Liquid Level Switches

Similar documents
Operating Instructions for Level Switch Tuning Fork Principal. Model: NWS

Level Sensors Reed Contact Chain

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Magnetic Inductive Flowmeter

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Full Metal Variable Area Flowmeter and Counter Model BGF

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

Electronic Flow Monitor

COMPACT-LINE. Transmitter for ph-value

Coriolis Mass Flow Meter Model TM

Coriolis Massflowmeter

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Electromagnetic flowmeter in all metal design Model MIM

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

NGR. Guided Wave Radar Level Transmitter

Insertion Thermocouples with Bayonet Lock

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

DUK. Compact Ultrasonic Flowmeter

Temperature Transmitters

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

Operating Instructions for Microwave Level Switch. Model: LNM

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

COMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Liquiphant T FTL20H. Technical Information

Through-beam ring sensors

Frame through-beam sensors

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

OEM radar transmitter, for aggressive media level measurement

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Coriolis Massflowmeter

NBK-04. Level Indicator for Tank-Top Mounting

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

SALES SERVICE +358 (0)

TMU. Coriolis Mass Flow Meter. for liquids and gas

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Level and Pressure. Product Information. Vibrating level switches

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

Coriolis Massflowmeter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

INLINE flowmeter for continuous flow measurement

DUK COMPACT ULTRASONIC FLOWMETER

Float Switches with Permanent Magnet For Vertical Installation Model RSM

INSTALLATION AND OPERATION MANUAL

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

INLINE flowmeter for continuous flow measurement

Technical Information Smartec CLD18

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Digital inductive conductivity transmitter

DOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C

KFS. Flap-type flow meter. Design and range of application

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Magnetic level switches ERH-xx-20

INSERTION paddle wheel flowmeter for continuous flow measurement

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

prosonic T FMU230, FMU231

Target disk flowmeter for liquids and gases

INLINE flowmeter for continuous flow measurement

LEVEL Switches RFM-500 RAM-403 RRH-300 RLH-300 RNM-401

ph or ORP Transmitter

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

vega-line price list 2011/12

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Mass Flowmeter CoriolisMaster FCM2000

OPTIFLUX 5000 Technical Datasheet

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Liquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet


2-Wire. Level Gauge BM 702

Magnetic Inductive Flow Sensors induq. Series VMI

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

Technical Information Smartec CLD18

Mass Flowmeter CoriolisMaster FCM2000

Electromagnetic Flow Transmitter

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

CombiTemp TCR6 Standard RTD temperature sensor

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

Digital flow ELEMENT transmitter for continuous flow measurement

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Rod probe With coaxial tube reference probe

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

Technical Information Condumax CLS21D/CLS21

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Level and Pressure. Product Information. Conductive level detection

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Soliphant T FTM20, FTM21

Transcription:

Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange, hygienic thread Material: Stainless steel.4404 Viscosity: max. 5000 mm /s No moving parts Insensitive to plant vibrations ATEX version 03-00 KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, CANADA, CHILE, CHINA, COLOMBIA, CZECHIA, FRANCE, GERMANY, GREAT BRITAIN, INDIA, IRAN, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHER LANDS, PERU, POLAND, SINGAPORE, SLOVAKIA, SPAIN, SWITZER LAND, THAILAND, USA, VENEZUELA, VIETNAM KOBOLD Messring GmbH Nordring -4 D-6579 Hofheim/Ts. +49(0)69 99-0 Fax +49(0)69 3398 E-Mail: info.de@kobold.com Internet: www.kobold.com Model: NWS 5

N Description The KOBOLD liquid level switch NWS is designed as a and 3-wire switch and can be universally used in vessels and pipelines. The NWS operates on the tuning fork principle in air at resonance frequency. A piezoelectric crystal is used for excitation of oscillations and for monitoring the actual oscillation frequency. When the fork is immersed in liquid, the frequency changes: this change is detected electronically and the output signal is changed. The NWS operates as a two-wire switch in series with the load. The simple electronic switch is operated by the liquid. The NWS can also be connected to a PLC through a third terminal. Special features The NWS has an output state indicator with an LED that can be seen though a lens in the cover. The LED flashes about once a second when the NWS has switched off and is permanently illuminated when the NWS is switched on. The LED is an optical confirmation that the NWS is working correctly and the condition of the wet side is correctly displayed. The NWS can be set as upper or lower limiter with a mode selector. Applications Oils Water Paints and transparent inks Sauces Milk Liquids containing carbon dioxide Foamed oils Technical Details Material Fork: stainless steel.4404 Process connection: stainless steel.4404 Electronic housing: NWS-...00: PAG, glass-fibre-reinforced cover with window, 330 rotatable all other types: stainless steel.430 Process connections: pipe thread DIN EN 06-, NPT thread, Tri-Clamp, pipe connection DIN 85 (sanitary connection), aseptic-connection DIN 864, DRD flange, flange B 5 PN 40 DN 57, flange B 50 PN 40 DN 57, flange ANSI B 6.5 - ", 300 lbs, flange ANSI B 6.5 - ", 300 lbs Protection: plastic housing: IP 65 (NWS-...00) stainless steel housing, plug connection: IP 67 stainless steel housing, cable connection: IP 68 Max. operating pressure: Max. medium temp.: Min. medium density: Ambient temperature: Min. immersion depth for switch points: Power supply NWS-...00..: 45 bar flange connection: see pressure steps 30 C (NWS-..00..) 90 C (for all other NWS) short-time 50 C for CIP (valid for all models NWS) 800 g/l (lower on request) -0 C...+70 C mm (marker on fork) 4...40 V DC / AC (50/60 Hz); -wire; 4 V DC, 3-wire NWS-...3/4/W/H..: 4 V DC, 3-wire The NWS is ideal for hygienic and sterile applications and for NWS-...E..(ATEX): Isolation Switching Amplifier to CIP cycles up to 50 C. IEC 60947-5-6 (Namur) necessary (for example: REL-6) ATEX version: Delay: s wet /dry s dry / wet Type of protection: intrinsically safe ia Designation: II G EEx ia II C T6 Viscosity: 5000 mm /s max. at 5 C (influence on the response time) To use in connection with intrinsically safe Isolation Switching Amplifier according to Hysteresis: 4 mm vertical, mm horizontal IEC 60947-5-6 Repeatability: ± mm Weight: 0.5 kg (for R 3 4 and 3 4 NPT) 5 www.kobold.com /07-00

Electrical connection NWS-...00... -wire 4-40 V AC/DC, serial Load, I max 500 ma NWS-...00... 3-wire, V S = 4 V DC Output PNP: U HIGH 6.5 V; U LOW.5 V; I max 500 ma 500 ma PE PE 500 ma N Last L V+ 4 N 3 V- 4 Load NWS-...3/4 (4 V DC ) NWS-...W/H (WHG in preparation) NWS-...E... (ATEX) GND (n.c.) + Vs (n.o.) + Vs E + S (n.o.) + Vs (n.c.) GND (n.o.) Switch out GND Switch out -S + S (n.c.) Wiring diagram Colour of core NWS-...3/4 NWS-...W/H Lead-/ Pinnumber NWS-...E (ATEX) brown blue black + Vs (n.o.) / GND + Vs GND / + Vs (n.c.) GND Swich out Swich out 3 4 + S (n.o.) Earth S + S (n.c.) Wiring examples NWS-...E... with Power supply unit acc. to IEC 60947-5-6 Plug Mx E + S (n.o.) + Isolation Switching Amplifier IEC 60947-5-6 (for example: REL-60xx) S + S (n.c.) Cable.5 m Lead No. (Lead No. 4) + Isolation Switching Amplifier IEC 60947-5-6 (for example: REL-60xx) Lead No. Lead No. 3 03-00 www.kobold.com 53

Order Details (Example: NWS-R0 00 0070) Connection Model Electrical connection Sensor version N R 3 4 male thread NWS-R0... R male thread NWS-R5...* 3 4 NPT male thread NWS-N0... Plastic housing 00 = 4...40 V AC/DC Cable gland/ terminal connection 0060 =60 mm (only for NWS-T / NWS-L / NWS-H) NPT male thread NWS-N5...* DIN flange DN 5 NWS-F5... DIN flange DN 50 NWS-F50...* " ANSI flange NWS-A5... " ANSI flange NWS-A50...* Tri-Clamp DN 40 NWS-T40... Tri-Clamp DN 50 NWS-T50... Sanitary conn. DN 40 (DIN 85) NWS-L40... Sanitary conn. DN 50 (DIN 85) NWS-L50... Aseptic conn. DN 50 (DIN 864) NWS-H50... DRD Ø 5 mm flange NWS-DZ... St. steel housing/plug connection 3S = 4 V DC, PNP, plug Mx 4S = 4 V DC, NPN, plug Mx WS***= 4 V DC, WHG, PNP, plug Mx HS***= 4 V DC, WHG, NPN, plug Mx ES= ATEX approval, plug Mx St. steel housing/cable connection 3F = 4 V DC, PNP,.5 m cable 4F = 4 V DC, NPN,.5 m cable WF***= 4 V DC, WHG, PNP,.5 m cable HF*** = 4 V DC, WHG, NPN,.5 m cable EF = ATEX approval,.5 m cable 0070 = 70 mm standard version, short (not for NWS-T / NWS-L) 07** = 7 mm extended 0300**= 300 mm sensor 0500**= 500 mm sensor 000**= 000 mm sensor XXXX**= please specify special length 4-position in mm (max. 3000 mm) Special connection NWS-YYY... **only models marked with * are available with sensors in extended version. ***WHG-approval in preparation. Dimensions NWS-...00 4...V AC/DC Plastic housing NWS-...3S/4S NWS-...WS/HS 4 V DC Plug connection NWS-...3F/4F NWS-...WF/HF 4 V DC Cable connection NWS-...ES ATEX Plug connection NWS-...EF ATEX, Cable connection 09 ø 80 ca. 84 3,5 ø 70 65 70 54 www.kobold.com 03-00

Dimensions (continued) NWS-...0070 (Standard, short) 0 3 NWS-R5...07 NWS-N5...07 (extended) 60 88 60 60 88 7 70 3 N 0 NWS-T... Tri-Clamp 0 NWS-F... / NWS-A... Flange version approx. 36 7 9 L 4 AF L3 L L 3 DN 5 / PN 40 DN 50 / PN 40 ANSI " 300 lbs ANSI " 300 lbs 8 approx. 47 0 7.5 approx. 95 approx. 4.4 approx. 9 NWS-L... Sanitary connection (DIN 85) 0 NWS-H... Aseptic connection (DIN 864) 03-00 www.kobold.com 55

For Temperature Measurement and Temperature Monitoring... N... please refer to our brochure»t+t«kobold Manufacturer for Innovative Instrumentation 56 www.kobold.com 03-00