244 (6.2) 0.770 (19.6) 0.35 (8.9) 0.125 (3.2) 2.500 (63.5) Ø0.185 2 X (4.7) R0.24 2 X (6.1) 1.54 (39.1) 1.56 (39.6) 1 2 3 4 2.28 (57.9) 3.00 (76.2) 4 X #16-32 Screw Terminals 0.32 (8.1) 1.38 (35.1) 1.00 Max. (25.4) Delivers full power for 50 milliseconds (±20%), then reduces voltage to a user-selected range of 10% to 75% full voltage input (approximately 10% factory setting.) Operating voltage is 12-24 VDC input Black ABS plastic housing with terminal strip connections Operating temperature is 0 C to 50 C Suitable for use on Ledex size 5 solenoids or smaller Potentiometer adjustment of hold-in voltage/current Not RoHS compliant nput Voltage Range: 11-26 VDC Maximum Holding Current: 1.0 amps Maximum Pull-n Current: 8.0 amps Minimum Resistance: 3.3 ohms @26 VDC input Holding Current (approximate): V in x duty cycle/coil resistance Maximum Repitition Rate: Once every second Operation: The hold-in module is connected permanently to the solenoid leads. Upon application of DC power to the input terminals, full power is delivered to the solenoid for 50 ms. Power is then reduced automatically to a user-selected value (10 to 75% of full input voltage). This reduced hold-in voltage is maintained until the input voltage to the module is turned off. This action removes power to the solenoid and enables the module for a new cycle of full power and automatic reduction (pick and hold). Height 1.125 ± 0.025 (28.58 ± 0.64) CAUTON SHOCK HAZARD AT ALL LEAD WRES. DO NOT GROUND LEADS. 115 VAC NPUT AT BLACK AND WHTE LEADS; 55 OHM MN. LOAD AT YELLOW AND GREEN LEADS. 1.670 ± 0.025 (42.42 ± 0.64) 1.300 ± 0.025 (33.02 ± 0.64) Ø0.177 Dia thru hole for (33.02) #8 screw, (2) places Built-in full wave rectifier AC line transient protection Delivers full power to solenoid for 125 milliseconds, then reduces voltage to 35% Built-in solenoid coil suppression Rating Min Typical Max Unit nput voltage 95 115 135 Volts AC Energizing pulse width 85 125 175 Millisec resistance 30 Ohms Holding current* 0.9E-2.5 Amps 2.86R Operating temperature 0 +71 C * The holding current following the initial energizing pulse is computed by the above equation where E is the supply voltage (AC) and R is the solenoid resistance. Operation: The hold-in circuit is connected permanently to the solenoid by means of the yellow and green lead wires. Upon application of AC power to the black and white lead wires, full power is applied to the solenoid for approximately 125 ms. The power then automatically drops to provide holding current until the AC power is removed. Ledex Solenoids K6