Table Of Contents. 11, 12 Thermostat Cable 39

Similar documents
Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

For tough, seaworthy wire

02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

DLO Flexible Power Cable

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

CIR (Crush & Impact Resistant) VFD Power Cable

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

SIMpull THHN, it slips and slides - all with NoLube.

Communication, Control, and Industrial Cable

MEDIUM VOLTAGE

IMSA TRAFFIC SIGNAL CABLE

High Temperature Flexible Control Cable

14 AWG 2 AWG: 600 Volt

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

SUPERIOR MARINE CABLE SOLUTIONS

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Creating. There is one basic question every customer needs to address when creating custom

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

Airport Cables & Connectors

SPEC 44. Wire and cable

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

3 Heat Shrinkable Products

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

SECTION Q WIRE AND CABLE Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:


LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

High Performance Wire and Cable

GEXOL WORLD CLASS OIL & GAS CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

TYGADURE FOR EXTREME APPLICATIONS

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

High Temperature Flexible Control Cable OLFLEX

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

PART NO COLOR SIZE DESCRIPTION P298 TKBOX Black 13.5 x 9.5 x 2 TERMINAL KIT BOX

THHN12STGN500 THHN 12 STR Green 500

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

THHN2BK2500 THHN 2 STR Black 2500

Instrumentation Cables

ELECTRONIC WIRE,CABLE AND TUBING FOR THE TWENTY-FIRST CENTURY AND BEYOND

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Selection table for flat & ribbon cables

FTZ New Products COOL SEAL CLEAR SEAL EXTREME SEAL CORRECT CONNECT MPC CRIMP TOOL SEAMLESS COPPER LUGS. Qua lity Sta tement

ÖLFLEX 409 P. Heavy duty control cable with PUR jacket

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

Shielded Fire Alarm Cables

TIGER BRAND MINING CABLES

FIT Sleeving for Rugged Applications

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

Resist water & condensation Resist salt & other contaminants Resist wire pull out & current leakage

AEE. Canada. Australia

LITZ WIRE 1

WIRE & CABLE. 55 Wire High performance wire and cable

SECTION BUILDING WIRE AND CABLE

SERV-RITE Wire. Thermocouple and Extension Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

ADVANCED FLAT CABLE SOLUTIONS

TECHNICAL DATA TECHNICAL INFORMATION GUIDE TECHNICAL ENGINEERING AND DESIGN ASSISTANCE

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

FLEXIBLE MULTI CORE CABLES

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

A. Product Description: Stranded conductor insulated wire.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Industrial Automation & Control Cables

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

LGH High Voltage Connectors

High Performance Wire and Cable SPEC 55. Product Facts. by hot stamp, ink jet or laser, and can be potted without pre-etching.

ABOUT US ABOUT US 1 CRANE CABLES

FILE // 4 GAUGE TERMINAL CONNECTORS DOCUMENT

LTE high-performance coaxial cables (RG replacement)

Color-Keyed. Compression Connector System. Table of Contents

Addison Medium Voltage Cables

American Electrical Institute

Servo Cable Selection

SEALED CRIMP CONNECTORSTM

100 Ft. lengths of Primary Wire come on spools. Gauge: 8 AWG 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG

Transcription:

1

Table Of Contents Automotive Wire Building Wire Terminals Cont. Battery Cable SGT 3 Romex 25 Quick-Splice Disconnectors 54 Battery Cable SGX STX 3 TFFN/TFN 25 T-Taps 54 Jumper Cable 3 THHN 26 Push-On 55-56 Brake Cable / Duplex 4 XHHW XHHW-2 27 Rings 57, 58 TXL 4 Control Cable Battery Connectors 59 GXL 5 DLO 28 Spades SXL 5 European Flexible Control Cable 29,30 Block Spades (Flanged) 60 Speaker Wire 5 Flat Festoon 31 Snap Spades 60 GPT 6 G/GGC 32 Spades (Forks) 61 TWP 6 Pendant 33 Step Down Connectors 61 Trailer Cable 7 SEOOW 34 Square Adhesive-back Cable Tie Mounts 62 Welding Cable 8 SJEOOW 35 Terminal Blocks 62 Welding Cable UL 8 Stagelighting Entertainment 35 U Telecomm Connectors 63 J-1939 Automotive Data and Communication Cable 9 SJOOW 36 Wire Nuts Lead Wire SJTOOW 37 All Plastic Wire Connectors 64 UL 1007 10 SOOW 37 Spring Loaded Wire Connectors 64 UL 1056 10 SPT 37 Winged Wire Connectors 65 UL 1659 11 STOW 38 Cable Ties UL 1015 11, 12 Thermostat Cable 39 Marker / Identification Cable Ties 66 UL 1232 13 Tray Cable 40-42 Releasable Cable Ties 66 10086 14 W 43-44 Regular Cable Ties 67 UL 3173 14 Electronic Wire Screw Mount Cable Ties 68 Coaxial, Security, Video, UL 3257 14 Plenum, and Non-Plenum 45 Tubing UL 3239 15 Voice, Data, and Premise Wire 45,46 Shrinkable Tubing 69-80 UL 1422 15 Telephone Silver Satin 47 Non-Shrinkable Tubing 81-95 UL 3321 16 Bonded Wire Sleeving MGS 16 Bonded Wire 48 Sleeving 96 E 17 Uninsulated Wire Loom EE 18 Uninsulated Wire 48-49 Loom 97-98 EPDM 19 Terminals Accessories Military Wire 20,21 B Telecomm Connectors 50 Tapes 99 SIS 21 Bullets 50 Fuses and Fuse Holders 100-102 SR 22 Butt Splice 51 Tools 103 SRML 22 Closed End Crimp Connectors 52 Trailer Parts 104-105 TGGS 23 Cradle Tie Mounts 52 Services Marine Wire Flags 53 Assemblies, Bonding, Dyeing, Printing, Striping, Battery Cables 106 Boat Cable 24 Hooks 53 Speciality Products GPT M 24 Push-in Wire Connectors 54 Speciality Products 107 2

About Us ADI, Inc., is a value-added electric wire and cable distributor based in Chanute, Kansas, with customers world-wide. Because we are so willing and able to help customers with their specific requirements, we have enjoyed relationships with customers who have trusted us for many years. We personalize service, customize solutions, and guarantee quality on a wide variety of products. We carry a full line of products for the automotive, marine, agricultural, truck, appliance, building and recreational vehicle industries as well as special orders. Our company has specialty machines for the bonding of wires for multi-colored ribbon cable type products, and stripping machines for both parallel and spiral stripes. We use these machines for multiple wire types and sizes as requested by our customers. We have a battery cable assembly and cut and strip department to build custom products to your specifications. ADI Inc. has a policy that our customer's are #1. We provide custom sizes, packaging and solutions to provide products the way you want them. A quality assurance program is also in place to insure that problems are corrected as soon as they are found. We strive to earn your trust as well as your business. ADI has been family owned and operated since Merrill Cunningham founded it in 1990. His wife, Wendy, works as Office Manager, while his son, Scott, leads Production and Sales. Scott s wife, Staci, runs Accounting. You can be sure that ADI offers personal care. We can even deliver to our customers within a 150-mile radius. We accept MasterCard, Visa, and Discover. ADI, Inc., is a certified respooler with the Underwriters Laboratories number E146138, undergoing regular inspections by UL Representatives. What can ADI do for me? Cut to Length Quantities Custom Bonded Wire Printing Custom Striping Family Service Custom Packaging Personalized Labeling and Part Numbers Custom Stocking Capabilities Bulk Wire and Small Quantities Quality Guarantee Custom Battery Cable & Wire Assemblies Personalized Service Willing to work with customers Problem Solving At A.D.I we want to do what it takes to earn your business and your trust. We have built long lasting relationships with many of our customers, some lasting over 20 years, and we want to continue that relationship long into the future. 3

Battery Cable SGT Polyvinylchloride (PVC) (-40C to 80C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 6 133/27 Bare.060.301 106 4 133/25 Bare.065.356 181 2 133/23 Bare.065.420 236 1 259/25 Bare.065.458 305 1/0 1026/30 Bare.065.515 363 2/0 1254/30 Bare.065.570 454 3/0 1615/30 Bare.078.646 581 4/0 2052/30 Bare.078.706 738 Used for automotive starters or battery grounds. Meets SAE J-1127 and RVIA specifications. We can stripe and print to meet your specifications. Battery Cable SGX STX Cross-linked Polyethylene (XLP) (-40 to 125C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 6 STX 133/27 Bare.043.282 102 4 STX 133/.0171 Bare.044.331 144 6 133/27 Bare.060.315 112 4 133/.0171 Bare.065.374 159 2 133/.0220 Bare.065.428 241 1 259/25 Bare.065.460 310 1/0 1026/30 Bare.065.523 369 2/0 1254/30 Bare.065.578 461 3/0 1615/30 Bare.078.654 590 4/0 2052/30 Bare.078.714 745 Used for automotive starters or battery grounds where resistance to abrasion, heat and aging is needed. Meets SAE J-1127 and RVIA specifications. We can stripe and print to meet your specifications. Jumper Cable Flat Parallel Unjacketed PVC (80C) A U O T M O T I V E W I R E Wire Gauge (AWG) No. of Conductors Conductor Stranding Approximate Lbs. per 1000ft 8 2 168/.010 Bare 182 6 2 133/.0139 Bare 226 4 2 133/.0170 Bare 355 2 2 665/.010 Bare 486 4

Brake Cable / Duplex Flat Jacketed Polyvinylchloride (PVC) Automotive Brake Cable (105C) Wire Gauge (AWG) No. of Conductors Approximate Lbs. Conductor Stranding Insulation Thickness per 1000ft 18 2 16/30 Bare.023 33 16 2 19/29 Bare.023 36 16 3 19/29 Bare.023 66 16 4 19/29 Bare.023 77 14 2 19/27 Bare.023 40 14 3 19/27 Bare.023 75 14 4 19/27 Bare.023 92 12 2 19/25 Bare.026 71 12 3 19/25 Bare.026 99 12 4 19/25 Bare.026 140 10 2 19/23 Bare.031 113 10 3 19/23 Bare.031 144 10 4 19/23 Bare.031 185 8 2 19/21 Bare.037 180 Used in electric brake, and many automotive, truck or trailer applications. 2 conductor is black, white. 3 conductor is black, green, white. 4 conductor is black, red, green, white. TXL Automotive Extra Thin Wall Cross-linked Polyethylene (XLP) Wire SAE J-1128 (-40C to 125C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 7/30 Bare.016.062 3 20 7/28 Bare.016.070 5 18 19/.0092 Bare.016.078 7 16 19/29 Bare.016.089 9 14 19/27 Bare.016.102 14 12 19/25 Bare.018.127 22 10 19/23 Bare.020.155 35 8 19/21 Bare.020.191 55 Used in automotive applications where higher heat resistance, small diameter and minimal weight is required. Meets Ford ESB-M1L 123A and Chrysler MS-8288 specifications. SAE J-1560 was replaced by SAE J-1128 in 1995. We can stripe and print to meet your specifications. 5

GXL Automotive Thin Wall Cross-linked Polyethylene (XLP) Wire SAE J-1128 (-40C to 125C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 20 7/28 Bare.023.086 6 18 19/.0092 Bare or 16/30 Bare.023.094 8 16 19/29 Bare.023.105 12 14 19/27 Bare.023.119 16 12 19/25 Bare.026.145 25 10 19/23 Bare.031.181 39 8 19/21 Bare.037.216 60 Used in automotive applications where higher heat resistance and small diameter is required. Meets Ford ESB -M1L 85B and Chrysler MS-8900 specifications. We can stripe and print to meet your specifications. SXL Automotive Cross-linked Polyethylene (XLP) Wire SAE J-1128 (-40C to 125C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 20 7/28 Bare.029.096 7 18 16/30 Bare.030.110 10 16 19/29 Bare.032.120 13 14 19/27 Bare.035.139 19 12 19/25 Bare.037.162 27 10 19/23 Bare.041.192 41 8 19/21 Bare.043.234 64 Used in automotive applications where higher heat resistance is required. Meets Ford ESB-M1L 85B and Chrysler MS-5919 specifications. We can stripe and print to meet your specifications. Speaker Wire Clear Polyvinylchloride (PVC) (60C) Wire Gauge (AWG) No. of Conductors Approximate Lbs. Conductor Stranding Insulation Thickness per 1000ft 24 2 7/32.016 8 22 2 7/30.020 10 20 2 10/30.020 12 18 2 16/30.023 19 16 2 26/30.023 25 14 2 41/30.023 35 12 2 65/30.023 52 Used for music systems, radios, public address systems and other low voltage applications. One bare and one tinned copper conductor. 6

GPT Automotive Lead-Free Polyvinylchloride (PVC) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 7/30 Bare.023.077 4 20 7/28 Bare.023.084 6 18 16/30 Bare.023.092 8 16 19/29 Bare.023.103 11 14 19/27 Bare.023.117 16 12 19/25 Bare.026.142 24 10 19/23 Bare.031.177 41 8 19/21 Bare.037.222 61 Wire SAE J-1128 (-40C to 80C) (105C also available) Meets Ford ESB-M1L 56A 80C, Ford ESB-M1L 58A 105C, and Chrysler MS-3450 specifications. GPT22 meets Ford ESB-M1L 56A only because Ford ESB-M1L 58A requires.010 insulation instead of normal.023. Used in automotive applications for general circuit wiring and automotive or marine applications where 105C is required. We can stripe, print, and bond to meet your specifications. TWP Automotive Lead Free Thin Wall Polyvinylchloride (PVC) Wire SAE J-1128 (-40C to 105C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 7/30 Bare.016.062 3 20 7/28 Bare.016.070 5 18 19/.0092 Bare.016.078 7 16 19/29 Bare.016.089 9 14 19/27 Bare.016.103 14 12 19/25 Bare.018.126 22 10 19/23 Bare.021.155 35 Used in automotive applications where small diameter and minimal weight is required. Meets Ford ESB-M1L 120A and Chrysler MS-7889 specifications. SAE J-1560 was replaced by SAE J-1128 in 1995. We can stripe, print, and bond to meet your specifications. 7

Trailer Cable PVC (-50C to 80C) Wire Gauge (AWG) No. of Conductors Conductor Colors Conductor Stranding Insulation Thickness Wire Thickness 16 4 black, white, brown, red 19/29 bare.023.375 120 16 4 red, green, brown, yellow 19/29 bare.023.375 120 16 6 black, white, brown, green, red, yellow 19/29 bare.023.440 150 16 6 black, red, brown, green, blue, yellow 19/29 bare.023.440 150 14 4 black, white, brown, red 19/27 bare.023.420 150 14 4 red, green, brown, yellow 19/27 bare.023.420 150 14 6 black, white, brown, green, red, yellow 19/27 bare.023.490 190 14 6 black, red, brown, green, blue, yellow 19/27 bare.023.490 190 14 7 black, white, brown, green, red, yellow, blue 19/27 bare.023.535 220 12 4 black, white, brown, red 19/25 bare.026.510 250 12 6 black, white, brown, green, red, yellow 19/25 bare.026.560 320 Approximate Lbs. per 1000ft 14/4 12/1 10/2 Trailer Cable Wire Gauge (AWG) 14 4 No. of Conductors Conductor Colors brown, yellow, green, red Conductor Stranding Insulation Thickness Wire Thickness 19/27 bare.023.560 270 12 1 blue 19/25 bare.026.560 270 10 2 black, white 19/23 bare.031.560 270 Approximate Lbs. per 1000ft 12/6 10/1 Trailer Cable No. of Conductorinness per 1000ft Conductor Strand- Insulation Thick- Approximate Lbs. Wire Gauge (AWG) Conductor Colors Wire Thickness 12 6 blue, brown, green, red, yellow, black 19/25 bare.026.600 350 10 1 white 19/23 bare.031.600 350 12/4 10/2 8/1 Trailer Cable Wire Gauge No. of Conductors Conductor Colors (AWG) yellow, black, 12 4 brown, green Conductor Stranding Insulation Thickness Wire Thickness 65/30 Bare.026.710 420 10 2 blue, red 105/30 Bare.031.710 420 8 1 white 168/30 Bare.037.710 420 Approximate Lbs. per 1000ft Used for automotive trailers, trucks, or applications with resistance to weather, oil and grease. Trailer cable inner conductors are stranded copper and color-coded for i.d. purposes with a PVC jacket. 8

Welding Cable Ethylene-propylene-diene monomer (EPDM) Class K (30 AWG) (600V) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 6 266/30 Bare.060.320 116 4 392/30 Bare.060.375 163 3 525/30 Bare.060.428 215 2 644/30 Bare.060.440 252 1 784/30 Bare.080.515 321 1/0 1026/30 Bare.080.550 389 2/0 1254/30 Bare.080.590 474 3/0 1615/30 Bare.080.660 601 4/0 2052/30 Bare.080.725 763 250 2451/30 Bare.125.875 1029 350 3458/30 Bare.125.998 1372 500 4921/30 Bare.125 1.150 1882 Used for welding equipment, portable lighting, automotive starters or battery ground. High tear strength jacket with excellent resistance to abrasion and impact. Weather, sunlight, and ozone resistant jacket. Superior low temperature flexibility with good flame resistance. Welding Cable UL Chlorinated Polyethylene Rubber (CPE) Class K (30 AWG) (-50 to 90C) (600V) Approximate Lbs. per Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness 1000ft 6 266/30 Bare.080.364 135 4 420/30 Bare.080.414 192 2 665/30 Bare.080.482 282 1 833/30 Bare.080.522 332 1/0 1064/30 Bare.090.582 433 2/0 1330/30 Bare.090.637 528 4/0 2109/30 Bare.090.747 795 Used for welding equipment, and power supply applications. High tear strength jacket with excellent resistance to abrasion and impact. Ozone, oil, acid, chemical, grease, and sunlight resistant jacket. Superior low temperature flexibility. 9

J-1939 Automotive Data and Communication Cable Irradiated Cross-linked Polyolefin Controlled Impedance Data-bus Cable Unshielded Single Jacket, Black (20AWG: -40C to 125C) (J-1939/15) Wire Gauge No. of Conductors Stranding ness Lbs. per 1000ft Conductor Insulation Thick- Approximate Wire Thickness (AWG) 20 2 7/28 Bare.022.209 20 18 2 19/.23mm Bare.025.252 22 Shielded Aluminum/Polyester with Tin Plated Copper Drain Wire, Double Jacket, Black (-40C to 150C) (J- 1939/11) Wire Gauge No. of Conductors Stranding Thickness per 1000ft Conductor Insulation Approximate Lbs. Wire Thickness (AWG) 20 2 19/.18mm Bare.030.335 51 18 2 19/.23mm Bare.040.400 61 Irradiated Cross-linked Foam Polyolefin Controlled Impedance Data-bus Cable Shielded Aluminum/Polyester with Tin Plated Copper Drain Wire, Single Jacket, Black (-40C to 125C) (J- 1939/11) Wire Gauge No. of Conductors Stranding ness Lbs. per 1000ft Conductor Insulation Thick- Approximate Wire Thickness (AWG) 20 2 19/.18mm Bare.036.291 38 18 2 19/.23mm Bare.046.352 45 Foam Polyethylene/PVC Controlled Impedance Data-bus Cable (90C to 105C) Shielded Aluminum/Polyester with Tin Plated Copper Drain Wire, Grey Jacket Wire Gauge No. of Conductors Stranding ness Lbs. per 1000ft Conductor Insulation Thick- Approximate Wire Thickness (AWG) 20 2 7/28 Bare.032.243 28 Used in electronic truck and bus, with drive train, safety and trailer functions. Supports the multiplexing protocol while meeting all physical and mechanical requirements. Resistant to harsh chemicals and fluids in the power train. Designed for protection against interference including EMI and RFI. 10

UL 1007 1007/1569/Mil-W-16878/2 Type C PVC Hookup Wire (VW-1) UL 1007 80C/300V CSA TR64 90C/300V UL1569 105C/300V CSA AWM 1 A/B 105C/300V FT 1 Mil-W-16878/2 Type C 105C/1000V L E A D W I R E Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 26 7/34 Tinned.015.051 2 24 7/32 Tinned.015.057 2.5 24 19/36 Tinned.015.057 2.5 24 Solid Tinned.015.052 2.5 24 7/32 Topcoat.015.057 2.5 22 7/30 Tinned.015.062 3.3 22 19/34 Tinned.015.062 3.7 22 Solid Tinned.015.062 3 22 7/30 Topcoat.015.062 4 20 10/30 Tinned.015.070 4.7 20 19/32 Tinned.015.073 5 20 Solid Tinned.015.067 4.7 20 10/30 Topcoat.015.067 4.7 18 16/30 Tinned.015.079 7 18 19/.0092 Tinned.015.079 7 18 Solid Tinned.015.073 6.5 18 16/30 Topcoat.015.079 7 16 26/30 Tinned.015.095 10.5 16 Solid Tinned.015.091 10 16 26/30 Topcoat.015.095 10 14 41/30 Tinned.015.110 16 12 65/30 Tinned.015.131 24 10 105/30 Tinned.015.145 36 Used in internal wiring of appliances and electronic equipment. Overcoat, topcoat, and prebond stranding available. We can stripe and print for your needs. UL 1056 1275/1056, 1276/1060 PVC Heavy Wall Lead, Hookup Wire and Refrigeration Wire (105C) VW-1 and Moisture Resistant) (600 Volts) (UL and CSA) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 18 16/30 Bare.063.174 18.4 16 26/30 Bare.063.186 23 14 41/30 Bare.078.234 36.3 12 65/30 Bare.078.252 46.2 10 105/30 Bare.078.280 63.3 Used in appliances, equipment, ballasts, controls, electronic circuits, hookups, motors, panels, switchboards, transformers, refrigeration equipment and room cooler units. We can stripe and print for your needs. 11

UL 1015 1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Bare Copper) PVC Machine Tool Wire/ Thermoplastic Equipment Wire (90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) (1032 1000 Volts) Marine approvals for 16-8 AWG meets UL Standard 1426 BC-5W2, SAE J378, USCG, ABYC, and NMMA Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 7/30 Bare.03125.091 5 22 Solid Bare.03125.088 5 20 10/30 Bare.03125.099 7 20 Solid Bare.03125.096 7 18 16/30 Bare.03125.106 9 18 Solid Bare.03125.102 9 16 26/30 Bare.03125.117 13 16 Solid Bare.03125.112 13 14 19/.0147 Bare.03125.132 18 14 41/30 Bare.03125.132 18 14 Solid Bare.03125.124 18 12 19/.0185 Bare.03125.151 27 12 65/30 Bare.03125.151 27 12 Solid Bare.03125.145 27 10 19/.0234 Bare.03125.175 40 10 105/30 Bare.03125.175 41 10 Solid Bare.03125.165 41 8 19/.0295 Bare.047.242 68 8 133/29 Bare.048.252 67 Used in internal wiring of appliances, control cabinets, and for machine tools. Overcoat, topcoat, and prebond stranding available. We can stripe and print for your needs. UL 1659 1659 Polytetra Fluoroethylene (PTFE) (600 Volts) (250C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 19/.0063 NPC.020.070 5.70 20 19/.0080 NPC.020.078 7.65 18 19/.0100 NPC.020.087 10.5 16 19/.0117 NPC.020.096 13.4 14 19/.0147 NPC.020.109 18.8 12 19/.0185 NPC.020.128 27.6 10 37/.0157 NPC.020.154 39.00 Used in internal wiring of appliances and electronic equipment. PTFE lead wires have a low coefficient of friction. Also resists hot soldering irons, is self-extinguishing, non-flammable, chemical resistant, and suitable for immersion in gasoline or gas vapor. Conductor is nickel plated copper. 12

UL 1015 (Tinned Copper) 1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Tinned Copper) PVC Machine Tool Wire/Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW) (90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) (1032 1000 Volts) Marine approvals for 16-8 AWG meets UL Standard 1426 BC-5W2, SAE, J378, USCG, ABYC, and NMMA Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 26 7/34 Tinned.03125.081 4 24 7/32Tinned.03125.087 4.7 22 7/30 Tinned.03125.091 5 20 10/30 Tinned.03125.099 7 20 10/30 Topcoat.03125.99 7 18 Solid Tinned.03125.102 9 18 16/30 Tinned.03125.106 9 18 16/30 Topcoat.03125.106 10 16 26/30 Tinned.03125.117 13 16 26/30 Topcoat.03125.117 13 14 41/30 Tinned.03125.132 18 12 65/30 Tinned.03125.151 27 10 105/30 Tinned.03125.175 41 8 133/29 Tinned.048.252 68 Used in appliances, controls, ballasts, electronic circuits, hookups, motors, switchboards, and transformers. 24 and 26 AWG tinned is not MTW rated and not marine approved We can stripe and print for your needs. UL 1015 (Tinned Copper) Large Gauge 1015/1011/1028/1032/1230/1231/1335/1344/MTW/TEW (Tinned Copper) PVC Machine Tool Wire/ Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW) Extra Flexible and Standard Large MTW/ TEW (90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 6 266/30 Tinned.060.322 114 4 420/30 Tinned.060.372 167 2 665/30 Tinned.060.437 252 1 833/30 Tinned.080.521 332 1/0 1064/30 Tinned.080.561 402 2/0 1330/30 Tinned.080.616 495 3/0 1672/30 Tinned.080.666 612 4/0 2109/30 Tinned.080.726 758 250 MCM 2499/30 Tinned.100.887 978 350 MCM 3458/30 Tinned.100 1.045 1350 400 MCM 4123/30 Tinned.098 1.16 1475 500 MCM 5054/30 Tinned.130 1.275 1968 750 MCM 7581/30 Tinned.115 1.38 2853 Used in internal wiring of appliances, control cabinets, and for machine tools. #6 4/0 flexible MTW/TEW includes THHW, boat cable BC-5W2, SAE J1127 Type SGT, UL 10269 1000 Volts 1/0-750 MCM is Cable Tray rated. We can stripe and print for your needs. 13

UL 1232 1232/1283/1284/1338/1339/1340/1346/10269/MTW/TEW (Bare Copper) PVC Machine Tool Wire/ Thermoplastic Equipment Wire/Thermoplastic Equipment Wire (TEW) Extra Flexible and Standard Large MTW/ TEW (90C MTW) (UL and CSA 105C) (VW-1 and Moisture Resistant) (600 Volts) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 6 19/.0372 Bare.060.306 110 6 266/30 Bare.060.355 118 4 19/.0469 Bare.060.355 166 4 420/30 Bare.060.367 164 2 19/.0591 Bare.060.415 250 2 665/30 Bare.060.432 251 1 833/30 Bare.080.521 332 1/0 1064/30 Bare.080.561 402 2/0 1330/30 Bare.080.616 492 3/0 1672/30 Bare.080.666 612 4/0 2109/30 Bare.080.726 758 250 MCM 2451/30 Bare.095.835 956 350 MCM 3458/30 Bare.100 1.045 1350 400 MCM 4123/30 Bare.98 1.16 1475 500 MCM 5054/30 Bare.130 1.275 1968 750 MCM 7581/30 Bare.115 1.38 2853 Used in internal wiring of appliances, control cabinets, and for machine tools. #6 4/0 flexible MTW/TEW includes THHW, boat cable BC-5W2, SAE J1127 Type SGT, UL 10269 1000 Volts 1/0-750 MCM is Cable Tray rated. We can stripe and print for your needs. 10086 10086/CSA, Class1, Group A/B Tefzel-Extruded ETFE 200C/600V Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 20 7/28BC.010.058 5 18 7/.0152BC.010.066 6 16 7/.0192BC.010.078 10 14 7/.0242BC.010.092 15 12 19/.0185BC.015.119 23 Used in internal wiring of electrical equipment and UL classified appliance wiring service up to 200C. Conductor also available in tin-plated copper or silver-plated copper. We can stripe and print for your needs. 14

UL 3173 3173/3195/3196 Chemically Cross-linked Polyethylene (XLPE) (600 Volts) (UL and CSA) (125C) Approximate Lbs. per Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness 1000ft 22 7/30 Tinned.030.090 5 20 10/30 Tinned.030.103 7.5 18 16/30 Tinned.030.110 10 16 26/30 Tinned.030.121 13 14 41/30 Tinned.030.138 19 12 65/30 Tinned.030.157 28 10 105/30 Tinned.030.187 43 8 133/29 Tinned.045.261 69 6 133/27 Tinned.060.338 115 4 133/25 Tinned.060.392 174 Used for appliances, coil leads, switchboard panels, transformers, motor leads and power operated dispensing units. 22 AWG, 20 AWG, 18 AWG and 16 AWG are also printed with SWITCHBOARD WIRE for SIS applications. 14 AWG through 4 AWG are also printed with SIS for non VW-1 SIS applications. We can stripe and print for your needs. UL 3257 3257 Braidless Silicone Rubber High Voltage, High Temp Appliance Lead Wire 10 KVAC, 25 KVDC (250C) Approximate Lbs. per Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness 1000ft 20 7 NPC.078.194 19 20 7 NPC.112.262 33 18 16 NPC.078.200 22 16 26 NPC.078.2125 27 16 26 NPC.111.278 41 14 41 NPC.078.228 34 12 65 NPC.078.249 44 Used in high voltage and/or high temp applications such as gas appliance ignitor systems, oil burner ignition circuits, gas fired infra-red heaters and furnaces where protected from repeated flexing, abrasion and physical damage. 15

UL 3239 3239/10475 Braidless Silicone Rubber High Voltage, High Temp Appliance Lead Wire 15 KVDC, 25 KVDC, 40 KDVC (150C) (VW-1) Wire Gauge Approximate Lbs. Conductor Stranding Insulation Thickness Wire Thickness D.C. Voltage (AWG) per 1000ft 22 7/30 Tinned.045.115 15KV 8 22 7/30 Tinned.062.149 25KV 11 22 7/30 Tinned.097.219 40KV 21 20 7/28 Tinned.045.128 15KV 10 20 7/28 Tinned.062.162 25KV 14 20 7/28 Tinned.097.232 40KV 25 18 16/30 Tinned.045.135 15KV 12 18 16/30 Tinned.062.169 25KV 16 18 16/30 Tinned.097.239 40KV 28 16 26/30 Tinned.045.148 15KV 16 16 26/30 Tinned.062.182 25KV 21 16 26/30 Tinned.097.252 40KV 33 14 41/30 Tinned.045.164 15KV 22 14 41/30 Tinned.062.198 25KV 27 14 41/30 Tinned.097.268 40KV 40 12 65/30 Tinned.045.181 15KV 31 12 65/30 Tinned.062.215 25KV 36 12 65/30 Tinned.097.285 40KV 50 10 105/30 Tinned.045.214 15KV 44 10 105/30 Tinned.062.248 25KV 51 10 105/30 Tinned.097.318 40KV 67 8 133/29 Tinned.068.301 25KV 80 6 133/27 Tinned.068.342 25KV 115 4 133/25 Tinned.068.401 25KV 166 2 259/26 Tinned.065.465 25KV 259 Used in stoves, heaters, furnaces, dryers, motors, therapeutic devices, signs, lighting fixtures, aircraft, submarines and special electronic devices where high temps are incurred. UL 1422 1422/1423 Kynar Insulated Wire Wrap 105C, No Voltage Rating Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 30 Solid SPC.004.0195.47 28 Solid SPC.005.0240.73 26 Solid SPC.006.0270 1.05 Used as appliance wiring material suitable for back panel areas of electronic computers and business machines here not subject to movement or mechanical damage. SPC is silver plated copper. 16

UL 3321 3321/3505 Chemically Cross-linked Polyethylene Insulation (XLP) (150C) (600 Volts) (CSA FT 1) Approximate Lbs. per Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness 1000ft 20 10/30 Tinned.030.103 7 8 16/30 Tinned.030.110 10 16 26/30 Tinned.030.121 13 14 41/30 Tinned.030.138 19 12 65/30 Tinned.030.157 27 10 105/30 Tinned.030 187 42 8 133/29 Tinned.045.257 66 6 133/27 Tinned.060.335 113 Used in appliances, transformers, electrical and gas heating, motors, ballast, lighting, hairdressing and cooking equipment. We can stripe and print for your needs. MGS MGS/5359 (MGS SLIPSTRIP R replaces MGT) Apparatus Wire (450C) (600 Volts) (UL VW-1 and CSA FT 1) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 22 7/30 NPC.016.077 4.78 20 10/30 NPC.016.083 6.27 18 16/30 NPC.016.092 8.52 16 26/30 NPC.016.104 12.2 14 41/30 NPC.016.119 17.9 12 65/30 NPC.016.140 26.7 10 105/30 NPC.020.185 41.9 8 133/29 NPC.020.227 65.8 6 133/27 NPC.020.268 98.7 4 133/25 NPC.020.321 151 2 133/23 NPC.025.415 241 Used for wiring of domestic and commercial ovens and similar high temp equipment with operating temperatures up to 450C. Also used for electric heaters, blast furnaces, coke ovens, basic oxygen furnaces and cement kilns. Flexible, stranded, 27% nickel-plated conductor (NPC) insulated with a spiral wrapped composite mica tape jacketed with an overall fiberglass braid impregnated with a silicone saturator. Asbestos and halogen free. MGS SLIPSTRIP R gives you the advantage of a smaller diameter due to the reduced wall yet still gives you the same temperature and voltage of the MGT it replaces. MGS is superior to MGT in cutting and stripping. 17

E E/1213/1371 Type E Teflon (-60C to 200C) (600 Volts) UL1213 (-60C to 105C) (Voltage na) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 30 Solid SPC.010.030 0.90 30 7/38 SPC.010.032 1.00 28 Solid SPC.010.033 1.12 28 7/36 SPC.010.035 1.23 28 19/40 SPC.010.035 1.25 26 Solid SPC.010.036 1.55 26 7/34 SPC.010.039 1.74 26 19/38 SPC.010.039 1.78 24 Solid SPC.010.041 2.12 24 7/32 SPC.010.044 2.35 24 19/36 SPC.010.045 2.46 22 Solid SPC.010.045 2.92 22 7/30 SPC.010.048 3.33 22 19/34 SPC.010.051 3.43 20 Solid SPC.010.054 4.19 20 7/28 SPC.010.057 4.98 20 19/32 SPC.010.058 5.10 18 7/26 SPC.010.069 7.70 18 19/30 SPC.010.069 7.75 16 19/29 SPC.010.080 10.00 14 1927 SPC.013.095 16.00 12 19/25 SPC.013.114 24.00 10 37/26 SPC.013.134 34.00 Used in internal wiring of electrical equipment where exposed to mechanical abuse for high temperature applications in computers, business machines, and meters. SPC is silver plated copper conductor. UL requires slightly different strand size on 16AWG and larger. No imprint required for Military or UL. UL requires UL tags. 18AWG and smaller is UL tagged. 16AWG and larger is MIL-SPEC only. UL/CSA available on special order. CSA material rated 150C, 150 volts, and type AWM. Meets NEMA HP3 and is made to old MIL- W-1878 specification. 18

EE EE/1180 Type EE Teflon (-60C to 200C) (600 Volts) UL1180 (-60C to 200C) (300 Volts) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 28 7/36 SPC.015.045 1.90 26 Solid SPC.015.047 2.18 26 7/34 SPC.015.049 2.40 26 19/38 SPC.015.049 2.48 24 7/32 SPC.015.054 3.25 24 19/36 SPC.015.054 3.70 22 7/30 SPC.015.060 4.19 22 19/34 SPC.015.061 4.32 20 7/28 SPC.015.068 5.85 20 19/32 SPC.015.069 6.10 18 7/26 SPC.015.079 8.35 18 19/30 SPC.015.080 8.52 16 19/29 SPC.015.090 11.00 14 19/27 SPC.017.106 17.00 12 19/25 SPC.017.125 25.00 10 37/26 SPC.017.145 37.00 8 133/29 SPC.020.210 64.00 6 133/27 SPC.030.263 122.00 Used in internal wiring of electrical equipment where exposed to mechanical abuse for high temperature applications in computers, business machines, and meters. SPC is silver plated copper conductor. UL requires slightly different strand size on 16AWG and larger. No imprint required for Military or UL. UL requires UL tags. 18AWG and smaller is UL tagged. 16AWG and larger is MIL-SPEC only. UL/CSA available on special order. CSA material rated 150C, 150 volts, and type AWM. Meets NEMA HP3 and is made to old MIL- W-1878 specification. 19

EPDM EPDM/3340/3374 Ethylene-propylene-diene Monomor Appliance and Motor Lead Wire (125C/Flexing, 150C/ Non-Flexing) (600 Volts) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 16/30 Tinned.045.140 5 16 26/30 Tinned.045.153 8 14 41/30 Tinned.045.168 13 12 65/30 Tinned.045.187 20 10 105/30 Tinned.045.216 32 8 84/27 Tinned.060.297 52 6 133/27 Tinned.060.345 82 4 133/25 Tinned.060.392 133 2 665/30 Tinned.060.465 210 1 833/30 Tinned.080.520 260 1/0 1064/30 Tinned.080.550 335 2/0 1330/30 Tinned.080.620 420 3/0 1672/30 Tinned.080.694 518 4/0 2109/30 Tinned.080.720 665 Used as appliance wire and as lead wire for motors, transformers, coils, ballasts or solenoids. EPDM/3499 High Voltage Ethylene-propylene-diene Monomor High Voltage Appliance and Motor Lead Wire (150C) (7500 Volts) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 8 84/27 Tinned.125.431 117 6 84/25 Tinned.125.473 157 4 133/25 Tinned.125.526 219 2 665/30 Tinned.125.560 296 1/0 1064/30 Tinned.125.635 434 3/0 1330/30 Tinned.125.690 529.5 3/0 1672/30 Tinned.125.740 646 4/0 2109/30 Tinned.125.800 795 EPDM has great dielectric strength, abrasion resistance, low temp flexibility and stripping ability. 20

Military Wire B, C, D Military Wire MIL-W-16878/1 Type B (105C) (600 Volts) Wire Gauge (AWG) Approximate Lbs. per Conductor Stranding Insulation Thickness Wire Thickness NO. 1000ft 30 7/38 Tinned.010.031.085 28 7/36Tinned.010.035 1.08 26 7/34 Tinned.010.039 1.46 24 7/32 Tinned.010.044 2.18 24 19/36 Tinned.010.044 2.18 22 7/30 Tinned.010.051 2.99 22 19/34 Tinned.010.051 3.19 20 7/28 Tinned.010.058 4.43 20 19/32 Tinned.010.058 4.72 18 7/26 Tinned.010.070 6.68 18 19/30 Tinned.010.070 7.03 16 19/29 Tinned.010.077 8.89 14 19/27 Tinned.010.090 13.54 MIL-W-16878/2 Type C (105C) (1000 Volts) Wire Gauge (AWG) Approximate Lbs. per Conductor Stranding Insulation Thickness Wire Thickness NO. 1000ft 28 7/36 Tinned.017.047 1.60 26 7/34Tinned.017.051 2.00 24 7/32 Tinned.017.058 2.77 24 19/36 Tinned.017.058 2.88 22 7/30 Tinned.017.063 3.65 22 19/34 Tinned.017.063 3.84 20 7/28 Tinned.017.072 5.17 20 19/32 Tinned.017.072 5.17 18 7/26 Tinned.017.082 7.54 18 19/30 Tinned.017.082 8.04 16 19/29 Tinned.017.092 9.86 14 19/27 Tinned.017.105 14.65 12 19/25 Tinned.017.124 22.51 MIL-W-16878/3 Type D (105C) (3000 Volts) Wire Gauge (AWG) Approximate Lbs. per Conductor Stranding Insulation Thickness Wire Thickness NO. 1000ft 24 7/32 Tinned.031.086 4.85 22 7/30 Tinned.031.093 5.91 20 7/28 Tinned.031.100 7.63 18 7/26 Tinned.031.110 10.29 16 19/29 Tinned.031.120 12.87 14 19/27 Tinned.031.134 18.05 12 19/25 Tinned.037.160 27.27 10 37/26 Tinned.037.182 39.8 8 133/29 Tinned.037.245 68.7 6 133/27 Tinned.037.295 102.7 21

Military Wire Continued MIL-W-76D Type MW Medium Wall PVC MIL-Spec Wire (1000 V) (-40C to 80C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 24 7/32 Tinned 0.016 0.057 2.63 22 7/30 Tinned 0.016 0.062 3.34 20 10/30 Tinned 0.016 0.070 4.69 18 16/30 Tinned 0.016 0.079 6.82 16 26/30 Tinned 0.016 0.091 10.30 14 41/30 Tinned 0.016 0.110 15.53 12 65/30 Tinned 0.016 0.131 23.90 Used for wiring of electronic equipment. MIL-W-76D superseded MIL-W-76B in Sept. 1992. We can stripe and print for your needs. 1061/MIL-W-16878/1/Type B Semi-rigid PVC (80C) (300 Volts) (UL and CSA) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 26 7/34 Tinned.009.038 1.5 24 7/32 Tinned.009.045 2.0 22 7/30 Tinned.009.051 3.0 20 10/30 Tinned.009.058 4.0 18 16/30 Tinned.009.067 6.5 16 26/30 Tinned.009.078 8.5 Used in internal wiring of appliances and electronic equipment. Overcoat, topcoat, and prebond stranding available. We can stripe and print for your needs. SIS SIS Chemically Cross-linked Polyethylene (XLP) (90C) (600 Volts) (VW-1) (FT 1) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 14 7/22 Tinned.030.147 17 14 41/30 Tinned.030.150 20 12 7/20 Tinned.030.156 23 12 65/30 Tinned.030.160 28 10 105/30 Tinned.030.190 41 8 133/29 Tinned.045.270 74 6 133/27 Tinned.060.339 110 4 133/25 Tinned.060.391 165 2 133/23 Tinned.060.466 253 Used for instrument and control wiring of switchboards, annunciator circuits, and industrial control. We can stripe and print for your needs. 22

SR SR/3212/3213/3214 Braidless Fixture, Apparatus and Motor Lead (600 Volts) (150C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 16/30 Tinned.045.135 12 16 26/30 Tinned.045.148 16 14 41/30 Tinned.045.164 22 12 65/30 Tinned.045.180 31 10 105/30 Tinned.045.205 45 8 133/29 Tinned.060.285 80 6 133/27 Tinned.060.326 116 4 133/25 Tinned.060.381 172 2 259/26 Tinned.060.449 254 1 259/25 Tinned.080.532 325 1/0 259/24 Tinned.080.584 402 2/0 259/23 Tinned.080.625 510 3/0 259/22 Tinned.080.675 630 4/0 259/21 Tinned.080.746 773 Used for leads to motors, transformers, appliance, electric or other electrical circuits where a flexible conductor is required to operate under high temp conditions and where moisture may be present. Conductor is flexible stranded. A silicone compound is applied over the conductor. Braidless silicone is more flexible than silicone with a glass braid (SRML). SRML SRML/3071/3074/3075/3125/3231 Fiberglass Braided Fixture, Apparatus, and Motor Lead Wire (200C) (600 Volts) Insulation Wire Gauge (AWG) Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft Thickness 18 7/26 Tinned.030.111 13 16 7/24 Tinned.030.122 17 14 7/22 Tinned.030.142 23 12 19/25 Tinned.030.165 30 10 19/23 Tinned.045.217 51 8 54/25 Tinned.060.301 90 6 84/25 Tinned.060.323 121 4 133/25 Tinned.060.406 179 2 259/26 Tinned.060.474 274 1 259/25 Tinned.080.557 394 1/0 259/24 Tinned.080.609 434 2/0 259/23 Tinned.080.685 536 3/0 259/22 Tinned.080.735 670 4/0 259/21 Tinned.080.808 86 Used for leads to motors, transformers, appliance, electric or other electrical circuits where a flexible conductor is required to operate under high temp conditions and where moisture may be present. Conductor is flexible stranded. A silicone compound is applied over the conductor and the wire is then covered with a saturated frayresistant fiberglass braid. 23

TGGS TGGS/5256 (TGGS replaces TGGT) Apparatus Wire (250C) (600 Volts) (UL VW-1 and CSA FT 1) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 24 7/32 NPC.015.069 3.84 22 7/30 NPC.015.075 5.06 20 10/30 NPC.015.081 6.59 18 16/30 NPC.015.090 8.94 16 26/30 NPC.018.108 13.5 14 41/30 NPC.018.123 19.5 12 65/30 NPC.018.144 28.6 10 105/30 NPC.018.181 42.8 8 133/29 NPC.018.213 64.3 6 133/27 NPC.023.274 103 4 133/25 NPC.023.327 156 2 133/23 NPC.023.411 244 Used for wiring of domestic, commercial and industrial ovens, cooking, curing and drying equipment and similar high temp severe environments including electric heaters, blast furnaces and cement kilns. Flexible, stranded nickel-plated copper (NPC) conductor insulated with a composite of polytelrafluoroethylene (PTFE) tape and fiberglass serve jacketed with an overall fiberglass braid saturated and cured with a silicone saturator. Asbestos and halogen free. TGGS gives you the advantage of small diameter due to the reduced wall, yet still gives you the same temperature and voltage of the TGGT it replaces. TGGS is superior to TGGT in cutting and stripping. 24

Marine Wire Boat Cable/1426/BC-5W2 Flat Multi-conductor Marine Cable PVC White Jacket (105C Dry) (75C Wet) (600 Volts) M A R I N E W I R E Wire Gauge No. of Conduc-Conductotors Conductor Insulation Approx. Di- Approx. Lbs. (AWG) Color Stranding Thickness mensions per 1000 ft. 16 2 blk, wht 26/30 Tinned.030.204 x.328 44 16 3 blk, grn, wht 26/30 Tinned.030.204 x.452 64 14 2 blk, wht 41/30 Tinned.030.221 x.362 59 14 3 blk, grn, wht 41/30 Tinned.030.220 x.500 85 12 2 blk, wht 65/30 Tinned.030.238 x.396 78 12 3 blk, grn, wht 65/30 Tinned.030.240 x.560 114 10 2 blk, wht 105/30 Tinned.030.274 x.468 113 10 3 blk, grn, wht 105/30 Tinned.030.275 x.665 168 Can be used for marine and brake cable. Meets UL Standard 1426 and UL style BC-5W2. Type III stranding and is tinned copper to resist corrosion. GPTM (Tinned Copper) PVC Marine Wire SAE J-1128 and SAE J-378 (-40C to 105C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 16/30 Tinned.023.092 8.1 16 19/29 Tinned.023.103 10.8 14 19/27 Tinned.023.117 16 12 19/25 Tinned.026.142 24.5 10 19/23 Tinned.031.177 38.6 8 19/21 Tinned.037.222 61.2 Used in 105C marine applications and general circuit wiring. Marine spec printed, MARINE SAE J378 and J- 1128 105C AWG. We can stripe and print for your needs. GPTM (Bare Copper) PVC Marine Wire SAE J-1128 and SAE J-378 (-40C to 105C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 16/30 Bare.023.092 8.1 16 19/29 Bare.023.103 10.8 14 19/27 Bare.023.117 16 12 19/25 Bare.026.142 24.5 10 19/23 Bare.031.177 38.6 8 19/21 Bare.037.222 61.2 Used in 105C marine applications and general circuit wiring. Marine spec printed, MARINE SAE J378 and J- 1128 105C AWG. We can stripe and print for your needs. 25

TFFN/TFN UL 1316/1408/1452 Polyvinylchloride (PVC)/Nylon Primary Wire (90C) (600 Volts) (UL) (CSA) UL-1316, 105C Dry, 80C in Oil, 600 Volts UL-1408, 90C Dry, 60C Wet, or in Oil, 600 Volts UL-1452, 90C Dry, 80C in Oil, 1000 Volts CSA-TEWN or AWM I A/B 105C, 600 Volts, FT 1 Wire Gauge Conductor Insulation Thickness Lbs. per 1000ft Approximate UL Type Wire Thickness (AWG) Stranding TFFN/MTW 18 16/30 Bare.015 /.004.088 8 TFFN/MTW 16 26/30 Bare.015 /.004.100 12 TFN 18 Solid Bare.015 /.004.082 8 TFN 16 Solid Bare.015 /.004.093 11 Used for wiring of machine tools, appliances, control circuits, installations in conduit or other raceways and for new construction. Resistant to alkalis, grease, chemicals, gasoline, and oil. We can stripe and print to meet your needs. Romex TYPE NM-B Polyvinylchloride (PVC) Non-metallic Sheathed Cable (90C) (600 Volts) (UL Standard 83 and 719) Wire Gauge No. of Conductors Stranding ness Lbs. per 1000ft Conductor Insulation Thick- Approximate Wire Thickness (AWG) 14 2 Solid Bare.015 /.004.360 x.162 58 14 3 Solid Bare 015 /.004.307 75 12 2 Solid Bare 015 /.004.410 x.179 83 12 3 Solid Bare 015 /.004.347 109 10 2 Solid Bare.020 /.004.495 x.210 126 10 3 Solid Bare.020 /.004.422 167 8 2 7.030 /.005.612 x.269 187 8 3 7.030 /.005.565 254 6 2 7.030 /.005.683 x.304 256 6 3 7.030 /.005.650 357 4 3 7.040/.006.892 593 2 3 7.040/.006 1.034 856 Used for both exposed and concealed work in normally dry locations and is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. Meets federal specification A-A-59544 and requirements of National Code. Copper conductors are annealed soft bare copper. Stranded conductors are compressed bare stranded. Conductor insulation is 90C rated PVC, nylon jacketed. Cable jacket is color coded for quick size identification: 14AWG=White, 12AWG=Yellow, 10AWG=Orange, 8AWG, 6AWG, 4AWG, and 2AWG=Black. B U I L D I N G W I R E 26

THHN THHN/THWN/MTW/AWM Polyvinylchloride (PVC)/Nylon Primary Wire (90C) (600 Volts) (VW1) (UL) (CSA) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 14 19/.0147 Bare.015 /.004.110 15 14 Solid Bare 015 /.004.104 15 12 19/.0185 Bare 015 /.004.130 20 12 Solid Bare 015 /.004.121 20 10 19/.0234 Bare.020 /.004.170 30 10 Solid Bare.020 /.004.155 30 8 19/.0295 Bare.030 /.005.220 55 6 19/.0372 Bare.030 /.005.260 75 4 19/.0469 Bare.040 /.006.330 95 2 19/.0591 Bare.040 /.006.390 130 1 19/.0664 Bare.050 /.007.440 150 1/0 19/.0745 Bare.050 /.007.490 170 2/0 19/.0837 Bare.050 /.007.540 195 3/0 19/.0940 Bare.050 /.007.590 225 4/0 19/.1055 Bare.050 /.007.650 260 250 37/.0822 Bare.060 /.008.720 290 300 37/.0900 Bare.060 /.008.770 320 350 37/.0973 Bare.060 /.008.830 350 400 37/.1040 Bare.060 /.008.870 380 500 37/.1162 Bare.060 /.008.960 430 600 67/.0992 Bare.070 /.009 1.060 475 750 61/.1109 Bare.070 /.009 1.170 535 1000 61/.1280 Bare.07 /.009 1.350 615 Used for wiring of machine tools, appliances, control circuits, installations in conduit or other raceways and for new construction. Resistant to alkalis, grease, chemicals, gasoline, and oil. We can stripe and print to meet your needs. 27

XHHW XHHW-2 Chemically Cross-linked Polyethylene (XLP) (600 Volts) (90C) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 14 7/.0242 Bare.030.15 18 12 7/.0305 Bare.030.17 27 10 7/.0385 Bare.030.19 40 8 7/.0486 Bare.045.25 67 6 7/.0612 Bare.045.28 97 4 7/.0772 Bare.045.34 149 2 7/.0974 Bare.045.40 229 1 19/.0664 Bare.055.45 291 1/0 19/.0745 Bare.055.50 362 2/0 19/.0837 Bare.055.54 452 3/0 19/.0940 Bare.055.60 564 4/0 19/.1055 Bare.055.65 704 250 37/.0822 Bare.065.72 844 300 37/.0900 Bare.065.77 1005 350 37/.0973 Bare.065.82 1168 400 37/.1040 Bare.065.85 1323 500 37/.1162 Bare.065.95 1647 600 61/.0992 Bare.080 1.07 1950 750 61/.1109 Bare.080 1.17 2460 1000 61/.1208 Bare.080 1.28 3230 Used for general purpose wiring, for power distribution and branch circuit wiring, Used where cable having flame retardance is required. THW, XLP-USE type MC tray cable, interlocked armor cable, power cable, high voltage and trolley wire also available. 28

DLO Diesel Locomotive and Drilling Rig Cable Ethylene-propylene (EP) Rubber Insulation and Hypalon Jacket (90C) (2000 Volts) C O N T R O L C A B L E Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 8 37/24 Tinned.060.33 83 6 61/24 Tinned.060.41 109 4 105/24 Tinned.060.46 145 3 125/24 Tinned.060.48 167 2 150/24 Tinned.060.51 192 1 225/24 Tinned.080.65 223 1/0 275/24 Tinned.080.68 258 2/0 325/24 Tinned.080.72 298 3/0 450/25 Tinned.080.81 345 4/0 550/24 Tinned.080.84 400 262.6 650/24 Tinned.095.96 458 313.3 775/24 Tinned.095 1.04 514 373.7 925/24 Tinned.095 1.14 574 444.4 1100/24 Tinned.095 1.23 642 535.3 1325/24 Tinned.100 1.32 725 646.4 1600/24 Tinned.110 1.45 815 777.7 1925/24 Tinned.110 1.54 910 929.9 2318/24 Tinned.110 1.63 1.165 1111.0 2745/24 Tinned.125 1.83 1.350 Used for wiring of diesel electric locomotives and rail car equipment, mining and earth moving equipment, motor or generator leads, battery lead wires, welding leads, jumper leads, and offshore drilling rig applications. Abrasion resistant. Flexible stranding. Flame resistant. 29

European Flexible Control Cable PVC Control Tray Cable (90C) (60C Oil) (600 Volts) (UL) (CSA) (VDE) (CE) (VW-1, FT1, FT2) (Oil Resistant) Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 20 2 17/32BC 0.209 27 20 3 17/32BC 0.220 32 20 4 17/32BC 0.236 36 20 5 17/32BC 0.264 48 20 7 17/32BC 0.283 58 20 8 17/32BC 0.335 77 20 9 17/32BC 0.362 79 20 10 17/32BC 0.370 85 20 12 17/32BC 0.382 96 20 14 17/32BC 0.398 108 20 16 17/32BC 0.429 126 20 18 17/32BC 0.449 139 20 25 17/32BC 0.547 190 20 30 17/32BC 0.563 218 20 34 17/32BC 0.614 251 20 40 17/32BC 0.665 296 20 61 17/32BC 0.780 424 18 2 30/32BC 0.236 37 18 3 30/32BC 0.252 46 18 4 30/32BC 0.276 53 18 5 30/32BC 0.307 70 18 7 30/32BC 0.335 87 18 8 30/32BC 0.390 106 18 9 30/32BC 0.425 116 18 10 30/32BC 0.433 125 18 12 30/32BC 0.445 142 18 14 30/32BC 0.476 165 18 18 30/32BC 0.535 209 18 25 30/32BC 0.646 286 18 30 30/32BC 0.669 331 18 34 30/32BC 0.728 380 18 40 30/32BC 0.783 447 18 61 30/32BC 0.933 654 Used for use in all electrical equipment in dry, damp, and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment, and connections between control panels and machines. Suitable replacement for Olflex 190 series. Conductor is bare copper. 30

European Flexible Control Cable Continued PVC Control Tray Cable (90C) (60C Oil) (600 Volts) (UL) (CSA) (VDE) (CE) (VW-1, FT1, FT2) (Oil Resistant) Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 16 2 27-29/30BC 0.264 48 16 3 27-29/30BC 0.280 58 16 4 27-29/30BC 0.311 71 16 5 27-29/30BC 0.339 90 16 7 27-29/30BC 0.378 116 16 8 27-29/30BC 0.441 149 16 9 27-29/30BC 0.480 155 16 10 27-29/30BC 0.488 167 16 12 27-29/30BC 0.504 191 16 14 27-29/30BC 0.535 220 16 16 27-29/30BC 0.563 249 16 18 27-29/30BC 0.602 282 16 25 27-29/30BC 0.728 386 16 30 27-29/30BC 0.760 453 16 34 27-29/30BC 0.827 519 16 40 27-29/30BC 0.902 620 16 61 27-29/30BC 1.051 891 14 2 46/30BC 0.319 73 14 3 46/30BC 0.339 89 14 4 46/30BC 0.374 108 14 5 46/30BC 0.417 141 14 7 46/30BC 0.457 179 14 8 46/30BC 0.543 233 14 9 46/30BC 0.587 239 14 10 46/30BC 0.598 260 14 12 46/30BC 0.618 299 14 18 46/30BC 0.736 440 14 25 46/30BC 0.909 612 12 3 52/28BC 0.402 132 12 4 52/28BC 0.445 161 12 5 52/28BC 0.496 209 12 7 52/28BC 0.547 271 10 3 78/28BC 0.476 193 10 4 78/28BC 0.520 239 10 5 78/28BC 0.587 303 8 4 77/26BC 0.701 423 8 5 77/26BC 0.780 527 6 4 119/26BC 0.850 635 4 4 196/26BC 1.051 1006 2 4 280/26BC 1.197 1368 Used for use in all electrical equipment in dry, damp, and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment, and connections between control panels and machines. Suitable replacement for Olflex 190 series. Conductor is bare copper. 31

Flat Festoon PVC Entertainment PVC (-40C to 105C) (600 Volts) (UL VW-1 and CSA FT 1) Five Conductor Flat Cables (Black) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 12 5 65/30.030.260 x.990 230 10 5 105/30.030.290 x 1.150 330 8 5 133/30.030.360 x 1.520 477 6 5 259/30.030.450 x 1.920 800 4 5 413/30.030.515 x 2.200 1190 Used with festoon systems for the conveyance of electrical power and control to cranes, hoists, or any equipment which travels with a lateral traversing motion. Cables can also be used where space is at a premium, can be stacked, or where extreme flexing is a requirement. Recommended bend radius of three to five times cable diameter. Five conductor flat cables are widely used in convention halls and exhibit centers as under carpet cables for distribution and booth lighting. PVC Cable and PVC Shielded PVC (-40C to 105C) (600 Volts) (UL VW-1 and CSA FT 1) (Black or Yellow) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 16 8 65/34.030.225 x 1.170 194 16 12 65/34.030.225 x 1.700 292 14 4 105/34.030.240 x 0.690 138 14 8 105/34.030.240 x 1.290 254 14 12 105/34.030.240 x 1.825 380 12 4 65/30.030.260 x 0.800 180 12 8 65/30.030.260 x 1.440 343 10 4 105/30.030.290 x 0.890 239 8 4 168/30.045.375 x 1.225 401 6 4 259/30.060.450 x 1.500 635 4 4 413/30.060.515 x 1.750 896 2 4 665/30.060.575 x 1.975 1278 2/0 4 1323/30.080.800 x 2.820 2613 Shielded PVC (-40C to 105C) (600 Volts) (UL VW-1 and CSA FT 1) Each Conductor has Tinned Copper Braid Shield (Yellow) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 16 8 65/34.030.260 x 1.455 220 16 12 65/34.030.260 x 2.125 456 14 12 105/34.030.270 x 2.200 521 Bending radius is approx. four times the minor dimension (thickness). Jacket stripping is simplified by the use of ripcords, which are found in all of our flat constructions. UL listed for -40C. Can be used for operation at temps down to -55C. Passes the UL rating for the UV resistant test, making the cable suitable for outdoor use. 32

G/GGC Heavy Duty Portable Power Cable with Grounds (-40C to 90C) (600/2000V) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 8 3 133/.0113 Bare.060.955 671 6 3 259/.0100 Bare.060 1.045 872 4 3 259/.0127 Bare.060 1.170 1169 2 3 259/.0161 Bare.060 1.305 1566 1 3 259/.0180 Bare.080 1.505 2016 1/0 3 259/.0202 Bare.080 1.635 2492 2/0 3 259/.0227 Bare.080 1.740 2909 3/0 3 259/.0255 Bare.080 1.885 3426 4/0 3 259/.0286 Bare.080 2.095 4500 250 3 427/.0245 Bare.095 2.380 5445 350 3 427/.0286 Bare.095 2.730 7273 500 3 427/.0342 Bare.095 3.015 9439 6 4 133/.0142 Bare.060 1.130 930 4 4 133/.0179 Bare.060 1.240 1176 2 4 133/.0223 Bare.060 1.400 1644 2/0 4 259/.0227 Bare.080 1.915 3141 4/0 4 259/.0286 Bare.080 2.240 4661 8 3 133/.0113 Bare.060 0.81 478 6 3 259/.0100 Bare.060 0.93 629 4 3 259/.0127 Bare.060 1.08 906 2 3 259/.0160 Bare.060 1.27 1257 1 3 259/.0180 Bare.080 1.44 1648 1/0 3 259/.0202 Bare.080 1.52 1964 2/0 3 259/.0227 Bare.080 1.65 2313 3/0 3 259/.0225 Bare.080 1.77 2705 4/0 3 259/.0286 Bare.080 1.92 3469 250 3 427/.0245 Bare.095 2.10 4317 Used for cranes, conveyors, mobile equipment, temporary power supply use, portable and stationary heavyduty equipment, motor leads, locomotive wiring, welding machines and grounding cables. Cable is oil, sunlight, chemical and water resistant. 33

Pendant Pendant Cable (90C) (600 Volts) UL, CSA AWM I/II A/B Wire Gauge No. of Conductors Stranding ness per 1000ft Conductor Insulation Thick- Approximate Lbs. Wire Thickness (AWG) 16 8 65/34 BC.015/.005.470 138 16 12 65/34 BC.015/.005.550 198 16 16 65/34 BC.015/.005.610 225 16 24 65/34 BC.015/.005.745 370 Pendant Cable with Two Galvanized Steel Supports (1/16 ) (90C) (600 Volts) UL, CSA AWM I/II A/B Wire Gauge (AWG) Conductor Strand-Insulatioing Thickness No. of Conductors Wire Thickness 16 8 65/34 BC.015/.005.495 x.215 179 16 12 65/34 BC.015/.005.570 x.215 260 16 16 65/34 BC.015/.005.630 x.215 319 16 24 65/34 BC.016/.005.765 x.215 440 Approximate Lbs. per 1000ft Used in portable control, festoon systems, pendant stations, power tracks, cranes and hoists, power carriage systems, and other applications. Pendant cable is good in conditions where flame, chemicals, moisture and temperature extremes are considerations. STOOW Pendant Cable With Steel Core Messenger Yellow Type UL STOOW (VW-1) CSA STOOW (FT 1) with Black Steel Core Messenger (105C) (600 Volts) Wire Gauge No. of Conduc- Conductor Color Conductor Insulation Wire Thickness Approximate 16 3 yellow, blue, brown 65/34 BC.032.535 135 16 5 yellow, blue, brown, red, orange 65/34 BC.032.575 175 16 7 yellow, blue, brown, red, orange, white, purple 65/34 BC.032.620 215 34

SEOOW Service Cord UL Listed SEOOW (-50C to 105C) (600 Volts) CSA Approved STOOW (-50C to 105C) (600 Volts) Wire Gauge (AWG) No. of Conductors Conductor Color Conductor Stranding Insulation Thickness 18 2 black, white 16/30 Bare.031.345 59 18 3 black, white, green 16/30 Bare.031.365 69 18 4 black, white, green, red 16/30 Bare.031.395 81 16 2 black, white 26/30 Bare.031.370 71 16 3 black, white, green 26/30 Bare.031.390 81 16 4 black, white, green, red 26/30 Bare.031.420 99 14 2 black, white 41/30 Bare.046.505 126 14 3 black, white, green 41/30 Bare.046.525 149 14 4 black, white, green, red 41/30 Bare.046.575 160 12 2 black, white 65/30 Bare.046.570 163 12 3 black, white, green 65/30 Bare.046.595 199 12 4 black, white, green, red 65/30 Bare.046.645 242 10 2 black, white 104/30 Bare.046.620 207 10 3 black, white, green 104/30 Bare.046.655 259 10 4 black, white, green, red 104/30 Bare.046.705 316 Approximate Lbs. per 1000ft Used indoors and outdoors for garages, portable lights, battery chargers, portable stage lights, heavy tools and equipment exposed to oils, water, acids, chemicals, and solvents. Flame retardant and abrasion resistant. Portable Service Cord (-50C to 105C) (600 Volts) Wire Thickness No. of Wire Gauge Conductor Insulation Conductors Conductor Color Wire Thickness Approximate (AWG) Stranding Thickness Lbs. per 1000ft 8 3 black, white, green 96/28.048.700 332 8 4 black, white, green, red 96/28.048.783 425 8 5 black, white, red, green, 96/28 orange.048.850 509 6 2 black, white 96/26.048.752 332 6 3 black, white, green 96/26.048.818 473 6 4 black, white, green, red 96/26.048.892 594 4 3 black, white, green 96/24.048.982 677 4 4 black, white, green, red 96/24.048 1.104 886 2 3 black, white, green 7 17/23.050 1.158 1024 2 4 black, white, green, red 7 17/23.050 1.267 1350 Used for portable power, machine shops, mills, garages, aircraft maintenance facilities, machine tools, portable power equipment, portable appliances, mixers, washing machines and polishers. Provides greater flexibility and resistance to oils, lubricants, and grease. Portable control cable of 5 conductors or more is also available. 35

SJEOOW Service Cord UL Listed SJEOOW (-50C to 105C) (600 Volts) CSA Approved STOOW (-50C to 105C) (600 Volts) Wire Gauge (AWG) No. of Conductors Conductor Color Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 2 black, white 16/30 Bare.031.290 44 18 3 black, white, green 16/30 Bare.031.310 55 18 4 black, white, green, red 16/30 Bare.031.335 66 16 2 black, white 26/30 Bare.031.315 54 16 3 black, white, green 26/30 Bare.031.335 67 16 4 black, white, green, red 26/30 Bare.031.360 78 14 2 black, white 41/30 Bare.031.345 68 14 3 black, white, green 41/30 Bare.031.370 84 14 4 black, white, green, red 41/30 Bare.031.400 104 12 2 black, white 65/30 Bare.031.415 97 12 3 black, white, green 65/30 Bare.031.435 123 12 4 black, white, green, red 65/30 Bare.031.475 157 10 2 black, white 104/30 Bare.046.549 166 10 3 black, white, green 104/30 Bare.046.580 216 10 4 black, white, green, red 104/30 Bare.046.640 276 Used indoors and outdoors for garages, portable lights, battery chargers, portable stage lights, heavy tools and equipment exposed to oils, water, acids, chemicals, and solvents. Flame retardant and abrasion resistant. Stagelighting Entertainment Chlorinated Polyethylene (CPE) (UL Type SC) (CSA Type PPC) (105C) (600V) Wire Gauge (AWG) Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 8 162/30.105.385 115 6 259/30.105.430 150 4 418/30.105.475 210 2 660/30.105.540 300 1 836/30.105.580 365 1/0 1056/30.105.615 440 2/0 1320/30.105.655 555 3/0 1672/30.105.720 640 4/0 2090/30.105.780 805 Used for portable power systems and entertainment industry activities such as theatre, television, night clubs, motion pictures, mobile communication vans, spotlights and sound systems and other similar applications that require temporary power. Both water and sun resistant, and is designed to withstand severe environmental conditions. Withstands exposure to oil, acids, alkalis, heat, flame, moisture and chemicals. Meets or exceeds flame test requirements of MSHA, ICEA and UL. 36

SJOOW Portable Service Cord (-40C to 90C) (300 Volts) UL Listed/CSA Certified Wire Gauge (AWG) Conductor Color Conductor Stranding Insulation Thickness Wire Thickness Approximate Lbs. per 1000ft 18 2 black, white 16/30 Bare.030.29 45 18 3 black, white, green 16/30 Bare.030.31 55 18 4 black, white, green, red 16/30 Bare.030.34 70 16 2 black, white 26/30 Bare.030.31 55 16 3 black, white, green 26/30 Bare.030.33 70 16 4 black, white, green, red 26/30 Bare.030.37 85 14 2 black, white 41/30 Bare.030.34 75 14 3 black, white, green 41/30 Bare.030.37 95 14 4 black, white, green, red 41/30 Bare.030.41 120 12 2 black, white 65/30 Bare.030.42 110 12 3 black, white, green 65/30 Bare.030.44 145 12 4 black, white, green, red 65/30 Bare.030.48 180 10 2 black, white 104/30 Bare.045.57 170 10 3 black, white, green 104/30 Bare.045.60 240 10 4 black, white, green, red 104/30 Bare.045.66 300 Used indoors and outdoors for garages, portable lights, battery chargers. portable stage lights, heavy tools and equipment exposed to oils, water and acids. SJTOOW No. of Conductors Portable Service Cord PVC (-40C to 105C) (300 Volts) VW-1 UL Listed/CSA Certified No. of Wire Gauge Conductor Insulation Conductors Conductor Colors Wire Thickness Approximate (AWG) Stranding Thickness Lbs. per 1000ft 18 2 black, white 16/30 Bare.030.288 40 18 3 black, white, green 16/30 Bare.030.306 50 18 4 black, white, red, green 16/30 Bare.030.335 60 16 2 black, white 26/30 Bare.030.312 45 16 3 black, white, green 26/30 Bare.030.332 65 16 4 black, white, red, green 26/30 Bare.030.364 80 14 2 black, white 41/30 Bare.030.348 60 14 3 black, white, green 41/30 Bare.030.371 85 14 4 black, white, red, green 41/30 Bare.030.407 110 12 2 black, white 65/30 Bare.030.409 95 12 3 black, white, green 65/30 Bare.030.434 125 12 4 black, white, red, green 65/30 Bare.030.475 160 10 2 black, white 105/30 Bare.045.552 165 10 3 black, white, green 105/30 Bare.045.586 215 10 4 black, white, red, green 105/30 Bare.045.641 270 Used for portable power, machine shops, mills, garages, aircraft maintenance facilities, machine tools, portable power equipment, portable appliances, mixers, washing machines and polishers. Thermoplastic cord provides greater flexibility and resistance to oils, lubricants, and grease. 37

SOOW Portable Service Cord (-40C to 90C) (600 Volts) VW-1 UL Listed/CSA Certified Wire Gauge (AWG) No. of Conductors Conductor Color Conductor Stranding Insulation Thickness Wire Thickness 18 2 black, white 16/30 Bare.030.35 70 18 3 black, white, green 16/30 Bare.030.37 80 18 4 black, white, green, red 16/30 Bare.030.40 95 16 2 black, white 26/30 Bare.030.37 80 16 3 black, white, green 26/30 Bare.030.40 95 16 4 black, white, green, red 26/30 Bare.030.43 120 14 2 black, white 41/30 Bare.045.51 145 14 3 black, white, green 41/30 Bare.045.54 170 14 4 black, white, green, red 41/30 Bare.045.58 210 12 2 black, white 65/30 Bare.045.58 195 12 3 black, white, green 65/30 Bare.045.61 235 12 4 black, white, green, red 65/30 Bare.045.66 285 10 2 black, white 104/30 Bare.045.64 245 10 3 black, white, green 104/30 Bare.045.67 300 10 4 black, white, green, red 104/30 Bare.045.73 365 Approximate Lbs. per 1000ft Used indoors and outdoors for garages, portable lights, battery chargers. portable stage lights, heavy tools and equipment exposed to oils, water and acids. SPT PVC (300 Volts) (105C) (UL and CSA) Wire Gauge (AWG) No. of Conductors Conductor Stranding Insulation Thickness Wire Thickness 18 2 41/34 Bare.030.111 x.208 19 18 3 41/34 Bare.030.120 x.296 29 18 2 41/34 Bare.045.140 x.270 26 18 3 41/34 Bare.045.143 x.334 36 16 2 65/34 Bare.045.156 x.302 35 16 3 65/34 Bare.045.154 x.375 48 18 2 16/30 Bare.060.177 x.336 36 18 3 16/30 Bare.060.175 x.385 45 16 2 26/30 Bare.060.190 x.363 45 16 3 26/30 Bare.060.187 x.429 58 14 2 41/30 Bare.075.235 x.430 69 14 3 41/30 Bare.075.235 x.510 89 12 2 65/30 Bare.080.290 x.490 101 12 3 65/30 Bare.080.281 x.600 131 Approximate Lbs. per 1000ft Used for fans, clocks, lamps, radios, small display signs and similar appliances. Limited usage 3 conductor wires have green center wire for ground use only. One side is ribbed for circuit identification. Normal colors are black, brown, and white. 38

STOW Portable Service Cord PVC (-35C to 60C) (600 Volts) UL Listed/CSA Certified Wire Gauge (AWG) No. of Conductors Conductor Colors Conductor Stranding Insulation Thickness Wire Approximate Thickness Lbs. per 1000ft 18 2 black, white 16/30 Bare.030.340 61 18 3 black, white, green 16/30 Bare.030.370 77 18 4 black, white, red, green 16/30 Bare.030.395 90 16 2 black, white 26/30 Bare.030.375 68 16 3 black, white, green 26/30 Bare.030.390 87 16 4 black, white, red, green 26/30 Bare.030.420 105 14 2 black, white 41/30 Bare.045.505 128 14 3 black, white, green 41/30 Bare.045.530 152 14 4 black, white, red, green 41/30 Bare.045.575 185 12 2 black, white 65/30 Bare.045.575 184 12 3 black, white, green 65/30 Bare.045.600 209 12 4 black, white, red, green 65/30 Bare.045.650 255 10 2 black, white 105/30 Bare.045.625 219 10 3 black, white, green 105/30 Bare.045.660 271 10 4 black, white, red, green 105/30 Bare.045.715 333 8 3 black, white, green 65/.016 Bare.060.840 430 8 4 black, white, red, green 65/.016 Bare.060.950 550 6 3 black, white, green 133/.014 Bare.060.990 605 6 4 black, white, red, green 133/.014 Bare.060 1.100 780 Used for portable power, machine shops, mills, garages, aircraft maintenance facilities, machine tools, portable power equipment, portable appliances, mixers, washing machines and polishers. Thermoplastic cord provides greater flexibility and resistance to oils, lubricants, and grease. 39

Thermostat Cable PVC Jacket with Sun Resistance (60C) UL Type CL2, NEC Article 725, CUL Type CM/FT 1, California State Fire Marshal Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 20 2 Solid.006.114 10 20 3 Solid.006.121 13 20 4 Solid.006.132 17 20 5 Solid.006.147 21 20 6 Solid.006.160 25 20 7 Solid.006.168 29 20 8 Solid.006.181 33 20 9 Solid.006.193 36 20 10 Solid.006.210 40 20 12 Solid.006.217 47 18 2 Solid.006.132 14 18 3 Solid.006.140 20 18 4 Solid.006.154 26 18 5 Solid.006.170 32 18 6 Solid.006.186 38 18 7 Solid.006.194 45 18 8 Solid.006.210 50 18 9 Solid.006.226 56 18 10 Solid.006.246 62 18 12 Solid.006.254 75 Normal color code is red, white, green, blue, yellow, brown, orange, black, pink, gray, tan, and purple. Used in power limited circuit cable for use in thermostat controls, heating and air conditioning units and other low voltage applications. 40

Tray Cable Tray Cable PVC PVC Control Tray Cable (90C Dry) (75C Wet) (600 Volts) (VW-1) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 16 2 19 x.0117 Bare 0.015.20 x.30 45 16 3 20 x.0117 Bare 0.015 0.31 60 16 4 21 x.0117 Bare 0.015 0.35 70 16 5 22 x.0117 Bare 0.015 0.39 90 16 6 23 x.0117 Bare 0.015 0.42 105 16 7 24 x.0117 Bare 0.015 0.42 115 16 9 25 x.0117 Bare 0.015 0.45 145 16 12 26 x.0117 Bare 0.015 0.57 185 14 2 19 x.0147 Bare 0.015.21 x.33 55 14 3 20 x.0147bare 0.015 0.34 80 14 4 21 x.0147 Bare 0.015 0.38 100 14 5 22 x.0147 Bare 0.015 0.41 115 14 6 23 x.0147 Bare 0.015 0.45 140 14 7 24 x.0147 Bare 0.015 0.45 150 14 9 25 x.0147 Bare 0.015 0.52 195 14 12 26 x.0147 Bare 0.015 0.6 265 14 15 27 x.0147 Bare 0.015 0.68 325 14 19 28 x.0147 Bare 0.015 0.71 390 14 24 29 x.0147 Bare 0.015 0.83 490 14 30 30 x.0147 Bare 0.015 0.92 625 14 37 31 x.0147 Bare 0.015 0.99 745 12 2 19 x.0185 Bare 0.015.23 x.37 75 12 3 20 x.0185 Bare 0.015 0.39 110 12 4 21 x.0185 Bare 0.015 0.42 135 12 5 22 x.0185 Bare 0.015 0.47 165 12 6 23 x.0185 Bare 0.015 0.5 195 12 7 24 x.0185 Bare 0.015 0.5 215 12 8 25 x.0185 Bare 0.015 0.58 270 12 9 26 x.0185 Bare 0.015 0.62 295 12 12 27 x.0185 Bare 0.015 0.7 380 12 15 28 x.0185 Bare 0.015 0.71 465 12 19 29 x.0185 Bare 0.015 0.81 565 12 24 30 x.0185 Bare 0.015 0.99 750 12 30 31 x.0185 Bare 0.015 1.04 905 12 37 32 x.0185 Bare 0.015 1.12 1085 10 2 19 x.0234 Bare 0.02.26 x.43 110 10 3 20 x.0234 Bare 0.02 0.46 165 10 4 21 x.0234 Bare 0.02 0.5 205 10 5 22 x.0234 Bare 0.02 0.58 270 10 6 23 x.0234 Bare 0.02 0.63 325 10 7 24 x.0234 Bare 0.02 0.63 345 10 9 25 x.0234 Bare 0.02 0.78 440 10 12 26 x.0234 Bare 0.02 0.83 580 Used for cable tray, raceway, direct burial and aerial installations where supported by a messenger. Heat, flame, moisture, oil, gasoline, chemical and corrosion resistant. 41

Tray Cable Continued Tray Cable PVC Power (90C Dry) (75C Wet) (600 Volts) (VW-1) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 8 3 7/.0486 Bare.030.600 274 8 4 7/.0486 Bare.030.660 348 6 3 7/.0612 Bare.030.680 442 6 4 7/.0612 Bare.030.750 497 4 3 7/.0772 Bare.040.875 638 4 4 7/.0772 Bare.040.960 807 2 3 7/.0974 Bare.040 1.005 935 2 4 7/.0974 Bare.040 1.105 1186 1/0 3 19/.0745 Bare.050 1.230 1431 2/0 3 19/.0837 Bare.050 1.325 1720 4/0 3 19/.1055 Bare.050 1.570 2586 350 3 37/.0973 Bare.060 2.000 4244 500 3 37/.1162 Bare.060 2.280 5809 Used for cable tray, raceway, direct burial and aerial installations when supported by a messenger. Resistant to sunlight, oil, gasoline, flame and moisture. Tray Cable PVC Power with Ground PVC (90C Dry) (75C Wet) (600 Volts) (VW-1) Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 8 3 7/.0486 Bare.030.615 308 6 3 7/0.612 Bare.030.705 437 4 3 7/.0772 Bare.040.890 675 2 3 7/.0974 Bare.040 1.015 1001 1/0 3 19/.0745 Bare.050 1.240 1518 2/0 3 19/.0837 Bare.050 1.335 1814 3/0 3 19/.0940 Bare.050 1.445 2254 4/0 3 19/1.055 Bare.050 1.570 2722 250 3 37/.0822 Bare.060 1.775 3361 350 3 37/.0973 Bare.060 2.000 4523 500 3 37/.1162 Bare.060 2.280 6225 Used for cable tray, raceway, direct burial and aerial installations when supported by a messenger. Sunlight, oil, gasoline, flame and moisture resistant. Conductor identification the individual conductors are colored black and identified with white alpha numerical printing per ICEA Method 4. Tray Cable TPE Used in small diameter applications for steel, paper, chemical, textile, petroleum, cranes, hoists, mechanical arms, and other light and heavy industrial facilities. Designed for tight installations and continuous flexing. Good against oil, gasoline, ozone, chemicals and abrasions. 42

Tray Cable TPE Continued Tray Cable TPE Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 18 5 16/30 Bare.355 69 18 6 16/30 Bare.380 80 18 7 16/30 Bare.380 87 18 8 16/30 Bare.410 100 18 10 16/30 Bare.470 125 18 12 16/30 Bare.485 142 18 16 16/30 Bare.565 191 18 21 16/30 Bare.620 245 18 24 16/30 Bare.680 280 18 30 16/30 Bare.715 336 18 37 16/30 Bare.770 405 16 2 26/30 Bare.310 48 16 3 26/30 Bare.330 61 16 4 26/30 Bare.355 77 16 5 26/30 Bare.385 93 16 6 26/30 Bare.415 110 16 7 26/30 Bare.415 119 16 8 26/30 Bare.445 137 16 10 26/30 Bare.515 171 16 12 26/30 Bare.560 209 16 16 26/30 Bare.615 261 16 21 26/30 Bare.675 342 16 24 26/30 Bare.715 394 16 30 26/30 Bare.785 472 14 2 41/30 Bare.335 58 14 3 41/30 Bare.350 76 14 4 41/30 Bare.380 96 14 5 41/30 Bare.410 116 14 6 41/30 Bare.445 138 14 7 41/30 Bare.445 151 14 8 41/30 Bare 0.48 174 14 10 41/31 Bare 0.59 234 14 12 41/32 Bare 0.61 265 14 16 41/33 Bare 0.70 335 14 21 41/34 Bare 0.77 440 14 24 41/35 Bare 0.85 504 14 30 41/36 Bare 0.94 646 14 37 41/37 Bare 0.97 773 12 3 65/30 Bare 0.41 109 12 4 65/30 Bare 0.45 145 12 5 65/30 Bare 0.49 170 12 6 65/30 Bare 0.53 202 12 7 65/30 Bare 0.54 223 12 8 65/30 Bare 0.60 271 12 10 65/30 Bare 0.69 340 12 12 65/30 Bare 0.71 391 12 16 65/30 Bare 0.79 498 12 21 65/30 Bare 0.91 689 12 24 65/30 Bare 1.00 788 12 30 65/30 Bare 1.05 944 12 37 65/30 Bare 1.16 1166 43

W Heavy Duty Portable Power Cable (-40C to 90C) (2000 Volts) Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 8 1 133 0.44 130 6 1 133 0.51 185 4 1 133 0.57 253 3 1 133 0.63 307 2 1 133 0.66 369 1 1 133 0.74 467 1/0 1 259 0.77 541 2/0 1 259 0.82 650 3/0 1 259 0.87 778 4/0 1 259 0.93 962 250 1 427 1.03 1282 300 1 427 1.09 1502 350 1 427 1.15 1713 400 1 427 1.20 1941 500 1 427 1.31 2389 Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 8 2 133 0.81 295 6 2 133 0.93 416 4 2 133 1.08 588 3 2 133 1.17 689 2 2 133 1.27 864 1 2 133 1.44 1095 1/0 2 259 1.52 1238 2/0 2 259 1.65 1503 3/0 2 259 1.77 1793 4/0 2 259 1.92 2217 250 2 427 2.10 2828 300 2 427 2.22 3274 350 2 427 2.36 3750 400 2 427 2.47 4226 500 2 427 2.70 5190 ire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 8 3 133 0.91 423 6 3 133 1.01 568 4 3 133 1.17 805 3 3 133 1.24 920 2 3 133 1.34 1148 1 3 133 1.51 1448 1/0 3 259 1.65 1739 2/0 3 259 1.75 2058 3/0 3 259 1.89 2491 4/0 3 259 2.04 3080 250 3 427 2.39 4271 300 3 427 2.56 5027 350 3 427 2.68 5662 400 3 427 2.82 6424 500 3 427 3.03 7755 44

W Continued Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 6 4 133 1.10 711 4 4 133 1.27 1008 3 4 133 1.34 1148 2 4 133 1.48 1147 1 4 133 1.68 1881 1/0 4 259 1.79 2195 2/0 4 259 1.93 2658 3/0 4 259 2.07 3197 4/0 4 259 2.26 4012 250 4 427 2.66 5580 300 4 427 2.84 6550 350 4 427 2.98 7403 400 4 427 3.14 8417 500 4 427 3.40 10249 Wire Gauge (AWG) No. of Conductors Conductor Stranding Wire Thickness Approximate Lbs. per 1000ft 8 5 133 1.07 625 6 5 133 1.21 870 4 5 133 1.4 1238 3 5 133 1.48 1415 2 5 133 1.61 1788 1 5 133 1.88 2357 1/0 5 259 1.96 2680 2/0 5 259 2.13 3278 3/0 5 259 2.26 3899 4/0 5 259 2.46 4885 Used for cranes, conveyors, mobile equipment, temporary power supply use, portable and stationary heavyduty equipment, motor leads, locomotive wiring, welding machines and grounding cables. Cable is oil, sunlight, chemical and water resistant. 45

Coaxial, Security, Video, Plenum, and Non-Plenum RG6, RG8, RG11, RG58, RG59, RG62, RG71, RG122, RG142, RG174, RG178, RG179, RG180, RG187, RG188, RG196, RG212, RG213, RG214, RG216, RG217, RG223, RG303, RG316, RG401, RG402, RG405. Other types available. Voice, Data, and Premise Wire Voice, Data, and Premise Wire Overall Shield/Multiple Conductor UL Type CMR, CL3R, 75C Wire Gauge Conductor Strandinness Lbs. per 1000ft Insulation Thick- Approximate No. of Conductors Wire Thickness (AWG) 22 2 7BC.015.13 12 22 3 7BC.015.14 16 22 4 7BC.015.15 20 22 6 7BC.015.17 26 22 8 7BC.015.20 31 22 12 7BC.015.23 42 20 2 7BC.015.15 17 20 3 7BC.015.15 21 20 4 7BC.015.17 25 18 2 7BC.015.16 21 18 3 7BC.015.17 28 18 4 7BC.015.19 35 18 6 7BC.015.23 50 18 8 7BC.015.25 63 18 12 7BC.015.30 90 16 2 19BC.015.19 29 16 3 19BC.015.20 39 16 4 19BC.015.22 50 14 2 19BC.015.25 46 14 3 19BC.015.25 61 14 4 19BC.015.27 79 Used in remote control signaling, power-limited circuits, security, intercom, public address, sound, and audio systems. Offers protection from electrostatic interference. Conductors are soft bare annealed copper per ASTM B-3. Insulation is semi-rigid PVC. Jacket is gray PVC with a ripcord applied longitudinally under the jacket. Additional Standards: 22AWG-16AWG: UL standard 13, NEC Article 725 Type CL3R and Ul Standard 444, NEC Article 800 Type CMR; - UL stadard 13, NEC Article 725 Type CL3R. E L E C T R I O N I C W I R E 46

Voice, Data, and Premise Wire Voice, Data, and Premise Wire Non-shielded/Multiple Conductor UL Type CMR, CL3R, 75C Wire Gauge Conductor Strandinness per 1000ft Insulation Thick- Approximate Lbs. No. of Conductors Wire Thickness (AWG) 22 2 7BC.008.12 9 22 3 7BC.008.14 13 22 4 7BC.008.16 17 22 6 7BC.008.17 22 22 8 7BC.008.18 27 22 12 7BC.008.22 42 20 2 7BC.008.13 11 20 3 7BC.008.13 18 20 4 7BC.008.14 22 18 2 7BC.009.16 18 18 3 7BC.009.17 24 18 4 7BC.009.18 31 18 6 7BC.009.23 46 18 8 7BC.009.25 59 18 12 7BC.009.29 86 16 2 19BC.009.18 26 16 3 19BC.009.19 35 16 4 19BC.009.21 47 14 2 19BC.013.22 41 14 3 19BC.013.24 55 14 4 19BC.013.26 72 12 2 19BC.013.26 57 Used in remote control signaling, power-limited circuits, security, intercom, public address, sound, and audio systems. Offers protection from electrostatic interference. Conductors are soft bare annealed copper per ASTM B-3. Insulation is semi-rigid PVC. Jacket is gray PVC with a ripcord applied longitudinally under the jacket. Additional Standards: 22AWG-16AWG: UL standard 13, NEC Article 725 Type CL3R and Ul Standard 444, NEC Article 800 Type CMR; - UL stadard 13, NEC Article 725 Type CL3R. Telephone Silver Satin Polyvinylchloride (PVC) 60C 150V AWM 20251 Wire Gauge No. of (AWG) Conductors Conductor Colors 26 4 black, red, green, yellow 26 6 white, black, red, green, yellow, blue blue, orange, black, 26 8 red, green, yellow, brown, gray Conductor Stranding Insulation Approximate Wire Thickness Thickness 7/.16 mm 7/34.009.23mm.098 x.197 2.5 x 5.0 7/.16 mm 7/34.009.23mm.098 x.276 2.5 x 7.0 7/.16 mm 7/34.009.23mm.098 x.347 2.5 x 8.8 Lbs. per 1000ft 12 18 23 47

Bonded Wire At ADI we receive many requests for bonded wire products in special color combinations, wire types, striped wires, sizes, and combinations of these. We will create what you need to suit your needs and provide samples for your review. Over the years we have created many combinations not often found in the industry. We have also created special machines to meet those needs. If you would like to see what ADI can do for you please fill out the quote form and we will quote your request and see if our service is right for you. All of our bonded wire is custom made to your order, sometimes we have over runs which we keep in stock. Just need a small piece? Give us a call we may have what you need available now. B O N D E D W I R E 48

Uninsulated Wire U N I N S U L A T E D W I R E Uninsulated Solid and Stranded Class AA, B, C, and A Wire Gauge (AWG) Conductor Stranding Nominal Circular Mil. Wire Thickness Approximate Lbs. per 14 Solid, Bare or Tinned 4110 64.1 12.4 13 Solid, Bare or Tinned 5180 72 15.7 12 Solid, Bare or Tinned 6530 80.8 19.8 11 Solid, Bare or Tinned 8230 90.7 24.9 10 Solid, Bare or Tinned 10380 101.9 31.4 9 Solid, Bare or Tinned 13090 114.4 39.6 8 Solid, Bare or Tinned 16510 128.5 50 7 Solid, Bare or Tinned 20820 144.3 63 6 Solid, Bare or Tinned 26240 162.0 79.4 5 Solid, Bare or Tinned 33090 181.9 100.2 4 Solid, Bare or Tinned 41740 204.3 126.3 3 Solid, Bare or Tinned 52620 229.4 159.3 2 Solid, Bare or Tinned 66360 257.6 200.9 1 Solid, Bare or Tinned 83690 289.3 253.3 Used for applications such as point to point wiring, component leads, and ground wire. Bare copper wire and cable meets or exceeds the following ASTM Specifications: B-1 Hard-Drawn, B-2 Medium-Drawn, B-3 Soft of Annealed, B-8 Concentric-Lay (Hard, Medium and Soft) Uninsulated Solid Bus Bar Wire MIL-W-3861 Type S, A-A-59551 (Supercedes QQ-W-343 Type S) Wire Gauge (AWG) Nominal Circular Mil. Approximate Lbs. per Conductor Stranding Wire Thickness NO. Area 1000ft 30 Solid, Bare or Tinned 100.5.0100.3042 28 Solid, Bare or Tinned 159.8.0126.4837 26 Solid, Bare or Tinned 254.1.0159.7692 24 Solid, Bare or Tinned 404.0.0201 1.223 22 Solid, Bare or Tinned 642.4.0253 1.945 20 Solid, Bare or Tinned 1022.0.0320 3.092 18 Solid, Bare or Tinned 1624.0.0403 4.917 16 Solid, Bare or Tinned 2583.0.0508 7.818 14 Solid, Bare or Tinned 4107.0.0641 12.43 12 Solid, Bare or Tinned 6530.0.0808 19.77 10 Solid, Bare or Tinned 10380.0.1019 31.43 8 Solid, Bare or Tinned 16510.0.1290 50.0 Used for applications such as point to point wiring, component leads, and ground wire. 49

Uninsulated Wire Uninsulated Tinned Copper Flat Braids ASTM-B-33, A-A-59569 (Supersedes QQB575) Nominal Flat Nominal No. of No. of Wire AWG Nominal AWG of Ends Total Ends Width Thickness Strands per Strand Equivalent CMA 1/8.020 36 24 3 72 18 1,800 3/16.020 36 24 5 120 15 3,000 1/4.030 36 24 7 168 14 4,200 3/8.030 36 48 6 288 12 7,200 1/2.030 36 48 8 384 10 9,600 3/4.040 36 48 18 864 7 20,800 1.045 36 48 18 864 7 20,800 2.140 30 48 32 1,536 3/0 153,600 3.190 30 48 47 2,256 4/0 225,600 Used for bonding straps, grounding, or connecting moving parts. Uninsulated Tinned Copper Tubular Braids ASTM-B-33, A-A-59569 (Supersedes QQB575) Nominal ID AWG of Ends No. of Strands No. of Wire per Total Ends AWG Equiva- Nominal CMA 1/8 36 24 5 120 15 3,000 1/4 36 24 16 384 10 9,600 3/8 36 48 8 384 10 9,600 1/2 36 48 11 528 9 13,200 25/32 36 48 18 864 7 21,600 Used for bonding straps, grounding, connecting moving parts, shielding, and for protective covering. Uninsulated Tinned Extra Flexible Copper Rope ASTM-B-33 (Bundled per ASTM B172) AWG Size AWG of Ends Conductor Stranding Thickness in inches Weight in 1000 s 10 36 413/36.13 33 8 36 665/36.166 53 6 36 1050/36.204 83 4 36 1666/36.29 134 2 36 665/30.335 211 Used for applications such as point to point wiring, component leads, grounding, or connecting moving parts. 50

B Telecomm Connectors T E R M I N A L S B Telecomm Connectors feature: 300 maximum volt rating 15 amperage rating. WIRE RANGE WIDTH LENGTH SILICONE INSULATION CONNECTOR MATERIAL Bullets MALE 20-16 0.157 0.984 NO BRASS 20-16 0.157 1.024 YES BRASS WIRE RANGE A.W.G. ELECTRICAL CURRENT VOLTS INSULATION MATERIAL 22-16 (.156) 10 amperes 300V Vinyl and Nylon 16-14 (.156) 15 amperes 300V Heat shrink, Bare, Vinyl or Nylon 16-14 (.195) 15 amperes 300V vinyl FEMALE WIRE RANGE A.W.G. ELECTRICAL CURRENT VOLTS INSULATION MATERIAL 22-16 (.156) 10 amperes 300V Vinyl and Nylon 16-14 (.156) 15 amperes 300V Heat shrink, Vinyl and Nylon 16-14 (.195) 15 amperes 300V Vinyl and Nylon NYLON 2 Way Connector.157 51

Butt Splice VINYL Vinyl insulated Butt Splice Connectors feature: 75 degrees C (167 degrees F) maximum temperature 300 maximum volt rating Brass conductive plate NYLON Nylon insulated Butt Splice Connectors feature: 105 degrees C (221 degrees F) maximum temperature 600 maximum volt rating Copper conductive plate BARE WIRE RANGE DIMENSIONS (inches/mm) ELECTRICAL INSULATION A.W.G. L D d1 CURRENT MATERIAL 22-16 0.953 24.2 0.157 4.0 0.067 1.7 10 amperes vinyl 16-14 0.953 24.2 0.177 4.5 0.091 2.3 15 amperes vinyl 12-10 1.024 26.0 0.248 6.3 0.134 3.4 24 amperes vinyl WIRE RANGE A.W.G. DIMENSIONS (inches/mm) L D d1 ELECTRICAL CURRENT 22-16 1.075 27.3 0.126 3.2 0.067 1.7 19 amperes 16-14 1.075 27.3 0.150 3.8 0.091 2.3 27 amperes 12-10 1.075 27.3 0.209 5.3 0.134 3.4 48 amperes INSULATION MATERIAL Nylon, Heat Shrink, and Heat shrink with solder Nylon, Heat Shrink, and Heat shrink with solder Nylon, Heat Shrink, and Heat shrink with solder WIRE RANGE A.W.G. ELECTRICAL CURRENT VOLTS INSULATION MATERIAL 22-16 19 amperes 600V Bare 16-14 19 amperes 600V Bare 14-12 19 amperes 600V Bare Lug Size WIRE RANGE A.W.G. INSULATION MATERIAL 8 Bare and Vinyl 6 Bare and Vinyl 4 Bare and Vinyl 52

Closed End Crimp Connectors TEMP. COLOR A.W.G. VOLTAGE (C/F) Natural (off white) 22-18 300V 105/221 Natural (off white) 22-14 300V 105/221 Natural (off white) 22-10 300V 105/221 Natural (off white) 16-10 300V 600V (CSA) 105/221 Cradle Tie Mounts Cradle Mounts feature: Lower cradle design and thicker support arms, providing greater strength and usability for larger bundles. Dimensions designed to accommodate tight areas Easily secured with a standard flat or phillips head bolt or screw. Manufactured from 100% Nylon 6/6 CABLE TIES DIMENSIONS STUD SIZE ACCEPTED 0.59 x 0.39 x 0.28 (15 x 10 x 7) #4 up to 0.19 (4.8mm) 0.90 x 0.63 x 0.35 (23 x 16 x 9) #10 up to 0.31 (7.9mm) 53

Flags WIRE RANGE NEMA TAB ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V Nylon 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V Nylon And Bare Hooks WIRE RANGE STUD ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 #6 19 amperes 600V vinyl 22-16 #8 19 amperes 600V vinyl 16-14 #6 27 amperes 600V vinyl 16-14 #8 27 amperes 600V vinyl 16-14 #10 27 amperes 600V vinyl 12-10 #10 48 amperes 600V vinyl 54

Push-in Wire Connectors Reduce installation costs. No twisting; simply push stripped wires into each port for a safe and reliable connection. 22-12 AWG, up to 600 volts (1000V in lighting fixtures, luminaries, and signs) and 221oF for solid or stranded copper wires. Color-coded transparent polycarbonate housing (flame-retardant to UL92-V2 or UL92-V0) allows for quick and accurate visual identification and inspection. Ergonomically located test slot allows for easy testing with a voltage meter. Excellent for OEM lighting manufacturing, lighting retrofitting, junction boxes, control panels, security & alarm systems, pre-fabricated wiring harnesses, etc. Available in 2, 3, 4, and 5 pole Quick-Splice Disconnectors Quick-Splice Disconnectors feature: Sizes 22-18, 16-12, 12-10 105 degrees C (221 degrees F), 600 volt rating designed for wide applications. Polypropylene Insulation Tin-plated brass connector material for superior conductance Open port type available in size 18-14 T-Taps T-Taps Disconnectors feature: Sizes 22-18, 16-12, 12-10 105 degrees C (221 degrees F), 600 volt rating designed for wide applications. Polypropylene Insulation Tin-plated brass connector material for superior conductance 55

Push-On Partially Insulated Quick-Slides FEMALE NEMA TAB ELECTRICAL INSULATION WIRE RANGE VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.020 x 0.110 (0.5 x 2.8) 10 amperes 300V Vinyl 22-16 0.020 x 0.187 (0.5 x 4.75) 10 amperes 300V Vinyl 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V Heat shrink, Bare, Vinyl 16-14 0.020 x 0.110 (0.5 x 2.8) 15 amperes 300V Vinyl 16-14 0.020 x 0.187 (0.5 x 4.75) 15 amperes 300V Vinyl 16-14 0.020 x 0.205 (0.5 x 5.20) 15 amperes 300V Vinyl 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V Heat shrink, Bare, Vinyl 12-10 0.032 x 0.250 (0.8 x 6.35) 24 amperes 300V Heat shrink, Bare, Vinyl 12-10 0.032 x 0.375 (0.8 x 9.52) 24 amperes 300V vinyl MALE WIRE RANGE NEMA TAB ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.020 x 0.110 (0.5 x 2.8) 10 amperes 300V Vinyl 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V Heat shrink, Bare, Vinyl or Nylon 16-14 0.020 x 0.187 (0.5 x 4.75) 15 amperes 300V Vinyl 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V Heat shrink, Bare, Vinyl 12-10 0.032 x 0.250 (0.8 x 6.35) 24 amperes 300V Heat shrink, Bare, Vinyl or Nylon DOUBLE PUSH ON CONNECTOR UNINSULATED 16-14.250 56

Push-On Fully Insulated Quick-Slides Also Available in a flat side fully insulated FEMALE WIRE RANGE NEMA TAB ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V nylon 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V nylon 12-10 0.032 x 0.250 (0.8 x 6.35) 24 amperes 300V nylon MALE WIRE RANGE NEMA TAB ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V nylon 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V nylon 12-10 0.032 x 0.250 (0.8 x 6.35) 24 amperes 300V nylon Piggy Back WIRE RANGE NEMA TAB ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 0.032 x 0.250 (0.8 x 6.35) 10 amperes 300V nylon 16-14 0.032 x 0.250 (0.8 x 6.35) 15 amperes 300V nylon 57

Rings Bare Heat Shrink, Vinyl and Nylon INSU- LATED WIRE RANGE STUD ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 #4 19 amperes 600V Bare, Vinyl or Nylon 22-16 #6 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 22-16 #8 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 22-16 #10 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 22-16 1/4 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 22-16 5/16 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 22-16 3/8 19 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 #4 27 amperes 600V Bare, Vinyl or Nylon 16-14 #6 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 #8 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 #10 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 1/4 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 5/16 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 16-14 3/8 27 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 #6 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 #8 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 #10 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 1/4 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 5/16 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 3/8 48 amperes 600V Heat Shrink, Bare, Vinyl or Nylon 12-10 1/2 48 amperes 600V Bare, Vinyl or Nylon 58

Lug Rings Bare, Vinyl and Copper Solder WIRE RANGE A.W.G. STUDSIZE INSULATIONMATERIAL 8 #10 Bare, Vinyl and Copper solder tube 8 1/4 Bare and Vinyl 8 5/16 Bare, Vinyl and Copper solder tube 8 3/8 Bare, Vinyl and Copper solder tube 8 1/2 Bare and Vinyl 6 #10 Bare, Vinyl and Copper solder tube 6 1/4 Bare, Vinyl and Copper solder tube 6 5/16 Bare, Vinyl and Copper solder tube 6 3/8 Bare, Vinyl and Copper solder tube 6 1/2 Bare and Vinyl 4 #10 Bare 4 1/4 Bare, Vinyl and Copper solder tube 4 5/16 Bare, Vinyl and Copper solder tube 4 3/8 Bare, Vinyl and Copper solder tube 4 1/2 Bare, Vinyl and Copper solder tube 2 1/4 Bare and Copper solder tube 2 5/16 Bare and Copper solder tube 2 3/8 Bare and Copper solder tube 2 1/2 Bare and Copper solder tube 1 3/8 Copper solder tube 1 1/2 Copper solder tube 1/0 3/8 Bare and Copper solder tube 1/0 1/2 Bare and Copper solder tube 2/0 3/8 Bare and Copper solder tube 2/0 1/2 Bare and Copper solder tube 59

Battery Connectors Quick Disconnect Straight Style Regular Sizes 6, 4, 2, 1, 1/0, 2/0 Flag Style Regular Size 2/0 Left and Right Handed Regular Size 2/0 Splice Connector Regular Sizes 6, 4, 2, 1, 1/0, 2/0 Lead Terminal Regular Sizes 6, 4, 2, 1, 1/0, 2/0, 3/0, 4/0 Marine Terminal Stud Sizes 5/16, 3/8 60

Block Spades (Flanged) WIRE RANGE STUD ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 #6 19 amperes 600V vinyl 22-16 #8 19 amperes 600V vinyl 22-16 #10 19 amperes 600V vinyl 16-14 #6 27 amperes 600V vinyl 16-14 #8 27 amperes 600V vinyl 16-14 #10 27 amperes 600V vinyl Snap Spades WIRE RANGE STUD ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 #6 19 amperes 600V vinyl 22-16 #8 19 amperes 600V vinyl 22-16 #10 19 amperes 600V vinyl 16-14 #6 27 amperes 600V vinyl 16-14 #8 27 amperes 600V vinyl 16-14 #10 27 amperes 600V vinyl 61

Spades (Forks) VINYL INSULATED IRE RANGE STUD ELECTRICAL INSULATION VOLTS A.W.G. SIZE CURRENT MATERIAL 22-16 #6 19 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 22-16 #8 19 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 22-16 #10 19 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 16-14 #6 27 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 16-14 #8 27 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 16-14 #10 27 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 12-10 #8 48 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare 12-10 #10 48 amperes 600V Vinyl, Nylon, Heat Shrink, and Bare Step-Down Connectors Step-Down Butt Connectors are used to join a pair of conductors to a third, all the same size or two conductors of different sizes. WIRE RANGE A.W.G. INSULATION MATERIAL 16-14 to 22-18 Vinyl 12-10 to 16-14 Vinyl 8 to 12-10 Vinyl 62

Square Adhesive-back Cable Tie Mounts Square Mounting Bases: Allows bundles to be attached to specific locations for accurate routing of cable/wires. Four-way tie insertion allows ties to be easily mounted from any of the four sides. Acrylic/Rubber based adhesive backs fastens securely to most flat surfaces. Can provide an additional screw hole which may be used to secure bundles by adhesive, screw, or a combination of both. Manufactured from 100% Nylon 6/6 Natural (code 9) or heat-stabilized black (code 0) CABLE TIES MOUNTING TYPE DIMENSIONS ACCEPTED 4 way adhesive & #4 screw hole 0.75 x 0.75 x 0.21 (19 x 19 x 5.3) up to 0.14 (3.6) 4 way adhesive & #10 screw hole 1.1 x 1.1 x 0.28 (19 x 19 x 5.3) up to 0.19 (4.8) Terminal Blocks SPECIFICATIONS A.W.G. AMP VOLT SCREW SIZE 20-18 20A 600V M2.6 x 5 22-10 30A 600V M3.0 x 6 22-10 35A 600V M3.5 X 7 20-8 50A 600V M4.0 x 9 DIMENSIONS (inches/mm) A B C D E F 3.74 96.2 0.67 17.0 0.57 14.5 0.32 8.0 0.11 2.9 0.11 2.9 4.63 117.0 0.80 20.2 0.67 17.0 0.39 10 0.14 3.6 0.13 3.2 5.54 140.7 0.94 23.8 0.75 19.0 0.48 12.2 0.15 3.8 0.15 3.9 6.22 158.0 1.01 25.6 1.0 25.2 0.53 13.5 0.17 4.3 0.19 4.8 63

U Telecomm Connectors Yellow MAXIMUM INSULATION (O.D.) 1.52 mm 0.060 PIC unfilled 0.7 0.4mm.028.016 22-26 AWG WIDTH PIC filled 0.7 0.4mm.028.016 22-26 AWG Pulp or Paper 0.7 0.4mm.028.016 22-26 AWG Silicone Gel? yes Blue MAXIMUM INSULATION (O.D.) PIC unfilled WIDTH PIC filled Pulp or Paper Silicone Gel? 1.27 mm 0.050 0.7 0.4mm.028.016 0.5 0.4mm.020.016 0.7 0.4mm.028.016 yes Red MAXIMUM INSULATION (O.D.) 1.67 mm 0.066 PIC unfilled 0.9 0.4mm.035.016 19-26 AWG WIDTH PIC filled 0.9 0.4mm.035.016 19-26 AWG 64 Pulp or Paper 0.9 0.4mm.035.016 19-26 AWG Silicone Gel? yes

All Plastic Wire Connectors W I R E WIRE RANGE TEMP. COLOR VOLTAGE* A.W.G. (C/F) yellow 22-16 300V 105 / 221 ivory 22-16 300V 150 / 302 ivory 22-14 600V 105 / 221 Spring Loaded Wire Connectors N U T S WIRE RANGE TEMP. COLOR VOLTAGE* A.W.G. (C/F) grey 22-16 300V 105 / 221 black 22-16 300V 150 / 302 blue 22-14 300V 105 / 221 orange 22-14 600V 105 / 221 orange 22-14 600V 105 / 221 black 22-14 300V 150 / 302 yellow 22-14 600V 105 / 221 red 18-10 600V 105 / 221 Rated 1,000V maximum in lighting fixtures and signs 65

Winged Wire Connectors WIRE RANGE TEMP. COLOR VOLTAGE* A.W.G. (C/F) yellow 18-10 600V 105 / 221 tan 22-8 600V 105 / 221 red 18-8 600V 105 / 221 grey 18-8 600V 105 / 221 blue 14-6 600V 105 / 221 GROUNDING CONNECTOR green 14-10 with built-in through port * Rated 1,000V maximum in lighting fixtures and signs 66

Marker / Identification Cable Ties Self-locking, Marker / Identification cable ties feature: Integrated marker tags enable proper identification when bundling. Manufactured from 100% Nylon 6/6; self-extinguishing 94V-2 Natural operating temperature range of 40 o F (-4 o C) to 185 o F (85 o C) Available in two tag styles: C A B L E T I E S MARKING PAD LENGTH WIDTH MAX BUNDLE DIAMETER MIN TENSILE STRENGTH SIZE 3 7/8 (100) 0.10 (2.5) 3/4 (20) 18 lbs (8 kg) 0.3 x 1 LENGTH WIDTH MARKING PAD MAX BUNDLE DIAMETER MIN TENSILE STRENGTH SIZE 8 5/8 (220) 0.19 (4.8) 1 5/8 (43) 50 lbs (23 kg) 1.1 x 0.5 11 1/2 (300) 0.19 (4.8) 2 3/4 (70) 50 lbs (23 kg) 1.1 x 0.5 14 1/2 (370) 0.19 (4.8) 3 1/2 (88) 50 lbs (23 kg) 1.1 x 0.5 Releasable Cable Ties Self-locking, releasable cable ties feature: Quick decoupling allows for modifications or repairs. Simply press tab at the head to release the lock for reuse. Manufactured from 100% Nylon 6/6; self-extinguishing 94V-2 Natural operating temperature range of 40 o F (-4 o C) to 185 o F (85 o C) LENGTH WIDTH MAX BUNDLE DIAMETER MIN TENSILE STRENGTH 7 7/8 (200) 0.30 (7.6) 2 (50) 50 lbs (23 kg) 11 3/4 (300) 0.30 (7.6) 3 (76) 50 lbs (23 kg) 67

Regular Cable Ties Self-locking cable ties feature: UL Recognized #188715 Meets Military Specification Manufactured from 100% Nylon 6/6 Self-extinguishing 94V-2 Natural operating temperature range of 40 o F (-4 o C) to 185 o F (85 o C) Complete stock in natural (code 9) or UV black (code 0) * These cable ties also come in the following colors: Red (-2), Orange (-3), Yellow (-4), Green (-5), Blue (-6), Gray (-8), Fluorescent Pink (-FP), Fluorescent Orange (-FO), and Fluorescent Yellow (-FY) LENGTH WIDTH MAX BUNDLE MIN TENSILE DIAMETER STRENGTH MIL SPEC 3 1/8 (80) 5/8 (17) Miniature 4 (100) 0.10 7/8 (22 MS3367-4 5 1/2 (140) 1 3/8 (35) 18 LBS 6 3/8 (160) (2.5) 1 9/16 (40) 8 (200) 2 (50) 8 KG 5 7/8 (150) 1 3/8 (35) Intermediate MS3367-5 8 (200) 0.14 2 (50) 12 (300) 3 (77) 40 LBS 14 1/2 (370) (3.6) 4 (102) 18 KG 6 3/8 (160) 1 9/16 (40) Standard 7 3/8 (190) 0.19 1 3/4 (45) MS3367-1 12 (300) 3 (77) 50 LBS MS3367-7 14 1/2 (370) (4.8) 4 (102) MS3367-2 18 (430) 4 1/2 (115) 23 KG 8 (200) 1 15/16 (50) Light Heavy Duty 14 1/2 (370) 0.30 4 (102) MS3367-3 17 3/4 (470) 5 1/5 (132) 120 LBS 29 (730) (7.6) 8 (200) 54 KG MS3367-6 20 3/4 (528) 5 1/2 (140) 24 (609) 7 1/2 (190) Heavy Duty 28 (710) 0.35 8 (200) 32 (812) 9 1/2 (245) 175 LBS 36 (912) (9) 10 1/3 (263) 42 (1070) 12 3/5 (320) 48 (1220) 14 3/8 (365) 79.5 KG 68

Screw Mount Cable Ties Self-locking cable ties feature: Manufactured from 100% Nylon 6/6; self-extinguishing 94V-2 Natural operating temperature range of 40 o F (-4 o C) to 185 o F (85 o C) Natural ( 9) or heat-stabilized black ( 0) Integrated screw mounts do way with the need for separate mounting devices MAX MIN SCREW LENGTH WIDTH BUNDLE TENSILE SIZE DIAMETER STRENGTH 4 3/8 (110) 0.10 (2.5) 3/4 (18) 18 lbs (8 kg) #4 6 1/8 (156) 0.14 (3.6) 1 3/8 (35) 40 lbs (18 kg) #8 8 (205) 0.19 (4.8) 2 (54) 50 lbs (23 kg) #10 11 1/2 (300) 0.19 (4.8) 3 (79) 50 lbs (23 kg) #10 14 1/2 (370) 0.19 (4.8) 4 (102) 50 lbs (23 kg) #10 15 (380) 0.30 (7.6) 4 1/8 (104) 120 lbs (54 kg) 1/4 69

Shrinkable Tubing Polyolefin Flexible Polyolefin Polyolefin heat shrinkable tubing Mil-I-23053/5 Class 1 and 2 (Clear) UL-224 125C VW-1 AMS 3636 3637(Clear) CSA Internal Diameter Expanded I.D. minimum in Recovered I.D. maximum in Recovered wall nominal in inches inches inches 3/64.046.023.016 1/16.063.032.017 3/32.093.046.020 1/8.125.063.020 3/16.187.093.020 1/4.250.125.025 5/16.313.157.025 3/8.375.187.025 1/2.500.250.025 5/8.625.313.025 3/4.750.375.030 1 1.000.500.035 1 1/2 1.500.750.040 2 2.000 1.000.045 3 3.000 1.500.050 4 4.000 2.000.055 Rated for a continuous operating temperature from -55C (-67F) to 135C (275F) and withstands elevated temperatures to 300C (572F) for short periods. Minimum shrink temperature is 121C (250F), temperatures in excess of 175C (347F) may tend to destroy the effectiveness of the tubing. Recovers to 50% of its original diameter when heated. Typical uses include splices, wire bundling, markers, harnessing, stress relief, terminations Offers excellent chemical, corrosion, oil and heat resistance. Very Flexible Polyolefin Polyolefin heat shrinkable tubing Mil-I-23053/5 Class 3 UL-224 125C VW-l AMS 3636 CSA Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/64.046.023.016 1/16.063.031.017 3/32.093.046.020 1/8.125.062.020 3/16.187.093.020 1/4.250.125.025 3/8.375.187.025 1/2.500.250.025 3/4.750.375.030 1 1.000.500.035 1 1/2 1.500.750.040 T U B I N G Used where highly flame-retardant, low shrink temperature insulation is required. The extra flexibility and low shrink temperature (90C) makes it ideal for shrink fit jacketing and insulation of flexible wire bundles. 70

Polyolefin Continued 3 TO 1 Shrink Ratio Flexible Polyolefin Polyolefin heat shrinkable tubing Mil-I-23053/5 UL-224 125C VW-l CSA Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.120.040.024 3/16.187.062.020 1/4.240.080.028 3/8.360.120.031 1/2.480.160.033 3/4.720.240.039 1.945.315.048 1 1/2 1.575.515.050 4 TO 1 Shrink Ratio Flexible Polyolefin Polyolefin heat shrinkable tubing Mil-I-23053/S CL I overexpanded UL-224 12SC VW-I CSA Shrink temperatnre 90C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1 1.260.059 1 1/2 1.5.375.059 2 2.500.059 3 3.750.059 4 4 1.059 Flexible Polyolefin Ground id marker-yellow Green Mil-I-23053/5 Class 1 UL-224 125C VW-I AMS 3636 CSA Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/32.093.046.020 1/8.125.062.020 3/16.187.093.020 1/4.250.125.025 3/8.375.187.025 1/2.500.250.025 3/4.750.375.030 1 1.000.500.035 4 4.000 2.000.055 Shrink temperature of 120C (247F) and an operating temperature of -55C (-67F)to 135C (275F). Uses a dual extrusion of tubing colors (yellow and green) to give a permanence of color and performance,. Used to provide positive identification of ground wires in accordance to international standards Semi-Rigid Polyolefin M23053/6 Class l(b), Class 2 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in 1/8.125.062.020 3/16.187.093.025 1/4.250.125.025 3/8.375.187.030 1/2.500.250.030 3/4.750.375.035 Semi rigid material adds strength to wires and terminations. Suited for wire strain relief applications. 71

Adhesive Lined Shrinkable Dual Wall Crosslinked polyolefin with an internal melting sealant. Mil-I-23053/4 (1/8 1-1 1/2 ) Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.023.038 3/16.187.060.045 1/4.250.080.047 3/8.375.135.050 1/2.500.195.055 3/4.750.313.065 1 1.000.400.075 1 1/4 1.25.500.1 1 1/2 1.5.600.120 2 2.050.750.080 2 3/4 2.750 1..080 3 1/2 3.5 1.18.095 4.7 4.7 1.57.105 Internal sealant melts and provides a moisture-proof seal for encapsulation of wires, splices, breakouts and components. This tubing is especially of value for applications as a moisture barrier in high humidity and corrosive environments. Dual Wall 2X Flexible flame-retardant polyolefin with an internal melting sealant. MiI-I-23053/4 Class 2 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.062.026 3/16.187.093.026 1/4.250.125.030 3/8.375.187.030 1/2.500.250.030 3/4.750.375.035 1 1.000.500.042 1 1/2 1.5.750.047 This material is recommended for applications in environmental conditions which require sealing against moisture or other contaminants. Semi-rigid adhesive lined polyolefin M23053/4 Class 1 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.023.038 3/16.187.060.043 1/4.250.080.047 3/8.375.135.050 1/2.500.195.050 3/4.750.313.065 1 1.000.400.075 Semi rigid material protects from flexing, abrasion and vibration. 72

Adhesive Lined Shrinkable Continued Dual Wall 4X Crosslinked polyolefin with an internal melting sealant. UL224 125C 600V Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 4/1.157.039.040 8/2.315.079.048 12/3.472.118.055 16/4.630.157.071 24/6.945.236.089 32/8 1.260.315.100 This material is recommended for applications in environmental conditions in high humidity and corrosive environments requiring higher shrink ratio. Provides a moisture-proof seal. Over-expanded Semi-rigid Dual Wall UL 224, 600 volts, 125C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1.228.050.047 2.295.065.060 3.429.094.075 4.701.175.095 Both the outer jacket and the adhesive are highly flame retardant. Operating temperature range is 40C to 13SC with a low shrink temperature of 120C. 6X High ratio heavy wall polyolefin Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 750.750.125.123 1300 1.3.220.135 1750 1.75.290.140 2000 2.330.170 2750 2.75.460.190 3500 3.5.673.170 4700 4.7.900.190 Accommodates a large difference in cable and connector size and shapes. 73

Adhesive Lined Shrinkable Continued Heavy Wall Polyolefin tubing with a dual purpose thermoplastic liner M230531l5 Class 1 U/L CSA Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 300.300.100.060 400.400.150.060 500.510.160.090 750.750.220.105 1100 1.1.375.120 1500 1.5.500.140 2000 2.750.155 3000 3 1.250.155 4000 4 1.750.155 Maximum protection for insulating and sealing electrical connections and terminations. Used in most adverse conditions such as direct burial, URD and submersible installations. May be used over lead, steel, aluminum, copper, standard plastic and all elastomeric insulations of power cables, battery cables and over all repair splices. Medium Wall Polyolefin tubing with a dual purpose thermoplastic liner M23053/15 Class 2 Op temp -55C 110C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 750.750.220.080 1100 1.1.375.080 1300 1.3.400.080 1500 1.5.500.080 1700 1.7.500.080 2050 2.05.750.080 2750 2.750 1.080 3500 3.5 1.18.095 4700 4.7 1.57.105 6700 6.7 2.3.110 Suitable for a variety of low voltage electrical and mechanical situations where light weight and flexibility are important. 74

Specialty Tubing Polyvinylchloride PVC - Mil-I-23053/2 Class 2 UL-224 VW-l CSA AMS 3579 105C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/64.046.023.020 1/16.063.031.020 3/32.093.046.025 1/8.125.062.025 3/16.187.093.025 1/4.250.125.025 5/16.312.156.028 3/8.375.187.028 1/2.500.250.028 5/8.625.313.033 3/4.750.375.033 1 1.500.038 1 1/4 1.25.612.043 1 1/2 1.5.750.043 2 2 1.048 3 3 1.5.068 4 4 2.073 Low cost tubing is used for wire splices, diodes, markers, resistors, terminations, CB antennas, and numerous consumer applications. Outstanding dielectric and mechanical properties and is oil and chemical resistant. Neoprene - Mil-I-23053/2 Class 2 UL-224 VW-l CSA AMS 3579 105C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.062.027 3/16.187.093.033 1/4.250.125.035 3/8.375.187.040 1/2.500.250.048 5/8.625.313.052 3/4.750.375.057 7/8.875.437.065 1 1.500.070 1 1/4 1.25.612.087 1 1/2 1.5.750.095 1 3/4 1.75.875.107 2 2 1.110 3 3 1.5.125 Neoprene combined with solvent resistance, abrasion and cut-trough protection make this a popular choice for harness, wire bundling and hydraulic coupling. 75

Specialty Tubing Continued Diesel Resistant Mil-I-23053116 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.062.030 3/16.187.093.035 1/4.250.125.035 3/8.375.187.040 1/2.500.250.048 3/4.750.375.057 1 1.000.5.070 Resistance to aviation and diesel fuels, hydraulic fluids and other chemicals. Viton - modified fluoroelastomer very flexible crosslinked MiI-I-230531l3 MiI-R-46846 Type 3 Class 1C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.125.062.030 3/16.187.093.035 1/4.250.125.035 3/8.375.187.035 1/2.500.250.035 5/8.625.313.042 3/4.750.375.042 7/8.875.438.049 1 1.500.049 1 1/4 1.25.625.055 1 1/2 1.5.750.055 2 2 1.065 Withstands a wide variety of acids, fuels, lubricants, corrosive fluids and solvents. Used in aircraft, aerospace, missile systems and chemical plant applications. Kynar - semi-rigid Polyvinylidene Fluoride Flouroplastic Mil-I-23053/8 UL-224 VW-l CSA AMS 3632 175C Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/64.046.023.010 1/16.063.031.010 3/32.093.046.010 1/8.125.062.010 3/16.187.093.010 1/4.250.125.012 3/8.375.187.012 1/2.500.250.012 3/4.750.375.017 1 1.500.019 1 1/2 1.5.750.020 Used in applications requiring high temperature rating, excellent flame and chemical resistance and cut-through and abrasion Also used for strain relief, insulation of disconnects or component and wire markers. 76

Specialty Tubing Continued Kynar Class 1 and 3 M23053/18 Class 1, 3 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/64.046.023.010 1/16.063.031.010 3/32.093.046.010 1/8.125.062.010 3/16.187.093.010 1/4.250.125.012 3/8.375.187.012 1/2.500.250.012 3/4.750.375.017 1 1.500.019 Class 1 Kynar is used where the properties of Kynar are desirable, but the added benefits of flexibility, clarity, reduced shrink temperature (1 SOC) and continuous lengths are preferred. Class 3 Kynar has the lowest shrink temperature (90C) and greatest flexibility of any Kynar type tubing available. Kynar Class 2 M23053118 Class 2 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/64.046.023.010 1/16.063.031.010 3/32.093.046.010 1/8.125.062.010 3/16.187.093.010 1/4.250.125.012 3/8.375.187.012 1/2.500.250.012 3/4.750.375.017 1 1.500.019 Used where a low profile, abrasion resistant, flexible material is needed. 77

Specialty Tubing Continued FEP HEAT SHRINK 1.3 to 1 M23053/11 cl 1 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 24.031.027.008 22.036.032.008 20.045.039.008 18.060.049.008 16.075.061.009 14.092.072.009 12.115.089.009 10.141.114.010 9.158.124.010 8.180.143.010 7.197.158.011 6.225.180.011 5.248.198.011 4.290.226.011 3.310.249.011 2.365.280.012 1.400.311.012 0.440.349.012 3/8.500.383.015 7/16.580.448.020 1/2.666.510.020 5/8.830.637.025 3/4 1.764.030 7/8 1.170.891.035 1 1.330 1.020.035 1 1/8 1.500 1.145.035 1 1/4 1.666 1.270.035 1 3/8 1.833 1.390.035 1 1/2 2 1.520.035 Temperature rating of -55C (0 200C and shrinks at 290C FEP HEAT SHRINK 1.6 to 1 M23053/11 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 3/32.093.056.008 1/8.125.075.010 3/16.188.115.010 1/4.250.150.010 3/8.375.225.012 1/2.500.300.015 3/4.750.450.020 1 1.600.025 1 1/2 1.5.900.030 2 2 1.200.030 Temperature rating of -55C (0 200C and shrinks at 290C 78

Specialty Tubing Continued TFE - Standard Wall M23053/12/ cl2 AMS 3586 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 30.034.015.009 28.038.018.009 26.046.022.009 24.050.027.012 22.055.032.012 20.060.039.016 19.065.043.016 18.076.049.016 17.085.054.016 16.093.061.016 15.110.067.016 14.120.072.016 13.140.080.016 12.150.089.016 11.170.101.016 10.191.112.016 9.205.124.020 8.240.141.020 7.270.158.020 6.302.178.020 5.320.198.020 4.370.224.020 3.390.249.020 2.430.270.020 1.450.311.020 0.470.347.020 1/8.215.130..020 1/4.410.260.020 5/16.470.329.020 3/8.560.399.025 7/16.655.462.025 1/2.750.524.025 5/8.930.655.030 3/4 1.125.786.035 7/8 1.310.911.035 1 1.5 1.036.035 Ideal material for skin-tight jacketing of items that will be subjected to extremes of temperature, corrosion, moisture, shock, or other extreme conditions. Operating temperature of -100 to 500F. With a shrink temperature of 620F, care must be taken that the item to be covered can withstand this heat as well. 79

Specialty Tubing Continued TFE - Thin Wall M23053/12/ cl3 AMS 3585 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 30.034.015.009 28.038.018.009 26.046.022.009 24.050.027.010 22.055.032.010 20.060.039.012 19.065.043.012 18.076.049.012 17.085.054.012 16.093.061.012 15.110.067.012 14.120.072.012 13.140.080.012 12.150.089.012 11.170.101.012 10.191.112.012 9.205.124.015 8.240.141.015 7.270.158.015 6.302.178.015 5.320.198.015 4.370.224.015 3.390.249.015 2.430.270.015 1.450.311.015 0.470.347.015 1/8.215.130.015 1/4.410.260.015 5/16.470.329.015 3/8.560.399.015 7/16.655.462.018 1/2.750.524.018 5/8.930.655.020 3/4 1.125.786.025 7/8 1.310.911.025 1 1.5 1.036.025 Ideal material for skin-tight jacketing of items that will be subjected to extremes of temperature, corrosion, moisture, shock, or other extreme conditions. Operating temperature of -100 to 500F. With a shrink temperature of 620F, care must be taken that the item to be covered can withstand this heat as well. 80

Specialty Tubing Continued TFE - Light Wall M23053/12 cl4 Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 30.034.015.006 28.038.018.006 26.046.022.006 24.050.027.006 22.055.032.006 20.060.039.006 19.065.043.006 18.076.049.006 17.085.054.006 16.093.061.006 15.110.067.006 14.120.072.008 13.140.080.008 12.150.089.008 11.170.101.008 10.191.112.008 9.205.124.008 8.240.141.008 7.270.158.008 6.302.178.010 5.320.198.010 4.370.224.010 3.390.249.010 2.430.270.010 1.450.311.010 0.470.347.010 Ideal material for skin-tight jacketing of items that will be subjected to extremes of temperature, corrosion, moisture, shock, or other extreme conditions. Operating temperature of -100 to 500F. With a shrink temperature of 620F, care must be taken that the item to be covered can withstand this heat as well. TFE - Thick Wall M23053/12 U/L CSA Internal Diameter Expanded I.D. minimum Recovered I.D. maximum Recovered wall nominal in in inches in inches inches 1/8.166.130.030 3/16.250.193.030 1/4.333.257.030 5/16.415.320.030 3/8.498.383.030 7/16.580.448.030 1/2.666.510.030 5/8.830.637.030 3/4 1.764.040 7/8 1.170.891.045 1 1.330 1.020.050 Ideal material for skin-tight jacketing of items that will be subjected to extremes of temperature, corrosion, moisture, shock, or other extreme conditions. Operating temperature of -100 to 500F. With a shrink temperature of 620F, care must be taken that the item to be covered can withstand this heat as well. 81

Non Shrink Tubing Polyvinylchloride PVC - UL-224 105C AMS 3631 VW-1 CSA Mil-I-631D Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.012 22.027.012 20.034.016 19.038.016 18.042.016 17.047.016 16.053.016 15.059.016 14.066.016 13.076.016 12.085.016 11.095.016 10.106.016 9.118.020 8.133.020 7.148.020 6.166.020 5.186.020 4.208.020 3.234.020 2.263.020 1.294.020 0.330.025 3/16.186.020 1/4.250.020 5/16.313.025 3/8.375.025 7/16.438.025 1/2.500.025 9/16.563.030 5/8.625.030 3/4.750.035 7/8.875.035 1 1.035 1 1/8 1.125.035 1 1/4 1.250.040 1 3/8 1.375.045 1 1/2 1.500.045 1 3/4 1.750.055 2 2.060 2 1/4 2.250.065 2 1/2 2.500.070 Used for internal wiring of electronic and electrical devices, for insulating bare wiring and wire bundling. Resistant to oil, chemicals, solvents, fungi, and is self extinguishing. 82

Non Shrink Tubing Continued Polyvinylchloride PVC Lo-Temp Mil-I-7444 Class I-Types 1, 3 Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.012 22.027.012 20.034.016 19.038.016 18.042.016 17.047.016 16.053.016 15.059.016 14.066.016 13.076.016 12.085.016 11.095.016 10.106.016 9.118.020 8.133.020 7.148.020 6.166.020 5.186.020 4.208.020 3.234.020 2.263.020 1.294.020 0.330.020 3/16.186.020 R313.313.025 R375.375.025 R438.438.025 R500.500.025 R562.562.030 R625.625.030 R750.750.035 R875.875.035 1R00 1.035 1R25 1.25.040 1R50 1.5.045 1R75 1.75.055 2R00 2.060 2R25 2.25.065 2R50 2.5.070 Used for harnessing, cable and conduit installations where low temperatures are encountered. Manufactured to withstand temperatures as low as -70C. 83

Non Shrink Tubing Continued Teflon- Heavy Wall AMS 3653D ASTM D 3295, cl E Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.016 23.026.016 22.028.016 21.032.016 20.034.018 19.038.020 18.042.020 17.047.020 16.053.020 15.059.020 14.066.020 13.076.020 12.085.020 11.095.020 10.106.025 9.118.025 8.133.030 7.148.030 6.166.030 5.186.032 1/16.062.063 1/8.125.063 3/16.187.063 1/4.255.063 5/16.318.063 3/8.381.063 7/16.444.063 1/2.507.063 9/16.562.063 5/8.632.063 3/4.760.063 7/8.885.063 Continuous operating temperature of -78C to 260C. Completely inert to practically all lubricants and solvents and has zero moisture absorption. 84

Non Shrink Tubing Continued Teflon- Standard Wall AMS 3653, ASTM D 3295, cl C, Mil-I-22129, UL 224 600V 200C CSA Internal Diameter Nominal I.D. in inches Wall nominal in inches 30.012.009 28.015.009 26.018.009 24.022.012 23.026.012 22.028.012 21.032.012 20.034.016 19.038.016 18.042.016 17.047.016 16.053.016 15.059.016 14.066.016 13.076.016 12.085.016 11.095.016 10.106.016 9.118.020 8.133.020 7.148.020 6.166.020 5.186.020 4.208.020 3.234.020 2.263.020 1.294.020 0.330.020 1/8.125.020 3/16.187.020 1/4.255.020 5/16.318.020 3/8.381.025 7/16.444.025 1/2.507.025 5/8.632.030 3/4.760.035 7/8.885.035 1 1.01.035 Continuous operating temperature of -78C to 260C. Completely inert to practically all lubricants and solvents and has zero moisture absorption. 85

Non Shrink Tubing Continued Teflon- Thin Wall AMS 3655, ASTM D 3295, cl B, UL 224 300V 200C CSA Internal Diameter Nominal I.D. in inches Wall nominal in inches 30.012.009 28.015.009 26.018.009 24.022.010 23.026.010 22.028.010 21.032.010 20.034.012 19.038.012 18.042.012 17.047.012 16.053.012 15.059.012 14.066.012 13.076.012 12.085.012 11.095.012 10.106.012 9.118.015 8.133.015 7.148.015 6.166.015 5.186.015 4.208.015 3.234.015 2.263.015 1.294.015 0.330.015 1/8.125.015 3/16.187.015 1/4.255.015 5/16.318.015 3/8.381.020 7/16.444.020 1/2.507.020 9/16.562.020 5/8.632.025 3/4.760.030 Continuous operating temperature of -78C to 260C. Completely inert to practically all lubricants and solvents and has zero moisture absorption. 86

Non Shrink Tubing Continued Teflon- Light Wall AMS 3654A, ASTM D 3295, cl A, UL 224 150V 200C Internal Diameter Nominal I.D. in inches Wall nominal in inches 32.010.005 30.012.006 28.015.006 26.018.006 24.022.006 23.026.006 22.028.006 21.032.006 20.034.006 19.038.006 18.042.006 17.047.006 16.053.006 15.059.006 14.066.008 13.076.008 12.085.008 11.095.008 10.106.008 9.118.008 8.133.008 7.148.008 6.166.010 5.186.010 4.208.010 3.234.010 2.263.010 1.294.010 0.330.012 1/8.125.008 3/16.187.010 1/4.255.010 5/16.318.012 3/8.381.015 7/16.444.018 1/2.507.018 5/8.632.020 3/4.760.020 Continuous operating temperature of -78C to 260C. Completely inert to practically all lubricants and solvents and has zero moisture absorption. 87

Non Shrink Tubing Continued Teflon- Industrial Wall ASTMD 3295, AMS 3653D Internal Diameter Nominal I.D. in inches Wall nominal in inches 1/32.031.015 1/16.062.030 3/32.093.030 1/8.125.030 3/16.187.030 1/4.255.030 5/16.318.030 3/8.381.030 7/16.444.030 1/2.507.030 5/8.632.030 3/4.760.040 7/8.885.045 1 1.01.050 Continuous operating temperature of -78C to 260C. Completely inert to practically all lubricants and solvents and has zero moisture absorption. FEP- Industrial Wall ASTM D 2116 Internal Diameter Nominal I.D. in inches Wall nominal in inches 1/32.031.015 1/16.063.030 3/32.094.030 1/8.125.030 3/16.187.030 1/4.250.030 5/16.313.030 3/8.375.030 7/16.438.030 1/2.500.030 5/8.625.030 3/4.750.040 7/8.875.045 1 1.00.050 1 1/4 1.25.040 1 1/2 1.50.040 Has chemical inertness, excellent dielectric strength, non aging characteristics and anti stick properties. FDA approved. 88

Non Shrink Tubing Continued FEP- Standard Wall ASTM D 2116 UL-224 Internal Diameter Nominal I.D. in inches Wall nominal in inches 30.012.009 28.015.009 26.018.009 24.022.012 23.026.012 22.028.012 21.032.012 20.034.016 19.038.016 18.042.016 17.047.016 16.053.016 15.059.016 14.066.016 13.076.016 12.085.016 11.095.016 10.106.016 9.118.020 8.133.020 7.148.020 6.166.020 5.186.020 4.208.020 3.234.020 2.263.020 1.294.020 0.330.020 1/8.125.020 3/16.187.020 1/4.250.020 5/16.313.020 3/8.375.025 7/16.438.025 1/2.500.025 5/8.625.035 3/4.750.030 7/8.875.035 Has chemical inertness, excellent dielectric strength, non aging characteristics and anti stick properties. FDA approved. 89

Non Shrink Tubing Continued FEP- Thin Wall ASTM D 2116 UL-224 Internal Diameter Nominal I.D. in inches Wall nominal in inches 30.012.009 28.015.009 26.018.009 24.022.010 23.026.010 22.028.010 21.032.010 20.034.012 19.038.012 18.042.012 17.047.012 16.053.012 15.059.012 14.066.012 13.076.012 12.085.012 11.095.012 10.106.012 9.118.015 8.133.015 7.148.015 6.166.015 5.186.015 4.208.015 3.234.015 2.263.015 1.294.015 0.330.015 1/8.125.015 3/16.187.015 1/4.250.015 5/16.313.015 3/8.375.015 7/16.438.018 1/2.500.018 5/8.625.020 3/4.750.025 Has chemical inertness, excellent dielectric strength, non aging characteristics and anti stick properties. FDA approved. 90

Non Shrink Tubing Continued FEP- Light Wall ASTM D 2116 UL-224 Internal Diameter Nominal I.D. in inches Wall nominal in inches 30.012.006 28.015.006 26.018.006 24.022.006 23.026.006 22.028.006 21.032.006 20.034.006 19.038.006 18.042.006 17.047.006 16.053.006 15.059.006 14.066.008 13.076.008 12.085.008 11.095.008 10.106.008 9.118.008 8.133.008 7.148.008 6.166.010 5.186.010 4.208.010 3.234.010 2.263.010 1.294.010 0.330.012 1/8.125.008 3/16.187.010 1/4.250.010 5/16.313.012 3/8.375.015 7/16.438.018 1/2.500.018 5/8.625.020 3/4.750.020 Has chemical inertness, excellent dielectric strength, non aging characteristics and anti stick properties. FDA approved. 91

Non Shrink Tubing Continued FEP- Heavy Wall ASTM D 2116 Internal Diameter Nominal I.D. in inches Wall nominal in inches 1/16.063.063 1/8.125.063 3/16.187.063 1/4.250.063 5/16.313.063 3/8.375.063 7/16.438.063 1/2.500.063 5/8.625.063 3/4.750.063 7/8.875.063 1 1.00.063 1 1/4 1.25.063 1 1/2 1.50.063 2 2.00.063 Has chemical inertness, excellent dielectric strength, non aging characteristics and anti stick properties. FDA approved. CXpando-GP, CXpando-FR ASTMD-876, ASTMD-570, UL 224 Internal Diameter Nominal I.D. in inches Size range in inches 1/8.125 3/32 1/8 1/4.250 1/8 3/8 3/8.375 1/4 5/8 1/2.500 1/4 3/4 3/4.750 1/2 1 1/4 1 1/4 1.25 7/8 1 3/8 1 1/2 1.50 1 1/4 2 2/3 Expands its size to form a snug fitting cover that adjusts to irregular shapes and contours providing abrasion resistance and protection. Criss-cross tracer for ease of identification. Spiral Wrap Polyethelene Internal Diameter Bundle Range Wall nominal in inches 1/8 1/16 1/4.032 3/16 1/8 1.032 1/4 3/16-2.035 3/8 5/16 3.052 1/2 3/8 4.052 5/8 5/8 4 1/2.052 3/4 3/4 5.065 1 1 7.095 Spirally cut for wrapping multiple lines into one manageable bundle while protecting against wear and damage. A single line can be pulled from the bundle at any point and direction which allows for great versatility and flexibility in harnessing multiline cables. 92

Non Shrink Tubing Continued Heat Treated Fiberglass Mil-Y-1140 U VW-l Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.030 22.027.030 20.034.030 18.042.030 17.047.030 16.053.030 15.059.030 14.066.045 13.076.045 12.085.045 11.095.045 10.106.045 9.118.045 8.133.045 6.166.045 5.186.045 4.208.045 3.234.045 2.263.055 1.294.055 0.330.055 3/8.387.055 7/16.450.065 1/2.512.065 5/8.640.065 3/4.768.075 7/8.893.075 1 1.018.075 Designed for applications up to 650C. Material is heat treated to remove all organic material and to render the glass braid fray-resistant. 93

Non Shrink Tubing Continued Vinyl Coated Fiberglass MiI-I-3l9012 U VW-l Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.030 22.027.030 20.034.030 18.042.030 17.047.030 16.053.030 15.059.030 14.066.045 13.076.045 12.085.045 11.095.045 10.106.045 9.118.045 8.133.045 6.166.045 5.186.045 4.208.045 3.234.045 2.263.055 1.294.055 0.330.055 3/8.387.055 7/16.450.065 1/2.512.065 5/8.640.065 3/4.768.075 7/8.893.075 1 1.018.075 Capable of being pushed back, expanded, stretched, flattened, bent into any shape desired or knotted without any loss of dielectric strength or stability. 94

Non Shrink Tubing Continued Acrylic Coated Fiberglass MiI-I-3J90/3 U VW-l Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.030 22.027.030 20.034.030 18.042.030 17.047.030 16.053.030 15.059.030 14.066.045 13.076.045 12.085.045 11.095.045 10.106.045 9.118.045 8.133.045 6.166.045 5.186.045 4.208.045 3.234.045 2.263.055 1.294.055 0.330.055 3/8.387.055 7/16.450.065 1/2.512.065 5/8.640.065 3/4.768.075 7/8.893.075 1 1.018.075 Recommended for applications requiring continuous operating temperatures to 155C. Excellent cut-through resistance and compatibility with most varnishes, resins and wire enamels. 95

Non Shrink Tubing Continued Silicone Rubber Coated Fiberglass MiI-I-3190/6 U VW-l Internal Diameter Nominal I.D. in inches Wall nominal in inches 24.022.030 22.027.030 20.034.030 18.042.030 17.047.030 16.053.030 15.059.030 14.066.045 13.076.045 12.085.045 11.095.045 10.106.045 9.118.045 8.133.045 6.166.045 5.186.045 4.208.045 3.234.045 2.263.055 1.294.055 0.330.055 3/8.387.055 7/16.450.065 1/2.512.065 5/8.640.065 3/4.768.075 7/8.893.075 1 1.018.075 Unaffected by temperatures to +200C and retains flexibility as low as -70C. Resistance to ozone, corona, radiation, moisture, compression set, weathering fungus, and chemical attack. 96

Sleeving Sleeving PVC Non-shrink Multi-purpose Non-shrinkable PVC Sleeving (-20C to 105C) UL224 VW-1 and CSA OFT, MIL-DTL-631D Grade C QPL Approved S L E E V I N G Size/AWG Nominal Inner Diameter in Inches Nominal Wall in Inches 24 0.022 0.012 22 0.027 0.012 20 0.034 0.016 19 0.038 0.016 18 0.042 0.016 17 0.047 0.016 16 0.053 0.016 15 0.059 0.016 14 0.066 0.016 13 0.076 0.016 12 0.085 0.016 11 0.095 0.016 10 0.106 0.016 9 0.118 0.020 8 0.133 0.020 7 0.148 0.020 6 0.166 0.020 5 0.186 0.020 4 0.208 0.020 3 0.234 0.020 1/4 0.250 0.020 2 0.263 0.020 1 0.294 0.020 5/16 0.313 0.025 0 0.330 0.025 3/8 0.375 0.025 7/16 0.438 0.025 1/2 0.500 0.025 9/16 0.563 0.030 5/8 0.625 0.030 3/4 0.750 0.035 7/8 0.875 0.035 1 1.000 0.035 1 1/8 1.125 0.035 1 1/4 1.250 0.040 1 3/8 1.375 0.045 1 1/2 1.500 0.045 1 3/4 1.750 0.055 2 2.000 0.060 2 1/4 2.250 0.065 2 1/2 2.500 0.070 Used in high dielectric and flexible applications to protect against chafing exposure to most chemicals, oils and acids..032 wall also available. 97

Loom Loom Black/Poly Ford Black, Slit Polyethylene (-40C) (95C 105C Intermittent Use) (90C Continuous Use) Diameter in Inches Weight in lbs per 1000 ft 1/8 5.0 1/4 8.0 3/8 14.5 1/2 21.0 5/8 27.0 3/4 32.0 1 40.0 1 1/16 43.0 1 1/4 50.0 1 1/2 61.0 1 5/8 67.0 1 7/8 76.0 2 99.0 Used to hold groups of wire in position and provides protection against abrasion, crushing, gasoline, oil and many chemicals. Meets Ford specs. Loom Black/Nylon Ford Black, Slit Nylon with Gray Stripe (-40C) (125C 190C Intermittent Use) (115C Continuous Use) Diameter in Inches Weight in lbs per 1000 ft 1/8 5.0 1/4 8.0 3/8 14.5 1/2 21.0 5/8 27.0 3/4 32.0 1 40.0 1 1/16 43.0 1 1/4 50.0 1 1/2 61.0 1 5/8 67.0 1 7/8 76.0 2 99.0 L O O M Used to hold groups of wire in position and provides protection against abrasion, crushing, gasoline, oil and many chemicals. Meets Ford specs. 98

Loom Continued Loom Black/Poly Packard/GM Black, Slit Polyethylene (-40C) (95C 105C Intermittent Use) (90C Continuous Use) Common Reference Weight in lbs per 1000 ft 1/4 8.0 5/16 13.5 3/8 14.5 1/2 21.0 5/8 27.0 3/4 32.0 7/8 36.0 1 40.0 1 1/5 44.0 Used to hold groups of wire in position and provides protection against abrasion, crushing, gasoline, oil and many chemicals. Meets Delphi, Packard Electric s specs. Loom Black/Nylon Packard/GM Black, Slit Nylon with Gray Stripe (-40C) (125C 190C Intermittent Use) (115C Continuous Use) Diameter in Inches Weight in lbs per 1000 ft 1/4 8.0 5/16 13.5 3/8 14.5 1/2 21.0 5/8 27.0 3/4 32.0 7/8 36.0 1 40.0 1 1/5 44.0 Used to hold groups of wire in position and provides protection against abrasion, crushing, gasoline, oil and many chemicals. Meets Delphi, Packard Electric s specs. Loom Clamps 1/8 1 1/4 1 1/8 3/8 1 1/4 1/2 1 3/8 5/8 1 1/2 3/4 1 3/4 7/8 99

All Weather PVC Electrical Tape Premium all weather tape. Cold weather applications from 8 F (-18 C) and continuous temperatures up to 220 F (105 C). Conforms to irregular surfaces for moisture tight electrical protection. U.L. Electrical Tape Made of soft polyvinyl, 7 mils thick. Dielectric strength of 8,000 volts per thickness. Conforms to the contour of wire or loom with 175% elongation Excellent adhesive qualities in all weather. Tape rated 17 lbs. tensile strength, Rated up to 600 volts and maximum temperature 176 F (80 C). Available in assorted colors. Cloth Duct Tape Self sticking cloth tape adheres firmly to paper, wood or any clean surface. Non hygroscopic, flame resistant, water proof, Silver color,. Industrial Grade. Rolls are 2 wide; 60 yards long Double Stick Tape Will securely hold trailer panels to frame during attaching. Rolls are 3/4 wide, 216 feet long. Clear Carton Tape General purpose box sealing, clear polypropylene. Available in 110 yd, 2 wide rolls. Thread Seal Tape MIL-T-27730A Lubricates and seals any threaded application. Rolls are 1/2 wide; 520 inches long. A C C E S S O R I E S 100

Fuses ATC Standard Blade Fuse Amps Color 3 Purple 4 Pink 5 Tan 7.5 Brown 10 Red 15 Blue 20 Yellow 25 Clear 30 Green 40 Orange ATC Mini Blade Fuse Amps Color 2 Gray 3 Purple 4 Pink 5 Tan 7.5 Brown 10 Red 15 Blue 20 Yellow 25 Clear 30 Green ATC Maxi Blade Fuse Amps Color 20 Yellow 30 Green 40 Orange 50 Red 60 Blue AGC Glass Fuse Amps 5 6 7.5 10 15 20 25 30 101

Fuses Fuse Taps Amps Mini Blade Glass ATC Breakers Amps 10 15 20 25 30 FMX Fuse Amps Color 20 Blue 30 Pink 40 Green 50 Red 60 Yellow Fuse Puller 102

Fuse Holders Standard Fuse Holder 12 Gauge Wire Mini Fuse Holder 14 Gauge Wire Maxi Fuse Holder 8 Gauge Wire Water Resistant Fuse Holder Standard and Mini Fuses AGC In Line Glass Fuse Holder Maxi Mount Style Fuse Holder Mini Low Profile Holder Stackable Fuse Holder Standard and Mini Fuses 103

Tools An efficient hand tool for fastening cable ties. Tighten and cut off excessive length in a single, simple action. Adjustable tension control ensures accuracy for different tensile strengths. Designed for ties up to 50 lbs (0.19 widths). An affordable, 4 way crimping/stripping tool designed for use with 22-10 AWG terminal and connectors. This tool can be used with crimp items, and features color coded crimp teeth and AWG-numbered wire strippers for fast and accurate crimping and stripping. 8 total length. Designed for heavy-duty ties of 120+lb tensile strength. Constructed of 100% metal, this durable hand tool will tighten and cut off excessive length. Heavy-duty ties are securely fastened. Wire connector sockets attach to a standard 1/4 hexbit of conventional power tools, allowing for quick twist-on fastening of winged and spring-wired wire connectors. No more laborious manual twisting by hand! Sockets (left to right) available for A high quality crimping tool, specifically designed for use with UR, UY, and UB telecom connectors. Features parallel crimping action at point of contact for the most secure crimp for these telecom connections. Also suitable for use with crimp terminals. 5 1/2 total length. G, B, O, HTG, HTO O-F, Y, R 11, 12, 13, 15, 99 104

Trailer Parts Flat Molded Trailer Connections Connector Type 2 wire Male and Female12" and 48" 3 wire Male and Female12" and 48" 4 wire Male and Female12" and 48" Metal and Plastic Non-Molded Trailer Connectors Connector Type 4 wire Male and Female 6 wire Male and Female 7 wire Male and Female 7 wire RV Male and Female 7 wire RV Plastic Male and Female 105

Trailer Adaptors Connector Type 6 wire to 4 flat 7 wire to 6 round 7 wire to 4 flat 7 wire male to 5 flat female Frame Clips 106

Services Assemblies If you need assembly work done to turn your wire into working parts, let ADI do it for you. We have the ability to cut and strip wire to custom specifications, add terminals to the ends, solder dip, and create harness assemblies. We have the ability to take your drawing and sample and turn it into a delivered, ready-to-use product for your needs. Bonding S E R V I C E S At ADI we have custom bonding machines that use a heat process to bind together PVC wires. These runs can be done in any color and size combinations within approximately one inch in width. We can also run them in 500-foot quantities or more. Our bonding process allows our wire to be split backward, leaving a full jacket of insulation in tact. We use a thermal process on our machines; no overcoat process is used, keeping the original factory O.D.. Dyeing At ADI we have the ability to change the color of PVC wire to meet your needs. If there is a special shade of color you need to complete a specific project, ADI can color it for you. Through our dye process, we can widen the spectrum of colors available above and beyond that of factory wire. Also, if your company discontinues a certain color of wire, and changing it to another color would allow it to still be used, let us dye it for you. We have a collection of inks that can turn the color of one wire to another. Just tell us what color you have, and we can use our color change hierarchy scale to give you options on how to recolor the wire. Printing ADI has the ability to print any letters on your wire for custom identification. If you want wires labeled with instructions, locations, or your company name, we can do it for you. Our ink jet printing machine can print in many colors and sizes to meet your needs. We will also print in quantities of 500 ft. or more. Striping We have two types of striping machines at ADI: spiral and parallel. Our spiral striping machine can put between one and three stripes per pass on the wire in a wide variety of colors. Our parallel striping machine can put one or two linear stripes on wire also in a variety of colors. We will also stripe in quantities of 500 ft. or more. All striping can be used to further distinguish wires for identification purposes. Battery Cables If you need Battery Cable assembly work done let ADI do it for you. We have the ability to cut and strip wire to custom specifications, add terminals to the ends, solder dip, and create battery cable assemblies. We have the ability to turn it into a delivered, ready-to-use product for your needs. We use a press to ensure our battery cable ends are crimped secure and ready for long-term use. 107

Specialty products Just because we do not have something listed, do not be afraid to ask us for special products. We enjoy an extensive supplier list, as well as strong contacts throughout the industry that have enabled us to meet the needs of our customers as they arise. Give us a try, and see if we can do the legwork for you. Please make any requests by calling our office at 1-800-521-6001. S P E C I A L I T Y P R O D U C T S 108

L I N E C A R D UL STYLES 1007, 1011, 1013, 1015, 1028, 1032, 1056, 1060, 1061, 1180, 1213, 1230, 1231, 1232, 1275, 1276, 1283, 1284, 1316, 1329, 1371, 1422, 1423, 1429, 1430, 1452, 1483, 1509, 1569, 1581, 2464, 2576, 2598, 3071, 3074, 3075, 3125, 3173, 3182, 3191, 3192, 3193, 3231, 3239, 3257, 3290, 3321, 3340, 3374, 3499, 5288, 5107, Bonded Wire Battery Cable Assemblies Boat Cable Duplex Primary Wire TWP,GPT,HDT Cross-Link TXL,GXL,SXL Brake Cable Marine Military Hook-Up Wire (MIL-W, B, C, D) Rip Cord Trailer Cable Battery Cable (STT,SGT,SGX,STX) Loom Speaker Wire 1-800-521-6001 Fax 620-431-4079 www.adiwire.com Building Wire (TFFN, TF, TW, TEWN, TFF, THW, TWN, TFN, SE, THHN-THWN, XHHW-2, RHW-2) Bus Drop Cable Coaxial Cable Communication & Instrumentation Control Cable Utility Cable Cordset Products Diesel Locomotive Cable (DLO) Drill Cord (Remote) (MSHA) Equipment Wire (TEW) Machine Tool Wire (MTW) Fixture Wire (TFF) Appliance Wire (AWM) Festoon Cable Flexible Cord (SPT, SPT-1-3) Jumper Cable Motor Lead Wire (SRML) Magnet Crane Cable 109 516 W Cherry Chanute, KS 66720 Mine Power (MP-GC) Welding Cable Low Energy Circuit Cable Portable Cord (SOOW, SJOOW, SOW, SJ, STOW, SJTOW, SVT, SJT, STO, SVO, SEOW, W, SEOOW, ST,G-GC, EPDM, MP, SJEOOW, SJTOOW, Thermostat) Airport Lighting Cable Power Cable TelcoFlex Glass Braid & Silicone Security Cable Plenum Cable SDN Small Diameter Control Cable Shovel Cable Entertainment & Stage Cable (SC) Switch Board Wire (SIS) Telecommunications Cable Telephone Cable Tray Cable Hypalon Power Cable XL-40 Bare Copper Fire Power Cable Wire Assemblies Terminals Wire Tools & Accessories Cable Ties Fuses Trailer Lights Pigtails Connectors Quick Splices Tape Ink & Dye Shrink Tube Trailer Connectors Audio Cable Computer Cable Computer Parts

Contact Us ADI, Inc. 516 W. Cherry Street Chanute, KS 66720 Toll-free: 1-800-521-6001 Local:620-431-4078 Fax: 620-431-4079 General: adi@adiwire.com Sales: sales@adiwire.com 110