Installation Instructions High Impact Corner Guards

Similar documents
Installation Instructions

Installation Instructions 1500/1500W/G Wall Guard Important

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions 800/800W/855/G2-800 Handrails

Installation Instructions

Installation Instructions 2000/2000W/G Handrail

Installation Instructions 1000/1000W/G Handrail

Installation Instructions

Installation Instructions

Installation Instructions 1200/1255/G Handrails International Compliant

Installation Instructions 800/800W/855/G2-800 Continuous Bracket Handrails

Installation Instructions CR3/G2 BioBlend -3 Wood Chair Rail - Stock Length

Installation Instructions 3530VS/3530FVS/G2-3530VS/A3530VS HANDRAILS

Installation Instructions 3520WW/3520WWB Handrail

Installation Instructions HR910 International Compliant Handrail

Installation Instructions HR910 Handrail

Installation Instructions

WG-4 Wall Guard Installation Instructions

Walk-in Configurations

Installation Instructions Palladium Wall Panels - Demountable Factory Finished Edges and Field Cut Edges

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

CRASH RAIL INSTALLATION HEIGHT

CRASH RAIL INSTALLATION HEIGHT

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

11 6 Round Building Assembly Instructions

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation!

3" [76.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

IMPORTANT: WILL NOT FIT COUNTRYMAN MODELS

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

McCue Bumper Installation Instructions

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Track Rack. * Track Racks are not lockable

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Installation Guidelines

Assembly Instructions 10 X 10 Aluminum Roof Support

Dura-Lock Roof System

Tools Required. Bench Hardware. Bench Parts. Planter Hardware. Planter Parts. BENCH/PLANTER INSTALLATION GUIDELINES for

Install Instructions. SCR-48N Crash Rail. Please read these instructions thoroughly prior to beginning the SCR-48N Crash Rail installation!

Two Panel Frameless Bypass Door

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

Installation Instructions for. Handrail Component System

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Desk/Wall-Mount Rack

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

INSTALLATION INSTRUCTIONS. Level Rail With Cap: Page 2 Level Rail Without Cap: Page 8 Stair Rail: Page 12

Installation Instructions

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

96 (Standard Length)

3 1/2" [88.9mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

4-SIDED NAVAJO SHELTER ARIZONA MODEL INSTALLATION INSTRUCTIONS

4 1/2" [114.3mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

BIKE FILE (301)

TIP FOR GETTING STARTED

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

NX7 SERIES 5-1/2 HANDRAIL

Assembly Instructions 10 X 10 Aluminum Frame Building

Install Instructions. NewAge Steel Welded Tall Locker

Installation Instructions

Assembly Instructions

Installation Instruction

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

ALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.

Installation Instructions Ascend Ceiling Systems - Stainless Pan Ceilings

RAILING R A IL ING 51

Installation Instructions and Details

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Locker Pedestal Installation Instructions

Installation Guidelines

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

HANDRAIL HEIGHT PER LOCAL CODE AUTORITY

Box Track INSTALLATION INSTRUCTIONS

LCD TV WALL MOUNT INSTALLATION INSTRUCTIONS. DUAL Swing Arm (RFWD-110) WARNING

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

Assembly and Installation Guide

Workbench Instructions for Assembly

Mount to the Wall INSTALLATION MANUAL

DeckRail A Product of DeckRite LLC 3912 East Progress North Little Rock, AR Phone: (501) Fax: (501)

Important Loading Information. Tools Required. Meridian Lateral Files Instructions

BioPrism Solid Surface

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSTALLATION INSTRUCTIONS

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

BSM, GSM & GSS. Joint Kit Instruction. (Modified for IMPACT) (NSF Certified) Curved Glass Fresh Meat Delicatessen and Seafood Merchandisers

Level, Pliers, 3/8" Electric Drill, Carpenters Square, Tape Measure, Metal Hack Saw, Silicone Caulking, Screw Drivers (Regular & Phillips)

TREX PERGOLA INSTALLATION INSTRUCTIONS

ALUMINUM RAILING INSTALLATION INSTRUCTIONS. 1) Check Contents Of Packages: Verify that all parts have arrived and that they match the packing list.

JELD-WEN DesignGlide Barn Door Hardware System Installation (JII-90003)

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

SLAT WALL INSTALLATION GUIDE

Transcription:

Important [76mm] 2" [50.8mm] 1. Acclimate materials 24 hrs before installation. Maintain temperature controlled environment after installation 2. Install in accordance with manufacturer s installation instructions. Failure to do so will void the warranty..070" [1.8mm] [76mm].070" [1.8mm] 2" [50.8mm] Installation tips 1. Cut covers up to 1/16 (1.6mm) longer to ensure a tight fit. 2. Lubricate blades when cutting aluminum to reduce burrs. [76.4mm] 150 CG R 7 8 " [R21.2mm] 160 CG [76.2mm].070" [1.8mm] NOTE FOR 170CG 90º CORNER GUARD: CORNER BEAD OF WALL MUST BE 3 /4 [19mm] RADIUS TO ACCOMMODATE [76.4mm] 135º.070" [1.8mm] [76.2mm] 170 CG STUD AND BACKER (BY OTHER) (TYP) 130 CG SECTION VIEWS Recommended tools Safety Glasses, Tape Measure, Level, Power Drill, 1/4 Socket, Drill Bits - 1/4 masonry (concrete/concrete block), Power Miter Saw, 1O Blade with 60-80 Carbide Tipped Teeth IPC.393/REV.12

Components and Fasteners 150 V 160 V 170 V 130 V 150 A 160 A 170 A 130 A 151 TC 161 TC 171 TC 121 TC Wall Condition Specified Fasteners Inpro Part # Drywall/Wood #8 x 1-1/4 Phillips Flat-Head Self-Tapping Screw, #8 x 1-1/2 Phillips Indented hex washer head self-drilling screw HWK-HIGC4DW (4 foot) HWK-HIGC8DW (8 foot) HJWK-HIGC9DW (9 and 12 foot) Concrete/Concrete Block #8 x 1-1/2 Phillips Flat Head Sheet Metal Screw, #10 x 1-3/4 Phillips Pan Head Sheet Metal Screw and 1/4" Alligator Anchor HWK-HIGC4C (4 foot) HWK-HIGC8C (8 foot) HJWK-HIGC9C (9 and 12 foot)

Exploded View assembly #8 X 1 1/2 PHILLIPS INDENTED HEX WASHER SCREW TOP/BOTTOM 161 TC CAP TOP CAP #8 X 1 1/4 PHILLIPS FLAT HEAD

FIG. 1 1. Position aluminum retainer against wall, leaving allowance for bottom cap. Secure retainer to the wall using the preslotted holes on the retainer. See Figure 1. DRYWALL #8 x 1 1 /2" PHILLIPS INDENTED HEX WASHER SELF DRILLING SCREW, Note for concrete installation: Use the slotted tabs on the top and bottom caps to transfer and drill 1 /4" (6.5mm) holes into the ends of the retainer. Transfer the location of all mounting holes to the wall. Drill marked holes on wall using a 1 /4" (6mm) drill bit and position Alligator anchors into holes. Mount retainer on wall with #10 x 1 3 /4" Phillips pan head screws and tighten to secure. Note for 170 90 Bullnose Corner Guard: Corner bead of wall must be 3 /4" (19mm) radius to accommodate retainer. 5/16" [8MM] ALLOWANCE FOR BOTTOM CAP COVE BASE FIG. 2 TOP CAP #8 x 11/4" PHILLIPS FLAT HEAD 2. Overlap the retainer with the mounting tabs of the top and bottom caps and attach them to retainer. See Figure 2. When installing flexible top caps on custom angle corner guards, use cup washers and flat head screws to fasten the top caps to the retainer. See Figure 2a. Note for concrete installation: Overlap the retainer with the mounting tabs of the top and bottom caps and attach them to retainer and into the Alligator anchors using two, #8 x 1 1 /2" Phillips flat head screws per cap. BOTTOM CAP

FIG. 3 3. Position cover on retainer and adjust the top cap for a tight fit. Starting at the top, push cover onto retainer pressing over the entire length until it snaps into place. See Figure 3.