SE Series User Manual

Similar documents
Operation Instructions NORDAC SK 400E. Frequency Inverter. SK 400E B / SK 400E B (0.4kW / 0.7kW, 1~ 115V)

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

GS1 Parameter Summary Detailed Parameter Listings...4 9

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER 8 PARAMETER SUMMARY

WARNING. must comply with the laws of the country where the AC drive is to be installed. Refer to Basic Wiring Diagram.

Manual Overview...1 2

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

FE0 9

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

VLT MICRO Series Adjustable Frequency Drive Instruction Manual

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

CHAPTER 3 WIRING DANGER

TOSVERT TM VF-nC3 Parameter List

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

FREQUENCY INVERTER. Series L2500 MANUAL

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Fan and Pump AC Inverter

6.9 Jump frequency - Avoiding frequency resonance

Operating Instructions

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

SAFETY INSTRUCTIONS WARNING

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

General Specifications FECA-TE /2010. Phone: Fax: Web:

VFD-M Series User Manual

S11 Adjustable Speed Drive Engineering Specification

Preface WARNING. CAUTION! Heat sink may heat up over 70 o C (158 o F), during the operation. Do not touch the heat sink.

Preface PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

VF-nC1 Adjustable Speed Drive Engineering Specification

LG Variable Frequency Drive

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life.

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

VSC. Instruction Manual - English

GS S. Compact Space Ve VFD. Frequency and .5 5

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

CARLO GAVAZZI Automation Components. Quick Start Guide Motor Controllers AC Variable Frequency Drives Type VariFlex 3 RVLF

E3 Adjustable Speed Drive Engineering Specification

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

E L (0) / FAX:+31(0)

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

ZVD AC Motor Drive User Manual

This operation manual is intended for users with basic knowledge of electricity and electric devices.

ACH550 HVAC Drive Submittal

NX Series Inverters. HVAC Pocket Programming Guide

L100-M Series Inverters

IC5 Series. LG Variable Frequency Drive 1/2-3 HP (230V) LG Industrial SystemsG. Installation, Operation and Maintenance Instruction

Emotron VSA Variable Speed Drive

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

Phoenix DX Clean Power (18 Pulse) AC Drive

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Operating Instructions & Parts Manual. AC Motor Speed Control. Model 13E662 A40353

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Inverter Drive /Vector Drive Motors & Controls

4.2.3 Main Circuit Cable Size and Tightening Torque Control Circuit Control Circuit Terminals

VFS11 Parameter List for up to CPU version 105

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

VFD-EL Series User Manual

HPVFP High Performance Full Function Vector Frequency Inverter

SAFETY INSTRUCTIONS. After reading this manual, keep it in the place that the user always can contact easily.

SYSDRIVE 3G3XV Inverter 3G3XV- -EV2 Operation Manual

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

CAUTION. - The product is a changed speed operation device which is used to control three-phase induction motor.

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

THYFREC-VT230S 200V System 0.4 to 90kW 400V System 0.4 to 370kW INSTRUCTION MANUAL

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

ADJUSTABLE SPEED DRIVES. AS1 Drive

VFD-EL Series User Manual

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive

PowerFlex 400 Submittal

VS-616PC5/P5 Series User s Manual

[ 4 ] Using pulse train input (F01 = 12)

EI-450 Series. 220V Class 1HP~7½ HP 440V Class 1HP~10 HP. EI-450 User Manual RICH ELECTRIC CO., LTD.

ADJUSTABLE SPEED DRIVES FS1

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

The new Yaskawa Varispeed G7 Inverter

Specifications of ASDA A2-E_220V Series

Microprocessor Controlled I G B T Drive Inverter Motor Speed Regulator Operating Manual. S310 Serise 200V class 0.4~1.5KW (0.88~2.

smd frequency inverter

Superior performance just for you

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

idrive EDX AC micro-inverters for small 3-phase induction motors

VS1SM Single Phase AC Drive

Be sure to hand over this instruction manual to customers.

15P0073B1. Inverter SINUS M USER MANUAL. Eng lish

USER MANUAL -Installation and Programming Instructions-

HITACHI. L100 Series Inverter Instruction Manual. Cover. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

Transcription:

SE Series User Manual 22V 2W-2HP Simple General Purpose AC Drive ASIA SANCH ELECTRIC CO.,LTD. Sales Office/ LUO JIANG INDUSTRIAL ZONE ZHUANGREN 2#, CHINA TEL:886-595-267315 FAX:886-595-267319 Http://www.sanch.net

Preface Thank you for choosing SANCH s SE series AC Drive. The SE series is manufactured using high-quality components, material and incorporating the latest microprocessor technology available. This manual will help in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drive. To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC motor drive. Keep this operating manual handy and distribute to all users for reference. Important Notes: DANGER! AC input power must be disconnected before any maintenance. Do not connect or disconnect wires while power is applied to the circuit. Only qualified technicians should perform maintenance on the SE. CAUTION! There are highly sensitive MOS components on the printed circuit boards. These components are especially sensitive to static electricity. To avoid damaging these components, do not touch the circuit boards with metal objects or your bare hands. DANGER! A charge may still remain in the DC-link capacitor with hazardous voltages even after the power has been turned off. To avoid personal injury, do not remove the cover of the AC drive until all DISPLAY LED lights on the digital keypad are off. Please note that there are live components exposed when the AC drive is open,. Be careful to not touch these live parts. CAUTION! Ground the SE using the ground terminal. The grounding method must comply with the laws of the country where the AC drive is to be installed. DANGER! The AC drive may be destroyed beyond repair if power is misapplied to the input/output terminals. Never connect the AC drive output terminals U/T1, V/T2, W/T3 directly to the AC main circuit power supply. 1

Chapter 1 Receiving and Inspection This SE AC drive has gone through rigorous quality control tests at the factory before shipment. Since many things may happen during shipping, please check for the following after receiving the AC motor drive. Inspect the unit to insure it was not damaged during shipment. Make sure that the part number indicated on the nameplate corresponds with the part number of your order. Nameplate Information: Example of 1HP 22V AC Drive Model Input Spec. Output Spec. Output Freq. Range MODEL:SE-271A INPUT:AC 1PH 2~24V 5/6Hz OUTPUT:3 PH ~24V 4.2A 1.6kVA FREQUENCY RANGE:1.~4Hz SANCH ELECTRIC CO.,LTD Model Explanation: S E - 27 1 A version Input voltage 1: Applicable motor capacity 2:.2kW 4:.4kW 7:.75kW Variable Frequency Drive 2

Dimension 3

Chapter 2 Wiring Basic Wiring Diagram Users must connect wiring according to the circuit diagram shown below. Please follow all National and State wiring codes, when wiring the SE. Main Circuit Power Motor Factory default settings +18V Forward/Stop M 4.7K +18V Reverse/Stop M1 4.7K +18V Reset M2 4.7K +18V Multi-step 1 M3 4.7K Common Signal GND Power supply for Potentiometer +1V 1mA(MAX) Master Freq. setting 3 2 Analog voltage VR +1V AVI ~ 1VDC VR:3K~5K 1 Analog current GND 6*1 RS-485 Communication p ort RA Multi-function indication output contacts 12VAC/28VDC 3A RC Factory default: Fault Indication RJ-11 1:+EV 2:GND 3:SG- 4:SG+ Main circuit (power) terminals Control circuit terminals Shielded leads NOTE: Do not plug in a Modem or telephone line to the RS-485 communication port, pe rm an e nt d am ag e m ay result. Term ina ls 1 & 2 are th e pow e r so u rce fo r th e op tion al co py keyp ad a nd sh ould no t be use d w hile using R S -4 85 com m u nica tio n. 4

( 1 2 VA C /D C 2 8 V 3 A ) M ulti- function indication output contact P o w e r fo r s p e e d s e ttin g A nalog Voltage, current frequency com m and M ulti-function assistant term inal M ulti- function input selection 1 M ulti- function input selection 2 M ulti- function input selection 3 C o m m o n s ig n a l Main circuit wiring AC line input terminals grounding S in gle ph a se m od els in pu t from R /L1, S /L 2 T/L3 LED display Frequency setting knob Function Display key Data Confirmation key RUN/STOP Motor capacity and input power The signal selection for AV I to in p ut DC~+1V or 4~2 ma RS485 communication port Motor connections U/T1, V/T2, W/T3 Grounding Control circuit wiring Wire Gauge:12-2AWG Torque: 5kg-cm RA RC +1V AVI M M1 M2 M3 GND Relay 5

Wiring Notes: PLEASE READ PRIOR TO INSTALLATION. 1. CAUTION: Do not connect the AC input to any of the U/T1, V/T2, W/T3 terminals, as it will damage the AC drive. 2. WARNING: Ensure all screws are tightened to the proper torque rating. 3. During installation, follow all national and local electrical, construction, and safety codes for the country the drive is to be installed in. 4. Ensure the appropriate protective devices (circuit breaker or fuses) are connected between the power supply and AC drive. 5. Make sure that the leads are connected correctly and the AC drive is properly grounded. (Ground resistance should not exceed.1.) 6. Use ground leads that comply with AWG/MCM standards and keep them as short as possible. 7. Multiple SE units can be installed in one location. All the units should be grounded directly to a common ground terminal. The SE ground terminals may also be connected in parallel, as shown in the figure below. Ensure there are no ground loops. Forward running When the AC drive output terminals U/T1, V/T2, and W/T3 are connected to the motor terminals U, V, and W, respectively, the motor will rotate counterclockwise (as viewed from the shaft ends of the motor) when a forward operation command is received. To reverse the direction of motor rotation, switch over any of the two motor leads. 9. Make sure that the power is capable of supplying the correct voltage and required current to the AC drive. 1. Do not attach or remove wiring when power is applied to the AC drive. 11. Do not monitor the signals on the circuit board while the AC drive is in operation. 12. Route the power and control wires separately, or orthogonal to each other. 13. If a filter is required for reducing EMI (Electro-Magnetic Interference), install it as close as possible to AC drive. EMI can also be reduced by lowering the Carrier Frequency. 14. If the AC drive is installed in the place where a load reactor is needed, install the filter close to U/T1, V/T2, W/T3 side of AC drive. Do not use a Capacitor or L-C Filter (Inductance-Capacitance) or R-C Filter (Resistance-Capacitance). 15. When using a GFCI (Ground Fault Circuit Interrupt), select rrent cu sensor with minimum current 2mA, and minimum detection time.1-second to avoid nuisance tripping. 6

Chapter 3 Summary of Parameters Group : User Parameters - Identity code of drive (Read only) 3: 2W 4: 4W 5: 75W The parameter may be set during operation. Factor -1 Rated current display (Read only) 2W: 1.6A 4W: 2.5A 75W: 4.2A -2 Parameter reset 1: Reset Parameters to Factory -3 Start-up display of AC : F (Frequency command) drive 1: H (output frequency) 2: U (user-defined unit) 3: A (output current) -4 User-defined Unit : Display User-Defined Unit (u) 1: Display Counter Value (C) 2: Display Process Operation (1=tt) 3: Display DC-BUS voltage (U) 4: Display output voltage (E) -5 User-defined coefficient.1 ~ 16 1. -6 Software version Read only #.# -7 Password input ~ 999-8 Password configuration ~ 999 Group 1: Basic Parameters Factor 1- Maximum operation Freq 5. ~ 4Hz 6. 1-1 Maximum setting Freq. 1. ~ 4Hz 6. 1-2 Maximum output voltage 2. ~ 255V 22 1-3 Mid-point freq. 1. ~ 4Hz 1. 1-4 Mid-point voltage 2. ~ 255V 12. 1-5 Minimum output freq. 1. ~ 6.Hz 1. 1-6 Minimum output voltage 2. ~ 255V 12. 1-7 Upper bound of freq. 1 ~ 11% 1 1-8 Lower bound of freq. ~ 1%. 1-9 Accel time 1 (Tacc1).1 ~ 6 Sec 1. 1-1 Decel time 1 (Tdec1).1 ~ 6 Sec 1. 1-11 Accel time 2.1 ~ 6 Sec 1. 7

Factor 1-12 Decel time 2.1 ~ 6 Sec 1. 1-13 JOG Accel time.1 ~ 6 Sec 1. 1-14 JOG Decel time. ~ 6 Sec 1. 1-15 JOG frequency 1.Hz~4Hz 6. 1-16 Auto-accel/decel : Linear Accel/Decel 1: Auto accel, linear decel 2: Linear accel, auto decel, 3: Auto Accel/Decel 4: Linear accel. Auto decel, stall preventio during deceleration 5: Auto accel. Auto decel, stall prevention during deceleration 1-17 S-curve setting in acceleration ~ 7 1-18 S-curve setting in deceleration ~ 7 Group 2: Operation Method Parameters aramete Functions s 2- Source of frequency command 2-1 Source of operation command : Digital keypad 1: ~ 1V from AVI 2: 4 ~ 2mA from AVI 3: Controlled by V.R on drive 4: RS-485 communication interface : By digital keypad 1: By external terminals, keypad STOP enable 2: By external terminals, keypad STOP disable 3: By RS-485 communication interface, keypad STOP enable 4: By RS-485 communication interface, keypad STOP disable Factor 2-2 Stop method : Ramp stop 1: Coast stop 2-3 Carrier freq. 3 ~1k Hz 1 2-4 Reverse operation inhibit : Enable reverse 1: Disable reverse 2: Disable forward 2-5 ACI (4 ~ 2mA) input loss detection : Decel to Hz 1: Stop immediately, display EF 2: Run with the last freq. 2-6 Line Start Lockout : Enable 1: Disable 8

Group 3: Output Function Parameters acto Settin 3- Desired freq. attained 1. ~ 4 Hz 1. 3-1 Terminal count value ~ 999 3-2 Preliminary count value ~ 999 3-3 Multi-function (relay output) : not used 1: AC drive operational 2: Max. Output Freq. Attained 3: Zero Speed 4: Over Torque 5: Base-Block (B.B.) 6: Low Voltage Detection 7: AC Drive Operation Mode 8: Fault Indication 9: Desired Freq. Attained 1: PLC Program Running 11: PLC Program Step Complete 12: PLC Program Complete 13: PLC Program Operation Pause 14: Terminal Count Value Attained 15: Preliminary Count Value Attained 16: Ready State Indicator 8 Group 4: Input Function Parameters Factor setting 4- Potentiometer bias freq.. ~ 35Hz. 4-1 Potentiometer bias polarity : positive bias 1: negative bias 4-2 Potentiometer freq. gain 1 ~ 2% 1 4-3 Potentiometer : not used reverse motion 1: reverse motion enable 4-4 4-5 4-6 enable Multi-function input terminal1 (M1) (d ~ d 2) Multi-function input terminal 2(M2) Multi-function input terminal 3(M3) (d, d 4 ~ d 2) 2: forward motion only : not used 1: M: FWD/STOP, M1: REV/STOP 2: M: RUN/STOP, M1: FWD/REV 3: M, M1, M2: 3-wire operation control mode 4: External fault, normally open (N.O.) 5: External fault, normally closed (N.C.) 6: RESET 7: multi-step speed command 1 8: multi-step speed command 2 9: jog operation 1: accel/decel speed inhibit 11: first or second accel/decel time selection 12: base-block (B.B.),normally open (N.O.) 13: base-block (B.B.),normally closed (N.C) 1 6 7 9

Factor setting 4-6 Multi-function input 14: increase master freq. 7 terminal 3(M3) (d, d 4 ~ d 2) 15: decrease master freq. 16: run PLC program 17: pause PLC 18: counter trigger signal 19: counter reset 2: select ACI/deselect AVI Group 5: Multi-step Speed and PLC Parameters acto Settin 5-1 st step speed freq.. ~ 4Hz. 5-1 2 nd step speed freq.. ~ 4Hz. 5-2 3 rd step speed freq.. ~ 4Hz. 5-3 PLC mode : Disable PLC operation 1: Execute one program cycle 2: Continuously execute program cycles 3: Execute one program cycle step by ste (separate by STOP) 4: Continuously execute one program cycle step b step (separate by STOP) 5-4 PLC forward/revers ~ 15 (: Forward 1: Reverse) motion 5-5 Time duration step ~ 655 Sec 5-6 Time duration step ~ 655 Sec 5-7 Time duration step ~ 655 Sec 5-8 Time duration step ~ 655 Sec Group 6: Protection Parameters acto Settin 6- Over-Voltage :disable Prevention Level 35~41V 39 6-1 Over-current : disable 17 Prevention Level 2~2% 6-2 Over-torque :disable detection 1:enable during constant speed operation(ol2) and continues until the continuous limit is reached. 2:enable during constant speed operation(ol2) and halted after detection. 3:enabled during accel and continues befor continuous output time limit is reached. 4:enabled during accel and halted after over-torque detection. 6-3 Over-torque detection level 3 ~ 2% 15 1

6-4 Over-torque detection time 6-5 Electronic thermal overload relay 6-6 Electronic thermal characteristic 6-7 Present fault recor 6-8 Second most rece fault record 6-9 Third most recent fault record 6-1 Forth most recent fault record 6-11 Fifth most recent fault record 6-12 Sixth most recent fault record Group 7: Motor Parameters Group 8: Special Parameters acto Settin.1 ~ 1. Sec.1 : Not used 1: Act with standard motor 2: Act with special motor 3~6 Sec 6 : No fault occurred 1: oc (over current) 2: ov (over voltage) 3: oh (over heat) 4: ol (over load) 5: ol1 (electronic thermal) 6: EF (external fault) 7: Reserved 8: Reserved 9: oca (current exceed during acceleration) 1: ocd (current exceed during deceleration) 11: ocn (current exceed during steady state) aramete Functions s Factory 7- Motor rated current 3~12 % 85 7-1 Motor no-load curre ~ 9 % 5 7-2 Torque compensation ~ 1 1 7-3 Slip compensation. ~ 1.. Factory 8- DC braking voltage level ~ 3% 8-1 DC braking time during start-up. ~ 6. Sec. 8-2 DC braking time during stopping. ~ 6. Sec. 8-3 Start-point for DC braking. ~ 4. Sec. 8-4 Momentary power loss : Stop operation after momentary power loss. 1: Continues after momentary power loss speed search starts with master freq. 2: Continues after momentary power loss speed search starts with min. output freq. 11

Factory 8-5 Max. allowable power los time.3 ~ 5. Sec 2. 8-6 B.B. time for speed search.3~5. Sec.5 8-7 Max. speed search curren level 8-8 Skip freq. 1 upper bound.~4 Hz. 8-9 Skip freq. 1 lower bound.~4 Hz. 8-1 Skip freq. 2 upper bound.~4 Hz. 8-11 Skip freq. 2 lower bound.~4 Hz. 8-12 Skip freq. 3 upper bound.~4 Hz. 8-13 Skip freq. 3 lower bound.~4 Hz. 8-14 Auto restart after fault ~1 8-15 AVR function : AVR function enable 2 1: AVR function disable 2: AVR function disable when decel 8-16 ynamic braking voltage 35 ~ 45V 38 8-17 C braking lower bound limi. ~ 4 Hz. Group 9: Communication Parameters Factor 9- Communication address 1 ~ 247 1 9-1 Transmission speed : Baud rate 48 1: Baud rate 96 2: Baud rate 192 1 9-2 Transmission fault treatment 9-3 Modbus communication watchdog timer 9-4 Communication protocol : Warn and continue running 1: Warn and ramp to stop 2: Warn and coasting stop 3: No warn and keep running : Disable 1~2: 1 ~ 2 Sec ASC mod RTU mod : 7,N,2 1: 7,E,1 2: 7,O,1 3: 8,N,2 4: 8,E,1 5: 8,O,1 6: 8,N,2 7: 8,E,1 8: 8,O,1 12

CHAPTER 4 Troubleshooting and Fault Information The SE AC drive has a comprehensive fault diagnostic system that includes several different alarms and fault messages. Once a fault is detected, the corresponding protective functions will be activated. The following faults are displayed on the AC drive digital keypad. The six most recent faults can be read on the digital keypad display by viewing Pr.6-7 to Pr.6-12. NOTE: faults can be cleared by pressing the Reset key on the keypad or Input Terminal. Common Problems and Solutions: Faul Fault Descriptions Corrective Actions Nam The AC drive detects an abnormal increase in current. The AC drive detects that the DC bus voltage has exceeded its maximum allowable value. The AC drive temperature sensor detects excessive heat. The AC drive detects that the DC bus voltage has fallen below its minimum value. nternal electronic overload trip The external terminal EF-GND goes from OFF to ON. Motor overload. Check the parameter settings ( Pr.6-3 to Pr.6-5). Check whether the motors horsepower corresponds to the AC drive output power.. Check the wiring connections between the AC drive and motor for possible short circuits. Increase the Acceleration time (Pr.1-9, Pr.1-11).. Check for possible excessive loading conditions at the motor.. If there are any abnormal conditions when operating the AC drive after the short-circuit is removed, the drive should be sent back to manufacturer.. Check whether the input voltage falls within the rated AC drive input voltage.. Check for possible voltage transients.. Bus over-voltage may also be caused by motor regeneration. Increase the decel time. Ensure that the ambient temperature falls within the specified temperature range.. Make sure that the ventilation holes are not obstructed.. Remove any foreign objects on the heat sin and check for possible dirty heat-sink fins.. Provide enough spacing for adequate ventilation. Check whether the input voltage falls within the rated AC drive s input voltage.. Check for possible motor overload.. Check electronic thermal overload setting.. Increase motor capacity.. Reduce the current level so that the drive output current does not exceed the value set by the Motor Rated Current Pr.7-. When external terminal EF-GND is closed, the output will be turned off. (under N.O., E.F.). Reduce the motor load.. Adjust the over-torque detection setting to an appropriate setting. 13

Faul Nam Fault Descriptions Over-current during acceleration:. Short-circuit at motor output.. Torque boost too high.. Acceleration time too short.. AC drive output capacity is too small. Over-current during deceleration:. Short-circuit at motor output.. Deceleration time too short.. AC drive output capacity is too small. Over-current during steady state operation:. Short-circuit at motor output.. Sudden increase in motor loading.. AC drive output capacity is too small. Internal memory IC can not be programmed. Internal memory IC can not be read. Drive s internal circuitry abnormal. Hardware protection failure Software protection failure Auto accel/decel failure Communication Error External Base Block. AC drive output is turned off. he AC drive detects excessive drive utput current. Corrective Actions. Check for possible poor insulation at the output line.. Decrease the torque boost setting in Pr.7-2. Increase the acceleration time.. Replace with the AC drive with one that has higher output capacity (next HP size).. Check for possible poor insulation at the output line.. Increase the deceleration time.. Replace with the AC drive with one that has higher output capacity (next HP size).. Check for possible poor insulation at the output line.. Check for possible motor stall.. Replace with the AC drive with one that has higher output capacity (next HP size).. Switch off power supply.. Check whether the input voltage falls within the rated AC drive input voltage.. Switch the AC drive back on.. Check the connections between the main control board and the power board.. Reset drive to factory defaults.. Switch off power supply.. Check whether the input voltage falls within the rated AC drive input voltage. Switch on the AC drive. Return to the factory. Return to the factory. Don t use the function of auto acceleration/ deceleration.. Check the connection between the AC drive and computer for loose wires.. Check if the communication protocol is properly set.. When the external input terminal (B.B) is active, the AC drive output will be turned off.. Disable this connection and the AC drive will begin to work again.. Check whether the motor is overloaded.. Reduce torque compensation setting as set in Pr.7-2.. Increase the AC drive s output capacity.. Note: The AC drive can withstand up to 15% of the rated current for a maximum of 6 seconds. 14

Standard Specifications Voltage Class 22V Model Number SE-2 1A 2 4 7 Applicable Motor Output (kw).2.4.7 Output Rating Rated Output Capacity (kva.6 1. 1.6 Rated Output Current (A) 1.6 2.5 4.2 Max. Output Voltage (V) Three-phase corresponds to input voltage Rated Frequency (Hz) 1.~4Hz Rated Input Current (A) 4.9 6.5 9.7 Power Input voltage Tolerance Single phase 2~24V 5/6Hz Control Characteristics Operating Characteristics Environment Frequency tolerance ±5% Control system Output Frequency Resolution SVPWM (Sinusoidal Pulse Width Modulation, carried frequency 3kHz~1kHz).1Hz Torque Characteristics Including the auto-torque, auto-slip compensation, starting torque can be 15% at 5 Hz Overload Endurance 15% of rated current for 1 minute Accel/Decel Time.1~6Sec. (can be set individually) V/F pattern V/F pattern adjustable Stall Prevention Level 2~2%, setting of Rated Current Keypad by keys or V.R Frequenc Potentiometer-5k* /.5W, DC ~ +1V (input impedance 47k * ), 4~2mA (output External Signal impedance 25 * ), multi-function inputs1 to 3 (3steps, JOG, UP/DOWN command), communication setting Operation Keypad by RUN//STOP keys Signal External Signal M,M1,M2,M3 can be combined to offer various modes of operation, RS-485 communication port Multi-function Input Signal Multi-step selection to 3, Jog, accel/decel inhibit, first/second accel/decel switch, counter, PLC Operation, external Base Block (NC,NO) selection Multi-function Output Signa Other Function Protection Other Cooling Installation Location Ambient Temperature AC Drive Operating, Frequency Attained, Non-zero speed, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication. AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency of DC Braking, ver-current Stall Prevention, Momentary Power Loss restart, Reverse Inhibitio Frequency Limits, Parameter Lock/Reset Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing Including EMI Filter Forced air-cooling Altitude 1, m or below, keep from corrosive gasses, liquid and dust -1* -4* (Non-Condensing and not frozen) Storage Temperature -2* to 6* Ambient Humidity Below 9%RH (non-condensing) Vibration 9.8665m/s 2 (1G) less than 2Hz, 5.88m/s 2 (.6Gat) 2 to 5Hz 15