Chapter-5. Adaptive Fixed Duty Cycle (AFDC) MPPT Algorithm for Photovoltaic System

Similar documents
Chapter-4. Fixed and Variable Step-Size Perturb Voltage MPPT Control for Photovoltaic System

CHAPTER-3 Design Aspects of DC-DC Boost Converter in Solar PV System by MPPT Algorithm

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

Comparative Study of P&O and InC MPPT Algorithms

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

A Current Sensor-less Maximum Power Point Tracking Method for PV

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

Parallel or Standalone Operation of Photovoltaic Cell with MPPT to DC Load

MAXIMUM POWER POINT TRACKING OF PV ARRAYS UNDER PARTIAL SHADING CONDITION USING SEPIC CONVERTER

Maximum Power Point Tracking for Photovoltaic Systems

A NEW APPROACH OF MODELLING, SIMULATION OF MPPT FOR PHOTOVOLTAIC SYSTEM IN SIMULINK MODEL

Maximum Power Point Tracking Simulations for PV Applications Using Matlab Simulink

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by:

Fuzzy Intelligent Controller for the MPPT of a Photovoltaic Module in comparison with Perturb and Observe algorithm

Implementation of P&O MPPT for PV System with using Buck and Buck-Boost Converters

Maximum Power Point Tracking Performance Evaluation of PV micro-inverter under Static and Dynamic Conditions

PV Charger System Using A Synchronous Buck Converter

Maximum Power Point Tracking of Photovoltaic Modules Comparison of Neuro-Fuzzy ANFIS and Artificial Network Controllers Performances

ISSN: X Impact factor: (Volume3, Issue2) Simulation of MPPT based Multi-level CUK converter

Grid Connected photovoltaic system based on Chain cell converter Using Simulink

Design and Analysis of ANFIS Controller to Control Modulation Index of VSI Connected to PV Array

Development of Hybrid MPPT Algorithm for Maximum Power Harvesting under Partial Shading Conditions

Implementation of Buck-Boost Converter with Coupled Inductor for Photo-Voltaic System

DESIGN & SIMULATION OF LOW POWER HOME UTILITY GRID CONNECTED PV SYSTEM USING P&O METHOD

Design and Analysis of Push-pull Converter for Standalone Solar PV System with Modified Incrementalconductance MPPT Algorithm

Improvement of a MPPT Algorithm for PV Systems and Its. Experimental Validation

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Differential Evolution and Genetic Algorithm Based MPPT Controller for Photovoltaic System

CHAPTER 4 PERFORMANCE ANALYSIS OF DERIVED SPV ARRAY CONFIGURATIONS UNDER PARTIAL SHADED CONDITIONS

A Novel Grid Connected PV Micro Inverter

IMPLEMENTATION OF BUCK BOOST CONVERTER WITH COUPLED INDUCTOR FOR PHOTO-VOLTAIC SYSTEM

DESIGN, SIMULATION AND REAL-TIME IMPLEMENTATION OF A MAXIMUM POWER POINT TRACKER FOR PHOTOVOLTAIC SYSTEM

Design and Simulation of a Solar Regulator Based on DC-DC Converters Using a Robust Sliding Mode Controller

MPPT with Z Impedance Booster

Photovoltaic Systems I EE 446/646

Maximum Power Point Tracking Using Ripple Correlation and Incremental Conductance

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

HYBRID SOLAR SYSTEM USING MPPT ALGORITHM FOR SMART DC HOUSE

INCREMENTAL CONDUCTANCE BASED MPPT FOR PV SYSTEM USING BOOST AND SEPIC CONVERTER

Comparison Between Perturb & Observe, Incremental Conductance and Fuzzy Logic MPPT Techniques at Different Weather Conditions

Application of Model Predictive Control in PV-STATCOM for Achieving Faster Response

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

Modeling of PV Interconnected Distribution System using Simulink

MODELING AND SIMULATION OF PHOTOVOLTAIC SYSTEM EMPLOYING PERTURB AND OBSERVE MPPT ALGORITHM AND FUZZY LOGIC CONTROL

Designof PV Cell Using Perturb &Observe and Fuzzy Logic Controller Based Algorithm

CHAPTER 2 LITERATURE SURVEY

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

Sliding-Mode Control Based MPPT for PV systems under Non-Uniform Irradiation

Photovoltaic Maximum Power Point Tracking based on an Adjustable Matched Virtual Load

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

A Fast Converging MPPT Technique for PV System under Fast Varying Solar Irradiation and Load Resistance

Finite Step Model Predictive Control Based Asymmetrical Source Inverter with MPPT Technique

DESIGN AND SIMULATION OF IMPROVED DC- DC CONVERTERS USING SIMULINK FOR GRID CONNECTED PV SYSTEMS

A Hybrid Particle Swarm Optimization Algorithm for Maximum Power Point Tracking of Solar Photovoltaic Systems

Photovoltaic Systems Engineering

A Survey and Simulation of DC-DC Converters using MATLAB SIMULINK & PSPICE

CHAPTER 6 INPUT VOLATGE REGULATION AND EXPERIMENTAL INVESTIGATION OF NON-LINEAR DYNAMICS IN PV SYSTEM

Microcontroller Based MPPT Buck-Boost Converter

Solar Photovoltaic System Modeling and Control

Solar Array Maximum Powerpoint Tracker

MEASURING EFFICIENCY OF BUCK-BOOST CONVERTER USING WITH AND WITHOUT MODIFIED PERTURB AND OBSERVE (P&O) MPPT ALGORITHM OF PHOTO-VOLTAIC (PV) ARRAYS

ABSTRACT AN IMPROVED MAXIMUM POWER POINT TRACKING ALGORITHM USING FUZZY LOGIC CONTROLLER FOR PHOTOVOLTAIC APPLICATIONS

Development of a Fuzzy Logic based Photovoltaic Maximum Power Point Tracking Control System using Boost Converter

IMPLEMENTATION OF MAXIMUM POWER POINT TRACKING ALGORITHM USING RASPBERRY PI

International Journal of Scientific & Engineering Research, Volume 7, Issue 4, April ISSN

The Single Diode Model of I-V and P-V Characteristics using the Lambert W Function

Photovoltaic Power Converter Functional Requirements List and Performance Specifications Date: 11/10/11

Modeling of Multi Junction Solar Cell and MPPT Methods

COMPARATIVE ANALYSIS OF THE PERTURB-AND-OBSERVE AND INCREMENTAL CONDUCTANCE MPPT METHODS

A Novel Asymmetrical Single-Phase Multilevel Inverter Suitable for Hybrid Renewable Energy Sources

A Grid Connected Hybrid Fuel Cell-Po Based Mppt For Partially Shaded Solar Pv System

MATHEMATICAL MODELLING AND SIMULATION OF GRID CONNECTED SOLAR PHOTOVOLTAIC SYSTEM

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 2.114

Converter Topology for PV System with Maximum Power Point Tracking

Hardware Implementation of Maximum Power Point Tracking System using Cuk and Boost Converters

Design and Analysis of Stationary Frame PR Current Controller for Performance Improvement of Grid Tied PV Inverters

[Sathya, 2(11): November, 2013] ISSN: Impact Factor: 1.852

The table below gives some summary facts to the two set of data and show that they correlate to a high degree of the course of a year.

Perturb and Observe Method MATLAB Simulink and Design of PV System Using Buck Boost Converter

Solar Energy Conversion Using Soft Switched Buck Boost Converter for Domestic Applications

In this lab you will build a photovoltaic controller that controls a single panel and optimizes its operating point driving a resistive load.

Because the global warming is increasing and conventional

Maximum Power Point Tracking

Load Controlled Adaptive P&O MPPT Controller PV Energy Systems

CHAPTER 3 MODELLING OF PV SOLAR FARM AS STATCOM

International Journal of Engineering Research ISSN: & Management Technology March-2016 Volume 3, Issue-2

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

INTERNATIONAL JOURNAL OF PROFESSIONAL ENGINEERING STUDIES Volume VI /Issue 5 / SEP 2016

OPTIMAL DIGITAL CONTROL APPROACH FOR MPPT IN PV SYSTEM

Modelling of Photovoltaic power plants in SIMPOW

Improved Maximum Power Point Tracking for Solar PV Module using ANFIS

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Boost Half Bridge Converter with ANN Based MPPT

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

MODELING AND CONTROL OF A SINGLE-PHASE GRID CONNECTED PHOTOVOLTAIC SYSTEM

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

Delhi Technological University (formerly DCE) Delhi-42, India

Modeling and Analysis of Perturb & Observe and Incremental Conductance MPPT Algorithm for PV Array Using CUK Converter

Transcription:

88 Chapter-5 Adaptive Fixed Duty Cycle (AFDC) MPPT Algorithm for Photovoltaic System 5.1 Introduction Optimum power point tracker (OPPT), despite its drawback of low efficiency, is a technique to achieve delivery of power from array to the load. It is need to improve the PV system efficiency. All the MPPT techniques, heather to discuss till now may not work well due to environmental condition, sudden change of reference voltage or current threshold. The proposed AFDC MPPT method surpasses these drawbacks by quick reaction to this operating point. The effectiveness of proposed algorithm in terms of steady-state performance and improved tracking efficiency are discussed in this chapter. 5.2 Adaptive Fixed Duty Cycle (AFDC) Method The AFDC control algorithm uses existing inputs of VSPV MPPT algorithms such as differential power (dp) and differential voltage (dv). The proposed algorithm is fixed perturbations steps depending on the nearness of PV operating voltage with the maximum power point voltage. Even though, it claims to have quick convergence during rapid changes in irradiance and load. Moreover, the proposed algorithm to restore comparing and switching methods with ADFC approach, as shown in Fig. 5.1. 5.3 Model of AFDC Algorithm The output power of the PV array depends upon the solar irradiance and cell temperature. The output power of PV module is given to the grid through the DC-DC

89 boost converter and DC-AC converter (inverter). The PV output voltage and current is given to AFDC MPPT controller as an input. The AFDC MPPT controller generates duty ratio based on the fixed step-size perturb. In this method, the duty cycle is varied accordingly to perturbation voltage and operating point oscillates around the MPPs. By changing duty ratio, it can match the characteristic impedance of the PV array to the load impedance. Therefore, it quickly transferres the maximum power to the load. Fig 5.1: Block diagram of Single Phase Grid Connected PV System with AFDC MPPT Technique. 5.4 AFDC MPPT Algorithm Fig 6.2 shows the association of P and D curve in the photovoltaic system with boost converter as power conditioner. Where, P is represents the photovoltaic output power and D is the duty cycle of DC-DC boost converter.

90 dp dd d( k) d( k 1) (5.1) P D modified as If dp/dd>0 be able to access maximum power point, then the equation (5.1) as dp dd d( k) d( k 1) (5.2) P D Similarly, for dp/dd<0, then the expression is dp dd d( k) d( k 1) (5.3) P D Fig.5.2 Relationship of P and D.

91 The operation of P-D curve start with left area, if dp/dd>0 be capable of access maximum power point (MPP). However, the actual operating point is in the right-hand area, to keep dp/dd<0 to reach maximum power delivery. When the tracking system of dp/dd=0, then, the power reaches maximum point. The algorithm steps are Step 1: Start Step 2: Initialize the value of duty ratio between 0 and 1. Step 3: Measure the values of photovoltaic array voltage and current at k th and k-1 th Instants and compare powers at kth and k-1th instants. Step 4: If dp > 0, slope = 1 and duty cycle is increased by D + c * slope. Step 5: If dp < 0, slope = -1 and duty cycle is decreases by D + c * slope. Step 6: Save present power as previous power (k-1) value. Step 7: Go to Step 3 and repeat the above steps until reaching the Maximum power point Step 8: Stop. 5.5 Flowchart of AFDC MPPT Algorithm The algorithm compares the present power with the previous one and selects the best among them until the required MPPs is reached. The control algorithm flowchart is shown in Fig. 5.3.

92 Fig 5.3 Flowchart of AFDC MPPT Technique

93 5.6 Results and Discussion 5.6.1 Variation of irradiance To show the effectiveness of proposed MPPT algorithm based PV system, the PV module considered for simulation is 100 Watts multi-crystalline PV panel. The mathematical simulation has been carried out by using MATLAB/Simulink. (a) (b) (c) Fig 5.4. AFDC: Waveforms of PV Output (a) Voltage (b) Current (c) Power with Irradiance is 1000 W/m 2 at Temperature is 25 o C.

94 (a) (b) (c) Fig 5.5. AFDC: Waveforms of PV Output (a) Voltage (b) Current (c) Power with Irradiance is 200 W/m 2 at Temperature is 25 o C.

95 (a) (b) (c) Fig 5.6. AFDC: Waveforms of PV Output (a) Voltage (b) Current (c) Power with Irradiance is 1000 W/m 2 at Temperature is 55 o C.

96 (a) (b) (c) Fig 5.7. AFDC: Waveforms of PV Output (a) Voltage (b) Current (c) Power with Different Irradiance at Fixed Temperature is 25 o C.

97 The Simulation parameters and specifications of PV module and boost converter used in this thesis are given in Appendix. From Fig.6.4, it is observed that the performance of the PV output voltage (18.93V), current (4.592A) and power (86.94W) with array irradiance is 1000 W/m 2 at cell temperature is 25 o C. Similarly, from the Fig 6.5, it is observed that the performance of output power and voltage of PV system attains oscillation is significantly more due to low irradiance is 200W/m 2. Simulation results show the performance of the PV system. Fig.5.6 shows the response of PV output voltage, current and power with irradiance is 1000 W/m 2 at cell temperature is 55 o C. It is clear that, the output power of the PV system is little bit reduced as compared to cell temperature of 25 o C. Waveforms obtained from the simulation are shown in Fig.5.7. The individual response of output voltage, current and power is varied with varying different irradiance values of 400 W/m 2, 1000W/m 2 and 800W/m 2 at constant cell temperature is 25 o C. It is clear that, when the PV system operated with low irradiance is 400 W/m 2, the corresponding PV output power is significantly less (12.91W). Similarly, when the PV system operated with high irradiance is 1000 W/m 2, the corresponding PV output power is significantly more (86.29W). Moreover, the tracking efficiency of PV system with proposed MPPT algorithm is 86.29%, respectively. Fig 5.8 shows that, particularly when the solar irradiances is operating at low values, adaptive fixed duty cycle algorithm reaches oscillations is more in PV power output of the PV system. But, when operating at moderate/high values of irradiances, the proposed AFDC control algorithm gives optimal performance in PV output power. The numerical analytic version can be found from Table 5.1, that the output power of the PV system is 86.29 W during the solar irradiance is 1000 W/m 2 at cell temperature is 25 o C. From Table 5.1 it is observed that, when the cell temperature increases the effectiveness of photovoltaic output power is decreased. Similarly, the temperature increases the effectiveness of photovoltaic output voltage is decreased.

98 Whereas, the output current of the photovoltaic system is increased by increases in temperature. The same is observed from Table 5.1. Fig 5.8. AFDC: Simulated Waveforms of PV Output Voltage, Current and Power with Different Irradiance at Fixed Temperature is 25 o C. Table 5.1 AFDC: Evaluation PV Output Voltage, Current and Power with different Temperature at Constant Irradiance condition

99 Table 5.2 AFDC: Evaluation PV Output Voltage, Current and Power with different Irradiance at Constant Temperature condition It is clear that, that the output power of the PV system is 86.29 W during the solar irradiance is 1000 W/m 2 at cell temperature is 25 o C. From Table 5.2 it is observed that, when the solar irradiance vary from low to high, the value of photovoltaic output power is varied low to high. Similarly, the effectiveness of photovoltaic output voltage and current is also varied from low to high, respectively. It is verified that the proposed MPPT algorithm of PV system strategy works well for medium/high irradiance range. Fig.5.9 shows the analytical evaluation of PV output voltage at different irradiance ratings. Fig.5.10 shows the analytical evaluation of PV output current at different irradiance ratings. Similarly, Fig.5.11 shows the analytical evaluation of PV output power at different irradiance ratings.

100 Fig 5.9. Analytical evaluation of PV Output Voltage with Different Irradiances. Fig 5.10. Analytical evaluation of PV Output Current with Different Irradiances.

101 Fig 5.11. Analytical evaluation of PV Output Power with Different Irradiances. Fig 5.12. Analytical evaluation of PV Output Power vs Irradiances with Various Proposed Technique.

102 Table. 5.3 Comparative analysis of Proposed MPPT Techniques Based on the above tabulated numerical analysis, it is clearly noticed that AFDC method performs better than previous methods. From Fig 5.12, compared to the previous methods, AFDC MPPT method is proved to be the best, as it minimises the oscillations and increases the tracking efficiency. It is released in Table 5.3. From Table 5.5, it gives that the power response of the PVS arrangement in terms of settling time at high/low irradiance (1000/200) W/m 2 of AFDC control is settled very quick (i.e. 0.01/0.006 sec) as compare to VSPV MPPT control. Table 5.4 Performance evaluation of Tracking Efficiency (%)

103 Table 5.5 Analysis of Time Response Response Irradiance (W/m 2 ) MPPT Control Methods VSPV AFDC Settling Time 1000 (High) 0.15 0.01 (in sec) 200 (Low) 0.25 0.006 5.6.2 Variation of Load Fig.5.13 shows the ampere-volts curve of PVS with the variation in irradiances. An operating load line produced can be forced on ampere-volts curve when the PVS supplies power to the load. Fig. 5.13. MPP line and load line on the I-V curve for various levels of irradiance. V 1 1 D in V o (5.4)

104 and I 1 1 D in I o 1 R in 1 D R (5.5) (5.6) The relationships of the voltage and current of the DC-DC boost converter between the input and output sides are shown in (5.4) and (5.5). Equation (5.6) shows that the duty cycle can be regulated to impose the input resistance of the converter to be varied until the load line cuts though the I-V curve at MPP. Fig 5.14 Proposed AFDC MPPT Algorithm: Analytical evaluation of Tracking efficiency at various Load Resistance. Fig 5.14 illustrates the investigative representation of tracking efficiency verses Load resistance (omhs). From this analysis, when the load resistance is increased then the tracking efficinecy is decayed parabolically, according to the maximum power theorem. It is clearly observed in Table 5.6.

105 Fig 5.15 VSPV and AFDC MPPT Algorithms: Analytical evaluation of Tracking efficiency at various Load Resistance. Table 5.6 AFDC: Evaluation of PV Output Voltage, Current, Power and Tracking efficiency at different Load Resistance.

106 Fig. 5.15 shows the recital of VSPV and proposed MPPT algorithm at various load conditions. It is clear that from Table.5.6, If the duty cycle is constant, the variation of load resistance is increase (decrease) the voltage and decrease (increase) in current of the photovoltaic system. Though, variation in the voltage and current are alwys in the opposite direction under load variation. 5.6.3 Variation of Duty cycle The variation of the duty cycle changes input voltage of the DC-DC boost converter and therefore the photovoltaic module operating point reponds rapidly and operates near to the new MPP whenever there is variation in solar irradiance. Fig 5.16 AFDC: Simulated relationship of Tracking efficiency vs Duty cycle Fig 5.16 shows the closed loop response for 40% to 60% variation in duty cycle. The results portray that the controller objective are realized for limiting the

107 speed and tracking efficiency deviations in acceptable values. The verification of maximum power point power as observe 86.29W. It is released in Table 5.7. Table 5.7 AFDC: Eavulation PV Output Voltage, Current and Power with different duty cycle 5.6.4 Results of boost converter To validate the performance of the proposed system, simulations are performed with MATLAB/Simulink. On the DC side, the photovoltaic maximum power is successfully injected into the DC-DC boost converter with high tracking efficiency. The DC-DC boost converter of output current (2.14A), voltage (38V) and power (81.32W) are shown in Fig.2.21.

108 (a) (b) (c) Fig. 5.17 Proposed AFDC Algorithm: Simulated waveforms of Boost converter output (a) Current, (b) Voltage and (c) Power.

109 5.6.5 H-bridge inverter and utility grid The power stage of the system proposed is illustrated in Fig. 5.1. Power flows from the photovoltaic module to the grid through the signle phase H-bridge inverter, which operates as a boost converter in each half line cycle, provided that a suitable SPWM control of the four switchs is operated. The steady-state response of grid voltage waform is depicted in Fig.5.18. From Fig 5.18 it is observed that the frequency of grid voltage is maintained at the fundamental frequency (i.e. 50 Hz). Fig.5.18 Steady-state grid voltage 5.7 Conclusions The proposed adaptive fixed duty cycle MPPT algorithm is tested on a closed loop system. The proposed algorithm reduces the oscillation around the MPPs and fast dynamic response involved in the all previous MPPT control techniques. It can be conclude that, the proposed MPPT control algorithm gives improved performance as compared to all other control techniques. Hence, to improve the perfomane of PV system, in terms of increased tracking efficiency and reduced oscillation around MPPs in the output of the PV power during low/medium/high temperature and irradiance regions, AFDC MPPT suits well.