KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Similar documents
Basic Principles and Operation of Transformer

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Power Transformers Basics

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Transformer Protection

Transformer Factory Testing

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Introduction. Centrado leading-edge transformer. Introduction

Substation Preventive Maintenance

7. INSPECTION AND TEST PROCEDURES

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Basic principles and operation of a transformer

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Hands-On Transformer Testing and Maintenance

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

HOW TO SAFE GUARD THE TRANSFORMER..???

Transformers handling and transport

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

~=E.i!=h. Pre-certification Transformers

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

(2) New Standard IEEE P (3) Core : (4) Windings :

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

1ZSC AAJ en, Rev. 1. Vacuum on-load tap-changers, type VUBB Technical guide

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Curve accuracy (enough data points to be statistically significant): See Attachment B.

FIELD ELECTRICAL TESTING SPX TRANSFORMER SOLUTIONS, INC.

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

Liquid-Filled Transformers

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

DISTRIBUTION TRANSFORMERS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IVE(TY) Department of Engineering. Electrical Machines 1. Electrical Machines 1. Hour 13. slide 1

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

General Description & Features Selection Charts Definition of Terms... 42

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Industrial Electrician Level 3

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Transformer Engineering

OIL-IMMERSED ARC-SUPPRESSION COILS

K Factor Power Transformers

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Preface...x Chapter 1 Electrical Fundamentals

POWER TRANSFORMERS CATALOGUE

Distribution and Power Transformers

Generator Advanced Concepts

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Transformers: Basics, Maintenance, and Diagnostics

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

About us. Vision. To lead our field in innovation, quality and customer service.

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

SECTION TRANSFORMERS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

CHAPTER 4. Distribution Transformers

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

Protection of Electrical Networks. Christophe Prévé

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Variable Transformers Product Design & Engineering Data

Electrical Machines I : Transformers

TRANSFORMERS INTRODUCTION

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

Distribution/Substation Transformer

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

INTERPLANT STANDARD - STEEL INDUSTRY CODE OF PRACTICE FOR TESTING & COMMISSIONING OF TRANSFORMERS AND RELATED SWITCHGEARS

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Load Isolation Transformers

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

3. COMBINED TRANSFORMERS Oil-paper insulation

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Please use the Q & A utility to ask us any questions concerning the material being presented.

ISSN: [IDSTM-18] Impact Factor: 5.164

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Problems connected with Commissioning of Power Transformers

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

SECTION VI TECHNICAL SCHEDULES

Power transformers for Network, Rectifiers, Furnace

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Transcription:

KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current. Auto-Transformer A transformer which has only one winding per phase, part of which is common to both primary and secondary circuits. BIL - Basic Impulse Level is means to express the ability of the insulation system to withstand high voltage surges Buhholz Relay A gas operated Relay used in Conservator Mounted Transformer Core Loss It is the electric loss in a transformer caused by magnetization of the core. They sometimes are referred to as no-load losses because they exist whenever the primary side of the transformer is energized, regardless of whether there is a load on the transformer. It has two major components Eddy Current Loss and Hysteresis Loss. Core Saturation Condition that occurs when a transformer core has reached maximum magnetic strength. Current Transformer: A transformer designed have its primary winding connected in the series with the circuit and used for transforming current to a value suitable for measurement or control. Delta ( ) It refers to a standard 3-phase connection in which each phase winding is connected in series t form a closed loop Drain Valve Fixed normally at the bottom of the tank used mainly for draining of the oil for sampling or filtration Exciting Current (No-Load Current) Exciting current is nothing but No load Current that which flows in any winding used to excite the transformer when all other windings are open circuit. Frequency Designates the number of times that polarity alternates from positive to Negative such as 50 cycles as per second (50Hz) is the term used to measure AC frequency in cycles per second.

Harmonic Distortion- Non-linear distortion (due to non linear load) in the output current wave from when the input is sinusoidal. Total the square root of the sum of the squares of all harmonic current present in the load, excluding the fundamental frequency (50 or 60Hz). Usually expressed as a percent of the fundamental Hi Pot Test (Power Frequency Test) A standard dielectric test to check insulating materials and clearances between winding and ground/neutral Impedance Forces, including resistance and capacitive or inductive reactance, which resist current flow in AC circuits. The unit of impedance is Ohm. Inrush Current A brief and momentary surge of current through the transformer, due to residual flux, experienced at the instant the transformer is energized. Linear Loads Loads where the current waveform conforms to that of the applied voltage, or loads where a change in current is directly proportional to a change in applied voltage. For example: resistance heating, incandescent lighting, water heater Load Losses There are the losses in a transformer which are incident to load carrying. Load losses include l_r loss in the winding due to load current, stray loss due to stray fluxes in the winding,core, clamps, etc. and to circulating currents (is any), in parallel winding No-Load Losses Losses incurred when a transformer is excited but without a load connected to the secondary. These includes core loss & dielectric loss, Non-Linear Loads Loads where the current waveform does not conform to that of the applied voltage, or where a change in current is not proportional to change in applied voltage. For example: computer power supplies, motor drive, fluorescent lighting. OIL Level Gauge To indicate the oil level in the transformer. It shall be a plain level gauge or magnetic oil level gauge or oil view finder. OTI - (Normally Top) Oil Temperature Indicator to measure the oil temperature prevailing at the top level Polarity A designation of the relative instantaneous direction of the current in a secondary lead as compared with a primary lead. Power factor It is the relation of the watts to volt-amps in an electrical circuit PRV Pressure Relief Valve a devise to release the excess pressure from the transformer tank Primary Winding- The winding that is directly connected to the input power

Ratio (Voltage Ratio) a reference to either the primary to secondary winding turn ratio or to the voltage ratio of the transformer Rated Power - The total output power available from all secondary winding, expressed in Volt amperes (VA) or Kilo volt ampere (KVA). It is load that a transformer can handle indefinitely without exceeding the specified temperature rise. Reactor A devise for introducing inductive reactance into a circuit. Rectifier Transformer A transformer designed to supply AC input to a rectifier to obtain the desired DC output and have the ability to withstand the heating effects caused by rectifier commutation or ripple. Scott Connection A transformer connection usually used to get a 2-phase output form the secondary of a transformer with a 3-phase input to the primary or vice versa Step Down Transformer - A transformer in which the high voltage winding is connected to the input or power source and the low voltage winding is connected to the output load (lower voltage on the output) Step Up Transformer A transformer in which the low voltage winding is connected to the input or power source and the low voltage winding is connected to the output load (higher voltage on the output) Secondary Winding The winding supplying the output voltage to the load Silica gel Breather Natural / Synthetic gel used in the breather to absorb the moisture of incoming air passing through the breather. Used normally in Conservator Mounted Transformer. Used normally in Conservator Mounted Transformer. Tap A connection provide in a transformer winding which has the effect of changing the nominal voltage ratio in the transformer. The taps are usually placed on the high voltage winding to compensate for high or low voltage conditions found on the low voltage output side. Temperature Rise The additional maximum heat above ambient temperature that the transformer itself will generate in the normal course of operation. Top Filling Valve - Fixed at the top cover of the transformer used mainly for oil filling. Volts - The practical unit of Voltage measured between two terminals Voltage Regulation It is the measurement how well a transformer can maintain constant secondary voltage given a constant primary voltage at wide variance in load current. The lower the percentage, the more stable the secondary voltage.

Regulation in Percentage: E no load E full load x 100 E full load Voltage Transformer : A transformer that is designed to have its primary winding connected parallel with a circuit and used for transforming voltage to a value suitable for measurement or control. WTI Winding Temperature Indicator a devise to measure the temperature at the winding Wye (Star Connection Y) A 3-phase connection in which similar ends of each phase winding are connected together at a common point which forma the electrical neutral grounded. It is also called Star Connection. In Star Connection Line Current Line Voltage = Phase Current = 3 x Phase Voltage In Delta Connection Line Current Line Voltage Power phases) = 3 x Phase Current = Phase Voltage : 3 x Line Voltage x Line Current x Power Factor (for three Type of Transformer Cooling: ONAN: Oil Natural Air Natural Oil inside the transformer tank cooled naturally and Transformer externally cooled by Nature. ONAF: Oil Natural Air Forced Oil inside the transformer tank cooled naturally but Transformer externally cooled by the accessories like Fan etc. OFAF : Oil Forced Air Forced Oil inside the transformer tank forced cooled by using external heat exchanger and transformer externally cooled by the accessories like Fan..etc ODAF: As same of OFAF but with directed oil flow.ofwe : Oil Forced Water Forced Oil inside the transformer tank forced cooled by using external heat exchanger and the heat exchanger is externally cooled by water circulation

Voltage Class in KV 11/0.433 33/0.433 33/11 with HV and LV cable box and OCTC 33/11 KV with MR OLTC 11/0.433 KV-DEWA package sub station *11/0.433 KV package sub station + Housing KVA L mm W mm H mm Weight Kg OIL Liter Full Load HV Current Full Load LV Current Z% as IEC 25 950 650 1170 325 110 1.31 33 50 1000 720 1250 500 135 2.62 67 100 1175 1050 1320 700 185 5.25 133 200 1400 1300 1600 1150 300 10.50 267 4 315 1500 1300 1800 1450 365 16.53 420 500 2000 1500 2100 2050 450 26.24 667 750 2200 1650 2250 2450 650 39.36 1000 1000 2450 1700 2350 3500 980 52.48 1333 5 1250 2550 1800 2400 3800 1100 65.60 1667 1600 2650 1850 2500 4000 1200 83.97 2133 2000 2750 2450 2600 4600 1400 104.96 2667 6 2500 2850 2550 2700 6500 1850 131.20 3334 200 1540 1060 1880 1400 500 3.49 267 315 1640 1150 2000 1750 650 5.50 420 4 500 1800 1420 2240 2500 800 8.73 667 750 2120 1770 2400 2850 900 13.09 1000 1000 2500 1850 2500 3800 1200 17.45 1333 5 1250 2550 2000 2500 4500 1350 21.81 1667 1600 2650 2200 2650 5000 1500 27.92 2133 2000 2700 2800 2700 6000 1600 34.90 2667 6 2500 2750 2900 2900 8000 2500 43.63 3334 3150 2900 2700 3000 9000 2200 55 165 5000 3150 2800 3200 12500 2800 87.50 262 7 6300 3250 3000 3300 16000 3500 110 331 7500 3350 3300 3500 18500 4500 131 394 10000 3800 3900 3600 23000 6500 175 525 8 10000 4700 4000 2800 26000 6500 175 525 15000 5000 4100 4100 34000 8500 262.50 787 8 20000 6200 4500 4300 41000 10500 350 1050 500 2250 1625 1750 3250 500 26.24 667 4 1000 2400 1700 1800 4500 1000 52.49 1333 5 1500 3200 2300 2000 6000 1200 78.73 2000 6 2000 3250 2600 2000 6500 1400 104.98 2667 6 500 3900 2500 2400 4500 500 26.24 667 4 1000 3900 2500 2400 5500 1000 52.49 1333 5 1500 3900 2500 2400 7500 1200 78.73 2000 6

Impedance ( z) is the minimum value as recommended by IEC 60076-5 Each Utility has their own specification that makes variations in dimension & weight and impedance etc. Hence for more precious information please get in touch with transformer manufactures. Upto 315 KVA, it is considered as pole mounted and 500 & above is ground mounted. All transformers are considered as with of circuit tab changer unless mentioned. All distribution transformers upto 2000 KVA are hermetically sealed with fin walls. 2000 KVA and above are conservator mounted with radiators. DEWA package sub station HV SF6 RMU and LV fuse type panel are in the same side. Other package sub stations HV SF6 RMU and LV panel are in the opposite side with housing. The IEC standards applicable for Transformers IEC 60076 1 - General ICE 60076 2 Temperature Rise IEC 60076 3- Insulation levels and Dielectric Tests IEC 60076 4-Tapping and Connections IEC 60076 5-Ability to withstand short circuit level IEC 60076 7-Loading guide for oil immersed transformer IEC 60076 8-Power Transformer Application guide IEC 60076 10- Determination of Sound level IEC 60076 14- Design & Application of liquid immersed transformer using high temp insulation IEC 60085 Thermal Classification IEC 6o137 - Insulating Bushing for AC Voltage above 1 KV IEC 60156 - Method of Testing of Electric Strength of Mineral Oil used in the Transformer IEC 60214 - On Load Tap Changer IEC 60296 - Specification of Unused Minerals Oil for Transformer & Switchgear IEC 60330 - Package Sub Station IEC 60354 - Loading guide for oil immersed Transformer IEC 60404 - Electrical Steel ( core steel ) IEC 60437 - Radio Interference Test on High Voltage Insulators IEC 60529 - Degree of Protection by enclosures ( IP code ) IEC 60599 - Guide to interpretation of dissolved and free gases analysis IEC 60616 - Terminal Marketing for Power Transformer IEC 60890 - Specification of Silicon oil for electrical purpose IEC 60944 - Maintenance of Silicon oil in the transformer BS 5493 - Protective Coating of Iron & Steel Structure against corrosion BS 148 - OIL Cooled Transformer & BS 171 Air Cooled Transformer BS 381 - Painting DIN 42500 Three Phase Oil Immersed Public Transformers

Details of Various Tests on the Transformers Routine Tests o Measurement of Winding Resistance o Measurement of Winding Insulation Resistance ( Megger ) o Measurement of Voltage Ratio o Verification of Vector group ( Phase Displacement ) o Measurement of Impedance Voltage o Measurement of Load Loss o Measurement of No Load Loss and No Load Current o Induced Over Voltage Test (Appling double the voltage & Frequency for 60 seconds) o Separates Source Voltage withstand Test on HV and LV winding for 60 seconds. Winding Voltage in KV in delta Winding Test Voltage in KV 132 66 33 22 15 11 6.6 3.3 230 140 70 50 38 28 20 10 3 LV Less than 1.1 KV Type Test: o Temperature Rise Test o Full valve Impulse Voltage withstand Test including Chopped Wave (Dielectric Type Test IEC 60076-3) Special Tests: o Short Circuit withstand Test o Measurement of sound level o Measurement of Harmonics of no load current o Measurement of Zero sequence impedances o Measurement of power consumption of Auxiliaries like pump, fan etc o Determination of Winding capacitance o Measurement of dissipation factor ( tan )