Product Manual wire HART transmitter

Similar documents
Product Manual wire HART transmitter

Product manual wire programmable RTD transmitter

Product Manual 5202 Pulse isolator

Product Manual 3186A: 2-wire transmitter isolator 3186B: 2-wire current isolator

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Product manual 3000 series 6 mm series of temperature converters

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Product manual wire HART 7 temperature transmitter

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

CERTIFICATE OF COMPLIANCE

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

PRetrans Table of contents

2-wire HART Transmitter. No. 6337V102-UK From ser. no

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

2-Wire HART Transmitter. No. 6335V110-UK From ser. no

2-wire HART Transmitter. No. 6337V100-UK From ser. no SIGNALS THE BEST

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Universal Intelligent 2-wire DIN Rail Transmitters

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Isolators & converters

Temperature Input Module for Zone 1 Series 9482/32

Analog Universal Module HART for Zone 2 Series 9468/33

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

Intrinsic Safety Control Drawing

Temperature Measurement

R88000 T (including ATEX)

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Universal Intelligent 2-wire In-head Transmitters

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

IP26 Series Current to Pneumatic Converter

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Universal Intelligent 2-wire DIN Rail Transmitters

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Digital Input Output Module for Zone 2 Series 9470/33

Product Guide. universal. isolation. i.s. interface. temperature. display

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Power supply. Calibration. Surface finishing. Seal. Process connection

IPAQ C520 / C520X R520 / R520X. HANDBOOK / User Manual

D5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

MODEL: R30US4. Remote I/O R30 Series

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

5000 series Signal Isolation

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature Measurement Transmitters for mounting in sensor head

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

HART Compatible Intelligent 2-wire In-head Transmitters

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

Resistance thermometer Model TR30, compact design

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Isolators A3/1.

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

Technical Information RMA42

OPTITEMP TT 10 C/R Technical Datasheet

Isolators A3/1.

The Rosemount 848T Wireless Temperature Transmitter

Temperature Measurement Transmitters for mounting in sensor head

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

0 2 1 â Ó. itemp HART TMT182. Technical Information

General Specifications

Loop Powered Indicator

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

RMA42. Technical Information

Rosemount 148 Temperature Transmitter

Certificate of Compliance

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Field indicator for current loops with HART communication Models DIH50, DIH52

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Temperature Measurement

Isolating Repeater Input Series 9163

Temperature transmitter itemp PCP DIN rail TMT 121

Digital Input Output Module for Zone 2 Series 9470/33

SITRANS T measuring instruments for temperature

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

DPharp Differential Pressure and Pressure Transmitters

Inductive sensor slot-type SI2-K08-AP7

1-830 SERIES DISPLACEMENT TRANSMITTER

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

itemp HART DIN rail TMT112

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Single-Channel Safety Barriers Series 9001

Transcription:

Product Manual 6337 2wire HART transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 6337V103UK From serial no.: 150950564

6 Product Pillars to meet your every need Individually outstanding, unrivalled in combination With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial and factory automation. All our products comply with or surpass the highest industry standards, ensuring reliability in even the harshest of environments and have a 5year warranty for greater peace of mind. Our range of temperature transmitters and sensors provides the highest level of signal integrity from the measurement point to your control system. You can convert industrial process temperature signals to analog, bus or digital communications using a highly reliable pointtopoint solution with a fast response time, automatic selfcalibration, sensor error detection, low drift, and top EMC performance in any environment. We deliver the safest signals by validating our products against the toughest safety standards. Through our commitment to innovation, we have made pioneering achievements in developing I.S. interfaces with SIL 2 Full Assessment that are both efficient and costeffective. Our comprehensive range of analog and digital intrinsically safe isolation barriers offers multifunctional inputs and outputs, making PR an easytoimplement site standard. Our backplanes further simplify large installations and provide seamless integration to standard DCS systems. We provide inexpensive, easytouse, futureready communication interfaces that can access your PR installed base of products. The detachable 4501 Local Operator Interface (LOI) allows for local monitoring of process values, device configuration, error detection and signal simulation. The next generation, our 4511 Remote Operator Interface (ROI) does all that and more, adding remote digital communications via Modbus/RTU, while the analog output signals are still available for redundancy. With the 4511 you can further expand connectivity with a PR gateway, which connects via industrial Ethernet, wirelessly through a WiFi router or directly with the devices using our Portable Plant Supervisor (PPS) application. The PPS app is available for ios, Android and Windows. Our unique range of single devices covering multiple applications is easily deployable as your site standard. Having one variant that applies to a broad range of applications can reduce your installation time and training, and greatly simplify spare parts management at your facilities. Our devices are designed for longterm signal accuracy, low power consumption, immunity to electrical noise and simple programming. Our compact, fast, highquality 6 mm isolators are based on microprocessor technology to provide exceptional performance and EMCimmunity for dedicated applications at a very low total cost of ownership. They can be stacked both vertically and horizontally with no air gap separation between units required. Our display range is characterized by its flexibility and stability. The devices meet nearly every demand for display readout of process signals, and have universal input and power supply capabilities. They provide a realtime measurement of your process value no matter the industry, and are engineered to provide a userfriendly and reliable relay of information, even in demanding environments.

2wire HART transmitter 6337 Table of contents Technical characteristics... 4 Mounting / installation... 4 Applications... 4 Order... 5 Electrical specifications... 5 Accessories... 5 Changing the HART protocol version... 8 Changing the HART protocol version using the PReset software and 5909 Loop Link or HART communication interface... 8 Connections... 11 Block diagram... 12 Programming... 12 Connection of transmitters in multidrop mode... 14 ATEX Installation Drawing 6337A... 15 ATEX Installation Drawing 6337D... 17 IECEx Installation Drawing 6337A... 19 IECEx Installation Drawing 6337D... 21 CSA Installation Drawing 6337D... 23 FM Installation Drawing 6337D... 25 Document history... 27 6337V103UK 3

2 1 2 2 1 1 2wire HART transmitter 6337 RTD, TC, Ohm, or mv input 2 analog inputs and 5 device variables with status available HART protocol revision selectable from HART 5 or HART 7 Hardware assessed for use in SIL applications Mounting on a DIN rail in safe area or hazardous gas and dust area Application Linearised temperature measurement with TC and RTD sensors e.g Pt100 and Ni100. HART communication and 4...20 ma analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors. Amplification of bipolar mv signals to standard 4...20 ma current signals. Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup. RTD to 4...20 ma TC to 4...20 ma Applications 2wire installation in control room V ma 2wire installation in control room V Technical characteristics HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol. The HART 7 protocol offers: Long Tag numbers of up to 32 characters. Enhanced Burst Mode and Event notification with time stamping. Device variable and status mapping to any dynamic variable PV, SV, TV or QV. Process signal trend measurement with logs and summary data. Automatic event notification with time stamps. Command aggregation for higher communication efficiency. 6337 is designed according to strict safety requirements and is therefore suitable for applications in SIL installations. Continuous check of vital stored data. Meeting the NAMUR NE 21 recommendations, the 6337 HART transmitter ensures top measurement performance in harsh EMC environments. Additionally, the 6337 meets NAMUR NE43 and NE89 recommendations. Resistance to 4...20 ma mv to 4...20 ma Difference or average RTD, TC or mv ma 2wire installation in control room V ma 2wire installation in control room V ma 2wire installation in control room V ma Mounting / installation DIN rail mounting with up to 84 channels per metre. Configuration via standard HART communication interfaces or by PR 5909 Loop Link. The 6337D can be mounted in zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/ III, Division 1, Groups A, B, C, D. 4 6337V103UK

Order Type Version Galvanic isolation Channels 6337 Standard ATEX, CSA, FM & IECEx : A : D 1500 VAC : 2 Single Double : A : B Accessories 5909 = Loop Link USB interface and PReset Software 5910 / 5910Ex = CJC connector for channel 1 5913 / 5913Ex = CJC connector for channel 2 Electrical specifications Environmental conditions: Specification range.................................. 40 C to 85 C Storage temperature................................. 40 C to 85 C Calibration temperature................................ 20...28 Humidity......................................... < 95% RH (noncond.) Protection degree.................................. IP20 Mechanical specifications: Dimensions (H x W x D)............................... 109 x 23.5 x 104 mm Weight (1 / 2 channels)............................... 150 / 200 g DIN rail type....................................... DIN EN/IEC 60715 35 mm Wire size......................................... 0.13...2.08 mm 2 / AWG 26...14 stranded wire Screw terminal torque................................. 0.5 Nm Common specifications: Supply voltage, DC Standard........................................ 8.0...35 V ATEX, CSA, FM & IECEx.............................. 8.0...30 VDC Internal consumption................................ 0.19...0.8 W Voltage drop...................................... 8.0 VDC Isolation voltage, test / operation.......................... 1.5 kvac / 50 VAC Warmup time...................................... 30 s Communications interface............................. Loop Link & HART Signal / noise ratio................................... > 60 db Response time (programmable).......................... 1...60 s EEprom error check.................................. < 10 s Signal dynamics, input................................ 22 bit Signal dynamics, output............................... 16 bit Effect of supply voltage variation.......................... < 0.005% of span / VDC 6337V103UK 5

Accuracy, the greater of general and basic values: General values Input type Absolute accuracy Temperature coefficient All ±0.05% of span ±0.005% of span / C Basic values Input type Basic accuracy Temperature coefficient Pt50 Pt1000 ±0.1 C ±0.005 C/ C Ni50 Ni1000 ±0.2 C ±0.005 C/ C Lin. R ±0.1 Ω ±5 mw / C Volt ±10 μv ±0.5 μv / C TC type: E, J, K, L, N, T, U ±0.5 C ±0.025 C / C TC type: B 1, Lr, R, S, W3,W5 ±1 C ±0.1 C / C TC type:b 2 ±3 C ±0.3 C / C TC type:b 3 ±8 C ±0.8 C / C TC type:b 4 not specified not specified TC B 1 accuracy specification range........................ > 400 C TC B 2 accuracy specification range........................ > 160 C < 400 C TC B 3 accuracy specification range........................ > 85 C < 160 C TC B 4 accuracy specification range........................ < 85 C TC cold junction compensation............................ < ±1.0 C Max. offset on input signal.............................. 50% of selec. max. value EMC immunity influence......................... < ±0.1% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst.................... < ±1% of span Input specifications: RTD input types: RTD type Pt100 Ni100 Lin. R Min. value 200 C 60 C 0 Ω Max. value 850 C 250 C 7000 Ω Min. span 10 C 10 C 25 Ω Standard IEC 60751 DIN 43760 Pt50, Pt100, Pt200, Pt500, Pt1000, Ni50, Ni100, Ni120, Ni1000 Cable resistance per wire (max.)........................... 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy) Sensor current.................................... Nom. 0.2 ma 6 6337V103UK

TC input types: Type B E J K L Lr N R S T U W3 W5 Min. temperature 0 C 100 C 100 C 180 C 200 C 200 C 180 C 50 C 50 C 200 C 200 C 0 C 0 C Max. temperature 1820 C 1000 C 1200 C 1372 C 900 C 800 C 1300 C 1760 C 1760 C 400 C 600 C 2300 C 2300 C Cold junction compensation (CJC): Constant, internal or external via a Pt100 or Ni100 sensor mv input: Measurement range................................. 800...800 mv Min. span........................................ 2.5 mv Input resistance.................................... 10 MΩ Output specifications and HART: Signal range....................................... 4...20 ma Min. signal range.................................... 16 ma Updating time..................................... 440 ms Load resistance..................................... (V supply 8) / 0.023 [Ω] Sensor error detection, programmable...................... 3.5...23mA (shorted sensor error detection is ignored at TC and mv input) NAMUR NE43 Upscale................................ 23 ma NAMUR NE43 Downscale............................... 3.5 ma HART protocol revisions................................ HART 5 and HART 7 Of span = Of the presently selected range Min. span 100 C 50 C 50 C 50 C 50 C 50 C 50 C 100 C 100 C 50 C 50 C 100 C 100 C Standard IEC584 IEC584 IEC584 IEC584 DIN 43710 GOST 304484 IEC584 IEC584 IEC584 IEC584 DIN 43710 ASTM E98890 ASTM E98890 Approvals: EMC 2004/108/EC................................... EN 613261 EAC TRCU 020/2011................................. EN 613261 Ex / I.S.: ATEX 94/9/EC..................................... KEMA 09ATEX0148 X CSA............................................ 1125003 FM............................................ 2D5A7 IECEx........................................... IECEx KEM 10.0084 X EAC Ex TRCU 012/2011............................... RU CDK.GB08.V.00410 Functionel safety: Hardware assessed for use in SIL applications FMEDAreport www.prelectronics.com 6337V103UK 7

Changing the HART protocol version It is possible to change the unit s HART protocol revision by using the PReset software and a PR 5909 Loop Link interface or a HART interface. Other HART configuration tools like a Handheld HART Terminal may also be used. Procedure for using a HART handheld terminal to change the 6337 from HART 7 to HART 5 and vice versa: Change the 6337 from HART 7 to HART 5: Drive the 6337 device Online and enter Device setup Diag/Service. Select Write protection and Write protect by entering * * * * * * * * (8 stars). Select New password type * * * * * * * * (8 stars) & then HARTREV5. Select Write enable by entering CHANGE. Change the 6335 (6337) from HART 5 to HART 7: Drive the 6335 device Online and enter Device setup Diag/Service. Select Write protection and Write protect by entering * * * * * * * * (8 stars). Select New password type * * * * * * * * (8 stars) & then HARTREV7. Select Write enable and enter CHANGE. Please note this is only possible if the transmitter is marked 6337 on the label! Changing the HART protocol version using the PReset software and 5909 Loop Link or HART communication interface Switching from HART 7 to HART 5: Select the 6337 product, click the HART tab and open the folder Methods. Click Device Password / Write Protection / Protocol... and select Change protocol to HART 5 in the popup window, then acknowledge by pressing OK. 6337 (Device 6335): 8 6337V103UK

The following message will now appear: (6335) (6335). (6337) If you press Ja (Yes): 6335 Switching from HART 5 to HART 7: Please note this is only possible if the transmitter is marked 6337 on the label! From PReset, select the 6335 product, click the OPTIONS tab click Protect. Write protection must be set to ON. Select Change Password. Type in the New Password HARTREV7 and Reenter HARTREV7. Click OK. 6335 HARTREV7 6337V103UK 9

Switch Write protection OFF and writeenable the device by typing in the Password CHANGE in the top menu acknowledge by pressing OK. This action will reset the password to the default active password * * * * * * * * (8 stars) and restart the device in the updated HART 7 mode with write protection disabled. Now, select 6337 in PReset and reconfigure the device. 6335 CHANGE 10 6337V103UK

Connections Inputs: Channel 1 RTD, 2wire RTD, 3wire RTD, 4wire TC, internal CJC 41 42 43 44 41 42 43 44 41 42 43 44 41 42 CJC 44 Channel 2 Channel 1 Channel 2 RTD, 2wire RTD, 3wire RTD, 4wire 51 52 53 54 51 52 53 54 51 52 53 54 TC, external CJC 41 42 43 44 TC, external CJC 51 52 53 54 TC, internal CJC 51 52 CJC 54 Resistance, 2wire Resistance, 3wire Resistance, 4wire 41 42 43 44 41 42 43 44 41 42 43 44 Resistance, 2wire Resistance, 3wire Resistance, 4wire 51 52 53 54 51 52 53 54 51 52 53 54 Inputs: Channel 1 mv 41 42 43 44 RTD, difference or average 41 42 43 44 2 1 TC, difference or average, with internal CJC 41 42 CJC 44 2 1 TC, difference or average, with external CJC 41 42 43 44 2 1 Channel 2 mv 51 52 53 54 RTD, difference or average 51 52 53 54 2 1 TC, difference or average, with internal CJC 51 52 CJC 54 2 1 TC, difference or average, with external CJC 51 52 53 54 2 1 Channel 1 mv, difference or average 2wire installation HART comm. 41 42 43 44 11 12 13 14 11 12 13 14 2 1 Outputs: ma Channel 2 mv, difference or average 2wire installation HART comm. 51 52 53 54 21 22 23 24 21 22 23 24 2 1 ma 6337V103UK 11

21 51 41 42 43 4 4 Block diagram mv mv RTD, lin. R wire 4 3 2 TC * * Internal CJC connectors must be ordered separately. CH 1 44 43 M UX PGA A / D 42 41 C PU EEPRO M 4 ma Comm. D / A 0...16 ma 14 13 12 Supply HART comm. HART comm. Supply 6337 11 ma 4...20 ma 54 53 52 51 CH 2 6337 24 23 22 21 Programming 6337 can be configured in the following 3 ways: 1. With PR electronics A/S communications interface Loop Link and PReset PC configuration software. 2. With a HART modem and PReset PC configuration software. 3. With a HART communicator with PR electronics A/S DDL driver. 1: Loop Link For programming please refer to the drawing below and the help functions in PReset. When communicating with noninstalled devices, connectors 11, 12, 13, 14 (channel 1) and 21, 22, 23, 24 (channel 2) can be dismantled in the safe area to connect the terminals of the communications interface to the pins. Loop Link is not approved for communication with devices installed in hazardous (Ex) area. 11 12 13 14 14 (24) 11 (21) Black Red Disconnect * Yellow * Green Receiving equipment Vsupply Input 6337 Connector File Product Input Output Communication Language Option 08:30:00 PRetop 5331 Date: 2004810 Serial no: 043201594 Tag no: PRelectronics Analog input Analog output Input type: Pt100 DIN/IEC Output type: 4 20mA Input range: 0.00 50.00 C Sensor error: Upscale Connection: 3wire Cold junction comp: Response time: 1.00 sec Loop Link 5909 USB 5905 RS232 * Connected only for online programming 12 6337V103UK

21 5 1 42 43 4 4 41 2: HART modem For programming please refer to the drawing below and the help functions in PReset. 1 1 1 2 1 3 1 4 Receiving equipment 1 3 ( 2 3 ) Vsupply 1 2 ( 2 2 ) Input Rload > 250 Ω, < 1100 Ω 6337 HART modem F i l e P r o d u c t I n p u t O u t p u t C o m m u n i c a t i o n L a n g u a g e O p t i o n 0 8 : 3 0 : 0 0 P R e t o p 5331 D a t e : 1994 8 10 S e r i a l n o : 943201594 T a g n o : P R e l e c t r o n i c s A n a l o g i n p u t A n a l o g o u t p u t I n p u t t y p e : P t 100 D I N / I E C O u t p u t t y p e : 4 20 m A I n p u t r a n g e : 0. 00 50. 00 C S e n s o r e r r o r : U p s c a l e C o n n e c t i o n : 3 w i r e C o l d j u n c t i o n c o m p : R e s p o n s e t i m e : 1. 00 s e c 3: HART communicator For programming please refer to the drawing below. To get access to productspecific commands, the HART communicator must be loaded with the PR electronics A/S DDL driver. This can be ordered either at the HART Communication Foundation or PR electronics A/S. area Safe area Receiving equipment 21 1 1 1 2 1 3 1 4 1 3 ( 2 3 ) Vsupply 121 2 (22)( 22 ) Input Rload > 250 Ω, < 1100 Ω 51 42 43 44 41 6337 6337V103UK 13

Connection of transmitters in multidrop mode The HART communicator or a PC modem can be connected accross AB or BC. A Power supply 6335 6335 6335 R B Rload > 250 ohm, < 1100 ohm C Max. 15 channels The outputs of max. 63 transmitters can be conected in parallel for a digital HART communication on 2wires. Before it is connected, each transmitter must be configured with a unique number from 1 to 63. If 2 transmitters are configured with the same number, both will be excluded. The transmitters must be programmed for multidrop mode (with a fixed output signal of 4 ma). Maximum current in the loop is therefore 252 ma. The communication is either by means of a HART communicator or a HARTmodem. The PReset PC configuration software can configure the individual transmitter for multidrop mode and provide it with a unique polling address. 14 6337V103UK

6335QA02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM ATEX Installation drawing For safe installation of 6335A or 6337A the following must be observed. The module shall only be Installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. ATEX Certificate Marking KEMA 09ATEX0148X II 3 G Ex na [ic] IIC T6..T4 Gc II 3 G Ex ic IIC T6..T4 Gc II 3 D Ex ic IIIC Dc Standards EN 600790 :2012, EN 6007911:2012, EN 6007915:2010 T6: 40ºC to 60 ºC T4: 40ºC to 85 ºC Hazardous Area Zone 2 or Zone 22 41,42,43,44 / 51,52,53,54 44 43 42 14 13 12 11,12,13,14 21,22,23,24 Ex na [ic] Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 45 mh Co: 28 μf 41 54 53 CH1 11 24 23 Ex na Umax 35 VDC Ex ic Ui = 35 VDC Li = 10 μh Ci = 1.0 nf 52 51 22 21 CH2 6335A 6337A Revision date: 20140620 Version Revision V5R0 Page: 1/2 6337V103UK 15

6335QA02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM General installation instructions To avoid risk of ignition during installation and maintenance appropriate safety measures against electrostatic discharge (ESD) are to be considered. The sensor circuit is not infallibly galvanic isolated from the supply output circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. For installation in a potentialy explosive gas atmosphere, the following instructions apply: If the transmitter is applied in type of protection Ex na, it shall be installed in an enclosure that is Ex na certified according to IECEN 6007915, or Ex e certified and suitable for the application and correctly installed. Cable entry devices and blanking elements shall fulfill the same requirements For installation in a potentially explosive dust atmposphere, the following instructions apply: If the transmitter is supplied with an intrinsically safe signal "ic" and interfaces an intrinsically safe signal "ic" (e.g. a passive device), the transmitter shall be mounted in a metal enclosure that provides a degree of protection of at least IP6X according to EN/IEC 60529, and that is suitable for the application. Cable entry devices and blanking elements shall fulfill the same requirements. The surface temperature of the enclosure is equal to the ambient temperature 20K for a dust layer with a maximum thickness of 5 mm.. Revision date: 20140620 Version Revision V5R0 Page: 2/2 16 6337V103UK

6335QA01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM ATEX Installation drawing For safe installation of 6335D or 6337D the following must be observed. The module shall only be Installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. ATEX Certificate Marking Standards KEMA 09ATEX 0148 X II 1G Ex ia IIC T6..T4 Ga II 1D Ex ia IIIC Da I M 1 Ex ia I Ma EN600790:2012, EN6007911:2012, EN6007926:2007 Hazardous area Zone 0, 1, 2, 20, 21, 22 T4: 40 Ta 85ºC T5: 40 Ta 60ºC T6: 40 Ta 40ºC Non Hazardous Area 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 3.5μF 44 43 42 41 CH1 14 13 12 11 R Barrier 250 < R < 1100 ohm 51,52,53,54 Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 3.5μF 54 53 52 51 CH2 24 23 22 21 6335D 6337D R Barrier 11,12,13,14 and 21,22,23,24 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10μH Ci: 1.0nF Ex HART Communicator Revision date: 20140620 Version Revision V4R0 0Page: 1/2 6337V103UK 17

6335QA01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM General installation instructions To avoid risk of ignition during installation and maintenance appropriate safety measures against electrostatic discharge (ESD) are to be considered. The sensor circuit is not infallibly galvanic isolated from the supply output circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. For installation in a potentially explosive gas atmosphere the following instructions apply: To avoid risk of ignition due to electrostatic discharge (ESD) the transmitter shall be mounted in an enclosure providing a degree of protection of at least IP20 according to EN/IEC 60529. Ambient temperature range: T4: 40 Ta 85ºC T5: 40 Ta 60ºC T6: 40 Ta 40ºC For installation in a potentially explosive dust atmosphere, the following instructions apply: The transmitter shall be mounted in a metal enclosure or equivalent that is providing a degree of protection of at least IP6X according to EN/IEC 60529 that is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. The surface temperature of the enclosure is equal to the ambient temperature 20K for a dust layer with a maximum thickness of 5 mm. Ambient temperature range: T4: 40 Ta 85ºC For installation in a potentially explosive atmosphere in mines, the following instructions apply: The transmitter shall be mounted in an enclosure providing a degree of protection of at least IP6X according to EN/IEC 60529. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. Ambient temperature range: T4: 40 Ta 85ºC Revision date: 20140620 Version Revision V4R0 0Page: 2/2 18 6337V103UK

6335QI02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM IECEx Installation drawing For safe installation of 6335A or 6337A the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. IECEx Certificate Marking IECEx KEM.10.0084X Ex na [ic] IIC T6..T4 Gc Ex ic IIC T6..T4 Gc Ex ic IIIC Dc Standards IEC600790: 2011, IEC6007911:2011, IEC6007915:2010 T6: 40ºC to 60 ºC T4: 40ºC to 85 ºC Hazardous Area Zone 2 or Zone 22 44 14 41,42,43,44 / 51,52,53,54 43 42 41 13 12 11 11,12,13,14 21,22,23,24 Ex na [ic] Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 3.5 μf 54 53 52 CH1 24 23 22 Ex na U 35 VDC Ex ic Ui : 35 VDC Li : 10 μh Ci : 1.0 nf 51 21 CH2 6335A 6337A Revision date: 20140620 Version Revision V4R0 Page: 1/2 6337V103UK 19

6335QI02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM General installation instructions If the enclosure is made of nonmetallic materials or of painted metal, electrostatic charging shall be avoided. The sensor circuit is not infallibly galvanic isolated from the supply output circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. For installation in a potentialy explosive gas atmosphere, the following instructions apply: If the transmitter is applied in type of protection Ex na, it shall be installed in an enclosure that is Ex na certified according to IECEN 6007915, or Ex e certified and suitable for the application and correctly installed. Cable entry devices and blanking elements shall fulfill the same requirements For installation in a potentially explosive dust atmposphere, the following instructions apply: If the transmitter is supplied with an intrinsically safe signal "ic" and interfaces an intrinsically safe signal "ic" (e.g. a passive device), the transmitter shall be mounted in a metal enclosure that provides a degree of protection of at least IP6X according to EN/IEC 60529, and that is suitable for the application. Cable entry devices and blanking elements shall fulfill the same requirements. The surface temperature of the enclosure is equal to the ambient temperature 20K for a dust layer with a maximum thickness of 5 mm. Revision date: 20140620 Version Revision V4R0 Page: 2/2 20 6337V103UK

6335QI01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM IECEx Installation drawing For safe installation of 6335D or 6337D the following must be observed. The module shall only be installed by qualified personnel who are familiar with the national and international laws, directives and standards that apply to this area. Year of manufacture can be taken from the first two digits in the serial number. IECEx Certificate Marking Standards: IECEx KEM.10.0084X Ex ia IIC T6..T4 Ga Ex ia IIIC Da Ex ia I Ma IEC600790:2011, IEC6007911: 2011, IEC6007926:2006 Hazardous area Zone 0, 1, 2, 20, 21, 22 T4: 40 Ta 85ºC T5: 40 Ta 60ºC T6: 40 Ta 40ºC Non Hazardous Area 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 3.5 μf 44 43 42 41 CH1 14 13 12 11 R Barrier 51,52,53,54 Uo: 9.6 VDC Io: 28 ma Po: 67.2 mw Lo: 35 mh Co: 3.5 μf 54 53 52 51 CH2 24 23 22 21 6335D 6337D 250 < R < 1100 ohm R Barrier 11,12,13,14 and 21,22,23,24 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10 μh Ci: 1.0 nf Ex HART Communicator Revision date: 20140620 Version Revision V4R0 Page: 1/2 6337V103UK 21

6335QI01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM General installation instructions To avoid risk of ignition during installation and maintenance appropriate safety measures against electrostatic discharge (ESD) are to be considered. The sensor circuit is not infallibly galvanic isolated from the supply output circuit. However, the galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac during 1 minute. For installation in a potentially explosive gas atmosphere the following instructions apply: To avoid risk of ignition due to electrostatic discharge (ESD) the transmitter shall be mounted in an enclosure providing a degree of protection of at least IP20 according to EN/IEC 60529. Ambient temperature range: T4: 40 Ta 85ºC T5: 40 Ta 60ºC T6: 40 Ta 40ºC For installation in a potentially explosive dust atmosphere, the following instructions apply: The transmitter shall be mounted in a metal enclosure or equivalent that is providing a degree of protection of at least IP6X according to EN/IEC 60529 that is suitable for the application and correctly installed. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. The surface temperature of the enclosure is equal to the ambient temperature 20K for a dust layer with a maximum thickness of 5 mm. Ambient temperature range: T4: 40 Ta 85ºC For installation in a potentially explosive atmosphere in mines, the following instructions apply: The transmitter shall be mounted in an enclosure providing a degree of protection of at least IP6X according to EN/IEC 60529. Cable entries and blanking elements shall be used that are suitable for the application and correctly installed. Ambient temperature range: T4: 40 Ta 85ºC Revision date: 20140620 Version Revision V4R0 Page: 2/2 22 6337V103UK

CSA Installation drawing 6335QC02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Hazardous (Classified ) Location IS,Class I, Division 1, Group A,B,C,D T4..T6 Ex ia IIC T4..T6 Ga Class I, Zone 0, AEx ia IIC T4..T6 Ga Non Hazardous Location T6: 40 Ta 60ºC T4: 40 Ta 85ºC 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5 μf 44 43 42 41 CH1 14 13 12 11 R 11,12,13,14 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10 μh Ci: 1.0 nf Barrier 250 < R < 1100 ohm Co(Ca) > (CiCcable) Lo(La) > (LiLcable) 6335D2A 6337D2A Ex HART Communicator Installation notes. The Transmitter must be installed in a suitable enclosure to meet installation codes stipulated in The Canadian Electrical Code (CEC). Substitution of components may impair intrinsic safety. Revision date: 20140930 Version Revision V4R0 Page: 1/2 6337V103UK 23

CSA Installation drawing 6335QC02 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Hazardous (Classified ) Location IS,Class I, Division 1, Group A,B,C,D T4..T6 Ex ia IIC T4..T6 Ga Class I, Zone 0, AEx ia IIC T4..T6 Ga Non Hazardous Location T6: 40 Ta 60ºC T4: 40 Ta 85ºC 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5μF 44 43 42 41 CH1 14 13 12 11 R Barrier 250 < R < 1100 ohm 11,12,13,14 and 21,22,23,24 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10μH Ci: 1.0nF 51,52,53,54 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5μF 54 53 52 51 CH2 6335D2B 6337D2B 24 23 22 21 R Barrier Co(Ca) > (CiCcable) Lo(La) > (LiLcable) Ex HART Communicator Installation notes. The Transmitter must be installed in a suitable enclosure to meet installation codes stipulated in The Canadian Electrical Code (CEC). Channel 1 and Channel 2 are separate channels and therefore separate shielded cables shall be used for each channel. Substitution of components may impair intrinsic safety. Revision date: 20140930 Version Revision V4R0 Page: 2/2 24 6337V103UK

FM Installation drawing 6335QF01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Hazardous (Classified ) Location Class I, Division 1, Group A,B,C,D T4..T6 Class I, Zone 0, AEx ia IIC T4..T6 Non Hazardous Location T6: 40 Ta 60ºC T4: 40 Ta 85ºC 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5 μf 51,52,53,54 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5 μf 44 43 42 41 54 53 52 51 CH1 CH2 6335D2x 6336D2x 6337D2x x = A :One channel x = B :Two channel 14 13 12 11 24 23 22 21 R Barrier 250 < R < 1100 ohm R Barrier Ex HART Communicator 11,12,13,14 and 21,22,23,24 Ui: 30 VDC Ii: 120 ma Pi: 0.84 W Li: 10 μh Ci: 1.0 nf Installation notes For installation in Class I the Transmitter must be installed in a suitable enclosure to meet installation codes stipulated in The National Electrical Code (ANSINFPA 70). Equipment that is FMapproved for intrinsic safety may be connected to barriers based on the Entity Concept. This concept permits interconnection of approved transmitters, meters and other devices in combinations, which have not been specifically examined by FM, provided that the agency's criteria are met. The combination is then intrinsically safe, if the entity concept is acceptable to the authority having jurisdiction over the installation. The entity concept criteria are as follows: The intrinsically safe devices, other than barriers, must not be a source of power. The maximum voltage Ui(VMAX) and current Ii(IMAX), and maximum power Pi(Pmax), which the device can receive and remain intrinsically safe, must be equal to or greater than the voltage (Uo or VOC or Vt) and current (Io or ISC or It) and the power Po which can be delivered by the barrier. The sum of the maximum unprotected capacitance (Ci) for each intrinsically device and the interconnecting wiring must be less than the capacitance (Ca) which can be safely connected to the barrier. The sum of the maximum unprotected inductance (Li) for each intrinsically device and the interconnecting wiring must be less than the inductance (La) which can be safely connected to the barrier. The entity parameters Uo, VOC or Vt and Io, ISC or It, and Ca and La for barriers are provided by the barrier manufacturer. Revision date: 20140916 Version Revision V6R0 Page: 1/2 6337V103UK 25

FM Installation drawing 6335QF01 LERBAKKEN 10, 8410 RØNDE DENMARK. WWW.PRELECTRONICS.COM Hazardous (Classified ) Location Class I, Division 2, Group A,B,C,D T4..T6 Class I, Zone 2, IIC T4..T6 T6: 40 Ta 60ºC T4: 40 Ta 85ºC Non Hazardous Location Associated 41,42,43,44 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5 μf 51,52,53,54 Uo: 9.6 VDC Io: 28 ma Po: 67 mw Lo: 35 mh Co: 3.5 μf 44 43 42 41 54 53 52 51 CH1 CH2 14 13 12 11 24 23 22 21 apparatus Associated apparatus 11,12,13,14 and 21,22,23,24 Vmax: 35 VDC Li: 10 μh Ci: 1.0 nf 6335A2x 6336A2x 6337A2x x = A :One channel x = B :Two channel Ex HART Communicator Installation notes The Transmitter must be installed in a suitable enclosure to meet installation codes stipulated in The National Electrical Code (ANSINFPA 70). To assure a NonIncendive system the transmitter and associated apparatus must be wired in accordance with the associated apparatus manufacturers field wiring instructions and the circuit diagram shown above. Revision date: 20140916 Version Revision V6R0 Page: 2/2 26 6337V103UK

Document history The following list provides notes concerning revisions of this document. Rev. ID Date Notes 103 15/50 ATEX & IECEx M1 approval added 6337V103UK 27

We are near you, all over the world Our trusted red boxes are supported wherever you are All our devices are backed by expert service and a 5year warranty. With each product you purchase, you receive personal technical support and guidance, daytoday delivery, repair without charge within the warranty period and easily accessible documentation. We are headquartered in Denmark, and have offices and authorized partners the world over. We are a local business with a global reach. This means that we are always nearby and know your local markets well. We are committed to your satisfaction and provide PERFORMANCE MADE SMARTER all around the world. For more information on our warranty program, or to meet with a sales representative in your region, visit prelectronics.com.

Benefit today from PERFORMANCE MADE SMARTER PR electronics is the leading technology company specialized in making industrial process control safer, more reliable and more efficient. Since 1974, we have been dedicated to perfecting our core competence of innovating high precision technology with low power consumption. This dedication continues to set new standards for products communicating, monitoring and connecting our customers process measurement points to their process control systems. Our innovative, patented technologies are derived from our extensive R&D facilities and from having a great understanding of our customers needs and processes. We are guided by principles of simplicity, focus, courage and excellence, enabling some of the world s greatest companies to achieve PERFORMANCE MADE SMARTER. www.prelectronics.com