FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

Similar documents
FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

INSTALLATION INSTRUCTIONS

MCR-304. Installation Instructions. Wireless Interface for Hard-Wire Control Panels 1. INTRODUCTION 2. SPECIFICATIONS. 1.

INSTALLATION INSTRUCTIONS

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

INSTALLATION AND SETUP GUIDE

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

User Manual. ProRF Encoder Transmitter & Receiver

Keychain Radio Remote Control System

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

WSA 8 BOX RELE Installation Manual

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

SSR VL-12P-xC-NCS

SSR-150xxx-40VL-12P-xC-xxxCS

User s Guide Instructions for Installation and Operation

User s Guide Instructions for Installation and Operation

User s Guide FM Transmitter

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

Using the USB Output Port to Charge a Device

Preliminary Data Sheet!

Radio Remote Controls Manual K Series

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Astra-R Kit Wireless Alarm System Operation Manual

Transmitter. User Manual. Firmware version 1.0 and greater

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Pocket Weatheradio with Tone and Vibrating Alert

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Field Hub Installation Guide. P/N Rev. C 05/15

MaxLite LED Self-Driven LiteBars

Series 3000 Model R-107A

Inovonics Wireless Product Catalogue

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Firmware Version d & higher Installation & Operation

T-L 810-T TRANSMITTER GUIDE

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

2015 RIGOL TECHNOLOGIES, INC.

WireMaster Coax BNC PN: Rev C 2/13

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

Dakota Alert. WMT-3000 Wireless Transmitter. Owner s Manual

Radio System Strobe Wizard Plus Freemask

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

Congratulations on your purchase of Tiger s electronic JUMBLE!

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

ArchiTech by Networx

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

Firmware Version d & higher Installation & Operation

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

User Manual January Opticom Infrared System RC790 Remote Coding Unit

Installation Guide. Delphi XM FM Direct Accessory. For Use With Roady2 and SKYFi2 Satellite Radio Receivers

SureCall TM CM800 65dB

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

COMMERCIAL TRANSMITTER INSTRUCTIONS

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

SSR V-12C. Industrial Switching Applications: Hellroaring Technologies, inc. P.O. Box 1521, Polson, Montana 59860

IRRIGATION 810-T TRANSMITTER GUIDE

Planishing hammer stand For use with SKU Planishing hammer

Digi-Stop. Installation & Operation

Glass Electrode Meter

Wireless Transceiver (TRV)

STI REPEATER HOW THE PRODUCT WORKS BEFORE YOU START. Installation and Operation Manual. Model: STI-34109

M2/M2A AC-DC Power Supply Operator s Manual

2.4GHZ WIRELESS SYSTEM FOR POLICE VIDEO RECORDING

MaxLite Linear Strip ECO Series

CRD 410 MANUAL FITTING INSERTER

Single Flex and Double Flex Couplings (i)

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Radio Remote Controls Manual K Series

IRRIGATION 810-R RECEIVER GUIDE

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Table of Contents. Safety Notices

Advanced Test Equipment Rentals ATEC (2832)

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

ISW-EN7016 Installation Guide

How to install your ecobee Switch+

Installation and Operating Manual. (version 4.05) AAS Access Control Station. Your Partner in Access Control

Copyright Teletronics International, Inc. Patent Pending

Owner s Manual & Safety Instructions

LT3000 ULTRASONIC LEVEL TRANSMITTER

Quik Bridge Loop Receiver Installation Instructions

EE4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

Digi-Fence. User Manual (all models) For All Models with Digital Readout Firmware version d & Higher

E3X-DRT21/SRT21/CIF11

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Digital Electronic Thermostat With RF

installation guide XMFM1

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Transcription:

FA401 Single Transmitter / Single Output Receiver FA401R Single Transmitter / Single Relay Output Receiver Frequency Agile 900MHz Installation Instructions 02305C Note: The FA401 is intended to be installed by professional security technicians. This receiver is intended for use with indoor security systems. Use in outdoor applications may impair performance.

Overview: FA401 and FA401R slave receivers fully supervise a single wireless transmitter. The FA401 has open collector Alarm and Fault outputs. The FA401R has Form-C Alarm and Fault relay outputs. FA401R receiver NOTE: TERMINALS ARE ADJACENT ACTIVATED LED / PROGRAMMING MODE LED TAMPERED LED LOW BATTERY LED INACTIVE LED RESET / DELETE BUTTON TRANSMITTER PROGRAMMING BUTTON TRANSMITTER CONTACT SELECTION HEADER TX PGM RESET/DEL PGM NO NC VALID DECODE TRANSMITTER PROGRAMMING HEADER FA401 receiver ACTIVATED LED / PROGRAMMING MODE LED TAMPERED LED LOW BATTERY LED INACTIVE LED RESET / DELETE BUTTON TRANSMITTER PROGRAMMING BUTTON TRANSMITTER CONTACT SELECTION HEADER TX PGM RESET/DEL PGM NO NC VALID DECODE TRANSMITTER PROGRAMMING HEADER 2001 INOVONICS Wireless Corporation 2 02305C LIT-FA401-INSTALL 8-Oct-01

Technical Specifications: Dimensions (housing): 6.38" x 3.60" x 1.10" Weight: 6.9 oz. Environmental: Operating temperature: 32-140F (0-60 C) Relative Humidity: 95% (non-condensing) Electrical: Power Requirement: 11-14 VDC Power Consumption: 120mA (max, relays activated) Typical: 40mA (quiescent) FA401R output relay Form C, 2A @ 120VAC, 2A @ 300VDC Receiver: Type: frequency-hopping spread spectrum Operating frequency: 902-928 MHz The VALID DECODE LED indicates transmissions from transmitters programmed to the receiver. The receiver programs the transmitter with the following fixed parameters: No EOL resistor. No Internal Contact. (The receiver will not support the FA200W or FA210W widegap internal magnet contact.) 60-second supervisory check-in. (The transmitter sends a supervisory signal every 60 seconds. Some transmitters check in at 150-second intervals.) The receiver, with a fixed 60-minute supervisory window, will declare the point inactive if no supervisory signal is received within 1 hour of the latest signal. The Fault Output is Latching for low battery or tamper faults. It is Follower for Inactive faults. The Alarm Output is Follower (follows the state of the transmitter). Note: FA transmitters have non-volatile memory. It is not necessary to reprogram transmitters after losing power or changing batteries. Press the transmitter reset button to restore programming. Installation: Power: Supply power and ground to terminals marked and on the terminal block. Mounting: Use supplied hardware to attach FA401 or FA401R housing to wall or surface. To route wiring out the back of the unit, use a small flat screwdriver or utility knife to remove the knockout in the housing base. If possible, orient the antenna side of the receiver toward the transmitter. This enhances reception. Opening the housing: Reset Button Access Cover: Insert small screwdriver in slot on left side. Hold cover lightly while prying. Install by inserting top latch and snapping in at bottom. ACTIVATED TAMPERED LOW BATTERY INACTIVE Frequency Agile Receiver by Inovonics Corporation Insert a small flat screwdriver behind pry point indicator nubs on top or bottom of the housing cover (4 places). Gently pry or twist the housing cover apart. 2001 INOVONICS Wireless Corporation 3 02305C LIT-FA401-INSTALL 8-Oct-01

Programming the transmitter: 1) Select Normally Open (NO) or Normally Closed (NC) transmitter contact by positioning the jumper on the receiver's 3-pin TRANSMITTER CONTACT SELECTION HEADER. 2) Plug programming cable to 3-pin TRANSMITTER PROGRAMMING HEADER on the receiver. Orientation of the cable connnector to the header pins makes no difference. 3) Press the TRANSMITTER PROGRAMMING BUTTON on the receiver. It is located next to the TX PGM HEADER. Hold for at least 1 second.the receiver goes into program mode. It exits as soon as the transmitter is programmed or times out after 30 seconds. 4) The PROGRAMMING MODE LED will flash if no transmitter has been programmed to the receiver. If the LED is on solid, press RESET / DELETE button to clear previous transmitter. 5) Connect the programming cable to 3-pin header on transmitter. Orientation of the connector to header pins does not matter. 6) Press the transmitter reset button. (Refer to pages 5 and 6 for locations of transmitter reset buttons.) 7) If programming is successful, program mode will terminate: the INACTIVE LED will go out immediately and the VALID DECODE LED will resume normal operation, flickering intermittently. Receiver Operation: Output activation: Output activation: The FA401 has open collector Alarm and Fault outputs. Output is open relative to ground. On activation, output pulls to common ground. The FA401R has Form C Alarm and Fault relay outputs. Output activation is indicated by illumination of the ACTIVATED LED. Note: if a receiver is being connected to a normally closed zone, the FA401R must be used. Connection to hardwire panels: When an FA401 or FA401R receiver is used with a hardwire security panel, the panel will typically supply power and ground to the receiver. When the ground supplied to the receiver is common to the return loops of the hardwire panel, use one wire to connect the FA401 receiver outputs to the zone input of the panel. The examples below show typical connections of both the FA401 and the FA401R. PANEL FA401R, configuration PANEL FA401R, configuration NOTE: GROUND AND RETURNS ARE NOT MON. NOTE: GROUND AND RETURNS ARE NOT MON. DC GROUND DC GROUND FAULT SUPERVISION ZONE FAULT ZONE RETURN ALARM ZONE RETURN ALARM ZONE FAULT ZONE RETURN FAULT ZONE ALARM ZONE ALARM ZONE RETURN EOL resistors, if required for configuration EOL resistors, if required for configuration PANEL FA401 NOTE: GROUND AND RETURNS ARE MON. DC GROUND RETURN FAULT SUPERVISION ZONE ALARM ZONE EOL resistors, if required 2001 INOVONICS Wireless Corporation 4 02305C LIT-FA401-INSTALL 8-Oct-01

FA200 Universal Transmitter Frequency Agile Series Transmitters FA200W Universal Widegap Transmitter FA202 Smoke Detector Batte r y Programming header Widegap Magnet not supported by the FA401 Battery terminals Program contacts: or, as needed Typical battery life: 3 years Battery type: 4.5V alkaline battery pack Switch trigger: 1.5 seconds, minimum Dimensions: 1.25" x 6.00" x 0.750" Program contacts: Typical battery life: 1 year 2 Batteries: 3.0V lithium Dimensions: 6.0" Diameter Note: Remove jumper to program, replace jumper after programming. FA203 Pendant Transmitter FA204 Pendant Transmitter FA205 Beltclip Transmitter Programming h d 3.0V + + 3.0V 3.0V + Program contacts: Typical battery life: 3-5 years Battery (or equivalent): 3.0V lithium Sanyo CR2 Dimensions: 3.10" x 1.62" x 0.750" * To extend battery life, actual check-in interval of the FA203 is 2 to 3 times the programmed value. Programming header Note: Remove battery cover to access Reset Button and Programming Head Program contacts: Typical battery life: 2 years Battery 3.0V Sanyo LiMn CR14250 Dimensions: 2.8" x 1.7" x 0.83" Program contacts: Typical battery life: 3-5 years Battery (or equivalent): 3.0V lithium Sanyo CR2 Dimensions: 3.10" x 1.62" x 0.750" * To extend battery life, actual check-in interval of the FA205 is 2 to 3 times the programmed value. FA206S PIR Motion Detector FA206DS PIR Motion Detector FA207 Glassbreak Detector Reset Button Programming header 3.0V + (with tamper shunt) + 3.0V Battery Program contacts: Typical battery life: 2 years (with 2 batteries) Battery: 3.0V lithium DL123A Sleep after trip: 90 seconds Dimensions: 3.75" x 2.88" x 2.40" Sensitivity selector Walk test LED Mirror Optics Program contacts: Typical battery life: 2 years Battery: 3.0V lithium DL123A Sleep after trip: 180 seconds Dimensions: 3.75" x 5.75" x 2.50" + 3.0V Program contacts: Typical battery life: 2 years Battery: 3.0V lithium DL123A Dimensions: 4.25" x 3.12" x 1.63" Note: Remove jumper to program, replace jumper after programming. Note: Batteries are always supervised. Lithium batteries are capacity-tested at 18-hour intervals. Typical battery life is based on 60-second check-in. The transmitter will deactivate 2 weeks after low battery is detected. Test weekly. 2001 INOVONICS Wireless Corporation 5 02305C LIT-FA401-INSTALL 8-Oct-01

FA209 Billtrap Transmitter Frequency Agile Series Transmitters (Continued) FA210 Reduced-size Universal Transmitter FA210W Reduced-size Universal Widegap Transmitter Delay selector 3V LITHIUM 3V LITHIUM Program contacts: Typical battery life: 1-2 years Battery type (Qty. 2): 3.0V lithium CR2450N Dimensions: 2.63" x 6.19" x 0.750" + 3.0V Program contacts: or, as needed Typical battery life: 4 years Battery type: 3.0V lithium DL123A Switch trigger: 1.5 seconds, minimum Dimensions: 3.55" x 1.70" x 0.920" Widegap Magnet not supported by the FA401 FA250 High PowerTransmitter Tamper Switch 3.0V + Reset Button Programming Header External contact Terminals Program contacts: or, as needed Typical battery life: 1-2 years Battery type: 3.0V lithium DL123A Switch trigger: 1.5 seconds, minimum Dimensions: 1.25" x 6.00" x 0.750" Note: Batteries are always supervised. Lithium batteries are capacity-tested at 18-hour intervals. Typical battery life is based on 60-second check-in. The transmitter will deactivate 2 weeks after low battery is detected.test weekly. 2001 INOVONICS Wireless Corporation 6 02305C LIT-FA401-INSTALL 8-Oct-01

Warranty & Disclaimer Inovonics Wireless Corporation ("Inovonics") warrants its products ("Product" or "Products") to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of twenty-four (24) months from the date of manufacture. Within the warranty period Inovonics will repair or replace, at its option, all or any part of the warrantied product. Inovonics will not be responsible for dismantling and/or reinstallation charges. To exercise the warranty, the User ("User", "Installer" or "Consumer") must be given a Return Material Authorization ("RMA") Number by Inovonics. Details of shipment will be arranged at that time. This warranty does not apply in cases of improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than Inovonics. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express, or implied, including any warranty of merchantability or fitness for a particular purpose. Inovonics will not be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties. This warranty will not be modified, varied or extended. Inovonics does not authorize any person to act on its behalf to modify, vary or extend this warranty. This warranty will apply to Inovonics Products only. All other products, accessories or attachments used in conjunction with Inovonics equipment, including batteries, will be covered solely by their own warranty, if any. Inovonics will not be liable for any direct, incidental or consequential damage or loss whatsoever, caused by the malfunction of Product due to products, accessories, or attachments of other manufacturers, including batteries, used in conjunction with Inovonics Products. This warranty does not warrant the replacement of batteries that are used to power Inovonics Products. The User recognizes that a properly installed and maintained security system may only reduce the risk of events such as burglary, robbery, personal injury and fire. It does not insure or guarantee that there will be no death, personal damage and/or damage to property as a result. Inovonics does not claim that the Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. Inovonics shall have no liability for any death, injury or damage, however incurred, based on a claim that Inovonics Products failed to function. However, if Inovonics is held liable, directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, Inovonics' maximum liability will not in any case exceed the purchase price of the Product, which will be fixed as liquidated damages and not as a penalty, and will be the complete and exclusive remedy against Inovonics.! Warning: The User should follow all installation, operation and maintenance instructions. The User is strongly advised to conduct Product and systems tests at least once each week. Changes in environmental conditions, electric or electronic disruptions and tampering, may cause the Product to not perform as expected.! Warning: Inovonics warrants its Product to the User. The User is responsible for exercising all due prudence and taking necessary precautions for the safety and protection of lives and property wherever Inovonics Products are installed. Inovonics strongly advises the User to program Products to be supervised whenever used in applications affecting life safety. Users are warned that unsupervised devices are subject to undetected failure due to malfunction, battery failure, tampering, or changes in environment. 2001 INOVONICS Wireless Corporation 7 02305C LIT-FA401-INSTALL 8-Oct-01

Frequency Agile Receivers from Inovonics: FA401 FA401R FA404 FA404R FA416 FA416D FA416R FA416DR FA464DR 1-transmitter / Single output 1-transmitter / Single relay output 4-transmitter / Single output 4-transmitter / Single relay Output 16-transmitter / 4-output 16-transmitter / 4-output with display 16-transmitter / 4-relay output 16-transmitter / 4-relay output with display 64-transmitter / 16-relay output with display Receiver Accessories: FA116 FA516 FA541 Executive Programmer for FA416 / FA464 Display module for FA416 and FA416R Single form C relay module Inovonics Wireless Corporation 315 CTC Blvd Louisville CO 80027 FAX: (303)939-8977 E-MAIL: support@inovonics.com www.inovonics.com Sales and Technical Service: 800-782-2709 2001 INOVONICS Wireless Corporation 8 02305C LIT-FA401-INSTALL 8-Oct-01