VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

Similar documents
Brake resistor can be connected. 150%/1Hz high starting torque by General -purpose magnetic flux vector control. Safety stop function

A700 Series. Variable Frequency Drives UNSURPASSED POWER AND CONTROL 1 /2-700 HP

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

INVERTER FR-D700. Global standard FACTORY AUTOMATION. Pursuing the easy operation. Long life and simple maintenance. Compact and space-saving

A700 Series. Variable Frequency Drives

VF-nC1 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

TOSVERT TM VF-nC3 Parameter List

E3 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

FUJI Inverter. Standard Specifications

Fan and Pump AC Inverter

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ADJUSTABLE SPEED DRIVES. AS1 Drive

All-rounder with a compact body (Addition of Ethernet communication function models) Easy operability. Extensive option lineup. Ensured maintenance

General Specifications FECA-TE /2010. Phone: Fax: Web:

Manual Overview...1 2

6.9 Jump frequency - Avoiding frequency resonance

INVERTER FREQROL-CS80

Multi-function, Compact Inverters. 3G3MV Series

AF91 Adjustable Frequency Drives Series B

GS1 Parameter Summary Detailed Parameter Listings...4 9

INVERTER. Model FR-E700. All-rounder. Compact body. Easy for anybody and high performance

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

INVERTER FR-A800 Plus

CHAPTER 8 PARAMETER SUMMARY

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Highest level in your hand

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

VFS11 Parameter List for up to CPU version 105

ADVANCED AND EVER ADVANCING FR-V200. FR-V200 series

ADJUSTABLE SPEED DRIVES FS1

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Specifications of ASDA A2-E_220V Series

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

13. Before making a service call Trip information and remedies

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

[ 4 ] Using pulse train input (F01 = 12)

SX (400V) System configuration

SX (400 V) System configuration

WJ200 series Pursuing the Ideal Compact Inverter

VFS9 Parameter List for Version110 or later

High-performance Vector-type SF-G Series Inverter

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

SX (690 V) System configuration

VS-616PC5/P5 Series User s Manual

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

9. RS485 Communication

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Inverter Drive /Vector Drive Motors & Controls

Superior performance just for you

ACH550 HVAC Drive Submittal

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

Design Specifications Operator Keypad Environmental and Operating Conditions

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available.

High Performance Vector control SE2 Series Inverter

The new Yaskawa Varispeed G7 Inverter

9. RS485 Communication (Option)

MITSUBISHI ELECTRIC INVERTER FR-D700 INSTALLATION GUIDELINE FR-D720S-008 to 100-EC FR-D to 160-EC

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

INVERTER FR-D700 INSTALLATION GUIDELINE FR-D to 160-EC FR-D720S-008 to 100-EC

BACnet- MS/TP COMMUNICATION V

Operating Instructions

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

INVERTER. Model FR-F800. Enhanced Next-Generation Energy-Saving Inverter F800 F800

MR-J3 Servomotors and Amplifiers

HPVFP High Performance Full Function Vector Frequency Inverter

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

CTi Automation - Phone: Fax: Web: -

HV580L Series Frequency Inverter User Manual

Micro and Mini Inverters

NX series Constant and variable torque Variable Speed Drives for induction motors

SJ series P1 High performance inverter with innovative ease-of-use and excellent driving performance

CC-Link Compatible AC Servo Amplifier <MR-J3-T type> with Built-in Positioning Function

General Purpose Drives

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

vacon nx all in one application manual ac drives Phone: Fax: Web: -

FR-F K to 55K FR-F K to 55K(-EC) FR-F520-11K to 55K-NA FR-F540-11K to 55K-NA

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

HV580 Series Frequency Inverter User Manual

NX Series Inverters. HVAC Pocket Programming Guide

α α Retry count clear Alarm reset Active End of retry S-curve time during accelerati on H04: (Count) setting S curve time during decelerati on

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Transcription:

VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload protection for 130 seconds, 150% overload protection for 60 seconds, 200% overload protection for 3 seconds, Available in single-phase 115V supply power up to 1HP Available in single-phase 240V supply power up to 3HP Available in three-phase 240V and 480V supply power up to 10HP Internal power supply: 24VDC up to 100mA General-purpose Magnetic Flux Vector Control for improved starting torque and smooth low speed motor operation frequency range of 0.2 to 400Hz Standard RS485 serial communications supporting Modbus RTU Password protected for Read & Write Supports remote I/O function via network Delivers rated current at 50 C and 14.5kHz carrier frequency with minimal de-rating 0 to 10V analog output Standard 5-year warranty D700 Selection & Dimensions Amps HP Model Number Dimensions in inches (mm) Height Width Depth Weight Lbs (kg) Stock 1-Phase 100~120VAC / 3-Phase 200-230VAC 0.8 1/8 FR-D710W-008-NA 5.0 (128) 2.7 (68) 3.2 (81) 1.1 (0.5) S 1.4 1/4 FR-D710W-014-NA 5.0 (128) 2.7 (68) 4.4 (113) 1.3 (0.6) S 2.5 1/2 FR-D710W-025-NA 5.0 (128) 2.7 (68) 5.6 (143) 2.0 (0.9) S 4.2 1 FR-D710W-042-NA 5.0 (128) 6.7 (170) 5.9 (150) 3.8 (1.7) S

Amps HP Model Number Dimensions in inches (mm) Height Width Depth Weight Lbs (kg) Stock 1-Phase 200~240VAC / 3-Phase 200-230VAC 0.8 1/8 FR-D720S-008-NA 5.0 (128) 2.7 (68) 3.2 (81) 1.1 (0.5) S 1.4 1/4 FR-D720S-014-NA 5.0 (128) 2.7 (68) 3.2 (81) 1.3 (0.6) S 2.5 1/2 FR-D720S-025-NA 5.0 (128) 2.7 (68) 5.6 (143) 2.0 (0.9) S 4.2 1 FR-D720S-042-NA 5.0 (128) 2.7 (68) 6.5 (163) 2.5 (1.1) S 7.0 2 FR-D720S-070-NA 5.0 (128) 4.3 (108) 6.2 (156) 3.3 (1.5) S 10 3 FR-D720S-100-NA 5.9 (150) 5.5 (140) 5.7 (145) 4.2 (1.9) S 3-Phase 200~240VAC & 0.8 1/8 FR-D720-008-NA 5.0 (128) 2.7 (68) 3.2 (81) 1.1 (0.5) S 1.4 1/4 FR-D720-014-NA 5.0 (128) 2.7 (68) 3.2 (81) 1.1 (0.5) S 2.5 1/2 FR-D720-025-NA 5.0 (128) 2.7 (68) 4.4 (113) 1.8 (0.8) S 4.2 1 FR-D720-042-NA 5.0 (128) 2.7 (68) 5.2 (133) 2.2 (1.0) S 7.0 2 FR-D720-070-NA 5.0 (128) 4.3 (108) 5.3 (136) 3.1 (1.4) S 10 3 FR-D720-100-NA 5.0 (128) 4.3 (108) 5.3 (136) 3.1 (1.4) S 16.5 5 FR-D720-165-NA 5.0 (128) 6.7 (170) 5.6 (143) 3.8 (1.7) S 23.8 7 1/2 FR-D720-238-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.5 (3.4) S 31.8 10 FR-D720-318-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.5 (3.4) S 3-Phase 380~480VAC & 1.2 1/2 FR-D740-012-NA 5.0 (128) 4.3 (108) 5.1 (130) 2.7 (1.2) S 2.2 1 FR-D740-022-NA 5.0 (128) 4.3 (108) 5.1 (130) 2.7 (1.2) S 3.6 2 FR-D740-036-NA 5.0 (128) 4.3 (108) 5.4 (136) 2.9 (1.3) S 5 3 FR-D740-050-NA 5.0 (128) 4.3 (108) 6.2 (156) 3.1 (1.4) S 8 5 FR-D740-080-NA 5.0 (128) 4.3 (108) 6.6 (166) 3.3 (1.5) S 12 7 1/2 FR-D740-120-NA 5.9 (150) 8.7 (220) 6.1 (155) 6.9 (3.1) S 16 10 FR-D740-160-NA 5.9 (150) 8.7 (220) 6.1 (155) 6.9 (3.1) S

D700 Series General Specifications Control Method Frequency Range Soft-PWM control/high carrier frequency PWM control (V/F control, general-purpose magnetic flux vector control, optimum excitation control can be selected) 0.2 to 400Hz Frequency Setting Resolution Analog Digital 0.06Hz/60Hz (terminal2, 4: 0 to 10V/10bit) 0.12Hz/60Hz (terminal2, 4: 0 to 5V/9bit) 0.06Hz/60Hz (terminal4: 4 to 20mA/10bit) 0.01Hz Control Specifications Frequency Accuracy Voltage/Frequency Characteristics Starting Torque Analog Digital Within ±1% of the max. output frequency (25 C ±10 C) Within 0.01% of the set output frequency Base frequency can be set from 0 to 400Hz Constant torque/variable torque pattern can be selected 150% or more (at 1Hz) when general-purpose magnetic flux vector control and slip compensation is set Torque Boost Acceleration/Deceleration Time Setting DC Injection Brake Stall Prevention Operation Level Manual torque boost 0.1 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected. Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected Operation Specifications Frequency Setting Signal Start Signal Signal Analog Digital Two points Terminal 2: 0 to 10V, 0 to 5V can be selected Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected Entered from operation panel and parameter unit. Frequency setting increments is selectable Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. Five points You can select from among multi-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PUexternal operation switchover, V/F switchover, output stop, start

self-holding selection, traverse function selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, external-net operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock Operational Functions Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link operation (RS-485), optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU Signal Points Open Collector Relay One point One point Signal Operating Status For Meter Points Pulse You can select from among inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function pre-alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, brake opening request, fan alarm*2, heatsink overheat prealarm, deceleration at an instantaneous power failure, PID control activated, PID output interruption, during retry, life alarm, current average value monitor, remote output, alarm output, fault output, fault output 3, and maintenance timer alarm MAX 2.4kHz: one point For Meter You can select from among output frequency, motor current (steady), output voltage, frequency setting, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set point, PID measured value, output power, PID deviation, motor thermal load factor, inverter thermal load factor, pulse train output (1440 pulses/full scale) Indication Operation Panel Parameter Unit (FR- PU07) Operating Status You can select from among output frequency, motor current (steady), output voltage, frequency setting, cumulative energization time, actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, output power, cumulative power, motor thermal load factor, and inverter thermal load factor, PTC thermistor resistance

Additional Display By The Parameter Unit (FR- PU04/FR- PU07) Only Fault Definition Operating Status Fault Definition Interactive Guidance Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative energization time right before the fault occurs) are stored Not used voltage/current/frequency/cumulative energization time immediately before the fault occurs Function (help) for operation guide Protective & Warning Function Ambient Temperature Protective functions Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat, input phase failure (*4 *5), output side earth (ground) fault overcurrent at start (*4), output phase failure, external thermal relay operation (*4), PTC thermistor operation (*4), parameter error, PU disconnection, retry count excess (*4), CPU fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value exceeded Warning functions Fan alarm (*2), overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake prealarm (*4), electronic thermal relay function pre-alarm, maintenance output (*4), undervoltage, operation panel lock, password locked, inverter reset -10 C to +50 C (14 F to 122 F) (non-freezing), -10 C to +40 C (14 F to 104 F) for totally-enclosed structure feature (*3) Environment Ambient Humidity Storage Temperature (*1) Atmosphere 90%RH maximum (non-condensing) -20 C to +65 C (-4 F to 149 F) Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.) Altitude/Vibration Maximum 1000m (3280.80 feet) above sea level, 5.9m/s 2 or less Notes: *1. Temperatures applicable for a short time, e.g. in transit. *2. As the 0.75K or less is not provided with the cooling fan, this alarm does not function. *3. When using the inverters at the ambient temperature of 40 C (104 F) or less, the inverters can be installed closely attached (0cm clearance). *4. This protective function does not function in the initial status. *5. This protective function is available with the three-phase power input specification model only.

Terminal Connection Diagram Three Phase 200V power input Three Phase 400V power input Single Phase 115V power input Single Phase 200V power input