ELECTROAIR. Aeronautic and military cables High mechanical and temperature performances

Similar documents
WIRE & CABLE. 99 Wire Low fire hazard wire and cable

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

TYGADURE FOR EXTREME APPLICATIONS

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

High Performance Wire and Cable

WIRE & CABLE. 55 Wire High performance wire and cable

Spec wire. Performance Wire and Cable

Wire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits

SPEC 44. Wire and cable

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Railway products. Edition 2014

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

SAC-3P- 5,0-PUR/M12FR SH

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

Tri-Rated Flexible PVC Equipment Wire

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

RGCoaxials RG, low noise and sub-miniature coaxials

SAC-5P- 1,5-PUR/M12FS SH

High Performance Wire and Cable SPEC 55. Product Facts. by hot stamp, ink jet or laser, and can be potted without pre-etching.

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Welding Cables Rubber Insulated

Aircraft Wires and Cables

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

Field Instrument Cable. Electrical Noise

ABOUT US ABOUT US 1 CRANE CABLES

Mineral-insulated resistance thermometers to EN

Times Microwave Systems Hermetically Sealed Assemblies

MEDIUM VOLTAGE

Broadband performance with low reflection DC to 4 GHz provides low cost connector combined with high quality.

Amphenol RF UHF. UHF Connector Series UHF. Description. Features/Benefits. Applications

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

RADIALL DETAIL SPECIFICATION FOR SHF COAXIAL CABLE

kv: medium voltage reeling cable with fibreoptics

LTE high-performance coaxial cables (RG replacement)

Amphenol RF MCX. MCX Connectors MCX. Description. Features/Benefits. Applications

UNIRAIL D RS485 and BUS cables

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Chord Crimson VEE 3. Chord Cobra VEE 3. Chord Chameleon VEE 3. Chord Cadenza Reference. Chord Chorus Reference. Chord Anthem Reference

Kerman & Kavian Cable Industries ( KCI )

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

GORE Aerospace high speed data cables

(12) Patent Application Publication (10) Pub. No.: US 2015/ A1

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

SERV-RITE Wire. Thermocouple and Extension Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Connection technology for wireless communication systems

Continuous Flex Data Cable

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

ST0057 Date: 9 Sept The Ultraviolet (UV) Laser Marking Performance of Common Aerospace Wire and Cable Constructions

GANPATI ENGINEERING INDUSTRIES Braided Copper Wire

COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES

COPPER + LWL RAW CABLES

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Partnering ideas with technology THEORY AND APPLICATION

Servo Cable Selection

EACON. Field mountable microwave cable. INEXIM Sp. z o.o. Edition Bezpośredni importer i dystrybutor

Creating. There is one basic question every customer needs to address when creating custom

General Information and Selection

Product Information Measuring resistor with the Pt100-sensor referring to DIN EN Pt100, Pt500, Pt1000

Amphenol RF. MMCX Micro-Mate (MMCX) Connectors MMCX. Description. Features/Benefits. Applications

OPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.

High Temperature Flexible Control Cable OLFLEX

Thermocouple & Extension Wire

Amphenol RF. Mini-BNC Mini-BNC Connectors. Mini-BNC. Description. Features/Benefits. Applications

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

LITZ WIRE 1

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

15 years of experience

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Data sheet E-DAT Industry RJ45 field plug insert Cat.6 Class E A

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

protim-r Module

SERV-RITE Wire and Cable

High Temperature Flexible Control Cable

Product Information Motor and machine protection

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Glenair s Series 80 ASAP Cordsets for High-Speed Ethernet, USB and Firewire Applications

Selection table for flat & ribbon cables

SUPERIOR MARINE CABLE SOLUTIONS

Communication, Control, and Industrial Cable

Microwave Coax. w w w. t e m p f l e x. c o m ( ) M i l f o r d R d. S o u t h G r a f t o n, M A

Medium Voltage Power Cables

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

NETWORK CONNECTIVITY SYSTEMS

Airport Cables & Connectors

FLEXFORCE flexible power cables

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

Gain flexibility. Save weight. Specialty cables

III, (12) United States Patent. (10) Patent No.: US B2. Pagliuca et al. (45) Date of Patent: Dec. 8, 2015 (54)

TIMES QUALIFIED MILTECH CABLE ASSEMBLIES

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

Setting Standards Connectors M 16

Microminiature MTB1

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

LSZH _ LSZH CABLES READOUTS, DATALOGGERS & ACCESSORIES

Transcription:

Aeronautic and military ELECTROAIR Aeronautic and military cables High mechanical and temperature performances Thin insulation (compactness) Protection against electromagnetic interferences High temperature: until +200 C (peak at 230 C) High mechanical High chemical Arc Tracking ( for AGF / AGZ / 7080 / 7083 Ranges, 604 & 605) Also a new Innovation of C.G.P CERAFIL Cable with a ceramic insulation Very compact and light, High temperature +500 C

ELECTROAIR ETFE insulation Flexible cable 600Veff, +150 C, ETFE KU 01 (mono) / 03 (twisted pair) / 04 (twisted triple) 600Veff, +150 C, ETFE, shielded KU 02 (mono) / 05 (twisted pair) / 06 (twisted triple) FEP insulation Flexible cable 250/600/1000 Veff, +200 C, FEP 1 to 4 cores (twisted) AGF & AGZ 250/600/1000 Veff, +200 C, FEP, shielded 1 to 4 cores (twisted) AGF BLS & AGZ BLS PTFE tape Flexible cable 250/600/1000 Veff, +250 C, PTFE monoconductor ETRP, ERP, EERP Complex POLYIMIDE / PTFE lightweight cables & compact 600Veff, +150 C/+200 C Mono conductor 6007KD, 7080 600Veff, +150 C, shielded Multi conductor 6010KD, 7083 CERAFIL Ceramic insulation +500 C, Ceramic, very compact & very lightweight wire CERAFIL

KU ELECTRONIC CABLE +150 C ETFE APPLICATION: Automotive and military wiring. : KU 01 : KU 01 : KU 03 : KU 03 : KU 04 : KU 04 ETFE insulation Tinned copper core Core: Tinned copper. Multi-strand, flexible. Insulation: ETFE fluorinated polymer. Designation KU 01: Monoconducteur. KU 03: Plain twisted pair. KU 04: Plain twisted triple. Voltage rating (U0/U): 600 volts effective. Temperature rating: to +150 C ambient + heating, (peak at +180 C). PKG = Disposable drums, spools or reels. UV Abrasion Hydrolysis Radiation proof Water. Resistance to sea water. MIL W 2275918. NF C 93-524. Gauge: AWG 30 AWG 28 AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section: 0,05 mm² 0,09 mm² 0,15 mm² 0,25 mm² 0,38 mm² 0,60 mm² 0,93 mm² 1,34 mm² 1,82 mm² 3,00 mm² Number of strands: 7 x 0,10 7 x 0,13 19 x 0,10 19 x 0,13 19 x 0,16 19 x 0,20 19 x 0,25 19 x 0,30 37 x 0,25 37 x 0,32 Conductor KU 01,30 KU 01,28 KU 01,26 KU 01,24 KU 01,22 KU 01,20 KU 01,18 KU 01,16 KU 01,14 KU 01,12 Diameter (mm) 0,63 0,69 0,81 0,91 1,10 1,52 1,80 2,00 2,36 2,89 Mass (gr/m) 0,9 1,3 1,9 2,9 4,3 7,1 11,0 14,5 20,0 30,5 Pair KU 03,30 KU 03,28 KU 03,26 KU 03,24 KU 03,22 KU 03,20 KU 03,18 KU 03,16 KU 03,14 KU 03,12 Diameter (mm) 1,26 1,38 1,62 1,82 2,20 3,04 3,60 4,00 4,72 5,78 Mass (gr/m) 1,90 2,60 3,85 5,85 8,60 14,50 22,30 29,00 40,50 63,00 Triple KU 04,30 KU 04,28 KU 04,26 KU 04,24 KU 04,22 KU 04,20 KU 04,18 KU 04,16 KU 04,14 KU 04,12 Diameter (mm) 1,35 1,50 1,74 1,96 2,37 3,27 3,87 4,30 5,08 6,20 Mass (gr/m) 2,7 3,9 5,8 8,8 12,9 21,5 33,3 44,0 60,6 92,50 25

KU shielded ELECTRONIC CABLE +150 C ETFE APPLICATION: Automotive and military wiring. : KU 02 : KU 02 : KU 05 : KU 05 : KU 06 : KU 06 ETFE sheath Tinned copper braid ETFE insulation Tinned copper core Designation Core: Tinned copper. Multi-strand, flexible Insulation: ETFE fluorinated polymer. Shielding: Tinned copper braid. Sheath: ETFE fluorinated polymer. KU 02: Monoconductor. KU 05: Shielded twisted pair. KU 06: Shielded twisted triple. Voltage rating (U0/U): 600 volts effective. Temperature rating: to +150 C ambient + heating, (peak at +180 C). PKG. = Disposable spools or reels. UV Abrasion Hydrolysis Radiation proof Water. Resistance to sea water. MIL W 2275918. NF C 93-524. Gauge: AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section: 0,25 mm² 0,38 mm² 0,60 mm² 0,93 mm² 1,34 mm² 1,82 mm² 3,00 mm² Number of strands: 19 x 0,13 19 x 0,16 19 x 0,20 19 x 0,25 19 x 0,30 37 x 0,25 37 x 0,32 Conductor KU 02,24 KU 02,22 KU 02,20 KU 02,18 KU 02,16 KU 02,14 KU 02,12 Outer diam.: 1,71 1,96 2,38 2,76 2,96 3,32 3,85 Mass (g/m): 7,3 9,6 14,2 19,0 24,0 31,5 44,3 Pair KU 05,24 KU 05,22 KU 05,20 KU 05,18 KU 05,16 KU 05,14 KU 05,12 Outer diam.: 2,77 3,15 4,02 4,54 4,94 5,72 6,78 Mass (g/m): 13,5 17,5 26,5 36,5 44,0 59,0 84,0 Triple KU 06,24 KU 06,22 KU 06,20 KU 06,18 KU 06,16 KU 06,14 KU 06,12 Outer diam.: 2,90 3,30 4,22 4,82 5,25 6,10 7,25 Mass (g/m): 17,0 24,0 36,0 50,0 62,0 83,0 121,0 26

AGF AERONAUTIC ELECTRONIC CABLE +200 C FEP APPLICATION: Aeronautic wiring. : AGF : AGF : AGF TWISTED : AGF TWISTED FEP insulation Silver-plated copper core AGF elements Core: Silver-plated copper. Multi-strand, flexible. Insulation: Fluorinated polymer FEP. Twisted: 2. 3 and 4 conductors. Voltage rating (U0/U): 600 volts effective. Temperature rating: to +200 C ambient + heating, (peak at +230 C) PKG = Spools. Mechanical strength UV Abrasion Hydrolysis Arc-tracking FAR 25. AITM2-0008. 503-511 Water. Resistance to sea water. 604 et 605. AECMA. AIR 4524-E. NEMA HP4. Behaviour according to NF C 93-523. Gauge AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section 0,15 mm² 0,24 mm² 0,38 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,91 mm² 2,98 mm² Number of strands 19 x 0,102 19 x 0,127 19 x 0,160 19 x 0,203 19 x 0,254 19 x0,287 19 x 0,361 37 x 0,320 Element 48 014 091 48 024 081 48 038 071 48 060 341 48 093 161 48 113 131 48 120 061 48 130 081 600 Volts AGF 05,04 AGF 05,05 AGF 05,06 AGF 05,07 AGF 05,08 AGF 05,09 AGF 05,10 AGF 05,11 Diameter (mm) 1,00 1,13 1,27 1,47 1,77 2,00 2,44 2,80 Mass (g/m) 2,7 3,7 5,1 7,8 11,9 16,8 21,3 35,9 Gauge AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section 0,15 mm² 0,24 mm² 0,38 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,91 mm² 2,98 mm² 2 conductors 2AGF05,04 2AGF05,05 2AGF05,06 2AGF05,07 2AGF05,08 2AGF05,09 2AGF05,10 2AGF05,11 Diameter (mm) 2,00 2,26 2,54 2,94 3,54 4,00 4,88 5,60 3 conductors 3AGF05,04 3AGF05,05 3AGF05,06 3AGF05,07 3AGF05,08 3AGF05,09 3AGF05,10 3AGF05,11 Diameter (mm) 2,15 2,43 2,73 3,16 3,81 4,30 5,25 6,02 4 conductors 4AGF05,04 4AGF05,05 4AGF05,06 4AGF05,07 4AGF05,08 4AGF05,09 4AGF05,10 4AGF05,11 Diameter (mm) 2,41 2,73 3,07 3,55 4,27 4,83 5,89 6,76 31

AGF - BLS AERONAUTIC ELECTRONIC CABLE +200 C FEP APPLICATION: Aeronautic wiring. : AGF - BLS : AGF - BLS FEP oversheath Silver-plated copper braid AGF elements Core: Silver-plated copper. Multi-strand, flexible. Insulation: Fluorinated polymer FEP. Assembling: 1 conductor, 1 pair, 1 triple. Shielding: Silver-plated copper braid. Outer sheath: Fluorinated polymer FEP. Voltage rating (U0/U): 600 Volts effective. Temperature rating: to +200 C ambient + heating, (peak at +230 C). PKG = Spools. Mechanical strength UV Abrasion Hydrolysis Arc-tracking FAR 25. AITM2-0008. 503-511 Water. Resistance to sea water. AECMA. AIR 4524-E. NEMA HP4. Behaviour according to NF C 93-523. Gauge AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section: 0,15 mm² 0,24 mm² 0,38 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,91 mm² 2,98 mm² 1 conductor AGF05.04BLS AGF05.05BLS AGF05.06BLS AGF05.07BLS AGF05.08BLS AGF05.09BLS AGF05.10BLS AGF05.11BLS Diameter (mm) 2,40 2,45 2,70 3,1 3,4 3,9 4,4 2 conductors 2AGF05.04BLS 2AGF05.05BLS 2AGF05.06BLS 2AGF05.07BLS 2AGF05.08BLS 2AGF05.09BLS 2AGF05.10BLS 2AGF05.11BLS Diameter (mm) 3,0 3,50 3,90 4,40 5,0 5,6 6,5 7,5 3 conductors 3AGF05.04BLS 3AGF05.05BLS 3AGF05.06BLS 3AGF05.07BLS 3AGF05.08BLS 3AGF05.09BLS 3AGF05.10BLS 3AGF05.11BLS Diameter (mm) 3,70 4,10 4,70 5,4 5,9 6,9 8,0 4 conductors 4AGF05.04BLS 4AGF05.05BLS 4AGF05.06BLS 4AGF05.07BLS 4AGF05.08BLS 4AGF05.09BLS 4AGF05.10BLS 4AGF05.11BLS Diameter (mm) 32

AGZ - AGZ BLS AERONAUTIC ELECTRONIC CABLE +200 C FEP APPLICATION: Aeronautic wiring. : AGZ : AGZ : AGZ BLS : AGZ BLS FEP insulation Silver-plated copper core FEP sheath Silver-plated copper braid AGZ elements Stranded core: Silver-plated copper. Multi-strand, flexible. Insulation: Fluorinated polymer FEP. Assembling: 1 conductor, 1 pair, 1 triple. Shielding: Silver-plated copper braid. Outer sheath: Fluorinated polymer FEP. Voltage rating (U0/U): AGZ04 250 V - AGZ05 600 V - AGZ06 1000 V. Temperature rating: to +200 C ambient + heating, (peak at +230 C). PKG = Spools Mechanical strength UV Abrasion Hydrolysis Arc-tracking FAR 25. AITM2-0008. 503-511 Water. Resistance to sea water. 604 et 605. AECMA. AIR 4524-E. NEMA HP4. Behaviour according to NF C 93-523 Gauge AWG 28 AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section 0,09 mm² 0,14 mm² 0,22 mm² 0,34 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,91mm² 3,09mm² Number of strands 7 x 0,127 7 x 0,160 7 x 0,203 7 x 0,254 7 x 0,320 7 x 0,404 19 x 0,287 19 x 0,361 19 x 0,455 250 Volts AGZ 04,03 AGZ 04,04 AGZ 04,05 AGZ 04,06 AGZ 04,07 Diameter (mm) 0,68 0,79 0,91 1,06 1,27 Mass (g/m) 1,5 2,1 3,0 4,6 7,6 600 Volts AGZ 05,03 AGZ 05,04 AGZ 05,05 AGZ 05,06 AGZ 05,07 AGZ 05,08 AGZ 05,09 AGZ 05,10 AGZ 05,11 Diameter (mm) 0,90 1,00 1,13 1,27 1,47 1,77 2,00 2,44 2,90 Mass (g/m) 2,0 2,7 3,7 5,1 7,8 11,9 16,8 21,3 35,9 1000 Volts AGZ 06,03 AGZ 06,04 AGZ 06,05 AGZ 06,06 AGZ 06,07 AGZ 06,08 AGZ 06,09 AGZ 06,10 AGZ 06,11 Diameter (mm) 1,14 1,24 1,37 1,52 1,74 2,02 2,25 2,70 3,20 Mass (g/m) 2,8 3,5 4,5 6,2 9,0 12,8 16,9 25,0 39,0 Gauge: 600 Volts AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Section: 0,14mm² 0,22 mm² 0,34mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,91mm² 3,09mm² 1 conductor AGZ 57,04 AGZ 57,05 AGZ 57,06 AGZ 57,07 AGZ 57,08 AGZ 57,09 AGZ 57,10 AGZ 57,11 Diameter (mm) 2 2,2 2,4 2,7 3,1 3,4 3,9 4,4 2 conductors AGZ 69,04 AGZ 69,05 AGZ 69,06 AGZ 69,07 AGZ 69,08 AGZ 69,09 AGZ 69,10 AGZ 69,11 Diameter (mm) 3,0 3,4 3,7 4,4 5,0 5,6 6,5 7,5 3 conductors AGZ 81,04 AGZ 81,05 AGZ 81,06 AGZ 81,07 AGZ 81,08 AGZ 81,09 AGZ 81,10 AGZ 81,11 Diameter (mm) 3,3 3,6 4,0 4,7 5,4 5,9 6,9 8,0 33

ETRP - ERP - EERP AERONAUTIC ELECTRONIC CABLE Silver-plated copper core -90 C +200 C Nickel-plated copper core -90 C +250 C PTFE APPLICATION: Aeronautic wiring. : XX RP : XX RP Welded PTFE tape insulation Silver-plated or nickel-plated copper core Core: Silver-plated copper. Multi-strand, flexible. Insulation: Welded PTFE tape. Options Nickel-plated copper. Multi-strand, flexible Voltage rating (U0/U): Series ET: 250 V - series E: 600 V - series EE: 1000 V. Temperature rating: Silver-plated copper core: -90 C to +200 C (ambient + heating). Nickel-plated copper core: -90 C to +250 C (ambient + heating). PKG = Spools. Hydrolysis Water. Resistance to sea water. NF C 93-523. AIR 4524-E. NEMA HP3. MILW 16878D. US Gauge: AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 Cross section: 0,14 mm² 0,15mm² 0,22 mm² 0,21 mm² 0,34 mm² 0,38 mm² 0,6 mm² 0,93 mm² 1,34 mm² Number of strands: 7 x 0,16 19 x 0,10 7 x 0,20 19 x 0,12 7 x 0,25 19 x 0,16 19 x 0,20 19 x 0,25 19 x 0,30 250 Volts ET RP7,016 ET RP19,010 ET RP7,020 ET RP19,012 ET RP7,025 ET RP19,016 ET RP19,020 Diameter (mm) 0,79 0,80 0,91 0,96 1,06 1,11 1,35 Mass (g/m) 2,1 2,1 3,0 3,0 4,6 4,6 7,6 600 Volts E RP7,016 E RP19,010 E RP7,020 E RP19,012 E RP7,025 E RP19,016 E RP19,020 E RP19,025 E RP19,030 Diameter (mm) 1,05 1,0 1,17 1,15 1,22 1,27 1,55 1,75 2,0 Mass (g/m) 2,7 2,9 4,1 4,1 5,5 5,5 7,9 11,4 15,5 1000 Volts EE RP7,016 EE RP19,010 EE RP7,020 EE RP19,012 EE RP7,025 EE RP19,016 EE RP19,020 EE RP19,025 EE RP19,030 Diameter (mm) 1,25 1,25 1,37 1,37 1,53 1,53 1,73 2,00 2,25 Mass (g/m) 3,4 3,4 4,5 4,6 6,0 6,2 9,0 12,8 17,6 34

6007 KD AERONAUTIC CABLE +200 C POLYIMIDE APPLICATION: Wiring. : 6007 KD : 6007 KD Coloured PTFE coating Polyimide tapes Silver plated copper core Core: Silver-plated copper. Multi-strand, flexible. Insulation: Polyimide tapes. Coating: PTFE. Voltage rating (U0/U): 600 volts effective. Temperature rating: to +200 C ambient + heating, (peak at +230 C). PKG = Spools. Mechanical strength Radiation proof AECMA. AIR 4524-E. MIL W81581. US Gauge: AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 AWG 10 Cross section: 0,15 mm² 0,21 mm² 0,34 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,82 mm² 2,98 mm² 4,91mm 2 Number of strands: 19 x 0,10 19 x 0,12 19 x 0,15 19 x 0,20 19 x 0,25 19 x 0,30 37 x 0,25 37 x 0,32 61 x 0,32 Outer diam.: 0,80 0,90 1,06 1,32 1,57 1,84 2,11 2,65 3,30 Mass (Kg/Km): 1,85 2,52 3,74 6,33 9,50 13,40 18,10 29,00 47,52 27

7080 AERONAUTIC CABLE -90 C +150 C POLYIMIDE/PTFE/FEP APPLICATION: Aeronautic wiring, in-flight test. : 7080 : 7080 PTFE tapes Polyimide tapes Tinned copper Core: Tinned copper. Multi-strand, flexible. Insulation: Polyimide tape. Covering: Taped PTFE. Options Silver-plated copper: temperature 200 C. Nickel-plated copper: temperature 250 C. Coating light alloy: temperature 250 C. Voltage rating (U0/U): 600 volts effective. Temperature rating: -90 C to +150 C (peak at +180 C). PKG = Spools. Low toxicity Arc-tracking Abrasion FAR 25. AITM3-0005. AITM2-0008. 604 et 605. 503 and 511. NF EN 2267 US Gauge: AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 Cross section: 0,25 mm 2 0,34 mm 2 0,6 mm 2 0,93 mm 2 1,34 mm 2 Number of strands: 19 x0,12 19 x 0,16 19 x 0,20 19 x 0,25 19 x 0,30 Diameter (mm): 1,00 1,05 1,28 1,53 1,54 Resistance per unit length (Ω/Km) 114,00 60,00 33,20 21,10 14,5 Mass (Kg/Km): 3,10 4,14 6,85 10,43 14,61 29

6010 KD AERONAUTIC CABLE +150 C POLYIMIDE APPLICATION: Cable bundles. : 6010 KD : 6010 KD Fluorinated coating Polyimide tape Tinned copper Silver-plated copper Elements: 6007 KD series wires identified by dark green rings. Assembling: 1 wire, 1 pair, 1 triple or 1 quad. Shielding: Helical by covering with tinned copper threads. Outer sheath: Welded polyimide tape with fluorinated coating. Options Silver-plated copper covering, temperature: 200 C. Voltage rating (U0/U): 600 volts effective. Temperature rating: to +150 C ambient + heating, (peak at +180 C). PKG = Spools. Mechanical strength Radiation proof AECMA. AIR 4524-E. US Gauge: AWG 26 AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 AWG 14 AWG 12 Cross section: 0,15 mm² 0,21 mm² 0,34 mm² 0,6 mm² 0,93 mm² 1,34 mm² 1,82 mm² 2,98 mm² Diameter / Mass (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) 1 conductor 1,06 3,85 1,16 4,72 1,30 6,25 1,60 9,58 1,84 13,80 2,12 18,35 2,43 23,85 2,97 39,20 2 conductors 1,84 6,80 2,10 9,09 2,41 12,20 2,96 19,46 3,50 28,92 4,00 38,26 4,64 49,40 5,75 82,10 3 conductors 2,00 9,72 2,25 12,30 2,57 16,75 3,18 27,00 3,74 40,18 4,27 53,70 5,05 74,74 6,21 124,5 4 conductors 2,25 12,70 2,46 15,53 2,82 22,61 3,45 36,70 4,11 52,36 4,79 75,58 5,57 102,2 6,96 173,8 28

CÂBLES HAUTE TEMPÉRATURE 7083 Série 7080 blindés CÂBLE AERONAUTIQUE +150 C POLYIMIDE/PTFE/FEP UTILISATION TYPE : Fil de câblage aéronautique, essai en vol. : 7083 : 7083 Gaine fluorée FEP Guipage cuivre étamé Rubans PTFE Rubans Polyimide Cuivre étamé Ame : Cuivre étamé. Souple multibrins. Isolant : Ruban polyimide + ruban PTFE. Assemblage : 1 fil, 1 paire, 1 tierce ou 1 quarte. Blindage : Hélicoïdal par guipage de fils cuivre étamé (Kr90%). Gaine extérieure : Polymère fluoré FEP. Options Cuivre argenté : température 200 C : version gaine polyimide + PTFE. Cuivre nickelé : température 250 C : version gaine polyimide + PTFE. Alliage léger revêtu : température 250 C : version gaine extérieure polyimide + PTFE. Tension assignée (U0/U) : 600 volts efficaces. Plage de température de -90 C à +150 C (pointe à +180 C). Cdt.= Bobines Comportement au feu Faible toxicité des fumées Faible densité de fumées Tenue chimique Arc-tracking Résistance à l'abrasion Tenue au vide Homologations et Normes C2 selon FAR 25. AITM3-0005. AITM2-0008. Résistant aux huiles. Résistant aux hydrocarbures. Résistant aux agents chimiques. Résistant aux agents biologiques. 604 et 605. 503 et 511. Pas de dégazage. NF EN 2267 Gauge AWG 24 AWG 22 AWG 20 AWG 18 AWG 16 Section 0,21 mm 2 0,34 mm 2 0,6 mm 2 0,93 mm 2 1,34 mm 2 Diamètre / Masse (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) (mm) (Kg/Km) 1 conducteur 1,50 6,50 1,70 8,80 2 conducteurs 2,5 13,20 2,80 16,80 3,30 24,40 3,80 34,30 3 conducteurs 2,70 16,70 3,00 22,30 4 conducteurs 2,90 21,00 3,30 28,80 * Autres sections et variantes : Nous consulter Reproduction interdite sans l'accord de PLASTELEC. Informations indicatives et non contractuelles susceptibles de modifications sans préavis. 30

CERAFIL 500-90 C +500 C CERAMIC APPLICATION: Special windings of motors or sensors continuously operating in VLV under high temperatures, up to +500 C (with peaks of +1000 C). : CERAFIL 500 : CERAFIL 500 Ceramic insulation Coated alloy Core: Coated alloy. Single strand rigid. Insulation: Ceramic deposited in a thin coating. Options Metal alloy: Type: - Thermocouple - Resistant - Others after study. Voltage rating (U0/U): 100 / 170 V - Test voltage: 170 V Temperature rating: -90 C to +500 C (peak at +1000 C.) PKG = Spools C1 according to NF C 32-070 NF C 32-070 IEC 60332-1 Halogen-free Low corrosivity Low toxicity UV Model US Gauge Outer diameter Weight / 1000 m Metres / 1 Kg 10/100 AWG 38 0,116 mm 71 g 14000 15/100 AWG 34 0,167 mm 161 g 6210 20/100 AWG 32 0,217 mm 286 g 3500 25/100 AWG 30 0,268 mm 446 g 2240 30/100 AWG 28 0,318 mm 637 g 1570 35/100 AWG 27 0,368 mm 862 g 1160 40/100 AWG 26 0,418 mm 1136 g 880 45/100 AWG 25 0,468 mm 1433 g 698 50/100 AWG 24 0,518 mm 1754 g 570 55/100 AWG 23 0,568 mm 2105 g 475 60/100 AWG 22 0,619 mm 2500 g 400 65/100 AWG 22 0,669 mm 2899 g 345 70/100 AWG 21 0,719 mm 3356 g 298 75/100 AWG 20 0,769 mm 3846 g 260 80/100 AWG 20 0,820 mm 4348 g 230 90/100 AWG 19 0,920 mm 5814 g 172 100/100 AWG 18 1,020 mm 7194 g 139 - Resistivity of the conductor core: < 3 µω.cm -2 per cm. - To be protected against humidity. 68