Light Matters. A Practical Guide to Evaluating LED Light Output

Similar documents
Optics Matter. Delivering the right light

Evaluating Light Output

High intensity LEDs. Aluminum with enamel finish. UL/cUL, CE

High intensity LEDs. UL/cUL, CE

ReachElite 100, 200, 300. Product Guide Delivering Light where you need it

icolor COVE SPECIFICATIONS output range Two-piece vented plastic C-UL US Listed, CE certified COMMUNICATION SPECIFICATIONS ELECTRICAL SPECIFICATIONS

EvenBalance. ew Powercore. EvenBalance. Unprecedented uniformity and consistency for demanding white-light applications

Optibin. Achieves color consistency with industry-leading LED optimization

ColorGraze QLX Powercore - Performance linear exterior LED wall grazing luminaires with RGB light

daylight Spring 2014 College of Architecture, Texas Tech University 1

icolor Cove MX Powercore Premium interior linear LED cove and accent fixture with intelligent color light

ArchiPoint. Product Guide. Get the Best and the Brightest. By day or night, ArchiPoint delivers an exceptionally powerful point of LED light.

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

GUIDELINES FOR GOOD EXTERIOR LIGHTING PLANS

LuxiGen Platform ENTERTAINMENT LIGHTING ARCHITECTURAL LIGHTING HIGH-END INTERIOR SPACES UV CURING INFRARED ILLUMINATION HORTICULTURE & SPECIALTY

ew Accent Compact High resolution media direct view linear LED fixture with solid white light

1.4 Rollins Center Performance Hall

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

NOT SO SCARY LIGHTING MATH

Lighting Terminologies Introduction

Flex. Product Guide. Get the Point. Cover almost any structure with bright points of color or white LED light in flexible strands

LIT-2. Lighting Philosophy

EXTERIOR LIGHTING DESIGN

APPENDIX GLOSSARY OF TERMS

Existing Lighting Conditions

MODA MINI COVE INTERIOR DYNAMIC WHITE

VAYA Free Form. Product Guide. Free Form Flexibility

15-06 Morlot Avenue, Fair Lawn, NJ USA Tel: (201) Fax: (201)

MODA MINI GRAZE INTERIOR GLOWDIM SPECIFICATION. Client: Project Name: MODA Contact: Quantity: PO#: Type: Notes:

Community Design Standards

Cold-Cathode Lighting and LED Lighting for Indirect Cove Applications: A Comparison. Today s Lighting Environment. Effective Cove Lighting

SKU: Tested by Intertek to UL1598 for use in USA & Canada. CE Approved. WEE. RoHS Compliant. TM Tested. US Patent No. D787,112 and D783,890.

Vaya Cove LP, White & Mono

A revolution in lighting

Lighting for seniors

Use timers, motion detectors, remote controls, and photocells to reduce waste.

Energy and Calculating Light. Lighting Needs Power: Electrical Systems. Lighting Needs Power: Wires Distribute Electricity

MODA MINI COVE INTERIOR GLOWDIM PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Notes: Miniature Line Voltage Cove Fixture.

MUNICIPAL OUTDOOR LIGHTING STANDARDS FOR THE CONTROL OF LIGHT POLLUTION

Round 11 Retailer Synopsis

Second Floor Circulation

ALTERNATIVE LIGHTING DESIGN

LdG-2 Lighting design Guide for Vertical Surfaces

Lighting Depth: Physical Therapy Suite Franklin Care Center, Franklin Lakes, NJ

Ordexum LED WALL & STEP LIGHT

MODA MINI COVE INTERIOR GLOWDIM SPECIFICATION. Client: Project Name: MODA Contact: Quantity: PO#: Type: Notes:

LED Recessed Lighting

Click to navigate. LED Panels. Light Engines. Click to return

An Introduction to Interior Lighting Design

NOT SO SCARY LIGHTING MATH NOT SO SCARY LIGHTING MATH

XOOLINE. The linear Allrounder

General Information 11A-1. A. General. B. Industry Outlook. Design Manual Chapter 11 - Street Lighting 11A - General Information

LYRA THE UNIVERSAL LIGHTING TOOL. Lobby 520 Broadway, Los Angeles Architect: Wolcott Architecture I Interiors Photo: Lane Barden

Project: EIR for Carondelet High School Sports Complex

LLNF-3T11-H LLFL-3T11-H

AmphiLux. Light up your outdoor social areas

LZ1-00WW05. LedEngin, Inc. High Luminous Efficacy Warm White LED Emitter. Key Features. Typical Applications. Description

Recommendations for Testing and Evaluating Under-cabinet Luminaires

LLNS-2T06-H, LLNF-2T06-H, LLFL-2T06-H

Accento. Powerful LED Accent and Feature light range

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

MODA MINI COVE INTERIOR DYNAMIC WHITE

LIGHTING Common terminology 2. Sources and luminaires 3. Controls

PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light.

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

The versatility to light all types of public and professional environments

Energy Efficiency in Homes

Section 27.5 Outdoor Lighting

Calculite White LED 4 " Adjustable Accent. Professional-grade downlighting

Upgrading T8 Fluorescent Lighting in Factory Production Environments. An Economic Comparison of T5 Fluorescent and LED Lighting Options

PL TR3 RGB High Output Floodlight

ARCHISHAPE Washer Datasheet

Progressive lighting portfolio

Microfilm and Reading Area

Basic Lighting Design Seminar

Basic lighting quantities

Correct cap type? e.g. Bayonet Edison Screw GU 10 MR 16. Suitable colour temperature? Warm (3000 K) Cool (4000 K) Bright White (5000+ K)

Bridgelux Vesta Series Tunable White 9mm Array. Product Data Sheet DS152

A R C H I T E C T U R A L OUTDOOR LIGHTING

spacing, efficiency, uniformity, and aesthetic appearance of light patterns for final design for the construction document phase.

G2 High Output Linear Accent

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LIGHTING Common terminology 2. Sources and luminaires 3. Controls

The Bahen Centre for Information Technology. Lecture Hall Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

Another great leap forward

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

PAYBACK STARTS NOW INDUSTRIAL LIGHTING PRODUCT CATALOG

Arch 464 ECS Midterm I Spring Multiple Choice Questions

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Sun Energy LED Lighting

CELESTIAL CORONA LOW VOLTAGE LINEAR LIGHTING

DARK SKIES ORDINANCE

How to Select Residential LED Directional Lighting

Arch 464 ECS Midterm I Spring Multiple Choice Questions

Cove Light AC HO RGB Graze

PARATHOM PAR16. Product family datasheet. LED reflector lamps PAR16 with retrofit pin base

Can the present white LEDs cater to the lighting needs?

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Slender elegance, powerful luminance. Linear

Northwest façade of building

Transcription:

Light Matters A Practical Guide to Evaluating LED Light Output Light Matters

Delivered Light The Right Way to Measure LED Output Traditional methods of evaluating light focused on lumen output, which defined by the output capabilities of a light source, such as an incandescent lamp. The advent of LED lighting changed all that, since lumens were no longer the best measurement of a luminaire s capabilities. Now the more accurate, relevant measurement is delivered light, which determines and records illuminance, the amount of light falling on a surface area. Measuring light output has shifted from testing the lighting fixture in a lab environment to measuring how light actually falls on the chosen surface in the real world. What does this mean for lighting professionals? Delivered light is the best way to evaluate whether a luminaire will deliver the right amount of light and the proper color for a specific task. Photography: Philips 2

3

Defining how we evaluate light It s important to know the various terms used to describe light. Light output is an informal term for how much light a luminaire produces, and how it emits and distributes light. Photometrics is the formal term for data describing the quantity and distribution of the visible light produced by a light source or fixture. Manufacturers report key photometrics about luminaires via online specification sheets or data sheets. These statements usually include basic charts and graphs that describe the power or intensity of a lamp or light fixture, the way it distributes light in space or over an area, and its energy efficiency. Lighting specifiers, designers, and other lighting professionals use this data to make preliminary evaluations of a luminaire s capabilities and its potential suitability for a particular task or lighting application. Manufacturers often make more detailed information available for deeper analysis, creating computer renderings, building mock-ups, and more. It s important to note that much of this information focuses on the luminaire itself, not the area or structure being illuminated. Lumen output vs. brightness The specification most commonly used for evaluating and comparing the performance of conventional lighting fixtures is lumen output. Technically, a lumen is the measure of the total quantity of visible light emitted by a specific light source. But in practice, lighting professionals, purchasers, and users often refer more casually to a fixture s brightness. This designation is not only inaccurate, but also misleading, especially when evaluating LED lighting fixtures. Lumen output in the LED era There are many valid reasons why lumen output is not the best measurement of an LED luminaire s capabilities (see page 8). Evaluating an LED luminaire solely or primarily on the basis of its lumen output can underestimate or otherwise give a distorted picture of the fixture s performance and suitability for a given task or application. Delivered light defined Instead of lumen output, the best and most relevant measurement for evaluating LED lighting fixtures is delivered light. The formal term for measurements of delivered light is illuminance. Generally defined, illuminance is the amount (or quantity) of light falling on a surface area. If the area is measured in square feet, the unit of illuminance is footcandles (fc). If measured in square meters, the unit of illuminance is lux (lx). While delivered light describes how much useful light a lighting fixture can deliver to a task area, useful light is the portion of a luminaire s light output that is effectively directed to a task area, discounting any wasted light. One way to think of illuminance is that it s the density of light upon a surface. Generally, the denser the light on an object, the brighter that object will appear. Lumens can be envisioned as the total quantity of light, without describing directionality and the resulting density. Density as measured by illuminance is the most important factor when specifying light. If you are putting light in a defined location (e.g., a library reference room), enabling a specific task (e.g., reading), you need to know if there will be the right amount of light to perform that task now and in the future. This definition of illuminance covers any space or surface that needs to be illuminated, from an entrance hallway to a retail environment to an iconic building or national monument, such as the Eiffel Tower or the Empire State Building. 4

Photography: Xavier Boymond 5

6 Photography: Philips

Evaluating delivered light Historically, lighting designers described fixtures by their wattage to serve as the basis for comparison of brightness. At the beginning of the LED era, manufacturers started to highlight cd/w and center beam footcandles as a way to define how much light could reach the side of a building. This limited approach ignores beam quality and does not address application efficiency. It also ignores the total power needed to light the space to the specified footcandles, as well as the uniformity to ensure maximum usability of the space being illuminated. The real measure of application uniformity is the total wattage for the delivered footcandles of the space, or fc/w. This measurement factors in lumens, beam shape, system losses and the efficacy of the luminaire, including optical, thermal, electrical, and control as well as the distance and placement of the luminaires. Beam and application uniformity must be considered in conjunction with fc/w when evaluating luminaires for a specific application. Typically, as the footcandles rise, illuminance uniformity lowers. Color and beam uniformity also need to be evaluated to ensure that color and beam non-uniformities do not distract from the design intent or the ability to maximize use of the given space. How can light be wasted? Light can be wasted in a number of ways. It can be partially blocked or dispersed within the fixture housing, emitted in a direction away from the task area, or lost through filtering, lensing, fixture positioning, or any of a number of other factors relevant to a specific installation. Light can also be partially directed to a surface not intended to be illuminated. And if beam quality and color quality are poor, more luminaires will be needed to meet minimum application requirements. The issue of wasted light remains an important issue when evaluating luminaires and their suitability for various applications. Do manufacturers highlight how much light their luminaires waste? Probably not, leaving lighting professionals with an incomplete picture of a luminaire s real-world capabilities. Reducing misdirected light Trespass/spill light is a related issue that comes into play in outdoor environments one addressed by efforts such as the Dark Sky Association. This group and others encourages lighting manufacturers and designers to produce fixtures and designs with no wasted light. In short, the goal is to put light where it s needed, so it doesn t affect the visual environment. Philips Color Kinetics supports this effort with improved luminaire and design efficiency that maximizes fc/w ensuring that light is delivered where it s intended. Delivered Light: How many footcandles do you need? A review of The IESNA lighting Handbook, the 900-page standard reference work from the Illuminating Engineering Society of North America (IES), reinforces the importance of delivered light as an appropriate way to measure light, especially for white-light and everyday applications. Along with chapters that describe in detail how to deliver the right amount of useful light in an application, the Handbook includes an extensive lighting design guide that specifies ideal light levels for every conceivable interior, industrial, outdoor, sports, transportation, and emergency lighting application. For example, the Handbook recommends a delivered light level of around 30 footcandles (300 lx) for an open plan office with extensive computer use, as well as for the ticket counter of a transportation terminal. Freight elevators should have a level of around 5 footcandles (50 lx), while serious reading in a chair at home requires a level of around 50 footcandles (500 lx). Lecture halls where demonstrations are being performed should have a light level of around 100 footcandles (1000 lx). These measurements confirm that delivered light is the critical measurement for evaluating light. And different applications require different amounts of delivered light. 5 fc (50 lux) 30 fc (300 lux) 50 fc (500 lux) 100 fc (1000 lux) 7

The Trouble with Lumens? They Don t Apply in an LED World. Lumen output the traditional method of measuring, reporting, and interpreting light poses many potential problems when evaluating and comparing LED lighting fixtures. Here are just a few of the key issues. New Standards LM-79 an accepted standard for photometric testing for LED luminaires fundamentally changed how lighting designers understand photometric measurements and eliminated the need for common light loss factors (LLF) to be included in calculations. This IESNA document establishes the procedures that photometric laboratories must follow to test LED luminaires, and report the findings. Confusing Terms Complex, similar-sounding terms, such as luminance and illuminance, make understanding photometrics challenging, and can create confusion when evaluating and understanding the unique properties of LED lighting sources. Optics Matter Even if two luminaires are measured as providing the same lumens, they may not result in the same illuminance. Why? Because one may have narrow optics that deliver highdensity light to a small area, while the other may have broad diffusion optics that apply a small density of light over a very large area. Different optics deliver very different results, and must be considered carefully during design. luminaire that was actually measured. Or they may provide a test from a single variation of multiple options. These manufacturers often provide IES files, where the admission of calculation is only included in the header if you open the.txt file. When using lighting design programs such as AGI32, you may not even notice this information is included in the file. This inaccurate (and potentially deceptive) practice is fairly commonplace, almost as common as providing estimated measurements of early LED luminaires. To rectify this situation, all IES files provided by Philips Color Kinetics are measured and certified in laboratories using a representative fixture from our manufacturing line providing accurate estimations of the performance lighting designers can expect. Illuminance Footcandles per square foot (fc) LUX per square meter Difficult Comparisons Conventional lighting fixture manufacturers often report total lamp lumens more prominently than (or instead of) total fixture lumens. Some even talk about the LED s potential LED wattage, avoiding how it s implemented in the luminaire design, and the resulting output and efficacy. Because many LED light sources do away with the distinction between lamp and luminaire, only total fixture lumens can serve as a basis for valid comparisons between lighting fixtures. Luminance Candella per meter squared (cd/m 2 ) Varying Testing and Reporting Many manufacturers still do not provide certified measurements for all luminaire varieties. Instead, they may offer calculated photometrics, which describe results that are scaled simply by the expected design not from a test 8

Photography: Anthony Masters Photography 9

Philips Color Kinetics Committed to Maximizing and Optimizing Delivered Light. Providing exceptional delivered light isn t a function of simply boosting the power or number of LED light sources. It s the direct result of smart decisions at every stage of design and development, as well as manufacturing. Philips Color Kinetics offers a wide range of luminaires, each designed to maximize delivered light. In short, the kind of bright, consistent light that makes lighting professionals and their clients very, very happy. And the kind of light that looks just as exceptional in the real world as it does in simulations. Philips Color Kinetics luminaires deliver highly uniform, high-quality white light to support a range of business, retail, hospitality, and other applications. And they can transform spaces with intensely saturated, dynamic accent and fullcolor effect lighting for dramatic presentations, theatrical atmospheres, and special occasions and events. 10

Here are just some of the Philip Color Kinetics innovations that make exceptional results a reality: Optimized LED Selection: Bright from the Start Optibin, our proprietary binning process, ensures color consistency and consistent delivered light by grouping (binning) LEDs by flux, as well as chromaticity/colorpoint. Optibin uses an advanced bin selection formula that exceeds industry standards for chromaticity to guarantee uniformity and consistency for Philips Color Kinetics lighting products. With Optibin, our luminaires deliver bright, consistent light right from the start and throughout long use. Advanced Optics: Unequaled Expertise Philips Color Kinetics makes a major ongoing investment in optical research, creating innovative optics that meet the varying and evolving needs of the marketplace. Our range of optics are optimized for the specific LED, ensuring higher illuminance with the same power. We create unique beam shapes ideally suited for specific applications including grazing, forward throw, flood, washing, direct view, spot, cove, indirect illumination, and task lighting. The result? Our advanced optics provide exceptional delivered light, precisely where it s needed with minimal waste and maximum punch, as well as greater efficiency. And we can even create custom optics to meet specialized needs. Color Quality and Mixing: Optimized Color Optics also play a key role in achieving high color quality and precision mixing. For example, our PureStyle interior linear LED luminaire features a unique optical cluster that enables narrow beams and reduced mixing distances. And our ColorBurst Powercore spotlighting luminaires integrate a family of specially designed optics to optimize color mixing in the far field beam. Competitive solutions that use the same optics for the RGB channels often exhibit a red ring. Chromasync: Advanced Color Consistency Chromasync capability is available on many Philips Color Kinetics LED lighting systems, enabling them to achieve advanced color consistency. The Chromasync color control algorithm outputs the maximum possible flux based on the color command by managing how best to use the multiple channels and color LEDs inside the fixture. The result? Optimized, greatlooking, accurate light delivered with accuracy and efficiency. 11

Delivered Light Portfolio The ever-expanding range of diverse lighting projects and environments makes designing and implementing lighting challenging, as well as rewarding, since no two installations are exactly the same. Each situation creates different illumination requirements from residential to retail to public lighting. However, all share the need for delivered light in the right amount and quality. Here we present a portfolio of realworld examples, highlighting the specific delivered light challenges for each situation, as well as the Philips Color Kinetics innovations that meet those challenges. 12

Photography: Ammar Keylani 13

1 Wall-washing white light The challenge: Even illumination of a large multi-story shape or facade. The solution: ew Blast Powercore gen4 The innovations: Our solution delivers a high-quality beam of white light, free from beam striations. Easyto-use controls simplify installation and reduce complexity and cost. Photography: Redshift Photography 14

Increasing impact and safety 2 The challenge: To increase light levels and uniformity increasing safety, reducing maintenance and energy costs, and revitalizing San Diego, California. The solution: ColorBlast IntelliHue Powercore gen4 and ColorBlast Powercore gen4, RGB The innovations: Our solution enables the city to brand itself with dynamic color light, while provide safe urban lighting at all times. Photography: Juan Ceballos and Debra Fox 15

3 Uniform illumination The challenge: Provide powerful and uniform illumination of the unique fan-like geometry of the Sony Center roof in Berlin, Germany. The solution: ColorReach Powercore gen2 and ColorBlast Powercore gen4 The innovations: Our solution delivers subtle shades of light and high punch to a complex architectural detail - creating powerful visual impact in a high-traffic area. Photography: Courtesy of Alexander Weckmer Licht und Mediensysteme GmbH 16

Lighting a textured surface 4 The challenge: Light a textured wall without much room for a standard interior linear luminaire. The solution: PureStyle The innovations: Innovative optics enable PureStyle to be installed extremely close to the surface being illuminated. This short throw distance helps conceal the source of the light, enhancing the effect. Photography: Claus Logstrup 17

5 Interactive light show The challenge: Create an interactive, engaging installation to draw people to the parks of the San Isidro district, Lima, Peru. The solution: icolor Flex gen2 and a unique control solution allow people to create and experience memorable lighting effects. The innovations: Interactive controls allow visitors to experience light in a whole new way. Photography: Courtesy of Claudia Paz Studio 18

Large-scale grazing The challenge: Grazing a large object or architectural detail from the ground. The solution: ColorReach Compact Powercore, RGBW The innovations: Simple control and installation design uses a single row of ColorReach Compact Powercore, RGBW to illuminate more than 10 stories of this iconic building in Dallas, Texas. 6 Photography: Justin Terveen 19

7 Even wash lighting The challenge: Even wash lighting to illuminate a large, 400-foot building facade. The solution: ew Reach Powercore gen2 The innovations: This solution provides a consistent look to the complex façade, day or night. More compelling, memorable lighting helps differentiate this site from similar buildings in the area. Photography: Darius Kuzmickas 20

Highlighting an historic landmark 8 The challenge: Turning an overlooked part of Brockville, Ontario, Canada into a safe, energetic and vibrant attraction. The solution: ColorGraze MX4 Powercore and ColorBlast Powercore gen4 The innovations: Our luminaires transform a 1722 ft (525 m) long tunnel into a visually stunning walkway. Grazing luminaries showcase the unique architectural and geological features. Photography: Philips 21

9 Revealing architectural details The challenge: Creating a destination for business and retail stores, helping attract pedestrians to this part of Philadelphia. The solution: ColorGraze MX4 and ColorBlast Powercore gen4, RGBW The innovations: Precise grazing highlights beautiful architectural details in subtly shaded light, without spilling distracting light into the interior of the building. Photography: Jeffrey Totaro, 2016 22

Philips Color Kinetics Delivers Light and Much More Delivered light is just one critical area where Philips Color Kinetics excels. Find out more about our technological innovations in tunable white, color, and dynamic color light. And explore our extensive and everexpanding selection of luminaires in wideranging form factors all designed to bring new innovation, excitement, and efficiency to today s lighting implementations. www.colorkinetics.com/learn 23

Copyright 2017 Philips Lighting Holding B.V. All rights reserved. Chromacore, the Chromacore by Color Kinetics CK Technology logo, Chromasic, the Chromasic by Color Kinetics CK Technology logo, CK, the CK logo, the CK Color Kinetics logo, the CK Intelligent Series logo, Color Kinetics, the Color Kinetics logo, PureStyle, EvenBalance, ColorBlast, ColorBlaze, ColorBurst, ColorCast, ColorDial, ColorFuse, ColorGraze, ColorPlay, ColorReach, ColorScape, DIMand, the DIMand by Color Kinetics CK Technology logo, EssentialColor, ecolor, EssentialWhite, ew, ew Cove, ew Downlight, ew Flex, ew Fuse, ew Graze, ew MR, icolor, icolor Accent, icolor Cove, icolor Flex, icolor Module, icolor Tile, IntelliHue, IntelliWhite, iw, iw Blast, iw Cast, iw Cove, iw MR, iw Profile, iplayer, Optibin, the Optibin by Color Kinetics CK Technology logo, Powercore, the Powercore by Color Kinetics CK Technology logo, and Vaya are either registered trademarks or trademarks of Philips Lighting Holding B.V. in the United States and / or other countries. All other marks are property of their respective owners. Photography: Ryan Fischer BRO-000114-00 R00 9-17 Philips Color Kinetics www.philips.com/colorkinetics