S45 Pump Electric Proportional Control

Similar documents
H1B Motor Electric Proportional Control L1, L2

S42 Pump Electrical Displacement Control (EDC)

MP1 Pumps Non-Feedback Proportional Electric (NFPE) Control

Electrohydraulic Actuators PVEA/H/S

MAKING MODERN LIVING POSSIBLE. Electrical Installation. M46 Pumps HC EDC. powersolutions.danfoss.com

Sensor EMD Speed Sensor

MAKING MODERN LIVING POSSIBLE. Electrical Installation. Pulse Pickup KPP PPU. powersolutions.danfoss.com

Electrohydraulic Actuator Type PVEP / PVEP-F

Technical Information Output Configurations for PLUS+1 Controllers powersolutions.danfoss.com

Sensors Q625A Remote Setpoint Module

Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com

Sensors ACE100B DC Millivolt Input Amplifier

MCX103A Non-Contact Rotary Position Sensor. Technical Information

Ultrasonic Controller/Sensor. Technical Information

ACX104B Potentiometer Rotary Position Sensor. Technical Information

POWER SYSTEM MODE STATUS

MCHXXX Control Handle

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

Global Application Development Centers. Creating and proving solutions to customer challenges. A truly global team working for. you.

PLUS+1 High Current Controller Family

Technical Information. FDCA Fan Drive Control Assembly

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Proportional Directional Control Valves Nominal sizes 16 and 25

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Electro-Hydraulic Components Electronic Controllers Machine Management Systems. Working out integration between related technologies

ELECTRONIC CONTROL DEVICES

4/3 Proportional Directional Valve, Size SAE 10

Infocal 9 Energy calculator

PFM 5000 Measuring Instrument

No-Contact, CANbus Rotary Position Sensor NRH27C

Proportional Directional Control Valves Size 6

Precision Voltage Control System

Speed sensor DSA series 12

Electro-Hydraulic Components Electronic Controllers Machine Management Systems. Working out integration between related technologies

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

SonoMeter 31 Energy Meters

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Analog amplifier RA. RE Edition: Replaces:

Electronic Pressure Switch Type MEP

Technical Information

Direct Operated Proportional DC Valve Series D1FP

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

DIGITAL CONTROL OF ELECTRO-HYDRAULIC STEERING TEST BENCH

PROPORTIONAL PRESSURE CONTROLS TECNORD

Sealed Interface Control: EC20300

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Proportional Directional Control Valves Size 6

Functional Safety Application Guide

Hagie STS/DTS (2018 & Newer)

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

D.C. Hydraulic Power Systems

Data Sheet MEM 16. Incremental Encoder Magnetic

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Sensor Datasheet Collection

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Technote. Actuator Frese OPTIMA. Application. Features actuator DN15-DN32. Features actuator DN40-DN50. Approval.

Self contained servo drive CLDP Technical data sheet

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

BOLTIGHT HYDRAULIC BOLT TENSIONING TIGHTEN BOLTS SIMULTANEOUSLY TO ENSURE EVEN PRELOAD

Connection to the sensor is with simple flying leads for customer termination. 1 Page NRH300DP Rev B 09/15

Ordering Part Numbers: SAE J1939 version Controller: AX022400

SonoSelect 10 and SonoSafe 10 Energy Meters

TECHNICAL DATASHEET #TDAX021901

2-way motor valve. Power consumption. Type 8746 MFC/MFM. Technical data Materials Body Housing Seals 1) Pressure Range 2) < 1 % FS Sensitivity Span

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

DVC700 Series Programmable System Controller

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

with Electronic Assistant

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi)

ODU-MAC A PERFECT ALLIANCE. MANUAL MATING AUTOMATIC DOCKING SHORT OVERVIEW

Programmable with Electronic Assistant Simulink

PHOTOELECTRIC SENSORS. Online data sheet

Product Information. ECA 4000 V Absolute Modular Angle Encoder for Application in High Vacuum

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

PRODUCT SPECIFICATIONS

Digital amplifier for proportional valves PEM XD

Product Bulletin PB M8 5-pole B-coded Cordsets

Mini-Expansion Unit (MEU) User Guide V1.2

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Product features and advantages

PROPORTIONAL PRESSURE CONTROLS TECNORD

KINAX SR 719 Programmable Transmitter for Position Feedback

Agilent 8762F Coaxial Switch 75 ohm

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Genuine Metaris Telescopic Cylinders

Continental Hydraulics Installation Manual CEM-RA-A

User Manual. Proportional Directional Control Valve PRM7

PX2 Series Heavy Duty Pressure Transducer

Coriolis Mass Flow Meters. Advanced flow measurement made easy.

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Product information PI 01. Head-type tool turret

M5800 Pressure Transducer with Rotatable Display

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Transcription:

Electrical Installation S45 Pump Electric Proportional Control powersolutions.danfoss.com

Revision history Table of revisions Date Changed Rev August 2016 Updated graphs and changed to Engineering Tomorrow 0202 September 2015 Converted to Danfoss layout BA January 2013 First edition AA 2 Danfoss August 2016 L1205447 0202

Contents Literature references Product overview Electrical installation S45 Electric Proportional Control literature references...4 Latest version of technical literature... 4 Product image... 5 Nomenclature...5 Theory of operation...6 Operating pressure versus input current... 6 Hydraulic schematics... 7 Pressure compensation controls...7 Electrical specifications... 7 Pinout...8 DEUTSCH connector... 8 Pin compatibility...8 Mating connector...8 DEUTSCH connector parts list... 8 Danfoss August 2016 L1205447 0202 3

Literature references S45 Electric Proportional Control literature references Literature title Description Literature number S45 Axial Piston Open Circuit Pumps Technical Information Function Block User Manual Complete product electrical and mechanical specifications Compliant function block set-up information 520L0519 L1210641 Latest version of technical literature Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/ 4 Danfoss August 2016 L1205447 0202

Product overview Product image S45 Electric Proportional Control Nomenclature R S P C D E F G H J K L M N P200 146 Electric proportional control options normally closed Code Description Frame L K J F E AH Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) Left AL Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Left AV Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) Right AK Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Right BH Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) [>280 bar] Left BL Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) [>280 bar] Left BM Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) [>280 bar] Right BK Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) [>280 bar] Right EM Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) EN Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Electric proportional control options normally open Code Description Frame L K J F E AH Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) Left AL Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Left AV Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) Right AK Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Right BH Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) [>280 bar] Left BL Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) [>280 bar] Left BM Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) [>280 bar] Right BK Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) [>280 bar] Right EM Electric Proportional Pressure Control w/pressure Comp. (NC,12VDC) EN Electric Proportional Pressure Control w/pressure Comp. (NC,24VDC) Danfoss August 2016 L1205447 0202 5

Product overview Only certain control options for the S45 pump use this electric proportional control. Please refer to the motor s nomenclature to determine if the pump is equipped with the proper option. You can find the nomenclature on the pump s nametag. For nomenclature details, refer to S45 Axial Piston Open Circuit Pumps Technical Information, 520L0519. Theory of operation When an electric current is sent to the normally closed configuration control, the pump pressure decreases proportional to an increase in current. When an electric current is sent to the normally open configuration control, the pump pressure increases proportional to an increase in current. When the load in the system changes, the pump will adjust its displacement to maintain the pressure demanded by the controlling current. This control is especially useful for fan-drives, due to the direct relationship between fan-speed and pump pressure. Due to the nature of electric proportional controls, the relationship between current and pump pressure is unique for each individual PC/LS pressure setting combination. Operating pressure versus input current Normally closed electric proportional control 350 300 310 Bar PC, 20 Bar LS System Pressure (Bar) 250 200 150 100 260 Bar PC, 20 Bar LS 210 Bar PC, 20 Bar LS 310 Bar PC, 30 Bar LS 50 310 Bar PC, 10 Bar LS 0 0 0.2 0.4 0.6 0.8 1 Current I/Imax (ma) P108 657E Normally open electric proportional control 350 System Pressure (Bar) 300 250 200 150 100 310 Bar PC, 30 Bar LS 310 Bar PC, 20 Bar LS 260 Bar PC, 20 Bar LS 210 Bar PC, 20 Bar LS 310 Bar PC, 10 Bar LS 50 0 0 0.2 0.4 0.6 0.8 1 Current I/Imax (ma) P108 658E 6 Danfoss August 2016 L1205447 0202

Product overview Hydraulic schematics Pressure compensation controls Normally closed electric proportional Normally open electric proportional B Outlet S Inlet L1, L2 Case drain M2 System pressure gauge port X Load sense port Electrical specifications For both normally open and normally closed solenoids Voltage 12V 24V Maximum current 1500 ma 665 ma Inrush current 1700 ma 800 ma Coil resistance at 20 C [70 F] 7.1 Ω 28.5 Ω PWM range 200-300 Hz 200-300 Hz PWM frequency (preferred) * 250 Hz 250 Hz IP rating (IEC 60529 DIN 40050-9) IP67 IP67 IP rating (IEC 60529 DIN 40050-9) with mating connector IP69K IP69K Operating temperature * PWM siginal required for optimum control performance. Consistent with pump limits: -40 C (-40 F) to 104 C (220 F) Consistent with pump limits: -40 C (-40 F) to 104 C (220 F) Danfoss August 2016 L1205447 0202 7

Electrical installation Pinout DEUTSCH connector Pin location 1 2 Pinout Pin Function 1 PWM signal 2 Ground Pinout (alternative) Pin Function 1 Ground 2 PWM signal Pin compatibility PLUS+1 module pin type Pin Function 1, 2 PWMOUT/DOUT/PVG Power supply * 1, 2 PWMOUT/DOUT/PVGOUT * 1, 2 Power ground * Use output pins with configurable PWM frequency. Mating connector DEUTSCH connector parts list Description Quantity Ordering number Connector 1 DEUTSCH DT06-2S Wedge lock 1 DEUTSCH W2S Socket contact (16 and 18 AWG) 2 DEUTSCH 0462-201-16141 Mating connector kit 1 Danfoss K29657 8 Danfoss August 2016 L1205447 0202

Danfoss August 2016 L1205447 0202 9

10 Danfoss August 2016 L1205447 0202

Danfoss August 2016 L1205447 0202 11

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Danfoss Your Strongest Partner in Mobile Hydraulics. Hydraulic Power Steering Go to www.powersolutions.danfoss.com for further product information. Integrated Systems Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors Please contact the Danfoss Power Solution representative nearest you. PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmuellerinverter.com Local address: Turolla www.turollaocg.com Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions Trading (Shanghai) Co., Ltd. Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss August 2016 L1205447 0202