On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - OVERALL LEVEL MODE, the user can select either DIGITAL or ANALOG.

Similar documents
Also, side banding at felt speed with high resolution data acquisition was verified.

PeakVue Analysis for Antifriction Bearing Fault Detection

Presentation at Niagara Falls Vibration Institute Chapter January 20, 2005

IMPACT DEMODULATION. An Over-Sampling Signal Processing Technique Used to Diagnose Bearing Faults

CSI 9330 Vibration Transmitter

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Capacitive MEMS accelerometer for condition monitoring

Testing Sensors & Actors Using Digital Oscilloscopes

Shaft Vibration Monitoring System for Rotating Machinery

CASE STUDY: Roller Mill Gearbox. James C. Robinson. CSI, an Emerson Process Management Co. Lal Perera Insight Engineering Services, LTD.

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

CSI 9420 Wireless Vibration Transmitter

MTN/8066/G-MAC VIBRATION MODULE

CSI 9420 Wireless Vibration Transmitter

9330 Vibration Transmitter

Pioneering Partnership Performance

Vibration based condition monitoring of rotating machinery

Understanding Discrepancies in Vibration Amplitude Readings Between Different Instruments

CSI 9420 Wireless Vibration Transmitter

WIRELESS ASSET MONITORING

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

Industrial vibration sensor selection: piezovelocity transducers

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

LION. TechNote LT September, 2014 PRECISION. Understanding Sensor Resolution Specifications and Performance

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers

Industrial vibration sensor selection: Piezovelocity transducers

Panasonic, 2 Channel FFT Analyzer VS-3321A. DC to 200kHz,512K word memory,and 2sets of FDD

Vibration Data Collector Signal Analysis

VIBRATION DATA COLLECTOR SIGNAL ANALYSIS

Unstable Reading of Accelerometers in Cryogenic Service. Cryodynamics Division

AMS 9420 Wireless Vibration Transmitter

ME scope Application Note 02 Waveform Integration & Differentiation

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.

VIBRATION MONITORING OF VERY SLOW SPEED THRUST BALL BEARINGS

SVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION. SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK

CEC VIBRATION TRANSMITTER

Shaft Absolute Vibration Monitor Specifications

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 17. Aliasing. Again, engineers collect accelerometer data in a variety of settings.

HG4930 INERTIAL MEASUREMENT UNIT (IMU) Performance and Environmental Information

Statistical analysis of low frequency vibrations in variable speed wind turbines

ORBIGate The Turbomachinery Vibration Software

WHITE PAPER. Continuous Condition Monitoring with Vibration Transmitters and Plant PLCs

UNIT-3. Electronic Measurements & Instrumentation

BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 2: RESAMPLING TO IMPROVE EFFECTIVE DYNAMIC RANGE

GV-700 VIBE PORT. Installation and. Operating Manual

The Battle for Data Fidelity:Understanding the SFDR Spec

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

CASE STUDY: Rotor Bar Fault in AC Induction

Vibration Analysis on Rotating Shaft using MATLAB

Signals & Systems for Speech & Hearing. Week 6. Practical spectral analysis. Bandpass filters & filterbanks. Try this out on an old friend

Overall vibration, severity levels and crest factor plus

Troubleshooting accelerometer installations

Developer Techniques Sessions

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

Comparison of Transmissibility of Non-Metallic Materials For Vibration Isolation

Neurophysiology. The action potential. Why should we care? AP is the elemental until of nervous system communication

Biomechanical Instrumentation Considerations in Data Acquisition ÉCOLE DES SCIENCES DE L ACTIVITÉ PHYSIQUE SCHOOL OF HUMAN KINETICS

Using Spectral Analysis to Determine the Resonant Frequency of Vibrating Wire Gages HE Hu

Presented By: Michael Miller RE Mason

Dynamic Angle Estimation

Laboratory Test of Vibration of Micro/Nano Satellite for Environment Test Standardization

Sensor Portfolio for Machinery Health Applications

Enhanced API 670 monitoring of gearboxes

Laboratory Experiment #1 Introduction to Spectral Analysis

CardVibro Neo Model : VM-2004Neo

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

FAG Detector III The solution for monitoring and balancing. Technical Product Information

SCM5B48 ACCELEROMETER INPUT MODULE USER S MANUAL

Experiment 2: Electronic Enhancement of S/N and Boxcar Filtering

Vibration Fundamentals Training System

Chapter 1: Introduction. EET-223: RF Communication Circuits Walter Lara

Transfer Function (TRF)

Analogue Signals. M J Brockway. February 5, 2018

Advantages of Analog Representation. Varies continuously, like the property being measured. Represents continuous values. See Figure 12.

XMV16 / XIO16T Extended vibration monitoring card pair XMV16

SignalCalc Drop Test Demo Guide

Fundamentals of Vibration Measurement and Analysis Explained

Applications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems

Real-Time FFT Analyser - Functional Specification

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Unraveling Zero Crossing and Full Spectrum What does it all mean?

Lab 2b: Dynamic Response of a Rotor with Shaft Imbalance

Response spectrum Time history Power Spectral Density, PSD

Save Money and Decrease Downtime with Vehicle and Equipment Monitoring. Embedded Technology Summit National Instruments

As Published on EN-Genius.net

Graph Matching. walk back and forth in front of. Motion Detector

AMS 2140 Machinery Health Analyzer

Detection of an Inner Race Defect Using PeakVue

From Digital to RF Debugging in the Time and Frequency Domain. Embedded Systems Conference 2015 May 6-7, 2015

Embedded Surface Mount Triaxial Accelerometer

VCSO Mechanical Shock Compensation

An Introduction to Time Waveform Analysis

Chapter 2 Analog-to-Digital Conversion...

Frequency Response Analysis of Deep Groove Ball Bearing

Sistemas de Aquisição de Dados. Mestrado Integrado em Eng. Física Tecnológica 2015/16 Aula 3-29 de Setembro

Setting up a Multi sine impedance measurement

COMPARATIVE STUDY OF VIBRATION ISOLATORS USING PARAMETER TRANSMISSIBILITY

Trendmaster * Dynamic Scanning Module

Tool Condition Monitoring using Acoustic Emission and Vibration Signature in Turning

Transcription:

Title: Analog vs Digital for Overall Measurement Product: Data Collectors Program: 2115/2117 Version: Not Applicable Technology: Vibration Technote Number: 95-00008 On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - OVERALL LEVEL MODE, the user can select either DIGITAL or ANALOG. The Overall value, calculated in DIGITAL mode, will calculate the value from the low frequency cutoff to the maximum frequency specified. In other words, the overall is calculated over the defined frequency range of the spectrum. The Overall calculated in ANALOG mode will calculate the value from 2 Hz to the bandwidth of the instrument (2110-20khz, 2115-30khz, 2120-80khz). The Analog overall value is sometimes referred to as an Unfiltered reading and is calculated from the waveform.

Title: Analog vs Digital Integration Mode for Measurement Product: Application Notes Program: App Notes Version: Not Applicable Technology: Vibration Technote Number: 95-00118 On the analyzer under UTILITY - CHANGE SETUP - MEASUREMENT MODE - SIGNAL INTEGR MODE there is the choice of ANALOG or DIGITAL. ANALOG integration integrates data in the waveform then performs the FFT - Fast Fourier Transform. The end result is that the waveform stored is in the integrated units and the spectrum is stored in the integrated units. DIGITAL integration performs the FFT first then the integration is performed on the spectrum. The end result is that the waveform is stored in the raw units of the sensor and the spectrum is stored in the integrated units. A common setup is to use an Accelerometer and integrate the signal to Velocity units. If DIGITAL integration is used then the waveform will be stored in G's and the spectrum will be stored in IN/SEC. However, one disadvantage to using DIGITAL integration is low frequencies will be enhanced. This causes a "ski slope" effect or "integration leg" on the low end of the spectrum. Typically this does not cause a problem unless the user is analyzing slow speed machinery. The ANALOG integration steps are: 1. The Waveform is collected in Acceleration units of G's 2. The Integration is performed on the waveform. 3. The last Waveform collected is stored in Velocity units of IN/SEC 4. The FFT is performed. 5. The averaged spectrum is stored in Velocity units of IN/SEC The DIGITAL integration steps are:

1. The Waveform is collected in Acceleration units of G's 2. The last Waveform collected is stored in Acceleration units of G's 3. The FFT is performed. 4. The spectrum is averaged in Acceleration units of G's 5. The Integration is performed on the spectrum 6. The averaged spectrum is stored in Velocity units of IN/SEC

Title: Analog/Digital Overall/Integration - 4 Cases, 1 Exception Product: Application Notes Program: App Notes Version: Not Applicable Technology: Vibration Technote Number: 95-00123 Four possible cases for setup include: Overall Level Mode: Digital Digital Analog Analog Signal Integr Mode: Analog Digital Analog Digital If a customer indicates overall measurement in the data collector shows as digital, but upon checking setup in collector for overall measurement mode he has actually chosen analog. For overall mode in analog, the frequency range for data acquisition is 2 Hz to 20 Khz. For overall mode in digital, the frequency range is 2 x delta f to the F max specified in the analysis parameter set. For integration mode in analog, the initial waveform signal is integrated when collected. The waveform is then stored in the integrated units. The FFT is applied to this waveform to get the spectrum. Since integration is performed on waveform, the mathematical amplification of spectrum at low frequencies is eliminated. For integration mode in digital, the waveform is collected and an FFT is applied to it to get the spectrum. This spectrum is then digitally integrated to get required result. The waveform is saved in native units of sensor, but "ski slope" has been introduced at low frequencies of spectrum. The Exception: Assuming integration is being performed on the point, with the combination of analog overall and digital integration modes, the expected result does not occur. The overall measurement is saved in digital not analog. This is because to get an analog overall, an analog integrated time waveform is required. The waveform is already in digital mode to get the requested digital spectrum. In this situation the customer wanted overall in analog to be able to have any high frequency abnormalities indicated be trending overall values. The integration was in digital to keep waveform units in sensor units, Gs in this case.

CSI's recommendation is to take overall in digital and specify Fmax large enough to encompass the frequencies in question.usually, problems occurring at high frequencies are so small that 1xRPM or other multiples will mask any changes. CSI now has the ability to save 12 trend parameters and this should be adequate to include any high frequency bands. The integration mode should be in analog to eliminate amplification of values at low frequencies. A special time waveform may be specified to be collected in the analysis parameter set. This special time waveform will replace the original after FFT is performed, and can be specified to be collected in native units of sensor.

Title: Why Analog Overall is not recommended when collecting PeakVue Data Product: Application Notes Program: App Notes Version: Technology: Vibration Technote Number: 06-02026 A customer asks what the difference is in the Overall collection mode and how it affects PeakVue data. The signal processing method is the same whether Digital or Analog Overall is used. The spectrums shown below were collected on a rotor kit without moving the accelerometer, just the overall parameter was changed. The top spectrum was in Analog Overall and shows a value of.1246 G's as compared to the lower spectrum collected in Digital which is shown at.0540 G's. The Analog Overall will calculate a value from Fmin to the high end of the frequency response of the accelerometer. The Digital Overall will calculate a value from the Fmin to Fmax but because the HP Filter is set to 1KHz those values are filtered out and not included in the overall calculation. Accel-Accel 500Hz Fmax 1000 HZ HP filter used for PeakVue 1 Average Also note that the spectrums below taken from the rotor kit show all the energy below the High Pass FIlter selection. If no energy is present both Overall values could be very close.

The above spectrum was collected with Analog Overall

The above spectrum was collected with Digital RMS Overall