Linear vs. PWM/ Digital Drives

Similar documents
Step vs. Servo Selecting the Best

To understand what makes the DTA-9.4 unique, it s important to compare its design topology with that of conventional amplifiers.

Optimizing Performance Using Slotless Motors. Mark Holcomb, Celera Motion

Application Note # 5438

Installation Tech Note Dallas, Texas

DIGITAL SPINDLE DRIVE TECHNOLOGY ADVANCEMENTS AND PERFORMANCE IMPROVEMENTS

3U High, 19" Drive Rack

Continental Hydraulics Installation Manual CEM-PA-A

XC4e PWM Digital Drive

Bel Canto Design evo Digital Power Processing Amplifier

Feedback Devices. By John Mazurkiewicz. Baldor Electric

Analog Servo Drive 30A8

Analog Servo Drive 20A20

XC4e PWM Digital Drive

Analog Servo Drive 30A8

BSNL TTA Question Paper Control Systems Specialization 2007

High Current High Power OPERATIONAL AMPLIFIER

ME375 Lab Project. Bradley Boane & Jeremy Bourque April 25, 2018

SERVOSTAR S- and CD-series Sine Encoder Feedback

CHAPTER 7 HARDWARE IMPLEMENTATION

Where: (J LM ) is the load inertia referred to the motor shaft. 8.0 CONSIDERATIONS FOR THE CONTROL OF DC MICROMOTORS. 8.

Testing Power Sources for Stability

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Analog Servo Drive 25A20DD

Fluxgate Magnetometer

Analog Servo Drive 30A20AC

Mini-MAG Positioning Products

DC SERVO MOTOR CONTROL SYSTEM

V2018 SPINSTAND AND NEW SERVO-8 SYSTEM

TA330-E01 MEDIUM POWER LINEAR SERVO DRIVE OPERATING MANUAL

Generator Speed Controller Model GSC 1

Hydraulic Valve Interface Products

All Servos are NOT Created Equal

High Power Monolithic OPERATIONAL AMPLIFIER

AxCent Servo Drive A50A100

XC4 PWM Digital Drive

THE NEXT GENERATION AIRBORNE DATA ACQUISITION SYSTEMS. PART 1 - ANTI-ALIASING FILTERS: CHOICES AND SOME LESSONS LEARNED

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

CHAPTER 4 CONTROL ALGORITHM FOR PROPOSED H-BRIDGE MULTILEVEL INVERTER

User s Manual for Integrator Short Pulse ISP16 10JUN2016

ServoStep technology

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

High Current, High Power OPERATIONAL AMPLIFIER

Latest Control Technology in Inverters and Servo Systems

Chapter 2 Analog-to-Digital Conversion...

A Prototype Wire Position Monitoring System

DynaDrive INFORMATION MANUAL SDFP(S)

Chapter 5. Tracking system with MEMS mirror

Npaq Series Drive Racks

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

9 Best Practices for Optimizing Your Signal Generator Part 2 Making Better Measurements

OVEN INDUSTRIES, INC. Model 5C7-362

As delivered power levels approach 200W, sometimes before then, heatsinking issues become a royal pain. PWM is a way to ease this pain.

Differential Amplifiers

Servo System Efficiency. Servo Drive & Servo Motor & Power Supply

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

Variable Speed Brushed DC Motor Drive

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AMP-13 OPERATOR S MANUAL

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

MP W Mono Class D Low-EMI High- Efficiency Audio Amplifier. Application Note

RFID Systems: Radio Architecture

Advanced Motion Control Optimizes Mechanical Micro-Drilling

Mechatronics. Analog and Digital Electronics: Studio Exercises 1 & 2

The Air Bearing Throughput Edge By Kevin McCarthy, Chief Technology Officer

Troubleshooting accelerometer installations

Vibrating Wire Instrumentation

LM675 Power Operational Amplifier

Lecture Fundamentals of Data and signals

Development of Control Algorithm for Ring Laser Gyroscope

10 AMP, 75V, 3 PHASE MOSFET BRUSHLESS MOTOR CONTROLLER

AxCent Servo Drive A25A100

Electronics Design Laboratory Lecture #6. ECEN2270 Electronics Design Laboratory

Servo Loop Bandwidth, Motor Sizing and Power Dissipation. Mark Holcomb Senior Engineer, Motion Control Specialist Celera Motion

RF Generators. Requirements:

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

The Temperature Controlled Window Matt Aldeman and Chase Brill ME 224 June 2003

TECHNICAL PAPER. Smarter Sensors reduce costs for Motion Control Integrators. David Edeal. Introduction

Agilent N3300 Series DC Electronic Loads

ABB flowmeter technology FSM4000 AC-excited magmeter

9 Things to Consider When Specifying Servo Motors

Basic Tuning for the SERVOSTAR 400/600

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

User-selectable output bus voltages for optimized voltage/current matching to load requirements.

Eliminate Pipeline Headaches with New 12-Bit 3Msps SAR ADC by Dave Thomas and William C. Rempfer

LM675 Power Operational Amplifier

Advanced Motion Control Optimizes Laser Micro-Drilling

QUAD 5V RAIL-TO-RAIL PRECISION OPERATIONAL AMPLIFIER

Op Amp Booster Designs

Laboratory 6. Lab 6. Operational Amplifier Circuits. Required Components: op amp 2 1k resistor 4 10k resistors 1 100k resistor 1 0.

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

DSP-Based Simple Technique for Synchronization of 3 phase Alternators with Active and Reactive Power Load Sharing

7I54 MANUAL Six channel 40V 3A Servo motor drive

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

Motion Solutions for Digital Pathology

of harmonic cancellation algorithms The internal model principle enable precision motion control Dynamic control

7I33 / 7I33TA MANUAL Quad analog servo amp interface

Analog Servo Drive. Continuous Current. Features

7I33/7I33T MANUAL Quad analog servo amp interface

Transcription:

APPLICATION NOTE 125 Linear vs. PWM/ Digital Drives INTRODUCTION Selecting the correct drive technology can be a confusing process. Understanding the difference between linear (Class AB) type drives and PWM or digital (Class D) type drives is necessary to determine the technology best suited for a specific actuator or application. Drives are often selected using only one criterion, which may lead to performance or system characteristics that are not optimized for all applications. This application note addresses the difference between linear drive technology and PWM drive technology.

BASIC TECHNOLOGY DIFFERENCES In the past, many brands of linear drives or amplifiers were only Class C-rated. All Trust Automation drives are Class AB-rated. It is important to understand the differences between Class AB, Class C and Class D drives. See the table below for a simple comparison: Class AB Class C Class D Analog Class D Digital Trust Automation s standard linear drives Many older designs for linear drives Trust Automation s custom PWM drives Traditional AC servo drive TYPE OF DRIVE LOW EMI/RFI NO DEAD BAND AT ZERO CROSSING HIGH BANDWIDTH CURRENT LOOP HIGH EFFICIENCY Class AB Class C Class D Analog Class D Digital When evaluating the different technologies, it is important to understand the categories being compared above. The following summarizes these categories and why they are important in machine design. LOW EMI/RFI The majority of modern machinery relies on sensor technology to make process decisions. Most sensors use analog circuitry to evaluate conditions and will either pass this analog signal back to a host computer system for evaluation, or the sensors will perform the evaluation and pass the decision back to the host. Class AB linear drives do not have EMI or RFI noise emissions, improving process throughput and reducing wiring problems in production machines. Understanding this concept is important because these low-level signals are very susceptible to EMI/RFI noise. Signal or clean power cables that pass near motor cables or are attached to the machine chassis can pick up this noise very easily. Once the noise gets into the sensor signals, it will diminish overall system performance. Performance will be degraded because filtering is required in order to remove or reduce the effect of the noise. Filtering always reduces the speed of the circuit. In many cases, this can slow down the acquisition time of a sensor by more then 25 times, resulting in reduced performance and slower throughput of the end process. Noise is also a factor in stable machine operation. Noise will transmit through the air to other control wires and, in many cases, where the control signals are low voltage. The magnitude will be smaller than the original signal on the transmitting side but can still be very large due to the high voltage at which many digital AC servo systems operate. The example below illustrates these properties. (More information is available in Application Note 110.)

BLUE TEST WIRE AROUND MOTOR CABLE PICKUP PLATE 100MM FROM MOTOR ANOTHER VIEW OF 1010MM PICKUP PLATE BASELINE NOISE ON BLUE WIRE YASKAWA SGD DRIVE TA310 DRIVE BASELINE NOISE ON YELLOW PLATE YASKAWA SGD DRIVE TA310 DRIVE A less obvious benefit of using linear drive technology is the ability to use a simplified wiring scheme. The lack of EMI/RFI created by linear drives allows the developer to run motor and sensor cables together in the same cable tracks. This greatly reduces the extra hardware and effort required to manage and control ground loops and ground points for all aspects of the machine that come in contact with either the drives or the motors.

The following charts illustrate additional testing showing graphical representation of noise comparisons between AC Digital Drives and Linear Drives. NO DEAD BAND AT ZERO CROSSING The ability of a stage to position at tolerances below 1 micron can be hindered by the Dead Band at the Zero Current Crossing point in a drive. This also negatively affects settling times in precision applications (stages). Class AB linear drives have no Dead Band at the Zero Current Crossing, contributing to their high performance and very fast settling times. Dead Band causes problems with precision staging and settling because it does not allow the drive to output low levels of current accurately near the zero-crossing point. On most applications, this is the point where the stage is trying to move to its final position or hold position without dithering in place. It is common to find stages using Class C or Class D digital drives performing poorly when the stage is stopped or decelerating to its final position. Good current output control at a low level is vital to maintaining correct relationships in the controllers control loop equations. When using a drive that exhibits Dead Band, the system cannot accurately control small or fine movements, resulting in long settling times. The stage may also buzz or dither in the stationary and holding positions. Linear drive customers have seen an 80% reduction in settling times on some applications by switching from Class D drives to Class AB drives and immediately gain two important advantages: 1. Immediate improved machine performance. 2. Reduced setup and tuning time during manufacturing installation, as well as scheduled maintenance. In one case, a customer who supplies inspection and assembly equipment to the disk drive industry reduced 8 axes of machine setup and tuning from two days to 30 minutes for an application requiring 100 nm-position and settling. This was accomplished by replacing all PWM drives with Class AB drives and updating the tuning parameters.

HIGH BANDWIDTH CURRENT LOOP Current loop precision and speed is the biggest factor in velocity stability and the second biggest factor in stage settling and stability. Class AB drives have the highest performing current loops available of any drive type. The default factory settings are general, resulting in good performance across many types of motors. At Trust Automation, we also provide custom configurations, optimizing system performance for customer-specific applications. Trust recommends testing drives in their default setting before making custom requests. 95% of our customers use the default settings, however, current loop bandwidths greater the 5 khz can be achieved by matching to a specific motor. Current loop bandwidth needs to be compared equally between technologies. This is important both at low speeds and high speeds. Class C drives perform well between 1 and 2 khz. Above 2 khz, the Dead Band begins to distort the small and large signal current waveforms, compromising motion and system performance. Class D AC servo drives have limitations with both small signal response and high performance. The small signal performance of AC servo drives is limited due to the resolution limit of the control IC PWM generator. Class D AC servo drives typically use 8- to 10-bit resolution for their current control, totaling 256 to 2,048 discreet current steps between full reverse and full forward motor control. This is caused by the need to keep switching frequencies as high as possible usually 20 khz or higher. The resolution and switching frequency of a Class D drive is easy to calculate. Simply divide the control IC base frequency (typically 20 to 50 MHz) by the switching frequency. 50,000,000 / 20,000 = 2,500 possible steps between full reverse and full forward The ratio stays locked no matter what. To increase the PWM frequency, you must decrease your possible steps. To decrease the PWM frequency, you must increase your possible steps. 50,000,000 / 40,000 = 1,250 possible steps between full reverse and full forward Because available steps are limited, small signal performance is limited. However, highperformance staging applications require very good small signal performance. Another factor related to resolution and contributing to the small signal performance is line voltage. Most AC digital drives are connected directly to either 100 or 200 VAC. This means that the actual DC voltage switching inside the drive is usually 144 to 288 VDC. The current is the voltage driven through the resistance of the motor windings. Take, for example, a 200 VACconnected drive with 1,250 steps of resolution, assuming the motor has a 1 Ω coil. 288VDC / 1,250 steps = 0.23 volts per step in a perfect setup 0.23VDC / 1Ω = 0.23 Amps per step Many applications require less then 1 A to maintain steady state servo loop positioning. In this case, there are only five steps of control to maintain this positioning, resulting in stage dithering or buzzing due to the low resolution.

Most Class D AC servo drives have a true current limit bandwidth of less then 500 Hz. Most are actually closer to 200 Hz. Smooth motion, good stability and fast settling time requires accurate current loop bandwidth. It is possible to achieve approximately 85% accuracy of a waveform with eleven data points per waveform. The following diagram illustrates this principle: CURRENT LOOP ACCURACY VS. EFFICIENCY AC Digital Drive Waveform Reproduction: 2 Steps 20% Efficient (Nyquist Theory) AC Digital Drive Waveform Reproduction: 11 Steps 85% Efficient Linear Drive Waveform Reproduction: Infinite Steps 99% Efficient To accurately reproduce a waveform you need to have a minimum of eleven data points, meaning the current loop sampling needs to be eleven times the actual waveform frequency. This is why most AC digital drives have 200 to 500 Hz true bandwidth. 500 Hz * 11 data points = 5,500 Hz current loop. Very often, digital drive manufacturers specify current loop bandwidth using the Nyquist Theory, which states you only need 2 data points to represent a waveform. This is true if the waveform accuracy you are trying to represent is not important. The current loop technology differs greatly between Class AB linear drives and Class D AC digital drives. A Class AB linear drive current loop is entirely analog and for good reason. An analog current loop provides two important characteristics: 1. An infinite number of steps between full reverse and full forward. 2. A very fast current loop because it is not limited by the processor speed. These attributes are advantages in high precision stage applications for several reasons: 1. The small and large signal resolutions and responses are very good. 2. Waveform reproduction is extremely accurate. 3. Input voltage does not affect system stability. All these items result in increased stability and faster settling times.

HIGH EFFICIENCY The performance improvements seen with a Class AB linear drives come at the expense of efficiency. The Class AB drive stage needs to maintain small amounts of power inside the drive circuits, resulting in increased heat. Also, due to the nature of a Class AB drive stage, excess voltage not needed by the motor is dissipated as heat. As a result, linear drives usually integrate large heat sinks to keep the drive components at a reasonable and specified operating temperature. SUMMARY The factors discussed in this paper will help you determine if linear or PWM drive technology is better suited for your application. Trust Automation is the leader in high-precision staging drives because of the attention given to the accuracy of signal reproduction, Zero Dead Band and high-quality analog design using precision-matched parts and high-performance components. These factors will help linear drive users achieve high precision with fewer concerns and problems typically associated with high-precision staging systems. TRUST AUTOMATION WWW.TRUSTAUTOMATION.COM 805-544-0761 143 SUBURBAN ROAD, SAN LUIS OBISPO, CA 93401