Agilent NFA Noise Figure Analyzer

Similar documents
Agilent NFA Noise Figure Analyzer

Agilent NFA Noise Figure Analyzer

Keysight Technologies NFA Noise Figure Analyzer. Configuration Guide

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

Agilent Technologies Noise Figure Selection Guide

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent MXG Signal Generators

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Solutions for Solar Cell and Module Testing

Two-Way Radio Testing with Agilent U8903A Audio Analyzer

Agilent MXG Signal Generators

Agilent Maximizing Measurement Speed Using P-Series Power Meters

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Process Control Calibration Made Easy with Agilent U1401A

A Time-Saving Method for Analyzing Signal Integrity in DDR Memory Buses

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Agilent E4438C/E8267D Option 422 Scenario Generator for GPS

Agilent 87075C Multiport Test Set

Agilent Correlation between TDR oscilloscope and VNA generated time domain waveform

Multipurpose Lab Station by Agilent Technologies

Agilent N8262A P-Series Modular Power Meter and Power Sensors. Data Sheet

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

Agilent 8762F Coaxial Switch 75 ohm

Agilent PNA Series RF Network Analyzers

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Agilent E4428C and E4438C ESG Signal Generators

MXG X-Series Signal Generator N5183B Microwave Analog

Agilent U9397A/C FET Solid State Switches (SPDT)

Agilent E8257D PSG Microwave Analog Signal Generator

Agilent Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter. Application Note

Agilent J7211A/B/C Attenuation Control Units

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Evaluating Oscilloscope Bandwidths for your Application


Agilent 8761A/B Microwave Switches

Keysight Technologies Noise Figure X-Series Measurement Application N9069A & W9069A

Agilent E4428C and E4438C ESG Signal Generators. Confi guration Guide

Agilent U2000 Series USB Power Sensors. Data Sheet

Advanced Test Equipment Rentals ATEC (2832)

Agilent InfiniiMax III probing system

Agilent 4287A RF LCR Meter 1 MHz - 3 GHz. Technical Overview

Agilent N9310A RF Signal Generator. All the capability and reliability of an Agilent instrument you need at a price you ve always wanted

Solar Array Simulation System Integration

Agilent U1700 Series Handheld LCR Meters

Keysight E5063A ENA Series Network Analyzer

Making a S11 and S21 Measurement Using the Agilent N9340A

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N5531S Measuring Receiver

MIL-STD 1553 Triggering and Hardwarebased Decode (Option 553) for Agilent s InfiniiVision Series Oscilloscopes

Agilent U1240 Series Handheld Digital Multimeters

Agilent First-generation MXG Signal Generators

Keysight Technologies Noise Figure Selection Guide Minimizing the Uncertainties

Agilent N8700 Series System DC Power Supplies

Agilent U8903A Audio Analyzer


Agilent EPM Series Power Meters

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Agilent 2-Port and 4-Port PNA-X Network Analyzer

Educator s Oscilloscope Training Kit for the InfiniiVision 2000 & 3000 X-Series

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Keysight E5063A ENA Vector Network Analyzer

Agilent U2741A USB Modular 5.5 Digits Digital Multimeter. Data Sheet

Agilent N9340B Handheld Spectrum Analyzer (HSA)

EM Insights Series. Episode #1: QFN Package. Agilent EEsof EDA September 2008

Creating Arbitrary Waveforms in the U2300A Series and U2500A Series Data Acquisition Devices

Agilent HMMC-3124 DC-12 GHz Packaged High Efficiency Divide-by-4 Prescaler 1GC TR1-7" diameter reel/500 each 1GC BLK-bubble strip/10 each

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent E8267C PSG Vector Signal Generator

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent 81150A Pulse Function Arbitrary Noise Generator Applications

Essential Capabilities of EMI Receivers. Application Note

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Agilent Digital Modulation Lab Station

Agilent E1412A 6.5-Digit High-Accuracy Multimeter C-Size

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

N9051A Pulse Measurement Software

InfiniiMax III probing system

Agilent 84904, 6, 7K/L Programmable Step Attenuators

When is it Time to Transition to a Higher Bandwidth Oscilloscope?

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

I-V Curve Characterization in High-Power Solar Cells and Modules

Keysight Technologies Waveguide Power Sensors. Data Sheet

Agilent E7400A Series EMC Analyzers

Agilent EEsof EDA.

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

Keysight Technologies Noise Figure X-Series Measurement App, Multi-Touch

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Transcription:

Agilent NFA Noise Figure Analyzer Configuration Guide Dedicated Noise Figure Analyzer Hard specifications to 26.5 GHz Works with N4000A SNS or 346 Series noise sources Noise figure measurements to 110 GHz with block downconverters

Noise Figure Analyzer Overview Over 50 years of noise figure leadership In order to make accurate noise figure measurements, engineers need proven equipment that give repeatable results. To help meet that need, Agilent offers the only dedicated noise figure analyzer on the market. One of the advantages of a dedicated noise figure analyzer is the specified results, available up to 26.5 GHz, which outperform most traditional spectrum analyzer applications while costing less than a network analyzer solution. The NFA Series offers results similar to the obsolete 8970 noise figure meter. Some of the new features the NFA delivers include a graphical view and compatibility with smart noise sources for more details on the NFA, refer to the NFA Series Brochure, literature number 5989-0166E, available at www.agilent.com/find/nfa. The NFA Series standard configuration prepares engineers to make noise figure measurements immediately after instrument boot up as the preamplifier and noise figure software are both standard. There are three different frequency ranges to choose from: N8973A 10 MHz to 3.0 GHz N8974A 10 MHz to 6.7 GHz N8975A 10 MHz to 26.5 GHz Frequency range for Agilent NFA noise figure analyzers 10 MHz 3 GHz 10 GHz 20 GHz 30 GHz Helpful tip: The most popular option for enhancing the dedicated noise fi gure analyzers is Option 1D5, the high-stability frequency reference. Option 1D5 can only be purchased at the initial sale and is not available as an upgrade. For more information on Agilent s full portfolio of noise figure solutions see the Noise Figure Selection Guide, literature number 5989-8056EN, available at www.agilent.com/find/nf. Following are the additional options available for any of the dedicated noise figure analyzers: Option Description Upgrades N897x-1D5 High-stability frequency reference No N897x-A6J ANSI Z540 compliant calibration with test data Service Center N897x-1CP Rack mount and handle kit Yes N897x-UK9 Additional front-panel cover Yes N897x-1FP Calibration, performance verification, and adjustment software Yes 2 Get a quick quote in 2 minutes www.agilent.com/find/quick

Block Down Conversion Agilent offers the K-Series block downconverters, which extend the upper frequency limit of the N8975A from 26.5 GHz up to 110 GHz. The downconverter uses an internal LO to down convert the input signal to an IF that is within the measurement range of the NFA. The K-Series is offered in 13.5 GHz bands. For example, a customer that would like to make noise figure measurements to 52 GHz would order K40, K50, and K63 in order to bridge from the 26.5 GHz end frequency of the N8975A to the 52 GHz required. N8975AZ - K40 26.5 GHz to 40.0 GHz N8975AZ - K50 36.5 GHz to 50.0 GHz N8975AZ - K63 50.0 GHz to 63.0 GHz N8975AZ - K75 61.5 GHz to 75.0 GHz N8975AZ - K88 75.0 GHz to 88.5 GHz N8974AZ - K98 86.5 GHz to 100.0 GHz N8975AZ - K99 96.5 GHz to 110.0 GHz Frequency range for Agilent NFA noise figure analyzers 26.5 GHz 40 GHZ 60 GHz 80 GHz 100 GHz 120 GHz Note: The K-Series block downconverters can only be used with the N8975A and N9020A MXA signal analyzers. Find out more www.agilent.com/find/nf 3

Noise Source Selection The other critical piece of equipment needed to make a noise figure measurement is a noise source. Noise sources contribute to your total measurement noise figure via ENR uncertainty and input mismatch. The output of a noise source is defined in terms of its frequency range and excess noise ratio (ENR). Nominal ENR values of 6 db and 15 db are commonly available. A low ENR noise source will minimize error due to noise detector non-linearity. This error will be smaller if the measurement is made over a smaller, and therefore more linear, range of the instrument s detector. A 6 db noise source uses a smaller detector range than a 15 db noise source. Use a 15 db noise source for: General-purpose applications to measure noise figure up to 30 db User-calibrating the fullest dynamic range of an instrument before measuring high-gain devices Use a 6 db noise source for: Measuring a device with gain that is especially sensitive to changes in the source impedance The device under test (DUT) has a very low noise figure The device noise figure does not exceed 15 db Agilent offers three different families of noise sources, and all may be used in conjunction with the NFA. The smart noise sources simplify measurement set-up and improve accuracy and reliability, automatically downloading electronically stored calibration data to the instrument to save valuable time. The 346 Series noise sources are the traditional and most cost-effective solution, offering the widest range of frequency coverage. Lastly, Agilent offers high-frequency noise sources for customers making measurements above 26.5 GHz. If one source does not include both frequency ranges, a second source will be required. A second noise source may also be necessary when measuring a non-frequency translating device with low noise figure and high gain. Noise source ENR-typical Frequency range N4000A 4.6 6.5 db 10 MHz 18 GHz Smart Noise N4001A 14 16 db 10 MHz 18 GHz Sources N4002A 12 17 db 1 10 MHz 26 GHz 346A 5 7 db 10 MHz 18 GHz Traditional 346B 14 16 db 10 MHz 18 GHz Noise Sources 346C 12 17 db 10 MHz 26 GHz 346CK01 21 db 1 GHz 50 GHz High Frequency Q347B 6 13 db 33 GHz 50 GHz Noise Sources R347B 10 13 db 26.5 GHz 40 GHz Helpful tip: Agilent s most popular noise sources are the N4000A smart noise sources and 346B traditional noise source. For more information on these noise sources see the Noise Figure Selection Guide, literature number 5989-8056EN, or application note 57-3, 10 Hints for Making Successful Noise Figure Measurements, literature number 5980-0288E, both available at www.agilent.com/find/nf. 4 Get a quick quote in 2 minutes www.agilent.com/find/quick

Special Noise Source Options In order to meet unique customer requirements, Agilent offers the following special noise source options: Helpful tip: One of the most popular special noise source options is 346C-K01, which allows the 346C noise source to be used to 50 GHz. Option N4000A-H10 N4001A-H10 N4002A-H10 346A-H10 346B-H10 346C-H10 346A-H13 346B-H01 346B-H71 346B-H73 346B-H42 346C-H01 346C-K01 Description Standard lab calibration at 20 frequencies from the data sheet (10 MHz to 18 GHz) APC 3.5 (m) connector with 21 db nominal ENR Type N (male) connector with 21 db nominal ENR Type N (female) connector with 21 db nominal ENR DBS waveguide adapter and nominal ENR 5 db APC 3.5 (m) connector with 21 db nominal ENR 10 MHz to 50 GHz 346 Series noise source nominal ENR 21 db Noise Source Test Set The Agilent N2002A noise source test set is a standalone instrument that, as part of a calibration system, enables fast, repeatable calibrations with minimal levels of uncertainty. This test set is needed when making ENR tests on a noise source. Low-cost and easy-to-use, the N2002A noise source test set ensures accurate calibration results, increasing measurement confidence and allowing the development of DUTs with tighter specifications. The N2002A noise source test set operates over a frequency range of 10.0 MHz to 26.5 GHz. Features: Reduces noise figure uncertainty to ensure accurate and repeatable results Delivers results traceable to national standard Performs full calibration of all Agilent SNS and 346 noise sources Provides manual control or remote operations using GPIB For more information see www.agilent.com/find/nsts Find out more www.agilent.com/find/nf 5

Documentation A hard copy and CD version of the English language quick reference guide, user s guide, programmer s reference, and calibration and performance verification manual are included with the NFA. Selections can be made to change the localization of the manual set which will provide the quick reference guide and user s guide in the chosen language, and an English language version of the programmer s reference guide as well as calibration and performance verification manual. Option N897XA-0B1 N897XA-0B2 N897XA-0BF N897XA-AB0 N897XA-AB1 N897XA-AB2 N897XA-ABE N897XA-ABF N897XA-ABZ N897XA-ABD N897XA-ABJ N897XA-0B0 Description Additional NFA series manual set (English version) Additional NFA series user manual (English version) Additional NFA series programmer reference (English version) NFA series manual set for Taiwan -Chinese localization NFA series manual set - Korean localization NFA series manual set - Chinese localization NFA series manual set - Spanish localization NFA series manual set - French localization NFA series manual set - Italian localization NFA series manual set - German localization NFA series manual set - Japanese localization Delete hard copy manual set Additional Service Options Warranty R-51B Calibration R-50C-001 R-50C-002 Standard warranty is 12 months Occupied bandwidth For 3 years, order 36 months of the appropriate calibration plan shown below Standard calibration plan Standard compliant calibration plan 6 Get a quick quote in 2 minutes www.agilent.com/find/quick

Literature Resources Noise figure analyzer NFA Series Brochure, literature number 5980-0166E NFA Series Noise Figure Analyzers Configuration Guide, literature number 5980-0163E NFA Series Noise Figure Analyzers Data Sheet, literature number 5980-0164E Noise figure techniques Noise Figure Selection Guide, literature number 5989-8056EN Noise Figure Primer (AN 57), literature number 5989-6192EN Fundamentals of RF and Microwave Noise Figure Measurement (AN 57-1), literature number 5952-8255E Noise Figure Measurement Accuracy: The Y-Factor Method (AN 57-2), literature number 5952-3706E 10 Hints for Making Successful Noise Figure Measurements (AN 57-3), literature number 5980-0288E Noise Figure Measurements of Frequency Converting Devices (AN 1487), literature number 5989-0400EN Non-Zero Noise Figure After Calibration (AN 1484), literature number 5989-0270EN Practical Noise Figure Measurement and Analysis for Low-Noise Amplifier Designs (AN 1354), literature number 5980-1916E Noise sources SNS Product Overview, literature number 5988-0081EN Agilent 346A/B/C Noise Sources: 10 MHz to 26.5 GHz, literature number 5953-6452B Q347B Data Sheet, literature number EPSG084753 R347B Data Sheet, literature number EPSG084754 Noise source test N2002A Noise Source Test Set User s Guide, literature number N2002-90001 Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set, literature number 5988-7229EN Find out more www.agilent.com/find/nf 7

www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open Agilent Email Updates Agilent Direct www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies products, applications or services, please contact your local Agilent offi ce. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 0820 87 44 11 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 01805 24 6333** **0.14 /minute Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 27, 2008 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2008 Printed in USA, April 25, 2008 5980-0163E