SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Similar documents
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SOCIETY OF CABLE TELECOMMUNICATIONS ENGINEERS INC

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

CUSTOM DESIGN COAXIAL CABLES BY SICAB

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Detailed Specifications & Technical Data

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, UNARMORED M17/74-RG213, AND ARMORED M17/74-RG215

AMERICAN NATIONAL STANDARD

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, M17/6-RG11 UNARMORED, M17/6-RG12 ARMORED

COAX 101. Author: Rob Wessels. Vice President of Engineering

Drop Cable Product Catalog

S-Link. RF Cable Solution

Detailed Specifications & Technical Data

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/28-RG058

AMERICAN NATIONAL STANDARD


Detailed Specifications & Technical Data

Connection technology for wireless communication systems

CIR (Crush & Impact Resistant) VFD Power Cable

MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE

EXCELLENT ELECTRICAL PERFORMANCES

Field Instrument Cable. Electrical Noise

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/60-RG142.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Detailed Specifications & Technical Data

LTE high-performance coaxial cables (RG replacement)

MIL-C-17 Standard RF Coaxial Cable Low Loss & Ultra Low Loss RF Microwave Cable ANTENNA & TEST Cable up to 26.5 GHz

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS

Standards Update Notice (SUN) Issued: June 6, 2017

INTERNATIONAL STANDARD

Detailed Specifications & Technical Data


C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

REQUEST FOR INFORMATION (RFI) RFI NO: /WJG

NETWORK CONNECTIVITY SYSTEMS

To offer our customer the highest quality Broadband products at a competitive price with efficient Delivery and Inventory.

C400-TMTM-30-X. Jumper Assembly Sample Label. Product Classification. General Specifications. Electrical Specifications

Surge Protection and Grounding Issues

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

C400-NMTM-1M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

RG58 Coaxial Cable: 2) Approval:

Underground System Design TADP 547

Part Number: 7953A Cat 6 600V DataTuff, (4 pr) 23 AW G Solid BC, PP/PVC/PVC, Foil Shld, CMR, CMX-Outdoor

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Speedflex. Halogen free coaxial cables.

SMB Plug Connector Crimp/Solder Attachment for RG174, RG316, RG188, LMR-100, PE-B100, PE-C100, inch

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

LMR LMR Ohm Flexible Low Loss Coaxial Cable TIMES MICROWAVE SYSTEMS

C195-SMQM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188 Gold Plated

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

Edition January 2008

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

14 AWG 2 AWG: 600 Volt

COPPER + LWL RAW CABLES

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Measurement Procedure for Noise Power Ratio

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

AMERICAN NATIONAL STANDARD

Cable Type 100. CAI Certification Specification

RF Connectors Technical Data Sheet. Description Minimum Typical Maximum Units. Frequency Range DC 3 GHz VSWR 1.25:1 Operating Voltage (AC) 335 Vrms.

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less

Times Microwave Systems Hermetically Sealed Assemblies

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

ENGINEERING COMMITTEE

Cable Type 125. CAI Certification Specification

Current Probes. User Manual

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

GEXOL WORLD CLASS OIL & GAS CABLES

Broadband Current Probe Series Operation Manual

ELESUN PRODUCT MANUAL. Jiangsu Elesun Cable Co.,Ltd. Jiangsu ElesunCable Co.,Ltd

RP TNC Male Connector Crimp/Solder Attachment for PE-C240, RG8X, inch, LMR-240, LMR-240-DB, LMR-240-UF, B7808A

Low Loss Pre-Connectorized Cable Sets, LL58 Series, DC-3.5GHz

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

Telecommunication Wiring Questions

MULTIMEDIA CABLE H6091ZHB

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Chapter 12: Transmission Lines. EET-223: RF Communication Circuits Walter Lara

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method For Coaxial Cable Impedance

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Canadian OSP Copper I-1. Table of Contents

Advanced Test Equipment Rentals ATEC (2832)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Transcription:

SBCA Industry Standards Subcommittee Document: SBCA Series 6 Recommended Practices Date of Issue: Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

NOTICE The Satellite Broadcasting and Communications Association (SBCA) recommended practices are intended to serve the public interest by providing specifications, test methods and procedures which promote uniformity of product, interchangeability and ultimately improve the long-term reliability of digital broadcast services. These SBCA recommended practices do not endorse or encourage the use of any particular brands or any particular manufacturer s product. SBCA s recommended practices are advisory only. SBCA does not require adoption of these standards for membership in SBCA, for the National Standards and Testing Program (NSTP) certification or for any other purpose. These recommendations shall not, in any way preclude any manufacturer, distributor, retailer or installer, whether SBCA member or not from manufacturing, distributing, selling or using products not conforming to these documents, by those other than SBCA members, whether used domestically or internationally. SBCA assumes no obligations or liability whatsoever to any party who may choose to adopt the recommended practices. Such adopting party assumes all risks associated with adoption of these practices and accepts full responsibility for any damages and/or claims arising form the adoption of such practices. All Rights Reserved Published by Satellite Broadcasting and Communications Association Inc. 225 Reinekers Lane, Suite 600 Alexandria, VA 22314 USA i

TABLE OF CONTENTS INTRODUCTION... 2 1.0 SCOPE... 2 2.0 CENTER CONDUCTOR... 2 3.0 DIELECTRIC... 3 4.0 FIRST OUTER CONDUCTOR... 4 5.0 CORE (DIELECTRIC + LST)... 4 6.0 BRAID WIRE... 5 7.0 JACKET... 5 8.0 FINISHED PRODUCT TESTS... 7 1

INTRODUCTION This specification is intended to apply to general-purpose flexible Series 6 Type, 75-ohm RF coaxial drop cable used in the satellite broadcast industry. Reference to the National Electrical Code, National Electrical Safety Code and other regulations or specification should adhere to the latest document and should keep current with each document. This specification (standard) in no way should limit or restrict any manufacturer s innovation and improvement. Innovations and improvements are encouraged and this specification (standard) may be adjusted when beneficial 1.0 SCOPE 1.1 This specification applies to material, electrical and mechanical properties of Series 6 Type, 75-ohm DBS coaxial drop cables as defined herein. 1.2 75-ohm coaxial cables are used to distribute radio frequency (RF) signals. 2.0 CENTER CONDUCTOR 2.1 Material 2.2 Joints The center conductor shall be solid round copper wire intended for electrical purposes. The copper shall meet the requirements of ASTM B1. Factory joints in the finished product shall be allowed. The ultimate tensile strength in the joint area when tested per ASTM E-8 shall be 95 percent of the original unspliced wire. 2.3 Dimensions 2.3.1 Center conductor dimensions shall meet the requirements of Table 2.0 2.3.2 Center conductor tolerance shall be ± 1%. Table 2.0 Center Conductor Diameter Series 6 (inches) 0.0403 (mm) 1.02 2

2.3.3 Mechanical 2.3.3.1 Tensile strength and elongation properties of the copper conductor shall be as indicated in Table 2.1 2.4 Electrical Table 2.1 Center Conductor Minimum Mechanical Properties 0.0403 Cu minimum Tensile Strength, psi 67,000 Elongation, % 0.85 2.4.1 The center conductor electrical conductivity shall be 96.2 percent IACS, minimum, or 1.793 mω cm. 2.4.2 Maximum DC Resistance shall be measured per SCTE IPS TP008 and meet the requirements of Table 2.2. Table 2.2 Maximum Resistance in Ohms @ 68ºF (20ºC) 0.0403 Cu 6.77 Ω / kft, 22.2 Ω / km 3.0 DIELECTRIC 3.1 Material 3.1.1 Dielectric material extruded over the center conductor shall be an insulating grade virgin polyethylene and shall not contain reground, reprocessed or recycled materials. The insulation shall consist of gas injected foamed polyethylene with a closed cell structure. It shall be applied concentrically and bonded to the center conductor. The dielectric shall also contain a stabilization package to meet the requirements of section 8.1.4 Thermal Oxidative Stability (TOS). 3.1.2 Unless otherwise specified, polyethylene materials for the dielectric shall meet all applicable requirements of ASTM D 1248 and requirements of this document. 3

3.2 Mechanical 3.2.1 Nominal Dielectric Diameter (See Table 3.0) Table 3.0 Dielectric Diameter Series 6 (inches) 0.180 (mm) 4.57 4.0 FIRST OUTER CONDUCTOR 4.1 Material 4.1.1 The first outer conductor shall be a Laminated Shielding Tape (LST). The LST shall be constructed of two aluminum foils laminated to a strength member and a bonding resin on one side. (See Table 4.0). Table 4.0 LST Thickness Dimensions max Min (inch) 0.0032 0.00186 (micron) 81.28 47.24 4.1.2 The LST shall overlap the dielectric circumference by 18 percent minimum to 35 percent maximum on the finished product. 4.1.3 The LST shall be applied longitudinally to the dielectric and shall be free of creases or twists over the entire length. 5.0 CORE (DIELECTRIC + LST) 5.1 Average Core Diameter 5.1.1 The average core diameter shall be determined by measuring the diameter over the LST in the finished product as described in ANSI/SCTE 31. 4

Average Core Diameter (See Table 5.0). SBCA series 6 recommended practices.doc Table 4.0 Core Diameter (inches) 0.188 ± 0.005 (mm) 4.78 ± 0.13 5.2 Core Ovality 5.2.1 Core ovality shall be determined by subtracting the measured minimum from the measured maximum diameter over the LST in the finished product. 5.2.2 Maximum Core Ovality 0.013 (0.33 mm). 6.0 BRAID WIRE 6.1 Material 6.1.1 The braiding wire shall be a round aluminum wire consisting of 34 AWG size (0.0063 ± 0.0003 inches), (0.160 ± 0.01 mm), or 36 AWG size (0.0050 ± 0.0003 inches), (0.127 ± 0.01 mm), using an alloy of 5056, 5154, 5154A, or 5954. 6.2 Mechanical 7.0 JACKET 6.2.1 Minimum tensile strength for individual strands of aluminum alloy braid wire shall be 43,000 psi. 6.2.2 Minimum elongation for individual strands of aluminum alloy braid wire shall be 3 percent. 6.2.3 Braid coverage over the first outer conductor shall be a minimum of 59 percent for single braided products. The braid coverage shall be determined by ANSI/SCTE 51. 7.1 Material 7.1.1 Polyvinylchloride (PVC) compound may be used for aerial and indoor applications. 7.1.2 Polyethylene (PE) compound may be used underground or aerially. 7.1.3 Cables intended for indoor or outdoor use shall meet the latest requirements of the National Electrical Code (NEC), Articles 810 and 820 in accordance with local building codes and ordinances where 5

cable is installed. As a recommended minimum, the following guidelines should be used for indoor installations: Residential Installations: NEC CATVX or CMX Listed Commercial Installations: NEC CATV or CM Listed Remember ALWAYS check the local building codes and with local building inspectors or fire marshals to ensure that the proper cable listing is used for the intended application. 7.1.4 The jacket material shall be UV stable, as defined in UL 1581, paragraph 1200, Reference Standard for Electric Wire, Cables and Flexible Cords, 720 Hour Sunlight Resistance Test 7.1.5 Cables for indoor, aerial or underground applications may contain corrosion protection materials applied between the cable jacket and cable outer conductor. Corrosion protection shall be tested as described in ANSI/SCTE 69. 7.1.6 Cables intended for aerial or indoor applications, which contain a corrosion protection material, shall meet the non-flowing requirement as described in ANSI/SCTE 11. 7.2 Mechanical 7.2.1 The diameter over the jacket (DOJ) shall be measured as described in ANSI/SCTE 33 (See Table 7.0 for standard cable DOJ). Table 7.0 Standard Cable Diameter Over Jacket (DOJ) Series 6 (inches) 0.273 ± 0.008 (mm) 6.93 ± 0.203 7.3 Integral Static Ground Wire (ISGW) Web 7.3.1 The size and type of the ISGW shall comply with the requirements of the National Electrical Code (NEC), Article 810, Section 21, Paragraph H, and local building code requirements. As reference; a typical ISGW is 17 AWG, Copper Clad Steel. 7.3.2 The ISGW must separate from the cable in the web area without leaving any visible signs of splits, holes or grooves as specified in ANSI/SCTE 61. 6

8.0 FINISHED PRODUCT TESTS SBCA series 6 recommended practices.doc 8.1 Mechanical 8.1.1 The cable must be able to withstand a Cold Bend Test at -40 F/C with PVC jacket and -67 F (-55 C) with PE jacket. No visible damage to the jacket is allowed, as described in ANSI/SCTE 09. 8.1.2 The cable must be able to withstand an impact test without damaging the jacket. The test is to be conducted at 5 F (-15 C) for cables with PVC jackets and at -22 F (-30 C) for cables with PE jackets, as described in ANSI/SCTE 10. 8.1.3 Jacket longitudinal shrinkage shall be no more than 5 percent of the length under test as specified in SCTE IPS-TP003 (applicable to cables with PE jackets only). 8.1.4 Thermal Oxidative Stability To ensure the desired life expectancy of the dielectric insulation, determine its Oxidative Induction Time (OIT) before and after aging by measuring OIT according to ASTM D 4565, Section 17. The test utilizes insulation removed from the completed cable. Requirements for OIT Initial: 20 minutes minimum, after aging: 70 percent of initial value. 8.1.5 Center conductor bond to dielectric shall be as specified in Table 8.0 and measured per ANSI/SCTE 59. 8.2 Electrical Table 8.0 Center Conductor Bond To Dielectric Series 6 Minimum (lbs) 5 Minimum (kg) 2.3 8.2.1 Velocity of Propagation (Vp) shall be 82 percent minimum when measured per ANSI/SCTE 49. 8.2.2 Impedance; 75 ± 3 ohms when measured per SCTE IPS-TP006. 8.2.3 Minimum Structural Return Loss; 20 db in the frequency range 5 1000 MHz when measured per ANSI/SCTE 03, and 15 db in the frequency band of 1001 2250 MHz when measured per ANSI/SCTE 03, except Fixed Bridge method using the listed start and stop frequency. 7

8.2.4 The maximum DC Loop Resistance for a 59 percent braid and one LST shall be as specified in Table 8.1 when measured per SCTE IPS- TP008. Table 8.1 Maximum DC Loop Resistance @ 68 F (20 C) Series 6 Ω / kft Ω / km Loop 20.00 65.6 8.2.5 The maximum attenuation shall be as specified in Table 8.2 when measured per SCTE IPS-TP009. 8.2.6 The cable ampacity shall be determined per ANSI/SCTE 32. 8.2.7 The overall cable jacket integrity shall be subject to a spark test with a minimum 2.5 kv rms to ensure the absence of faults in the jacket during manufacturing. 8.2.8 The dielectric between inner conductor and outer conductor of the cable shall withstand without breakdown, for one minute, an alternating voltage of 1000V at a frequency of 60 Hz at room temperature as described in SCTE IPS-TP012. 8

Table 8.2 Maximum Attenuation @ 68 F (20 C) Series 6 Attenuation Frequency (MHz) db/100 feet db/100 meters 5 0.57 1.87 55 1.60 5.25 211 2.87 9.43 250 3.12 10.24 270 3.24 10.63 300 3.43 11.25 330 3.61 11.84 350 3.72 12.20 400 4.00 13.12 450 4.28 14.04 500 4.51 14.80 550 4.76 15.62 600 4.98 16.34 750 5.62 18.44 870 6.09 19.99 950 6.50 21.33 1000 6.54 21.46 1450 8.00 26.25 1750 8.74 28.67 2050 9.46 31.04 2250 10.00 32.81 9

GLOSSARY Attenuation: The decrease in magnitude of a wave as it travels through any transmitting medium, such as cable or circuitry. It is the difference between transmitted and received power. Coaxial Cable: A type of cable used for broadband data cable and satellite systems. Composed of a center conductor, insulating dielectric, conductive shield and optional protective covering. This type of cable has excellent broadband frequency characteristics, noise immunity and physical durability. In a DBS system the transmission cable from the antenna dish to a dwelling. Conductivity: The ability of a material to allow electrons to flow, measured by the current per unit of voltage applied. It is the reciprocal of resistivity. Core Ovality: The difference between the minimum and maximum dimensions over the first Laminated Shield Tape. DC Resistance: The opposition a material offers to current flow, measured in ohms. DC Loop Resistance: A resistance measurement of the center conductor and outer conductor when hooked in series (measured in ohms/1000 feet). Dielectric: A nonconductive insulator material between the center conductor and outer conductor of coaxial cable. Dielectric Withstand: The ability of the cable insulation to withstand a minimum Voltage. Impedance: The total opposition a circuit, cable or component offers to alternating current flow. It includes both resistance and reactance and is generally expressed in ohms and designated by the symbol Z. Ohm: The electrical unit of resistance. The value of resistance through a potential difference of one volt will maintain a current of one ampere. Radio Frequency (RF): The frequency region of the electromagnetic spectrum that is between audio frequencies and infrared. Spark Test: A test procedure to check the outer jacket continuity and insulation integrity of a coaxial cable. Static Ground: Copper covered steel conductor (or other material) typically used alongside the DBS cables and integrated with the same outer jacket in a figure-eight design for grounding purposes. Structural Return Loss (SRL): Magnitude of the internal cable reflections, measured in decibels (db), relative to the actual cable impedance, no the system impedance. Velocity of Propagation (VP): The transmission speed of electrical energy in a length of a cable compared to the speed of light in a vacuum. Usually expressed as a percentage. 10

ABREVIATIONS: ANSI ASTM NEC NFPA IEEE UL db AWG American National Standards Institute American Society for Testing and Materials National Electrical Code National Fire Protection Association Institute of Electrical and Electronic Engineers Underwriters Laboratories Decibel American Wire Gauge 11

REFERENCES The following standards form a part of the Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite Installations Specification and associated test methods to the extent indicated herein. ANSI/UL1581 ASTM D 4565 ASTM B1 ASTM B193 IEEE Jones Dictionary NFPA-70-2002 SCTE SP-001 Reference Standard for Electrical Wires, Cables and Flexible Cords Physical and Environmental Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable Standard Specification for Hard-Drawn Copper Wire Resistivity of Electrical Conductive Materials Standard Dictionary of Electrical and Electronic Terms Cable Television Terminology 3 rd Edition National Electrical Code Society of Cable Telecommunications Engineers Specification for Flexible RF Coaxial Drop Cable 12