Temperature Input Module for Zone 1 Series 9482/32

Similar documents
Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Vibration Transducer Supply Unit Series

Binary Output Series 9175

Isolators A3/1.

Binary Output without Power Supply Series 9176

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolating Repeater Input Series 9163

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Fieldbus Isolating Repeater Series 9185/11

Remote I/O. 74 Remote I/O. Remote I/O System

Two-channel safety barriers Series 9002

Digital I/O Coupler (4-wire) Series 9413/21

Single-Channel Safety Barriers Series 9001

Two-channel safety barriers Series 9002

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Rail mounted Temperature Transmitter TH102/TH102-Ex

Assembly. Front view. Parametrization interface. Power Bus

Temperature transmitter itemp PCP DIN rail TMT 121

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

itemp HART DIN rail TMT112

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Technical Information RMA42

Inductive sensor slot-type SI2-K08-AP7

RMA42. Technical Information

Temperature head transmitter itemp PCP TMT 181

itemp PA TMT184 Technical information

PRetrans Table of contents

Temperature Measurement

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

SITRANS T measuring instruments for temperature

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Universal Intelligent 2-wire DIN Rail Transmitters

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

HART field temperature transmitter Models TIF50, TIF52, TIF62

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Safety Instructions Nivotester FTC625, FTC325

TTH200 Head-mount temperature transmitter

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

SINEAX TI 807 Passive DC signal isolator

onlinecomponents.com

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Temperature Transmitter itemp RTD DIN rail TMT 127

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Technical Data. General specifications. Rated operating distance s n 3 mm

Rosemount 148 Temperature Transmitter

Universal Intelligent 2-wire DIN Rail Transmitters

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SINEAX V 604s Programmable multifunctional transmitter

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter

Power supply. Calibration. Surface finishing. Seal. Process connection

Product Manual 5202 Pulse isolator

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Transcription:

www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits > For thermocouples according to IEC, DIN and GOST with internal or external reference > For resistance transmitter, mv sensors and joystick application > Line fault monitoring and LED indication per channel > Diagnostics based on NE107 > Module can be replaced in hazardous area under voltage (hot swap) 15234E00 The temperature input module is used for connecting of up 8 intrinsically safe temperature sensors to the remote I/O system IS1+. Each channel can be used as input for resistance temperature detectors and resistance transmitters in 2, 3 or 4 wire technology or as earthed/insulated thermocouples and mv sensors. In the operating mode "4 channel fast", very short signal delays are achieved, which allow special applications, such as joystick applications. Compensation of the reference temperature is performed internally for thermocouples or via an external reference. Compatible spare for IS1 remote I/O modules: Series 9480/12 and 9481/12 ATEX / IECEx Zone 0 1 2 20 21 22 Ex interface x x x x x x Installation in x x x x WebCode 9482A Remote I/O /1

Explosion Protection Global (IECEx) Gas and dust IECEx DEK 13.0046X Ex ia [ia Ga] IIC T4 Gb [Ex ia Da] IIIC Europe (ATEX) Gas and dust Certifications and certificates Certificates Further parameters Installation Further information Safety data Combination of connections 1 Sensors Installation type Max. output voltage U o ext Max. current I o Max. power P o Max. connectable inductance L o / Capacitance C o IIC IIB / IIIC combination of connections 2 Sensors Installation type Reference Thermocouple / mv sensor Max. output voltage U o ext Max. current I o Max. power P o Max. connectable inductance L o / Capacitance C o IIC DEKRA 13 ATEX 0140 X E II 2 (1) G Ex ia [ia Ga] IIC T4 Gb E II (1) D [Ex ia Da] IIIC IECEx, ATEX, Canada (cfm), USA (FM), Belarus (operating license) in Zone 1, Zone 2, Zone 21, Zone 22 and in the safe area see respective certificate and operating instructions For proof of intrinsic safety, the safety data listed below must be used in accordance with the combination of connections and the corresponding sensor. For further information and combination, see operating instructions. up to 8 resistance temperature detectors or resistance transmitters no thermocouple / mv sensor connected insulated 6.24 V 2-wire 3-wire 4-wire 6.5 ma 7.8 ma 9.8 ma 2-wire 3-wire 4-wire 10.5 mw 12.5 mw 15.7 mw L o [mh] 100 50 20 2 0.2 0.02 0.002 C o [μf] 1.1 1.2 1.4 2.0 3.2 7.0 25 L o [mh] 100 50 20 2 0.2 0.02 0.002 C o [μf] 5.8 6.3 7.1 10 19 51 570 up to 8 thermocouples or mv sensors can be connected simultaneously to resistance temperature detector and resistance transmitter and/or external reference. earthed internal/external 12.92 V 25.0 ma 81.0 mw L o [mh] 72 50 10 2 1 0.5 0.2 C o [μf] 0.17 0.22 0.34 0.46 0.53 0.62 0.78 IIB / IIIC L o [mh] 100 20 5 1 0.5 0.2 0.1 C o [μf] 1.2 1.6 2.1 3.0 3.5 4.5 5.7 Resistance sensor see value combination of connections 3 ext. reference see values combination of connections 4 /2 Remote I/O

Explosion Protection combination of connections 3 Sensors up to 8 resistance temperature detectors / resistance transmitters and/or thermocouples / mv sensors simultaneously connected in any combination of sensor types possible Installation type Resistance temperature detector and resistance transmitter insulated / thermocouple and mv sensor earthed Reference internal/external Resistance sensor Max. output voltage 12.92 V U o ext Max. current I o 2-wire 13.1 ma 3-wire 15.7 ma 4-wire 19.6 ma Max. power P o 2-wire 42.2 mw 3-wire 50.6 mw 4-wire 63.3 mw Max. connectable inductance L o / Capacitance C o IIC L o [mh] C o [μf] 100 0.19 50 0.25 20 0.31 5 0.40 1 0.54 0.5 0.63 0.2 0.78 IIB / IIIC L o [mh] 100 20 10 2 1 0.5 0.1 C o [μf] 1.3 1.7 1.9 2.5 3.0 3.5 5.7 Thermocouple / see values combination of connections 2 mv sensor ext. reference see values combination of connections 4 combination of connections 4 Sensors External reference when connected to thermocouples / mv sensors, also simultaneously connectable to resistance temperature detectors / resistance transmitters Installation type insulated Reference external (3-wire) external reference Max. output voltage 12.92 V U o ext Max. current I o 17.4 ma Max. power P o 56.2 mw Max. connectable inductance L o / Capacitance C o IIC L o [mh] C o [μf] 66 0.17 50 0.21 20 0.29 5 0.39 1 0.53 0.5 0.62 0.2 0.78 IIB / IIIC L o [mh] 100 20 5 1 0.5 0.2 0.1 C o [μf] 1.2 1.6 2.1 2.9 3.5 4.5 5.7 Resistance sensor see value combination of connections 3 Thermocouple / see values combination of connections 2 mv sensor Max. internal capacity C i negligible Max. internal inductance L i negligible Selection Table Version Description Installation Order number Weight Temperature Input Module for Zone 1 8 channels with adjustable parameters for resistance temperature detectors, thermocouples; potentiometers with channel status LEDs Please order 2 terminals separately - see Accessories in Zone 1, Zone 2, Zone 21, Zone 22 and in the safe area kg 9482/32-08-11 0.275 Remote I/O /3

Technical Data Electrical data Ex i inputs Resistance temperature detector / resistance transmitter Number of channels 8 s 8 channel precise/ 4 channel fast (joystick) Connection type 2-, 3- and 4-wire circuits Resistance range 0 10 kω Measuring current < 200 μa multiplexed Max. line resistance 100 Ω per cable Measurement accuracy 0.025 % (8 channel precise) / ± 1 % (4 channel fast joystick) All values in % of measuring range at 23 C Ambient temperature 0.025 % / 10 K influence Linearity Temperature linear / resistance linear (adjustable parameters) connectable resistance temperature detectors / resistance transmitters Type Reference Measuring range (ITS-90) Medium resolution Pt100 IEC 60751-200... +850 C 0.1 K Pt500 IEC 60751-200... +850 C 0.1 K Pt1000 IEC 60751-200... +850 C 0.1 K Ni100 DIN 43760-60... +180 C 0.1 K Ni500 DIN 43760-60... +180 C 0.1 K Ni1000 DIN 43760-60... +180 C 0.1 K Pt46 2) GOST 6651-94 -200... +1100 C 0.15 K Pt50 2) GOST 6651-94 -200... +1100 C 0.15 K Pt100 1) GOST 6651-94 -200... +1100 C 0.1 K Cu53 2) GOST 6651-94 -50... +180 C 0.1 K M50 1) GOST 6651-94 -200... +200 C 0.15 K M100 1) GOST 6651-94 -200... +200 C 0.1 K 3-wire potentiometer - - 0... 500 Ω 0.02 Ω 3-wire potentiometer - - 0... 2,5 k Ω 0.10 Ω 3-wire potentiometer - - 0... 5 k Ω 0.20 Ω 3-wire potentiometer - - 0... 10 k Ω 0.4 Ω Joystick (4-wire) - - 500... 10 k Ω Reaction time Type Type of connection 4 channel fast 8 channel fast Activated Deactivated Activated Deactivated RTD 2-wire 400 ms 400 ms 750 ms 720 ms RTD 3-wire 400 ms 400 ms 750 ms 720 ms RTD 4-wire 400 ms 400 ms 750 ms 720 ms R 2-wire in R 400 ms 400 ms 750 ms 720 ms R 3-wire in % 90 ms 70 ms 750 ms 720 ms R 4-wire in R 400 ms 400 ms 750 ms 720 ms R 4-wire in % 90 ms 70 ms 750 ms 720 ms To achieve the times of "error control deactivated", the error control on all channels must be "OFF"! As soon as the error control is "ON" at one channel only, the times for "error control activated" are valid. /4 Remote I/O

Technical Data Electrical data Ex i inputs Thermocouples / mv sensors Number of channels 8 s 8 channel precise/4 channel fast Connection type 2-wire circuits Signal range -10 +100 mv Linearity Temperature linear / voltage linear (adjustable parameters) All values in % of the measuring range at 23 C connectable thermocouples / mv sensors Reaction time Type Reference Measuring range (ITS-90) Medium resolution B IEC 60584-1 +400... +1800 C 0.25 K 0.1 % E IEC 60584-1 -200... +1000 C 0.1 K 0.013 % J IEC 60584-1 -200... +1200 C 0.1 K 0.014 % K IEC 60584-1 -200... +1370 C 0.1 K 0.02 % N IEC 60584-1 -200... +1300 C 0.1 K 0.02 % R IEC 60584-1 -50... +1767 C 0.2 K 0.05 % S IEC 60584-1 -50... +1767 C 0.2 K 0.053 % T IEC 60584-1 -200... +400 C 0.1 K 0.042 % L DIN 43710-200... +900 C 0.1 K 0.027 % U DIN 43710-200... +600 C 0.1 K 0.038 % XK GOST 8.585-50... +800 C 0.1 K 0.02 % mv - - 0... +100 mv 3.6 μv 0.01 % Type Type of connection 4 channel fast Medium measurement deviation with regard to measuring range 8 channel fast Activated Deactivated Activated Deactivated Thermocouple 2-wire 500 ms 450 ms 800 ms 750 ms 0... 100 mv 2-wire 500 ms 450 ms 800 ms 750 ms To achieve the times of "error control deactivated", the error control on all channels must be "OFF"! As soon as the error control is "ON" at one channel only, the times for "error control activated" are valid. Input resistance 10 MΩ Ambient temperature 0.025 % / 10 K influence Reference compensation Number of channels 1 (clamping unit see operating instructions) s internal (adjustable parameters) / external 3-wire circuit Connection type 3-wire circuit (external) Measuring range -40 +80 C Measurement accuracy internal: 0.025% / external: depending on sensor type, see "Connectable resistance temperature detectors" resolution 0.1 K Temperature deviation ± 2 K for thermocouples with internal compensation Galvanic separation Test voltage acc. to standard EN 60079-11 Between auxiliary power/ ) 1500 V AC system components Between two I/O modules ) 500 Between I/O channels/ ) 500 V AC system components Between I/O channels/ ) 500 V AC ground (PA) Remote I/O /5

Technical Data Electrical data Electromagnetic compatibility Tested to the following standards and regulations: EN 61326-1 (2006) IEC 61000-4-1 6, NAMUR NE 21 Measurement accuracy 0.1 % (8 channel precise) Electrical connection Power supply BusRail Types 9494 Ex i field signals Pluggable, blue terminals, 16-pole, 2.5 mm 2, screw- or spring-type versions with lock Auxiliary power Maximum power 1 W consumption Maximum power dissipation 1 W Device-specific data Settings Module Diagnostics message ON / OFF 8 channel precise / 4 channel fast Selection reference internal / external 3-wire Type external reference PT100, PT1000, PT100 GOST Signal Behaviour in case of error hold last value ON / OFF Sensor type see table (connectable sensors) Type of connection 2-, 3-, 4-wire Ambient conditions Ambient temperature -40 +75 C (observe operating instructions) Storage temperature -40 +80 C Maximum relative humidity 95 % (without condensation) Maximum operating altitude < 2000 m Semi-sinusoidal shock 15 g (3 shocks per axis and direction) (IEC EN 60068-2-27) Sinusoidal vibration 1 g in the frequency range 10... 500 Hz (IEC EN 60068-2-6) 2 g in the frequency range 45... 100 Hz Mechanical data Degree of protection IP20 (IEC 60529) Module enclosure polyamide 6GF Fire resistance (UL 94) V2 Pollutant class corresponds to G3 Dimensions L = 128 mm, B = 96.5 mm, H = 67 mm Indication LED indication Module requires LED "M/S", blue maintenance Operating state LED "RUN", green Group error LED "ERR", red Channel error LED red for each channel Function indication Retrievable parameters Manufacturer, Type, hardware revision, software revision, serial number Error indication Module status and alarms Internal bus error primer / redundant No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance Signal errors for each channel Signal status bit "0" = signal disturbed; "1" = signal valid Wire breakage input Resistance temperature detector / resistance transmitter: > 100 Ω; thermocouples / mv-sensors: > 1000 Ω Short circuit input Resistance temperature detector / resistance transmitter: < 15 Ω Measuring range Exceeding / shortfall /6 Remote I/O

Technical Data Mounting / Installation Mounting orientation horizontal or vertical (observe operating instructions) Mounting type on 35 mm DIN rail NS 35/15 (DIN EN 60715) Dimensional drawings (all dimensions in mm / inches) - subject to modifications 68 [2,68] 64 [2,52] 70 [2,76] 128,5 [5,06] 98 [3,86] 96,5 [3,8] 16309E00 Remote I/O /7

Accessories and Spare Parts Designation Figure Description Art. no. Pluggable terminal 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the 162702 field signals to I/O modules, for intrinsically safe field circuits Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module 02079E00 Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the 162718 field signals to I/O modules, for intrinsically safe field circuits Labelling: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, 162695 for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module 02077E00 Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, 162716 blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 17... 32 Reference Serves for measurement of the temperature with 160673 Pt 100 in 3-wire circuit. ext. reference in terminal block Labelling strips "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 DIN sheet 05869E00 For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 Partition 09900E00 For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance 220101 Warning sign 15196E00 "Clean modules only with a damp cloth." 162796 05872E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /8 Remote I/O