Core Technology Group Application Note 6 AN-6

Similar documents
Core Technology Group Application Note 1 AN-1

Core Technology Group Application Note 2 AN-2

Study of Inductive and Capacitive Reactance and RLC Resonance

Lab 9 Frequency Domain

Frequency Selective Circuits

Input Filter Design for Switching Power Supplies Michele Sclocchi Application Engineer National Semiconductor

Input Filter Design for Switching Power Supplies: Written by Michele Sclocchi Application Engineer, National Semiconductor

Filters And Waveform Shaping

FREQUENCY RESPONSE AND PASSIVE FILTERS LABORATORY

Invasive and Non-Invasive Stability Measurements

Making Invasive and Non-Invasive Stability Measurements

Filter Considerations for the IBC

Chapter 2. The Fundamentals of Electronics: A Review

Simulating Circuits James Lamberti 5/4/2014

Low Pass Filter Introduction

EECS40 RLC Lab guide

EK307 Active Filters and Steady State Frequency Response

Testing Power Sources for Stability

LABORATORY #3 QUARTZ CRYSTAL OSCILLATOR DESIGN

RLC Frequency Response

Department of Electrical & Computer Engineering Technology. EET 3086C Circuit Analysis Laboratory Experiments. Masood Ejaz

INTRODUCTION TO AC FILTERS AND RESONANCE

Experiment 8 Frequency Response

EE301 ELECTRONIC CIRCUITS

Welcome to your second Electronics Laboratory Session. In this session you will learn about how to use resistors, capacitors and inductors to make

Experiment 2: Transients and Oscillations in RLC Circuits

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

AC CURRENTS, VOLTAGES, FILTERS, and RESONANCE

Simulating Inductors and networks.

PURPOSE: NOTE: Be sure to record ALL results in your laboratory notebook.

Lab 1: Basic RL and RC DC Circuits

AC Measurements with the Agilent 54622D Oscilloscope

Class #7: Experiment L & C Circuits: Filters and Energy Revisited

Outcomes: Core Competencies for ECE145A/218A

PSPICE SIMULATIONS WITH THE RESONANT INVERTER POWER ELECTRONICS COLORADO STATE UNIVERSITY. Created by Colorado State University student

Figure 1a Three small inductors are show what inductors look like. Figure 1b Three large inductors

ECE 310L : LAB 9. Fall 2012 (Hay)

Worksheet for Exploration 31.1: Amplitude, Frequency and Phase Shift

Transformer modelling

The Series RLC Circuit and Resonance

BAKISS HIYANA BT ABU BAKAR JKE,POLISAS

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

ELC224 Final Review (12/10/2009) Name:

EK307 Passive Filters and Steady State Frequency Response

Exercise 1: Series RLC Circuits

Lab 4: Analysis of the Stereo Amplifier

Filter Design in Continuous Conduction Mode (CCM) of Operation; Part 2 Boost Regulator

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

Radio Frequency Electronics

ENGR4300 Test 3A Fall 2002

Fixed Frequency Control vs Constant On-Time Control of Step-Down Converters

Measuring Power Line Impedance

Chapter 19. Basic Filters

FREQUENCY RESPONSE OF R, L AND C ELEMENTS

Assist Lecturer: Marwa Maki. Active Filters

AC reactive circuit calculations

Chapter 31 Alternating Current

DC/DC Converter Stability Measurement

Passive Component Analysis. OMICRON Lab Webinar Nov. 2015

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

EE 221 L CIRCUIT II LABORATORY 4: AC CIRCUITS, CAPACITORS AND INDUCTORS UNIVERSITY OF NEVADA, LAS VEGAS OBJECTIVE COMPONENTS & EQUIPMENT BACKGROUND

AC Circuits INTRODUCTION DISCUSSION OF PRINCIPLES. Resistance in an AC Circuit

Methodology for testing a regulator in a DC/DC Buck Converter using Bode 100 and SpCard

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

ET1210: Module 5 Inductance and Resonance

Exercise 1: Series Resonant Circuits

EXPERIMENT 8: LRC CIRCUITS

Frequency Response of Common Emitter Amplifier

Understanding, measuring, and reducing output noise in DC/DC switching regulators

Electronics II. 3. measurement : Tuned circuits

CHAPTER 14. Introduction to Frequency Selective Circuits

DC/DC Converter Stability Measurement

ECE 2201 PRELAB 6 BJT COMMON EMITTER (CE) AMPLIFIER

Testing and Stabilizing Feedback Loops in Today s Power Supplies

Experiment 8: An AC Circuit

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

Pre-Lab. Introduction

Laboratory 4: Amplification, Impedance, and Frequency Response

High Current Amplifier

When input, output and feedback voltages are all symmetric bipolar signals with respect to ground, no biasing is required.

Department of Electrical and Computer Engineering Lab 6: Transformers

EXPERIMENT 1: Characteristics of Passive and Active Filters

EXPERIMENT 4: RC, RL and RD CIRCUITs

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

DC Biased Impedance Measurement

1) Consider the circuit shown in figure below. Compute the output waveform for an input of 5kHz

Background (What Do Line and Load Transients Tell Us about a Power Supply?)

AC Circuits. "Look for knowledge not in books but in things themselves." W. Gilbert ( )

DC/DC Converter Stability Measurement

15: AUDIO AMPLIFIER I. INTRODUCTION

New Technique Accurately Measures Low-Frequency Distortion To <-130 dbc Levels by Xavier Ramus, Applications Engineer, Texas Instruments Incorporated

SIMULATION OF A SERIES RESONANT CIRCUIT ECE562: Power Electronics I COLORADO STATE UNIVERSITY. Modified in Fall 2011

Experiment 1: Instrument Familiarization (8/28/06)

Equivalent Circuit Determination of Quartz Crystals

6.334 Final Project Buck Converter

STATION NUMBER: LAB SECTION: Filters. LAB 6: Filters ELECTRICAL ENGINEERING 43/100 INTRODUCTION TO MICROELECTRONIC CIRCUITS

Measurement of the equivalent circuit of quartz crystals

Figure 1: Closed Loop System

Application Note. Piezo Amplifier. Piezoelectric Amplifier Connection. accelinstruments.com

Contactless RFID Tag Measurements

Transcription:

Characterization of an RLC Low pass Filter John F. Iannuzzi Introduction Inductor-capacitor low pass filters are utilized in systems such as audio amplifiers, speaker crossover circuits and switching power supply designs. Audio systems use low pass filters to bypass power supply noise and to control surge currents. Speaker crossover systems, because of their high power requirement use LC filters to block low frequency power surges to the midrange and high frequency speaker sections. In many cases, the output filter of a switching power supply must use a custom wound inductor with a standard capacitor for optimal design and efficiency. Because of this, the filter must be completely characterized with all values and parasitic effects accounted for to insure the stability of the feedback control system. The parasitic effects include the DC resistance of the inductor and the ESR of the capacitor. This application note, along with AN-1 and AN-3 discusses a method for characterizing an RLC filter transfer function using the Circuit Sleuth Network/Impedance analyzer. Note from the Author. Commercial inductor and capacitor values are known for extremely wide tolerances. A concern is the use of these components in control systems where designs must be extremely robust, sacrificing bandwidth/performance for stability because of the inductor and capacitor tolerance stack up. Additionally, it also leads to the conclusion among engineers that it is impossible to get the measurements to agree closely with the theoretical calculations or the results of a simulation. Because of this, theoretical calculations and simulations are never performed because they are deemed unreliable. This application note was written to illustrate that when the actual components are characterized, accurate theoretical predictions and simulations are possible. This does not exclude the fact that the designs must also be built, tested and compared to the theoretical models. By this, the design has increased reliability, improved quality and outstanding performance. RLC filter transfer function, Vout/Vin Figure 1 represents an RLC filter along with some series damping resistance and an external sine wave voltage source. - 1

Vin R L Vout C Figure 1. Schematic of RLC low pass filter. The classic transfer function of the RLC filter is a second order system that is described mathematically as: Vout Vin s 2 2 ω 2 + 2ξω s + ω (1) where: ω 2 1 LC (2) and 2ξω R L (3) Where R,L and C are the component values, s is a complex vector, ω is the angular frequency and ζ is the damping factor. The damping factor resistance is included as a single resistance. This resistance is serving as a placeholder for the parasitic resistances that are always physically present in an inductor and a capacitor. The parasitic resistance present in an inductor is its DC resistance. This resistance is dependent on the amount of copper present in the inductor winding. It is dominant at relatively low frequencies and can be measured at the low frequency end of the inductor s impedance curve. The parasitic resistance of a capacitor is called the equivalent series resistance, or ESR. The ESR of a capacitor is dominant at the high frequency end of a capacitor s - 2

impedance curve. In the following sections, both the inductance value and capacitor value, along with their associative parasitic resistances, will be characterized and placed into the circuit model. Since both of the parasitic resistances are in series, they will be lumped together and represented as a single resistor for the analysis. Measuring the inductor, L AN-1 details the techniques used for measuring the impedance of an inductor. The same techniques were used to measure the inductor for this application note. The Circuit Sleuth virtual front panel results for that inductor are shown in figure 2. The inductance value is calculated from the magnitude. The magnitude is 5.38 ohms @ 10 KHz. Mag 5.38 L 85.7µ H 2π f 2π 10000 (4) The resistance associated with the copper loss in the inductor windings or DC resistance is measured as 0.04 ohms @ 200 Hz. - 3

Figure 2. Test results of an 85 uh inductor. The cursor is positioned at 10 KHz. The magnitude (RED) @ 10 KHz is 5.38 ohms. Measuring the capacitor, C AN-3 details the techniques used for measuring the impedance of a capacitor. The same techniques were used to measure the capacitor for this application note. The Circuit Sleuth virtual front panel results for the capacitor are shown in figure 3. The capacitance value is calculated from the magnitude. The magnitude is 19.05 ohms @ 10 KHz. C 1 1 0.84 F 2π f Mag 2π 10000 19.05 µ (4) - 4

The resistance associated with the capacitor ESR is measured at about 3.2 ohms @ 0.9 MHz. Figure 3. Test results of a 1 uf electrolytic capacitor. The cursor is positioned at 10 KHz. The magnitude (RED) @ 10 KHz is 19.05 ohms. Adding values to the filter model Figure 4 illustrates the model of the RLC filter with the component values as determined by the preceding impedance measurements. - 5

Vin 0.04 ohm Rs 85.7uH L Vout C 0.84uf Resr 3.2 ohm Figure 4. RLC filter with component values. Since Rs and Resr are in series with the circuit, they can be added together and represented as a single resistor, R. This is shown in figure 5. Vin 3.24 ohm R 85.7uH L Vout C 0.84uf Figure 5. RLC filter with R represented as a lumped value of Rs + Resr. It is now possible to calculate the resonant frequency and the damping factor of the filter. Resonant frequency: ω 1 LC 1 118170.76rad / sec 6 6 85.7 10 0.84 10 (5) f ω 817KHz 2 π 18. (6) Damping factor: - 6

ξ R 3.24 2ωL 2 118170.76 85.7 10 6 0.16 (7) Measuring the filter The test setup for measuring the transfer function of the RLC filter is shown in figure 6. It is also useful to connect an oscilloscope to the output of the source to observe the frequency sweep as the test progresses. Note that the resistance, R, is actually the parasitic resistances of the capacitor and inductor. IT IS NOT AN ACTUAL RESISTOR TO BE CONNECTED. TM1 The Sleuth Data Power Input A +4dBm (1vpp) Input B +4dBm (1vpp) Va Lumped parasitic resistance Vb Output ( 50 ohm) Sleuth SA-40 Network/Impedance Analyzer TM2 Terminator 50 ohm 3.24 ohm R 85.7uH L C 0.84uf Figure 6. Test setup to measure the transfer function of the RLC filter, with the parasitic resistance, R, shown. Figure 7 illustrates the Circuit Sleuth virtual front panel in the ratio (B/A) measurement mode. The controls located under the PARAMETERS tab are used to set the analyzer up for the desired frequency range, number of test points, excitation signal amplitude, etc. As shown, measurements were taken over the frequency range of 100 Hz to 1 Mhz with a logarithmic frequency and magnitude scale. - 7

In this mode, the magnitude and phase (bode diagram) of the system response is displayed. This is also known as the system transfer function. The transfer function shows the output/input relationship of the system over frequency. The magnitude is best represented in decibels and the phase in degrees. This particular filter is very flat in the pass band, peaks at resonance and rolls off at the high frequency end. Adding additional damping resistance will attenuate the resonant peak. As mentioned in the introduction, in switch mode power supply design, it is very important to know the transfer function of the output filter because it can significantly affect the stability of the feedback control system that regulates the output voltage. The cursor is placed at the peak point in the transfer function. This is the filter s resonant frequency. The measured frequency of resonance is about 18.2 KHz and is within 3.2% of the calculated frequency of 18.8 KHz. Not bad! Figure 7. Virtual front panel output displaying the transfer function, magnitude and phase, of the RLC filter. Figure 8 illustrates the magnitude vs. normalized frequency at various damping factors. The calculated damping factor of 1.6 compares favorably to the magnitude measured at the resonance frequency of about 8.3 db. - 8

Figure 8. Magnitude vs. normalized frequency for various damping factors. Summary This application note showed how to measure and verify the transfer function of an RLC low pass filter. Theoretical calculations were performed initially using the standard second order system transfer function to find expressions for the frequency of resonance and the damping factor of the filter. The characteristic impedances of the inductor and the capacitor were measured and the parasitic resistances of those components were lumped together in series to form the damping resistance of the filter. The transfer function of the filter was characterized with a network analyzer. The frequency of resonance and the - 9

amplitude in db at the point of resonance was measured. The measured resonance frequency was within 3.2% of the calculated value. The damping factor was estimated using the measured amplitude peak in db of the magnitude curve at the point of resonance and comparing that magnitude to a normalized chart. It was determined that the calculated damping factor of 1.6 compared favorably to that indicated on the chart. - 10