MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Similar documents
MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

NH Plastic Bases. NH Plastic Bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Fuse Links NV/NH gg with Striker Pin Dimensions

3 - Protection components Circuit-breakers

Technical features table for miniature circuit-breakers SH 200 Series

400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka

ALPHA DIN Wall-Mounted. Distribution Boards

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Safety switches with slotted hole lever

Output of three-phase motors at 50 Hz and 400 V

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

(1,5 modules per pole)

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Type CP-S, CP-C & CP-A Switch mode

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Installation / Monitoring Technique

FM series position switches

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Accessories. Accessories

Modular Devices and Enclosures

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Thermistor motor protection relays

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Page 13-2 Page Page 13-7

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Moeller Electric Corporation

Description Basic devices with positive operation contacts

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

LR Position Switches TECHNICAL DATASHEET

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

E-STOP relays, safety gate monitors

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

Three-phase monitoring relays

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Type: DILM40(RDC24) Article No.:

For non-electrical quantities

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Controls Contactors and Contactor Assemblies Special Applications

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Low voltage switchgear

7P Series - Surge Protection Device (SPD) Features 7P P P

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Han High Temp. Description. Design overview. Han High Temp connectors remain robust and reliable for their entire lifespan!

DIK 1,5 General data Technical data General

Three-phase monitoring relay CM-PVE

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDD.22

No-wear isolation of potentials in terminal block design

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

Datasheet - PROTECT-IE-02

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Electronic timer CT-TGD.22

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Contactors and Contactor Assemblies

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Control module CP-A CM

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Transcription:

MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom fitting/panel installation and are available in single pole, double pole and quadruple pole units. For installation of MULTIBLOC NH fuse switch disconnectors in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC size 00 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00, 160A. MULTIBLOC offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC Voltage DC 220 VDC Amper (A) 160 A Size per Standard 00 Ue = AC 400 V; Ie = 160 A SCCR Ue = AC 500 V; Ie = 160 A Ue = AC 690 V; Ie = 125 A Mounting bottom fitting/panel Switchability 1-,2-,4-pole switching Number of Poles 1,2,4 80kA 80kA 50kA FEATURES & BENEFITS Touch protection IP 20 - when fuse link is in test mode IP rating is maintained Parking position of switch operating cover even with fuse-links inserted Modular system of cover - cover for cable termination area can be extended - optional Varieties of cable termination: screw, clamp strap, Al-Cu clamp, extendable for V-terminal - optional Padlocking and sealing of switch door cover - optional Indicating switch for switch door position - optional Safe on load connection/disconnection in accordance with IEC 60947-3 APPLICATIONS House incoming units Meter distribution units Measuring transformer cabinets Transmitting stations for telecommunications STANDARDS IEC/EN 60 947-3 For NH-fuse links size 000/00 in accordance with IEC/EN 60 269-2, VDE 0636-2 EP.MERSEN.COM 1

PRODUCT RANGE MULTIBLOC 00.ST8 size 00 160A, 690VAC bottom fitting, single pole Item Poles Cable termination components Design Package Weight 1.000.053 1.000.053 F229292 1 2 M8 terminal screws - 1 piece 0.32 kg 1.000.054 E1022998 1 2 clamp straps Cu 4 70 mm² - 1 piece 0.32 kg 1.000.114 F1022999 1 2 Al/Cu clamps 1,5 70 mm²round stranded, 95 mm² sectoral solid - 1 piece 0.35 kg 1.001.817 G1023000 1 2 M8 terminal screws for direct installation on to bus bars with M8 screw 1 piece 0.29 kg 1.001.817 MULTIBLOC 00.ST8 size 00 160A, 690VAC bottom fitting, double pole Item Poles Cable termination components Design Package Weight 1.000.139 1.000.139 G229293 2 3 M8 terminal screws 2 poles 1 piece 0.62 kg 1.004.453 E1062213 2 3 M8 terminal screws with ready fitted special solid link as neutral conductor in pole 2 for leading 1 piece 0.62 kg and lagging switching (right side) 1.000.140 H1023001 2 4 clamp straps Cu 4 70 mm² 2 poles 1 piece 0.62 kg 1.000.141 1.002.377 MULTIBLOC 00.ST8 size 00 160A, 690VAC bottom fitting, quadruple pole Item Poles Cable termination components Design Package Weight 1.000.141 J1023002 4 8 M8 terminal screws pole 4 right side 1 piece 1.04 kg 1.000.142 K1023003 4 8 clamp straps Cu 4 70 mm² pole 4 right side 1 piece 1.04 kg 1.001.575 L1023004 4 8 M8 terminal screws pole 4 left side 1 piece 1.04 kg 1.002.377 T1002127 4 8 M8 terminal screws with ready fitted special solid link as neutral conductor in pole 4 for 1 piece 1.8 kg leading and lagging switching 1.003.141 N1023006 4 8 clamp straps Cu 4-70 mm² with ready fitted special solid link as neutral conductor in pole 4 for leading and lagging switching 1 piece 1.8 kg EP.MERSEN.COM 2

TECHNICAL DATA IN ACCORDANCE WITH EN / IEC 60947 00.ST8 single pole 00.ST8 double pole Number of poles/phases 1 2 4 Size 00 00 00 Conventional free air thermal current with NH-fuse links I th 160 A 160 A 160 A Max. power dissipation of fuse links P n 12 W 12 W 12 W Conventional free air thermal current with solid links I th 200 A 200 A 200 A Max. power dissipation of solid links P n 1,2 W 1,2 W 1,2 W Utilization category to IEC/EN 60947-3 U e = AC 400 V; I e = 160 A U e = AC 500 V; I e = 160 A U e = AC 690 V; I e = 125 A U e = DC 220 V; I e = 160 A AC 23 B AC 22 B AC 21 B DC 22 B AC 23 B AC 22 B AC 21 B - 00.ST8 quadruple pole AC 23 B AC 22 B AC 21 B - Rated operational voltage U e 690 V 690 V 690 V Rated insulation voltage U i 1000 V 1000 V 1000 V Rated impulse withstand voltage U imp 8 kv 8 kv 8 kv Rated frequency 50... 60 Hz 50... 60 Hz 50... 60 Hz Degree of protection IP 20 IP 20 IP 20 Degree of pollution 3 3 3 Rated duty uninterrupted duty uninterrupted duty uninterrupted duty Rated conditional short-circuit current with fuse links U e = AC 400 V; I e = 160 A U e = AC 500 V; I e = 160 A U e = AC 690 V; I e = 125 A Rated short circuit making capacity with solid links I cm 6.2 kasw 6.2 kasw 6.2 kasw Rated short-time withstand current I cw 4 ka / 1 s 4 ka / 1 s 4 ka / 1 s Power dissipation by I th without NH-fuse links 4 W 8 W 11 W Power dissipation by I th 200A without solid links 6,3 W 12,5 W 17 W Installation mode bottom fitting bottom fitting bottom fitting 50 ka 50 ka 50 ka Cable terminal connection Standard cable terminal M8 M8 M8 for cable lugs Cu max. 2 x 70 mm² 2 x 70 mm² 2 x 70 mm² for cable lugs Al max. 2 x 70 mm² 2 x 70 mm² 2 x 70 mm² for copper bars with max. dimensions 20 x 5 mm 20 x 5 mm 20 x 5 mm EP.MERSEN.COM 3

DIMENSIONS MULTIBLOC 00.ST8 NH-fuse switch disconnector single pole (M 01115) max. thickness of switchboard 4 mm neutral conductor support The neutral conductor art. no. 00SZNS (accessory) can be fixed on right side, left side or both sides of switch. dimensions of switch board cut out for bottom fixing without cover shield switch board dimensions for bottom fitting Dimensions in mm EP.MERSEN.COM 4

DIMENSIONS MULTIBLOC 00.ST8 NH-fuse switch disconnector double pole (M 01124) max. thickness of switchboard 4 mm dimensions of switch board cut out for bottom fixing without cover shield dimensions for bottom fitting switch board Dimensions in mm EP.MERSEN.COM 5

DIMENSIONS MULTIBLOC 00.ST8 NH-fuse switch disconnector quadruple pole (M 01120) max. thickness of switchboard 4 mm neutral conductor support The neutral conductor art. no. 00SZNS (accessory) can be fixed on right side, left side or both sides of switch. dimensions of switch board cut out for bottom fixing without cover shield switch board dimensions for bottom fitting Dimensions in mm EP.MERSEN.COM 6

DIMENSIONS Cable termination size 00 (MA 120c) type N S A R terminal screw clamp srap Al/Cu clamp frame clamp Cu 16-70 Cu 4-70 Cu 1,5-70 Cu 2,5-70 cross section Al 1,5-70 sectoral stranded 2 mm Al 16-95 Al --- Al 1,5-95 sectoral solid Al --- M(an) (Nm) 10 3-4 3-4 6 M5 M8 M5 2 4-70/95mm se rm, re max. 20 sm, se rm, re rm, re min. 25 max. 9x 9mm x 0,8mm 4-70mm 2 rm, re 21 1,5-2,5mm 2 assembled by the manufacturer Dimensions in mm EP.MERSEN.COM 7

EXPLODED SKETCH MULTIBLOC 00.ST8 NH- fuse switch disconnector single pole (E 1.000.622) 6 7 8 1 9 5 1 4 11 10 3 2 no. article short Description 1 1.000.149 Cover for cable termination, single pole 2 1.000.151 Set for mounting on DIN rails 125mm 3 1.000.152 Set for mounting on DIN rails 150mm 4 MZ00HD Indicating switch f.switch door position 5 1.000.150 Locking device f. windows,1 Set=3 pieces 6 1.000.155 Cover sealing device, installation set 7 00SZS M8 terminal screw screw,1 Set = 3 pieces 8 00SZESK Clamp strap 4-70mm², set = 3 pieces 9 00SZA70 Al/Cu clamp 1 5-70mm², set = 3 pieces 10 1.003.571 Al/Cu clamp 50-95 mm², set = 3 pieces 11 00SZNS Neutral cond. support with clamp strap EP.MERSEN.COM 8

ACCESSORIES Cover shields Item Design Package Weight 1.002.764 T1022965 cover shield for installation in distribution units size (width x height): 220 x 240 mm for one 00.ST8 quadruple pole 1 piece 93 g 1.002.764 Cover/shrouds for cable termination Item Design Package Weight 1.000.149 1.000.149 V229282 1.000.148 W229283 cover for cable terminal connection for 00.ST8 single pole, 1 set = 2 pieces cover for cable terminal connection for 00.ST9 triple pole, 1 set = 2 pieces 1 set 21 g 1 set 43 g 1.000.148 MZ00HD 1.000.155 1.000.151 1.000.152 Installation devices 1.000.151 B229288 1.000.152 C229289 Indication facilities MZ00HD Locking and sealing devices/cover sealing device 1.000.155 L229297 Item Design Package Weight adapter for installation between DIN-rails in accordance with EN 60715, DIN-rail distance 125mm for 00.ST8 single pole adapter for installation between DIN-rails in accordance with EN 60715, DIN-rail distance 150mm for 00.ST8 single pole Item Design Package Weight cover sealing device-installation set for 00.ST8 1-, 2-, 4-pole and 1.ST8/RST8 1 piece 80 g 1 piece 0.14 kg Item Design Package Weight V1022989 indicator for switch door position micro switch 1 a contact/ 1 b contact, 5 A, 250 V for MULTIBLOC 00.ST8 1-, 2-, 4-pole 1 piece 90 g 1 piece 10 g EP.MERSEN.COM 9

ACCESSORIES Locking and sealing devices/locking device for window Item Design Package Weight 1.000.150 K229296 locking device for window for 00.ST8 1-, 2-, 4-pole and 1./2.ST8/RST8 1 set 20 g 1.000.150 Varieties of cable termination Item Design Package Weight 00SZS 00SZESK 00SZA70 1.003.571 1.003.433 00SZSV6 00SZNS 00SZS 00SZESK 00SZA70 M229298 E214594 R211523 1.003.571 V1033684 1.003.433 L1022958 00SZSV6 K1022957 Neutral conductor 00SZNS M8 terminal screw for switch gear size 00 clamp strap Cu 4 70 mm² for switch gear size 00 Al/Cu clamp 1,5 70 mm² for switch gear size 00 Al/Cu clamp 50-95 mm² round stranded for switch gear size 00 triple clamp per pole 1.5 up to 16 mm² V-shaped lug size 00, M8, for V-terminal clamp size 00 for switch gear size 00 with screw terminal supplementary set for V-terminal with V-terminal clamps 1 set 35 g 1 set 35 g 1 set 75 g 1 set 88 g 1 set 0.14 kg 1 set 0.13 kg Item Design Package Weight A1023086 neutral conductor support for lateral installation either left or right side of MULTIBLOC size 00 cable termination clamp strap Cu 4-70 mm² round stranded/round solid 1 piece 83 g EP.MERSEN.COM 10