Universal Alarm Indicator

Similar documents
Instruction Manual. Digital Panel Meter Model 3153B

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Instruction Manual. Digital Meter Relay Model 4258 CAUTION

312, 316, 318. Clamp Meter. Users Manual

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Model Number Structure

INSTRUCTION MANUAL FOR PROGRAMMABLE CONTROLLER PCD-33A

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

2015 RIGOL TECHNOLOGIES, INC.

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

SHIMADEN DIGITAL INDICATORS

User s Manual. Ground Resistance Clamp On Tester MODEL

MV110-8A. Analog input module 8 channel. User guide

User s Manual CM2-MGR nd edition

DP2000 ORDERING GUIDE To Order MODEL NO.

AMP-13 OPERATOR S MANUAL

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

General Specifications

Phase-sequence Phase-loss Relay

DM-45 Digital Multimeter

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

User s Guide. Digital AC/DC Clamp Meter Model 38394

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

AMM-1022 Digital Multimeter USER`S MANUAL

Keysight 1147B 50 MHz Current Probe. User s Guide

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

1147A 50 MHz Current Probe

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

200Amp AC Clamp Meter + NCV Model MA250

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

TxBlock-USB Transmitter

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

Passive Component LCR Meter

User Guide. Digital AC/DC Clamp Meter Model 38394

AMP-12 OPERATOR S MANUAL

BC145 SIGNAL ISOLATOR BOARD

SHIMADEN DIGITAL INDICATORS

Agilent N2893A 100 MHz Current Probe

Agilent 1147A 50 MHz Current Probe

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

APPENDIX APPENDIX A 1

User s Manual Current Probe IM E. 8th Edition

Model 580 Digital Process Indicators Series

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Single-phase Voltage Relay

SIA, SIB, SIC, SID. User's Manual

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

Single-phase Current Relay

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

FC-33, DC SELECTABLE SIGNAL CONDITIONER

User s Manual Current Probe. IM E 2nd Edition IM E

ET-3888 True RMS Clamp Meter. User Manual

This Errata Sheet contains corrections or changes made after the publication of this manual.

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

General Specifications

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Passive Component LCR Meter

ITP16. Temperature indicator. User guide

NWS300 Field Type Smart Meter

742A Series Resistance Standards

General Specifications

Digital indicator for panel mounting With multi-function input Model DI25

User s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES

DIGEM f 96 x 48 EK. Applications. Description

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

R-X SERIES. Decade Resistor

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Micro-controller X Model: PXE4. Operation Manual. INP-TN5A1887a-E

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User's Manual. Clamp-on Power Datalogger. Model

Model Number Structure

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Multifunction Digital

General Specifications

User s Manual Current Probe IM E. 6th Edition

General Specifications

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

True RMS AC / DC Power Clamp Meter Model

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Light-strip indicator

MV110-8AS. Analog input module 8 channel. User guide

FC Series Signal Conditioners

JPQ2 PULSE ACCUMULATOR

BNC/TC-2095 RACK-MOUNT ADAPTER

Series Valve Temperature Controller. Instruction Sheet

Transcription:

Universal Alarm Indicator Model: PCA13 User s Manual CM2-PCA100-2001 4th edition

Copyright, Notices and Trademarks 1996-2012 Azbil Corporation All Rights Reserved. While this information is presented in good faith and believed to be accurate, Azbil Corporation disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer. In no event is Azbil Corporation liable to anyone for any indirect, special or consequential damages. This information and specifications in this document are subject to change without notice.

Azbil Corporation Introduction Inspection Symbols Correct installation, operation and periodic maintenance are essential to ensure safe operations, as is a thorough knowledge of operation, maintenance and safety instructions provided in this manual. On delivery, check that the model PCA13 specifications agree with your order and check for any damage that may have occurred during transportation. This instrument has been tested under stringent quality control. If you find any damage, or have any quality or specification questions, please tell us the model name and the product number immediately. Please verify that all of the following have been delivered to you: (1)model PCA13 main unit(2) Unit labels(3) User's Manual To ensure user safety, this manual uses the following symbols: WARNING This indicates a safety instruction that must be observed in order to avoid death or serious injury. CAUTION This indicates a safety instruction that must be observed in order to avoid minor injury or physical damage. PCA13 - Universal Alarm Indicator i

Safety Azbil Corporation Safety Instructions Limited Liability Disclaimer This product(s) has been designed, developed and manufactured for general-purpose application in machines and equipment. Accordingly when used in applications where plant/worker protection is paramount, special care should be taken to implement a failsafe and/or redundant design concept-from controllers to integrated systems- as well as periodic maintenance program. WARNINGS Failure to observe these warnings could result in electrical shocks, fire functional problems or personal injury. Make sure that the power is off when installing removing or wiring controllers. Do not touch power supply terminals or other parts with live currents. Be sure to ground all earth terminals before connecting external control circuits or systems. Follow standard wiring procedures and use the wires specified in instruction manuals. Operate controllers under the environmental conditions specified in specification sheets or instruction manuals (ambient temperature, humidity, vibration and shock) and at the specified supply voltage. Always provide proper ventilation. Do not disassemble controllers or touch internal parts. Be careful not to expose high-temperature parts to cooling fins or other parts that may overheat, either during operation or when power has recently been turned off. Do not touch moving parts like those in recorders while the product is operating Do not use sharp objects to press buttons. ii PCA13 - Universal Alarm Indicator

Azbil Corporation Safety Please observe the following safety rules in order to use this instrument correctly and safely. CAUTION The model PCA13 has no power switch. It will start operating as soon as it is connected to the power supply. Allow as least 15 minutes warm-up time is specified to ensure accurate data acquisition. After turning off, also allow a warm-up interval before use. If the model PCA13 is to be installed in a cabinet, ensure sufficient ventilation so that the temperature in the cabinet does not exceed 50 C. Do not use the model PCA13 under any of the following environmental conditions. Direct exposure to rain, condensation or leakages. High humidity. High temperature, direct sunlight dusty air or highly corrosive gas concentrations. Heavy external noise, radio waves, or static electricity. PCA13 - Universal Alarm Indicator iii

Table of Contents Chapter 1:Standard Specifications 1-1:General Specifications... 1-1 Thermometer Unit... 1-1 Input Sensor... 1-1 Temperature measurement range:... 1-1 Measurement accuracy... 1-1 Display for negative temperature input... 1-1 Display of open input... 1-1 Out-of-range display... 1-2 External resistance... 1-2 Overloading... 1-2 Receiver Unit... 1-2 Analog output Unit... 1-3 Loop check function unit... 1-3 Alarm Output... 1-3 Common Specifications... 1-4 1-2:External dimensions and panel cut-outs... 1-6 Exterior view... 1-6 Panel Cut-Outs...1-6 Chapter 2:Installing and Removing the Front Panel 2-1:Procedure... 2-1 2-2:Removing the front panel... 2-2 Chapter 3:Functions 3-1:Scaling... 3-1 Thermometer...3-1 Receiver... 3-2 Decimal Point setting... 3-3 Alarm output... 3-4 Hysteresis width... 3-5 Output delay... 3-5 Display Cycle... 3-5 Chapter 4:Setting Procedures Nomenclature...4-1 Range switch functions... 4-1 LED state... 4-2 Explanation of setting modes... 4-2 Changing Modes... 4-3 Setting Modes... 4-4 Mode 1 (Scaling)...4-4 Mode 2 (Alarm output)... 4-6 Mode 3 (Hysteresis width)... 4-7 Mode 4 (Output delay)... 4-8 Mode 5 (Display Cycle)... 4-9 Loop check function... 4-9 Factory setting... 4-10

Table of Contents Chapter 5:Terminal Layout Upper row... 5-1 Lower row... 5-1 Chapter 6:Upper Terminals T/C sensor input terminals (+, -)... 6-1 RTD sensor input terminals (A, B, B)... 6-1 Receiver input terminals (Hi, Lo)... 6-2 Analog output terminals (A.OUT+, A.Out-)... 6-2 Chapter 7:Lower Terminals Alarm output terminals (AL1,AL2, ALCOM)... 7-1 Hold (HOLD)... 7-1 Reset (RESET)... 7-2 Common (COM)... 7-2 Ground (GND)... 7-2 Power Supply(P1,P2)... 7-2 Chapter 8:Maintenance Maintenance... 8-1 Chapter 9:Calibration Procedure Introduction... 9-1 Calibration Procedure... 9-1

List of Figures & Tables - Figures - Figure 1-1 Exterior View of model PCA13... 1-6 Figure 1-2 Panel cut-outs...1-6 Figure 2-1 Example of installation... 2-1 Figure 2-2 Removing the front panel... 2-2 Figure 3-1 Thermometer - Example1... 3-1 Figure 3-2 Thermometer - Example 2... 3-1 Figure 3-3 Receive - Example 1... 3-2 Figure 3-4 Receiver - Example 2... 3-2 Figure 3-5 Hysteresis width 1... 3-5 Figure 3-6 Hysteresis width 2... 3-5 Figure 4-1 LED state... 4-2 Figure 4-2 Changing modes... 4-3 Figure 5-1 Terminal layout... 5-1 Figure 6-1 T/C sensor input terminals... 6-1 Figure 6-2 RTD sensor input terminals... 6-1 Figure 7-1 Alarm output terminals... 7-1 Figure 7-2 Hold terminal... 7-1 Figure 7-3 Reset terminal... 7-2 Figure 9-1 Connection diagram 1... 9-1 Figure 9-2 Connection diagram 2... 9-2 Figure 9-3 Connection diagram 3... 9-3 Figure 9-4 Connection diagram 4... 9-4 Figure 9-5 Connection diagram 5... 9-5 - Tables - Table 1-1: Range selection... 1-4 Table 4-1: Parts name... 4-1 Table 4-2: Range switch function... 4-1 Table 4-3: Explanation of setting modes... 4-2 Table 4-4: Factory setting... 4-10 Table 5-1:... 5-1 Table 5-2:... 5-1 Table 9-1:... 9-3 Table 8-1: Model number structure... 8-1

Azbil Corporation Chapter 1 : Standard Specifications 1-1 : General Specifications Thermometer Unit Input Sensor 3-wire resistance thermometer bulb (RTD) Pt100 Thermocouple (T/C)R,K,J,T, and B sensors Temperature measurement range: Pt.100 : -199.9 to +649.9 C; -327.8 to +999.9 F R sensor : 0 to +1749 C; +32 to +3180 F K sensor : -199 to +1349 C; -326 to +2460 F J sensor : -199 to + 399 C; -326 to +1650 F T sensor : -199 to +399 C; -326 to +750 F B sensor : +600 to +1799 C; +1112 to +3270 F Temperature in F is calculated for display in C. (Data in F) = (Data in C) * 9/5+32 Therefore,1 digit is skipped for display in F. Measurement accuracy RTD: ±(0.2% of rate + 0.3 C) ± (0.2% of rate +0.6 F) Temperature coefficient +200 ppm/ C T/C: ± (0.3% of rate + 1 C) ± (0.3% of rate + 2 C) Temperature coefficient + 300 ppm/ C (0 to 50 C) Reference contact compensation ±1 C, ±2 F Display for negative temperature input (-)display Display of open input RTD: Flashing 0000 Model PCA13 - Universal Alarm Indicator 1-1

Standard Specifications Azbil Corporation T/C: Flashing 0000 Out-of-range display Flashing -0000 or 0000 Pt100: -200.0 C or below, 650.0 C or above -328.0 F or below, 999.9 F or above R sensor: -100.0 C or below, 1800 C or above -148 F or below, 3272 F or above K sensor: -200 C or below, 1400 C or above -328 F or below, 2552 F or above J sensor: -200 C or below, 950 C or above -328 F or below, 1742 F or above T sensor: -200 C or below, 450 C or above -328 F or below, 842 F or above B Sensor: -20 C or below, 1800 C or above -4 F or below, 3272 F or above External resistance RTD: 5Ω max. per lead wire T/C: 500Ω max. Overloading RTD: ± 10V DC Ω T/C: ±100V DC Ω Receiver Unit Input: Display: Measurement accuracy: 1 to 5V DC or 4 to 20mA DC 0 to 9999, (-) display for negative scaling ± (0.1% of rate + 5 digits) Input resistance: +1 MΩ at 1 to 5V DC Overloading: 12.5Ω at 4 to 20mA DC ± 250V DC at 1 to 5V DC + 150mA DC at 4 to 20mA DC Out of range display: Flashing 0000 Offset function: Decimal Point: Changes the display value to the offset value allowing input below the offset. Set to any position using the front switches. 1-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Standard Specifications Analog output Unit Output: 4 to 20 ma DC (step output) An analog value(4 to 20mA DC) is output that corresponds to the value displayed on the thermometer and the receiver units. Tolerance: 0.5% of span for the display, at 23 C ± 2 C Resolution: Output impedance: 1/2000 step output 5M Ω min. Allowable load resistance:0 to 600Ω Output Cycle: Same as display cycle Loop check function unit Output setting method: Output: Tolerance: Output impedance: In 0.1%steps within a range of 0 to 100%, using the setting switch on the front panel. The displayed values are E00.0 to E99.9 and E100. 4 to 20 ma DC (step output) The output is 4mA at 0%,12mA at 50%,and 20mA at 100%. 0.5% of span for the display, at 23 C ±2 C 5MΩ min. Allowable load resistance:0 to 600Ω Output cycle: 100 ms Alarm Output Comparison length: 4 digits (numerical value) 1 digit (polarity) Setting range:-9999 to +9999 Comparison method: Independent setting of 2 points, high/low limit comparison, or comparison OFF Setting method: CPU comparison judgement method. The comparison setting remains unchanged even if the range is changed. Using front switches Comparison conditions:high limit comparison: Alarm output: Measurement value > High limit value Low limit comparison: Measurement value < Low limit value Comparison OFF: No comparison executed Relay contact output AL1 and AL2 share a a contact (COM). Model PCA13 - Universal Alarm Indicator 1-3

Standard Specifications Azbil Corporation Contact capacity: 125V AC 0.5 A (Resistance load) Comparison display: ALARM display; 2 points Hysteresis Width: Output delay: 250V AC 0.1A (Resistance load) High or low limit judgement displayed using red LEDs 1 to temperature range or scaling value Set using a front switch The current hysteresis width is rewritten to 1 when the input sensor and the scaling value are changed. ON delay: 0 to 100s, resolution:1s Set using a front switch. The output delay setting remains unchanged even if the range is changed. Common Specifications Range selection: Sensor or receiver input or loop check function selected using DIP switches. Table 1-1 Range selection Number Range Number Range Display: 0 No function 8 R Sensor F 1 Pt100 C 9 K Sensor F 2 R sensor C A J sensor F 3 K sensor C B T sensor F 4 J sensor C C B sensor F 5 T sensor C D Receiver input 6 B Sensor C E Loop check function 7 Pt100 F F No function Character height: Sampling Cycle: Display cycle: Input format: AD conversion: 7-segment red LED or green LED About 15 mm Zero suppress function provided. 2.5 times/s F: 400 ms M: 800 MS (average of 2 samplings is displayed) S: 2s (average of 5 samplings is displayed) Single-ended, floating input Dual slope integration method Noise elimination rate: Normal mode (NMR): 50 db min. Noise entering power line:1000 V Common mode (CMR): 110db min. 1-4 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Standard Specifications Hold: Reset: Dielectric strength: This function retains the measured value and the comparison output. Set at the terminal board. Not isolated from the input circuits. This function resets the comparison output. Set at the terminal board. Not isolated from the input circuits. Input terminal / relay terminal: 1000V AC for 1 minute Input terminal, relay terminal/case: 1500V AC for 1 minute Power terminal/relay terminal: 1500V AC for 1 minute Power terminal/gnd, case: 2100V DC for 1 minute Input terminal/analog output terminals: 500V AC for 1 minute Insulation resistance: 100MΩmin. at 500V DC Power Supply: Power dissipation: 90 to 132V AC or 180 to 264V AC, 50/60Hz About 5VA Operating ambient temperature:0 to 50oC Storage temperature: -20 to + 70oC Weight: Mounting: Unit Labels (Accessory) About 500g Fasten to the back of the panel using the special mounting fixtures. Unit labels are included with the original shipment. Attach the appropriate label to the indent at the lower right-hand side of the front panel. Model PCA13 - Universal Alarm Indicator 1-5

Standard Specifications Azbil Corporation 1-2 : External dimensions and panel cut-outs Exterior view [Unit: mm] 96 6.5 115 17.5 48 91 44 100 Figure 1-1 Exterior View of model PCA13 Panel Cut-Outs c b d a a: 10 mm min b: 18 mm min 0.8 c: 92± mm 0 0.6 d: 45± mm [Unit: mm] 0 Figure 1-2 Panel cut-outs 1-6 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 2 : Installing and Removing the Front Panel 2-1 : Procedure Required tool: Phillips-head (+) screwdriver Remove the mounts form both sides of the main unit, insert the main unit from the front of the panel, and fasten in place with the screws. Rear Panel Mounting fixtures Figure 2-1 Example of installation Panel cut outs: Refer to the preceding page Allowable panel thickness: 0.6 to 6 mm Tightening torque: 0.25 to 0.39 N m (2.5 to 4 kgf cm) CAUTION Be careful: the case may be deformed by excessively tightening screws Model PCA13 - Universal Alarm Indicator 2-1

Installing and Removing the Front Panel Azbil Corporation 2-2 : Removing the front panel Required tool: flathead (-)screwdriver CAUTION Remove the front panel by inserting a regular screwdriver into the indents parts at the bottom. Be careful: the front panel may be damaged by excessive force Front panel Use a flathead screwdriver to open the panel Figure 2-2 Removing the front panel 2-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 3 : Functions 3-1 : Scaling Thermometer The 4m A and 20m A points for the analog output can be set anywhere within the range allowed by the display. Example1: K sensor (Range 3) Scale settings: Full Scale: 1000 C Offset: 0 C Out-of-range display 1399 C Full scale Display 1000 C Offset 0 C -199 C Out-of-range display 4mA 20mA Output Figure 3-1 Thermometer - Example1 Example2: K Sensor (Range 3) Scale settings: Full scale: 0 C Offset: 500 C Display Out-of-range display 1399 C Offset 500 C Full scale 0 C -199 C Out-of-range display 4mA 20mA Output Figure 3-2 Thermometer - Example 2 Model PCA13 - Universal Alarm Indicator 3-1

Functions Azbil Corporation Receiver Set the 4mA and 20mA points for the analog output and display at the same time. Example 1: Receiver 1-5V (Range D) Scale settings: Full Scale: 6000 Offset: 1000 Full scale Display Input 6000 5V Offset 1000 1V 0V 4mA 20mA Output Figure 3-3 Receive - Example 1 Example 2: Receiver 1-5V (Range D) Scale settings: Full Scale: 1000 Offset: 5000 Display Output Full scale 1000 5V Offset 5000 1V 0V 4mA 20mA Output Figure 3-4 Receiver - Example 2 Refer to page 4 to 4 for the scaling setting procedure. 3-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Functions Decimal Point setting The decimal point position can be set for the receiver range (range D) Refer to page 4 to4 for the decimal point setting procedure. Model PCA13 - Universal Alarm Indicator 3-3

Functions Azbil Corporation Alarm output An alarm output can be set for the thermometer and receiver range (range 1-D) display. High and low limit comparisons, or comparison OFF can be independently set for AL1and AL2. Comparison conditions: High limit comparison: Measured value > High limit value Low limit comparison: Measured value < Low limit value Comparison OFF: No comparison is executed. Outputs an alarm generated by the relay contact point and at the same time, AL1 or AL2 will illuminate. The valid setting range is -9999 to + 9999. Setting a value outside the scaling range causes an alarm to output for out-of-range value. Refer to page 4 to 6 for the alarm output setting procedure. 3-4 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Functions Hysteresis width The valid range for hysteresis width setting is 1 to full scale. When 1 is set for hysteresis width, high limit comparison is set for AL1, and low limit comparison is set for AL2: Low limit set value High limit set value AL1 relay ON AL2 relay ON Figure 3-5 Hysteresis width 1 When 2 or more is set for hysteresis width, high limit comparison is set for AL1, and low limit comparison is set for AL2: High limit set value Display High limit hysteresis Low limit hysteresis Hysteresis width Low limit set value AL1 relay ON AL1 relay ON ON Output delay Figure 3-6 Hysteresis width 2 The hysteresis width is automatically rewritten to 1 when the range is changed. Refer to page 4 to 7 for the hysteresis width setting procedure. This is an ON delay function. If the displayed value exceeds high or low limits, an alarm is output after the delay time has elapsed. The valid setting range is 0 to + 100s (1-second resolution). Refer to page 4 to 8 for the output delay setting procedure. Display Cycle One of three cycles (400ms,800ms, and 2s) can be selected Refer to page 4 to 9 for the display cycle setting procedure. Model PCA13 - Universal Alarm Indicator 3-5

Functions Azbil Corporation 3-6 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 4 : Setting Procedures Nomenclature 1 AL1 AL2 RANGE MODE SHIFT UP 3 2 Appearance with front panel Table 4-1 Parts name 4 Appearance without front panel Name Function 1 Alarm Display: Alarm output monitor 2 Unit: Attach the unit label here 3 Front Panel: Remove this panel to access operating switches, such as for range setting 4 RANGE switch: Use this switch for selecting input and function 5 MODE switch: Use this switch to change from measurement mode to setup mode 6 SHIFT switch Use this switch to select the setup mode and also to Switch choose the number of digits you want for display of numerical values.use this switch to decrease the count when the loop check function is active 7 UP switch: Use this switch to increment the numerical value Switch when in the set up mode and to configure several other functions. Use this switch to increase the count when the loop check function is active 8 Switch: Use this switch to save settings 5 6 7 8 Range switch functions Table 4-2 Range switch function Number Range Number Range 0 --- 8 R sensor F 1 Pt100Ω C 9 K Sensor F 2 R Sensor C A J Sensor F 3 K Sensor C B T Sensor F 4 J Sensor C C B Sensor F 5 T Sensor C D Receiver Input 6 B Sensor C E Loop Check Function 7 Pt 100Ω C F --- Model PCA13 - Universal Alarm Indicator 4-1

Setting Procedures Azbil Corporation LED state On state Off state Blinking Figure 4-1 LED state Explanation of setting modes Table 4-3 Explanation of setting modes Name Display Range Function Mode 1 Scaling Mode 2 Alarm output Mode 3 Hysteresis Mode 4 Output delay 1 to D Used to set output scaling factor. Also, to set the decimal point position (when range D is selected). 1 to D Used to set the comparison conditions for AL1And AL2, as well as the comparison values. 1 to D Used to set the hysteresis width for alarm output comparison values. 1 to D Used to set the output delay for alarm output. Mode 5 Display cycle 1 to D Used to set the display cycle. 4-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Setting Procedures Changing Modes MODE SHIFT SHIFT SHIFT At least 1 second Measurement Mode 1 Mode 2 Mode 3 mode Scaling Alarm output Hysteresis width SHIFT SHIFT Mode 4 Mode 5 Measurement mode Output delay Display cycle Figure 4-2 Changing modes The model PCA13 has no setting mode for ranges 0, E, and F If you press MODE during any setting mode, the model PCA13 will immediately return to the measurement mode. During setting, if no switches are operated for about 5 minutes, the model PCA13 will automatically return to the measurement mode. Do not change the range while the setting mode is selected. The model PCA13 cannot change to any setting mode while in HOLD status. Release the HOLD before setting When range 0 or F is selected, ---- will be displayed. After entering a setting mode, the model PCA13 retains the pertaining alarm and analog output. When the range is changed it sometimes takes 5 to 6 seconds for the new setting to be reflected in the display, depending on the currently-selected display cycle. Model PCA13 - Universal Alarm Indicator 4-3

Setting Procedures Azbil Corporation Setting Modes Mode 1 (Scaling) Set the scale to 10.0 to 50.0 for input range D RANGE MODE SHIFT UP Press to select the change mode. RANGE MODE SHIFT UP The offset value will be displayed. (DP0 and DP1 will light up.) Press SHIFT to select the digit(s) you want to change (the selected digit will blink). Change the value(s) using the UP switch. (Note 1) (DP0 and DP1 will blink.) RANGE MODE SHIFT UP Press value. to save the offset RANGE MODE SHIFT UP The full-scale value will be displayed. (DP2 and DP3 will illuminate.) Press SHIFT to select the digit(s) you want to change (the selected digits blink). Change the value(s) using the UP switch. (Note 1) RANGE MODE SHIFT UP (DP2 and DP3 will blink.) Press value. to save the full-scale RANGE MODE SHIFT UP Note 2 The decimal point setting state will be displayed. Press UP to select the decimal point position you want to set. (Note 3) Note 2 The decimal point display will blink. RANGE MODE SHIFT UP Press the switch to save the decimal point position. 4-4 Model PCA13 - Universal Alarm Indicator

Azbil Corporation ~Note ~Note 1) Change the polarity during the setting of the highest digit Setting Procedures 2) The decimal point position can be set only when range D is selected. Skip this step when any other range is selected. ~Note 3) No decimal point DP1 DP2 DP3 ~Note 4) You must set a value range within the display range, otherwise the model PCA13 will not proceed to the next operation. Correct the setting first. Model PCA13 - Universal Alarm Indicator 4-5

Setting Procedures Azbil Corporation Mode 2 (Alarm output) Set the alarm output Set HI and 1000 for AL1 and off for AL2. RANGE MODE SHIFT UP Press to select the change mode. RANGE MODE SHIFT UP The AL1 setting condition will be displayed. (The AL1 lamp will blink.) Press UP to select the comparison condition. (Note 1) The comparison condition will blink. RANGE MODE SHIFT UP Press to save the comparison condition for AL1. RANGE MODE SHIFT UP Press SHIFT to select the digit(s) you want to change (the selected digit will blink). Change the value(s) using the UP switch. (Note 2) RANGE MODE SHIFT UP DP3 will blink during HI setting. DP0 will blink during LO setting. Press to save the AL1 value. RANGE MODE SHIFT UP The AL2 setting condition will be displayed. (The AL1 lamp will extinguish and the AL2 lamp will illuminate.) Using the UP switch, select the comparison condition. (Note 1) RANGE MODE SHIFT UP The comparison condition will blink. Press to save the comparison condition for AL2. (The AL2 lamp will extinguish.) 4-6 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Setting Procedures ~Note 1) Alarm output OFF LO setting HI setting ~Note ~Note 2) Polarity is always the highest digit 3) When alarm output OFF is selected do not set alarm values. Mode 3 (Hysteresis width) Set the hysteresis width to 10. RANGE MODE SHIFT UP Press to select the change mode. RANGE MODE SHIFT UP Hysteresis width will be displayed. (The AL1 and AL2 lamps will blink.) Press SHIFT to select the digit(s) you want to change (the selected digit will blink). Change the value using the UP switch. RANGE MODE SHIFT UP Press to save the hysteresis value. (Note 1) (The AL1 and AL2 lamps will extinguish.) ~Note 1) You must set 1 or a larger value. Setting 0 prevents the model PCA13 from proceeding. Correct the setting. Model PCA13 - Universal Alarm Indicator 4-7

Setting Procedures Azbil Corporation Mode 4 (Output delay) Set the output delay to 10s RANGE MODE SHIFT UP Press to select the change mode. RANGE MODE SHIFT UP Hysteresis width will be displayed. (The AL1 and AL2 lamps will blink.) Press SHIFT to select the digit(s) you want to change (the selected digit will blink). Change the value(s) using the UP switch. RANGE MODE SHIFT UP Press to save the delay time. (Note 1) (The AL1 and AL2 lamps will extinguish.) ~Note 1) The valid range is 0 to 100s. Values outside this range will latch to 100. Correct the setting. 4-8 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Setting Procedures Mode 5 (Display Cycle) Set the display cycle to 2s RANGE MODE SHIFT UP Press to select the change mode. The display cycle will be displayed. RANGE MODE SHIFT UP Press UP cycle. to select the display RANGE MODE SHIFT UP Press to save the display cycle. F (400ms) M (800ms) S (2s) Loop check function Output setting range:0 to 100%,0.1% resolution Display method: Setting Procedure: 0.0% to 99.9% 100% 4mA 20mA output Set the RANGE switch to E to select the loop check function. The display changes by 1 (0.1%) each time the or switch is pressed The display will change rapidly if you hold the or switch down. Press saved. and the display will blink. The current value will be Model PCA13 - Universal Alarm Indicator 4-9

Setting Procedures Azbil Corporation Factory setting Table 4-4 Factory setting No. Range Scaling or output setting Comparison Setting AL1 AL2 Hyster esis width Output delay Display cycle 0 - - - - - - - 1 Pt 100 C 0.0 to 500.0 2 R C 0 to 1000 3 K C 0 to 1000 4 J C 0 to 500 5 T C 0 to 200 6 B C 0 to 1000 7 Pt 100 F 32.0 to 932.0 OFF OFF 1 0 400ms 8 R F 32 to 1832 9 K F 32 to 1832 A J F 32 to 932 B T F 32 to 392 C B F 32 to 1832 D Receiver input 0 to 4000 E Loop Check Function 0% --- --- -- -- -- F - - --- --- -- -- -- 4-10 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 5 : Terminal Layout Upper row Table 5-1 Terminal name Function + - A B B Hi Lo A.OUT+ A.OUT - 1 2 3 4 5 6 7 8 9 T/C sensor RTD sensor input Receiver input Analog output input Lower row Table 5-2 Terminal name ALI AL2 ALCOM HOLD RESET COM GND P2 P1 1 2 3 4 5 6 7 8 9 Function Alarm output Hold Reset Common Ground Power Terminal Screw: Tightening torque: M3 0.4 to 0.62 N-m (4.7 to 6.3 kgf cm) Grimp terminal: See the illustration on the right. Figure 5-1 Terminal layout WARNINGS Be sure to connect the cables correctly. Incorrect cabling can cause damage to hardware. To avoid electric shock, ensure that power is turned off before starting cabling work. To avoid electric shock, do not perform cabling work in a high-humidity environment while hands are wet. To avoid electric shock, do not touch the power terminal while it is alive. Model PCA13 - Universal Alarm Indicator 5-1

Terminal Layout Azbil Corporation 5-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 6 : Upper Terminals T/C sensor input terminals (+, -) CAUTION Ensure correct polarities when connecting thermocouples T/C Figure 6-1 T/C sensor input terminals RTD sensor input terminals (A, B, B) Connect Pt.100 Ω (three wires). When two wire resistance is used, please short -circuit terminals B and B. A B B Pt100Ω Figure 6-2 RTD sensor input terminals Model PCA13 - Universal Alarm Indicator 6-1

Upper Terminals Azbil Corporation Receiver input terminals (Hi, Lo) CAUTION To connect the measurement input, ensure correct polarities. Connect the measurement input having the higher potential to the Hi terminal. Ensure that the input and power lines are laid independently of each other. Parallel cabling of the input and power lines can destabilize indication. Analog output terminals (A.OUT+, A.Out-) These terminals are for analog output signals that are scaled. Also, they output the set value of the loop check function as an analog signal. CAUTION The analog output circuit is insulated form the input circuits. When connecting cables, ensure correct polarities. Do not apply a voltage to the analog output terminals from outside. Applying a voltage may cause hardware damage. 6-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 7 : Lower Terminals Alarm output terminals (AL1,AL2, ALCOM) Output relay contact capacity:125v AC 0.5A (Resistance load) 250V AC 0.1A (Resistance load) a-contact output; Common 1 2 3 AL1 AL2 ALCOM Figure 7-1 Alarm output terminals Hold (HOLD) When the hold terminal and the common terminal are short-circuited, measurement data and comparison output are retained. (Active L ) CAUTION The input is not isolated. Isolate using a mechanism such as a photo coupler and a switch. This is essential when the input is used in the floating mode. +5V 1mA max. Hold IN Lo Com Switch Photocoupler Figure 7-2 Hold terminal Model PCA13 - Universal Alarm Indicator 7-1

Lower Terminals Azbil Corporation Reset (RESET) When the reset terminal and the common terminal are short-circuited, the comparison output is reset. (Active L ) CAUTION The input is not isolated. Isolate using a mechanism such as a photocoupler and a switch. This is essential when the input is used in the floating mode. +5V 1mA max. Reset IN Lo Com Switch Photocoupler Figure 7-3 Reset terminal Common (COM) This common terminal is used for holding and resetting. Ground (GND) Connect the ground terminal directly to the ground if you anticipate frequent noise in the power line. The ground terminal need not be connected if external noise is not anticipated. However, ensure that the ground terminal does not come into contact with any other input terminal, since the neutral potential of the power supply is supplied to the ground. Power Supply(P1,P2) The supply voltage is specified on the terminal nameplate at shipping. Ensure that the supply voltage is within the range of 90 to 132V AC or 180 to 264V AC (50/60 Hz). 7-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 8 : Maintenance Maintenance CAUTION Store the product within the specified temperature range (-20 C to +70 C). To clean the front panel and the case, use a soft cloth and soapy water. Please do not allow water to enter the model PCA13. Wring the cloth well, and carefully wipe the front panel and case. Do not use such organic solvents as benzene and thinners as they may deform or discolor the case. Model PCA13 - Universal Alarm Indicator 8-1

Maintenance Azbil Corporation 8-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Chapter 9 : Calibration Procedure Introduction Calibration of resistance thermometer bulb range, thermocouple ranges, receiver range and analog output are necessary. To calibrate the resistance thermometer bulb range or the thermocouple ranges, select either C or F. No other ranges need calibration. Calibration Procedure Turn on the power while holding down MODE. CAL will be displayed after a lamp test is performed. The model PCA13 will then be in the calibration mode. While pressing, calibrate according to the following procedure: Calibration of resistance thermometer bulb range 1 Set the RANGE switch to 1 or 7. 2 Press MODE, and DP0 and DP1 will blink, indicating that the model PCA13 is ready for ZERO calibration. Input a Value of ZERO and press will be saved.. The display will blink and the ZERO value 3 Press MODE and DP2 and DP3 will blink, indicating that the model PCA13 is ready for MAX calibration. Input the MAX value and press will be saved.. The display will blink and the MAX value 4 To execute calibration again, press MODE. The model PCA13 will become ready for ZERO calibration again. Proceed to the next range for calibration, and operate the RANGE switch. To terminate calibration, turn off the power. Resistor A 3 B 4 B 5 Model PCA13 Main unit Figure 9-1 Connection diagram 1 Model PCA13 - Universal Alarm Indicator 9-1

Calibration Procedure Azbil Corporation 1) Calibration of thermocouple range (2 to 6 or 8 to C) It is necessary to calibrate the individual sensors and the reference junction compensation circuit. 1) Thermocouple range or temperature calibration. 1 Calibrate the ZERO and MAX for R,K,J,T and B sensors. Set the RANGE switch to 2 to 6 or 8 to C. 2 Press MODE, and DP0 and DP1 will blink, indicating that the model PCA13 is ready for ZERO calibration. Input a value of ZERO and press will be saved.. The display will blink and the ZERO value 3 Press MODE, and DP2 and DP3 will blink, indicating that the model PCA13 is ready for MAX calibration. Input the MAX value and press will be saved.. The display will blink and the MAX value 4 To execute calibration again, press MODE. The model PCA13 will become ready for ZERO calibration again. 5 Repeating steps 1 through 4, calibrate the thermocouple ranges that need calibration. 6 Proceed to the calibration of the reference junction compensation circuit in item 2). Generator + 1-2 Model PCA13 Main unit Figure 9-2 Connection diagram 2 9-2 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Calibration Procedure 2)Calibration of reference junction Compensation circuit. Choose one of the sensors (R,K,J,T, and B ( C or F)) for calibration. 1 Choose one sensor by setting the RANGE switch to it. 2 Press SHIFT, and DP1 and DP2 will blink, indicating that the model PCA13 is ready for calibrating the reference junction compensation circuit. Input a Value of ZERO and press switch, select calibration of sensor or ref- will be saved. (Holding down the SHIFT erence junction compensation circuits.). The display will blink and the ZERO value 3 Proceed to the calibration of another range, and set the RANGE switch to that range. To terminate calibration, turn off the power. Generator +Cu Sensor 1-2 Ice water Model PCA13 Main unit Figure 9-3 Connection diagram 3 Table 9-1 Range ZERO value MAX value 1 Pt100 C 0 C (100.00Ω) 649.0 C (329.64 Ω) 2 R C 0 C (0.00 mv) 1749 C (20.864 mv) 3 K C 0 C (0.00 mv) 1349 C (54.104 mv) 4 J C 0 C (0.00 mv) 899 C (51.815 mv) 5 T C 0 C (0.00 mv) 399 C (20.810 mv) 6 B C 0 C (0.00 mv) 1799 C (13.580 mv) 7 Pt100 F 32 F (100.00Ω). F (329.64 Ω) 8 R F 32 F (0.00 mv) 3180 F (20.864 mv) 9 K F 32 F (0.00 mv) 2460 F (54.104 mv) A J F 32 F (0.00 mv) 1650 F (51.815 mv) B T F 32 F (0.00 mv) 750 F (20.810 mv) C B F 32 F (0.00 mv) 3270 F (13.580 mv). : 000.0 flashing Model PCA13 - Universal Alarm Indicator 9-3

Calibration Procedure Azbil Corporation Receiver Calibration 1 Set the RANGE switch to D. 2 Press MODE and DP0 and DP1 will blink, indicating that the model PCA13 is ready for ZERO calibration. Input a value of ZERO and press will be saved.. The display will blink and the ZERO value 3 Press MODE, and DP2 and DP3 will blink, indicating that the model PCA13 is ready for MAX calibration. Input the MAX value and press will be saved.. The display will blink and the MAX value 4 To execute calibration again, press MODE. The model PCA13 will become ready for ZERO calibration again. Proceed to the next range for calibration and operate the RANGE switch. To terminate calibration, turn off the power. Generator + 6-7 Model PCA13 Main unit Figure 9-4 Connection diagram 4 Range ZERO value MAX value 1 Receiver Offset display (1V or 4mA) Full scale display (5V or 20 m A ~Note The offset value of the selected mode should be input for ZERO calibration. The full scale value of the selected mode should be input for MAX calibration. 9-4 Model PCA13 - Universal Alarm Indicator

Azbil Corporation Calibration Procedure Analog output adjustment 1 Set the RANGE switch to E. 2 Press MODE and DP0 and DP1 will blink, indicating that the model PCA13 is ready for ZERO calibration. Using the and switches, adjust the ammeter indication to the rated output (4.00mA±0.01 ma). Press, and calibration will be executed after the display blinks. 3 Press MODE and DP2 and DP3 will blink, indicating that the model PCA13 is ready for SPAN calibration. Using the and switches, adjust the ammeter indication to the rated output (20.00mA±0.01 ma). Press, and calibration will be executed after the display blinks. 4 To execute calibration again, press MODE. The model PCA13 will become ready for ZERO calibration again. Proceed to the next range for calibration, and operate the RANGE switch. To terminate calibration, turn off the power. Ammeter + 8-9 Main unit Figure 9-5 Connection diagram 5 Model PCA13 - Universal Alarm Indicator 9-5

Calibration Procedure Azbil Corporation 9-6 Model PCA13 - Universal Alarm Indicator

Document Number: Document Name: CM2-PCA100-2001 Universal Alarm Indicator Model: PCA13 User s Manual Date: 1st edition: Apr. 1996 4th edition: Aug. 2012 Issued/Edited by: Azbil Corporation