HD HD HD AND HD PHOTO-RADIOMETERS LG-2

Similar documents
LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

English. Operating manual. Photo-radiometers HD HD Keep for future reference. Companies / Brands of GHM

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

PORTABLES ANEMOMETERS

HD REV. 1.6 Aug. 28 th 2012 ENGLISH

PROFESSIONAL MEASUREMENT. Measuring Controlling Regulating. From our new partner, a new range of products for environmental measures

G H M GROUP HD 31 PART OF. [GB] Handheld multifunction data logger. Temperature. Humidity. Pressure. Air Speed. Light. Air Quality - CO 2

HD HD HD HD HD

UNI EN ISO 7726 UNI EN ISO 7730 UNI EN ISO UNI EN ISO 7933 UNI ENV ISO UNI EN ISO PPD t O. PHS DLE WCI PD f. WBGT Indoor. t r.

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

LI-192 Underwater Quantum Sensor

TECHNICAL DATA FOR INSTRUMENT EQUIPPED WITH PROBES AND MODULES

LI-193 Spherical Quantum Sensor

LP PYRHE 16 AV. ACTIVE with 4..20mA CURRENT output ACTIVE with 0..1V or 0..5V o 0..10V VOLTAGE output to be defined at the time of placing the order

The Standard for over 40 Years

The Standard for over 40 Years

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

- HD HD HD pag. 338 Portable ph meters. - HD HD pag. 342 Portable ph and conductivity meters

SOLAR MEASUREMENTS

LP PYRA 03. REV jan. 2007

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

INDIUM SENSOR. Type X.5 Series

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

LI-1500 Light Sensor Logger

HD50 SERIES WEB DATALOGGER

Broadbandradiometer specbos 1211

Model S471-LED Optometer

LP PYRA 03. REV jan. 2007

Ultraviolet (UV-Index) TOCON Datasheets

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

Handbook Ref No. IH001/Issue D File Ref: PR203-v5D.doc

INSTRUCTION MANUAL UV RADIOMETERS

SL 200 instrument can process the energy intensity emitted by the solar radiation in a precise place of the earth.

Spectroradiometer specbos 1201

Spectral Handheld Light Meters for accurate measurements of LED lighting. Mike Clark, Gigahertz-Optik GmbH on behalf of Te Lintelo Systems BV

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

Pyranometers SP- 100 Series SP -200 Series

Handbook Ref No. MH079/Issue E File Ref: UV2033vE.doc

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

LP PYRA 06. REV Jan. 2007

LP UVA 02. REV jan. 2007

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

JETI Specbos Instruments

LP PYRA 02. REV jan. 2007

CIE 220:2016 Characterization and Calibration Method of UV Radiometers

LP PYRA Introduction. 2 Working principle

Measuring the Performance of UV LED Light Sources

Spectral Light Meters for accurate measurements of LED lighting Mike Clark, Gigahertz-Optik GmbH

Light Sensors for Environmental Chambers

LI-250A. Light Meter Instruction Manual. Publication Number March, 2004

Advances in Measuring UV LED Arrays

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

LP SD18. [ GB ] Sunshine duration sensor

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

Spectral Reflectance Sensor SRS-NDVI

LP UVA Introduction. 2 Working Principle. TEL r.a. FAX

The Standard for over 40 Years

Product Information Wireless data loggers

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

Data logging Wireless

UV-Index Photodiodes Data Sheets

UV-Index Photodiodes Data Sheets

ILLUMINANCE METER T-10 Series

LED Tester BTS256-LED

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

Optometers & Instruments - Page 3

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

operating manual iliad for Windows & Mac OS X software application rc81

INSTRUCTION MANUAL PCE-222

Improved Radiometry for LED Arrays

Handbook Ref No. MH063/Issue L File Ref: L203-v5L.doc

Wireless data loggers GHM DeltaBus

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Light-Emitting Diodes

MAKING LIGHT WORK OF LIGHT MEASUREMENT. Guide to Photometer & Radiometer. System Configuration

RAMSES. A modular multispectral radiometer for light measurements in the UV and VIS

Influence of the light spectral distribution used in the radiometers calibration

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Manual DATALOGGING LIGHT METER - PCE-174

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Photometry and Light Measurement

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

User s Manual /51012/51021 Digital Lux Meter. Keep this manual in a safe place so that you can refer to it when necessary.

DEUTROFLUX. Accessories for Magnetic Particle Inspection. Field Strength Gauge DEUTROMETER II. In Actual Size

Detector-Filter Combination Series

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

High-precision portable RESISTANCE METER

Solid State Luminance Standards

Content of this Catalog. General information about the sglux TOCONs. Selection guide p. 2. Product details of all TOCONs p. 5. Useful accessories p.

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Data logging Wireless

GENII RADIO DATA LOGGING SYSTEMS

Radiometric and Photometric Measurements with TAOS PhotoSensors

Transcription:

HD 22. HD 22.2 INSTRUMENT TECHNICAL CHARACTERISTICS Instrument Dimensions (Length x Width x Height) 85x9x4mm Weight 47g (complete with batteries) Materials Display ABS, rubber 2x4½ digits plus symbols - 52x42mm Visible area: 52x42mm Operating conditions Operating temperature Storage temperature Working relative humidity Protection degree Power Batteries Autonomy Power absorbed with instrument off Mains -5 5 C -25 65 C 9%RH without condensation IP66 4.5V type AA batteries 2 hours with 8mAh alkaline batteries 2μA Output mains adapter 2Vdc / ma Measuring unit lux - fcd - lux s - fcd s - W/m 2 - µw/cm 2 J/m 2 - µj/cm 2 - µmol/(m 2. s) - µmol/m 2 - cd/m 2 µw/lumen Security of memorized data Time Date and time Accuracy Unlimited, independent of battery charge conditions in real time min/month max drift Measured values storage - model HD22.2 Type (for single probes) 2 pages containing 9 samples each Type (for combined probes) 2 pages containing 7 samples each Quantity (for single probes) total of 38 samples Quantity (for combined probes) total of 4 samples Selectable storage interval s, 5s, s, 5s, 3s, min, 2min, 5min, min, 5min, 2min, 3min, hour HD22. AND HD22.2 PHOTO-RADIOMETERS The HD22. and HD22.2 are portable instruments with a large LCD display. They measure illuminance, luminance, par and irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve). The probes are equipped with the SICRAM automatic detection module: in addition to detection, this unit of measurement selection is also automatic. The factory calibration data are already stored inside the instruments. In addition to instantaneous measurement the instruments calculate the acquired measurements time integral Q(t). Some thresholds can be associated with the integrated measurement and with the integration time, which can be set in the menu. When exceeded these thresholds cause the instrument to stop the integral calculation. The HD22.2 instrument is a datalogger. It stores up to 38, samples with a one-channel probe and up to 4, samples with combined probes. These data can be transferred from the instrument to a PC via the connection of the multi-standard RS232C serial port and USB 2.. Storing interval, printing and baud rate can be configured by using the menu. The HD22. and HD22.2 models are equipped with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer. The Max, Min and Avg functions calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be excluded. The instruments have IP66 protection degree. Serial interface RS232C Type RS232C electrically isolated Baud rate Can be set from 2 to 384 baud Data bit 8 Parity None Stop bit Flow Control Xon/Xoff Serial cable length Max 5m Selectable printing interval Immediate or s, 5s, s, 5s, 3s, min, 2min, 5min, min, 5min, 2min, 3min, hour USB interface - model HD22.2 Type Connections Input module for the probes RS232 serial interface USB serial interface Mains adapter. - 2. electrically isolated 8-pole male DIN45326 connector 8-pole MiniDin connector B-type MiniUSB connector 2-pole connector (positive at centre) Technical characteristics of photometric and radiometric probes equipped with SICRAM module for the connection to the instrument LP 47 PHOT probe for the measure of ILLUMINANCE Measuring range (lux):. 99.99 999.9 9999 99.99 3 Resolution (lux):... 3 Class B Calibration uncertainty: <4% f (in agreement with photopic response V(λ)): f 2 (response according to the <3% <.5% <.5%K Reference Standards CIE n.69 - UNI 42 LG-2 HD4. SWD Photometric probe for ILLUMINANCE measurement, spectral response in agreement with standard photopic vision, diffuser for cosine correction. Measurement range:. lux 2 3 lux.

LP 47 LUM 2 probe for the measure of LUMINANCE Measuring range (cd/m 2 ):. 999.9 9999 99.99 3 999.9 3 Resolution (cd/m 2 ):.. 3. 3 Optical angle: 2 Class C f (in agreement with photopic response V(λ)): <8% <.5% <.5%K Reference Standards CIE n.69 - UNI 42 Photometric probe for LUMINANCE measurement, spectral response in agreement with standard photopic vision, vision angle 2. Measurement range:. cd/m 2 2 3 cd/m 2. LP 47 RAD probe for the measure of IRRADIANCE. -3 999.9-3. 9.999 2. 99.99 2. 999.9 Resolution (W/m 2 ):. -3... 4nm 5nm f 2 (response according to the Radiometric probe for IRRADIANCE measurement in the spectral range 4nm 5nm, diffuser for cosine correction. Measurement range:. -3 W/m 2 2W/m 2. Typical response curve: LP 47 RAD Typical response curve: LP 47 PHOT and LP 47 LUM2,9,6,5, 38 43 48 53 58 63 68 73 78 83,6,5, LP 47 PAR quantum radiometric probe for the measure of the photon flow across the chlorophyll range PAR Measuring range (μmol m -2 s - ):. 99.99 2. 999.9 2 Resolution (μmol m -2 s - ):.. 35 4 45 5 55 6 65 7 75 8 85 4nm 7nm f 2 (response according to the Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range PAR (Photosynthetically Active Radiation 4nm 7nm), measurement in μmol/m 2 s. Measurement range:. μmol m -2 s - 3 μmol m -2 s -. Typical response curve: LP 47 PAR PAR,9,6,5, 35 45 55 65 75 85 95 5 LP 47 UVA probe for the measure of UVA IRRADIANCE. -3. 9.999 2. 99.99 2. 999.9 999.9-3 Resolution (W/m 2 ): -3.... 35nm 4nm (Peak 36nm),9,6,5, 28 3 32 34 36 38 4 42 Radiometric probe for IRRADIANCE measurement, in the 35nm 4nm, peak 36nm, UVA spectral range. Measurement range:. 3 W/m 2 2W/m 2. Typical response curve: LP 47 UVA LG-3 Light

LP 47 UVB probe for the measure of UVB IRRADIANCE. -3 999.9-3. 9.999 2. 99.99 2. 999.9 Resolution (W/m 2 ):. -3...,9,6,5, 28nm 35nm (Peak 35nm...3nm) f 3 (linearity): <2% Radiometric probe for IRRADIANCE measurement, in the spectral range 28nm 35nm, peak 35nm... 3nm, Measurement range:. 3 W/m 2 2W/m 2. Typical response curve: LP 47 UVB Combined probe LP 47 P-A with two sensors for the measure of ILLUMINANCE and UVA IRRADIANCE Illuminance Measuring range (lux):. 99.9 999.9 9999 99.99 3 Resolution (lux):... 3 <.5%K Calibration uncertainty: <4% f (in agreement with photopic response V(λ)): f 2 (response according to the <3% <.5% Class: B Reference Standards CIE n.69 - UNI 42 Please refer to the spectral response of the LP47PHOT probe UVA Irradiance Measuring range (μw/cm 2 ):. 99.99 999.9 9999 99.99 3 Resolution (μw/cm 2 ):... 3 35nm 4nm (Peak 36nm) f 2 (response according to the Please refer to the spectral response of the LP47UVA probe 25 26 27 28 29 3 3 32 33 34 35 LP 47 UVC probe for the measure of UVC IRRADIANCE. -3. 9.999 2. 99.99 2. 999.9 999.9-3 Resolution (W/m 2 ):. -3... 22nm 28nm (Peak 26nm) Radiometric probe for IRRADIANCE measurement, in the spectral range 22nm 28nm, peak 26nm, UVC. Measurement range:. 3 W/m 2 2W/m 2. LP SILICON-PYRA probe for the measure of GLOBAL SOLAR RADIATION Measurement range (W/m 2 ):. -3 999.9-3. 9.999 2. 99.99 2. 999.9 Resolution (W/m 2 ):. -3... 4 nm nm Calibration uncertainty: <3% f 2 (response according to the <3% f 4 (instrument reading error): ± digit f 5 (fatigue): <.5% Typical response curve: LP 47 UVC.5,9.25,6,5, Spectral irradiance Wm -2 nm -..75.5.25 Pyranometer LP PYRA 2, LP PYRA 3, LP PYRA Pyranometer LP Silicon-PYRA4 Solar spectrum A.M..5 LG-4 2 2 22 23 24 25 26 27 28 29 3. 25 5 75 25 5 75 2 225 25 275 3

t LP 47 A-UVeff probe for the measure of TOTAL EFFECTIVE IRRADIANCE weighted according to the UV action curve (CEI EN 6335-2-27) Total Effective Irradiance Measuring range (W eff /m 2 ):. 9.999 Resolution (W eff /m 2 ):. UV action curve for measuring erythema (25 nm 4 nm) Calibration uncertainty: <5% f 3 (linearity): <3% ± digit UV Irradiance Measuring range (W eff /m 2 ):. 999.9 Resolution (W eff /m 2 ):. UV_BC Irradiance 35 nm 4 nm Measuring range (W eff /m 2 ):. 9.999 Resolution (W eff /m 2 ):. 25 nm 35 nm LP 47 BLUE probe for the measure of IRRADIANCE in spectral band of BLUE LIGHT. Measurement range (W/m 2 ): -3. 9.999 2. 99.99 2. 999.9 999.9-3 Resolution (W/m 2 ):. -3...,2, 38 nm 55 nm. Action curve for damages of Blue light B(λ) Calibration uncertainty: <% f 2 (response according to the f 3 (linearity): <3% ± digit, 6,E+,E- UV action curve,e- LP47 A-UVeff spectral response, E-2,E-3,E-4,E-5 25 27 29 3 33 35 37 39, 35 4 45 The radiometric probe LP 47-BLUE measures irradiance (W/m 2 ) in spectral band of blue light. The probe consists of a photodiode plus an appropriate filter and it is provided with diffuser for proper measure in accordance with the cosine law. The spectral response curve of the probe allows to measure the radiation effective for damages caused by blue light (curve B(λ) according to the standards ACGIH / ICNIRP) in the spectral range from 38nm to 55nm. The radiation optics in this portion of the spectrum can produce photochemical damage to the retina. Another field of application is the monitoring of the probe irradiance from blue light used in the treatment of neonatal jaundice. 5 55 6 Light LG-5

ORDERING CODES HD22.: The kit consists of the instrument HD22., 4.5V alkaline batteries, operating manual, case and DeltaLog9 software downloadable from Delta OHM website. Probes and cable must be ordered separately. HD22.2: The kit consists of the HD22.2 datalogger, 4.5V alkaline batteries, operating manual, case and DeltaLog9 software downloadable from Delta OHM website, USB cable CP23. Probes and cable must be ordered separately. HD2CSNM: 8-pole connection cable MiniDin - Sub D 9-pole female for RS232C. C.26: Cable for the connection of the instrument HD2 to the PC USB ports directly. SWD: Stabilized power supply at 23Vac/2Vdc-mA mains voltage. HD4.: Portable, serial input, 24 column thermal printer, 58mm paper width. coded CP23, no USB driver installation is requested. B For the connection of the models HD2xx. to the RS232 port of your PC, the USB/ serial converter is available (code C.26). The converter is equipped with its own drivers that have to be installed before connecting the converter to the PC (please see the details in the CDRom supplied with the converter). C The port with the MiniDIN connector which is present on every model is an RS232C type. By means of the cable coded HD2CSNM, an RS232 port of a PC or the HD4. printer can be connected. Probes complete with SICRAM module LP 47 PHOT: Photometric probe for measuring ILLUMINANCE complete with SICRAM module, spectral response in agreement with standard photopic vision, Class B according to CIE n 69, diffuser for cosine correction. Measurement range:. lux 2 3 lux. LP 47 LUM 2: Photometric probe for measuring LUMINANCE complete with SICRAM module, spectral response in agreement with standard photopic vision, vision angle 2. Measurement range:. cd/m 2 2 3 cd/m 2. LP 47 PAR: Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range PAR (Photosynthetically Active Radiation 4nm 7nm) complete with SICRAM, measurement in μmol m -2 s -, diffuser for cosine correction. Measurement range:.μmol m -2 s - 3 μmol m -2 s -. LP 47 RAD: Radiometric probe for measuring IRRADIANCE equipped with SICRAM module; in the 4nm 5nm spectral range, diffuser for cosine correction. Measurement range:. -3 W/m 2 2W/m 2. LP 47 UVA: Radiometric probe for measuring IRRADIANCE equipped with SICRAM module; in the 35nm 4nm, peak 36nm, UVA spectral range, quartz diffuser for cosine correction. Measurement range:. -3 W/m 2 2 W/m 2. LP 47 UVB: Radiometric probe for measuring IRRADIANCE equipped with SICRAM module, in the 28nm 35nm, peak 35nm... 3nm, UVB spectral range, quartz diffuser for cosine correction. Measurement range:. -3 W/m 2 2 W/m 2. LP 47 UVC: Radiometric probe for measuring IRRADIANCE equipped with SICRAM module, in the 22nm 28nm, peak 26nm, UVC spectral range, quartz diffuser for cosine correction. Measurement range:. -3 W/m 2 2 W/m 2. LP 47 BLUE: Radiometric probe for measuring IRRADIANCE (W/m 2 ) in spectral band of blue light equipped with SICRAM module. 38 nm 55 nm, quartz diffuser for cosine correction. Measurement range:. 3 Weff /m 2 2 Weff /m 2. LP 47 P-A: Combined probe for measuring ILLUMINANCE (lux), with standard photopic response, and IRRADIANCE (μw/cm 2 ) in the UVA spectral range (35...4 nm, with peak at 36 nm). Both the sensors are equipped with diffuser for the correction according to the cosine law. Illuminance measuring range:. lux 2 3 lux Irradiance measuring range:. mw/m 2 2 W/m 2. This probe provides the ratio between UVA irradiance and illuminance in μw/lumen (quantity of interest in museums). The probe is equipped with SICRAM module and cable 2m long. LP 47 A-UVeff: Combined probe for measuring the TOTAL EFFECTIVE IRRADIANCE (W/ m 2 ) weighted according to the UV action curve. The probe is made of two sensors for the correct measure of the Total Effective Irradiance in the range 25...4nm. Both these sensors are equipped with a diffuser for the correction according to the cosine law. This probe supplies the Total effective irradiance (Eeff), the UV-CB effective irradiance and the UVA Irradiance. Total effective irradiance measuring range:. W/m 2 2 W/m 2. B_C effective irradiance measuring range:. W/m 2 2 W/m 2. UVA irradiance measuring range:. W/m 2 2 W/m 2. The probe is equipped with the SICRAM module and a cable 2m long. LP 47 PYRA 2, LP PYRA 3, LP PYRA, LP 47 Silicon-PYRA See page LG-7 LP BL: Base with levelling device for all the above-described probes except for the probes LP 47 LUM 2 and LP 47 PYRA. LP BL3: Jointed support for all the above-described probes except for LP 47 LUM 2 and LP 47 PYRA. A The models of portable data logger series HD2xx.2 has been implemented with a new serial port miniusb type HID (Human Interface Device). When making the connection to the PC by the USB cable type A - Mini USB B-type LG-6