SCHEDULE OF WORK. Balmer Lawrie Co. Ltd. PRICED BID (PART-II) MMLH

Similar documents
TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

CHAPTER-E-21. T1 Column With Beam Arrangement in Substation. T2 Column With Beam Arrangement in Substation

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

KENYA ELECTRICITY GENERATING COMPANY LTD

Form-IV. Form of Inspection/Test Report. (Under Regulation 43)

NATIONAL INSTITUTE OF NUTRITION, HYDERABAD (UPGRADATION OF EXTERNAL ELECTRICAL WORKS)

Substation Preventive Maintenance

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

E S T I M A T E Name of Work : Estimate of Electric & Air Conditioned Work for Union Bank of India, Saral Branch, Dist. Rajkot.

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

GENERAL TECHNICAL SPECIFICATION

Report on investigation of failure of 315 MVA Auto transformer at 400 kv Bawana Substation of Delhi Transco Ltd.(DTL)

kv AC substation

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

POWER SERVICE DETAILS

Welcome to the Session on. HT Distribution Network

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

UNITED INDIA INSURANCE CO. LTD

Distribution/Substation Transformer

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

TECHNICAL SPECIFICATION

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

50-SDMS-01 SPECIFICATIONS FOR

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

VOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)

SECTION : 8.0. Guaranteed Technical Particulars

MECON LIMITED RANCHI INDIA

TECHNICAL SPECIFICATIONS FOR BOLT HEATING EQUIPMENT

Earth Fault Indicator EFI-BLZ-50 User Manual

POTENTIAL TRANSFORMER

VI 3 - i TABLE OF CONTENTS

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Our Ref: SRO/BM/C Date:

Technical Specifications SECTION C

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

LIGHTNING ARRESTOR. September 2017 WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED

Table of Contents. Introduction... 1

Wisconsin Contractors Institute Continuing Education

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

General Electricity Company of Libya

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Article 250 Grounding & Bonding

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

STANDARD TECHNICAL SPECIFICATION FOR UNDERGROUND CABLE FAULT LOCATING EQUIPMENT AND OTHER ACCESSORIES

Technical Specifications

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

Wire Mesh Cable Tray System for Channeling of Cable Wiring

Hi5 s Expert Guide to Specify afix Lecture Hall Tables

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

American Electrical Institute

SECTION CABLE TRAYS

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

N. TEST TEST DESCRIPTION

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

CONTROL & RELAY PANEL

General Requirements. Technical Specification LVAC Systems

DISTRIBUTION TRANSFORMER kv

ARCMASTER. 401MST Multi-Process Inverter Power Source Part No. W

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

GAIL (India) Limited (A Govt. of India Undertaking) A Navratna Company New Delhi (India)

N. TEST TEST DESCRIPTION

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

SINGLE-PHASE VSV SWITCH

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Wire Mesh Cable Tray System for Channeling of Cable Wiring

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR , INDIA

Underground System Design TADP 547

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

NIPPEN ELECTRICAL INSTRUMENTS CO.

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Distance Protection for Distribution Feeders. Presented By: Yordan Kyosev, P.Eng. & Curtis Ruff, P.Eng.

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Impact Assessment Generator Form

SLD FOR 132/33 KV DUB STATION, SOMANATHPUR

Transcription:

SCHEDULE OF WORK Supply, Installation, Testing & Commissioning (SITC) of 33KV Electrical Substation for Multi Modal Logistics Hub at Visakhapatnam, Andhra Pradesh. Tender No. MMLH /HTELEC/PT /18 dated 24/01/2017; Due on 14/02/2017 Electrical Supply & Installation Work for 33 KV Electrical System from Metering up to 2 x 1500 KVA Transformer Sub-Station 1.0 SITC of 30 KV 10 KA LA R Y B with mounting 2.0 SITC of 33 KV, 1250 AMP AB switch with earth switch with structure complete Nos. 1 3.0 SITC of 33 KV metering cubicle complete with CT,PT, ABT ( Main, Check, Stand by )as per AP electricity board norms & requirement. (OPTIONAL, will be executed as per the direction of APEPDCL) CST/ CST/ Total Service Tax Total 4.0 33 KV, 1250 AMP, 26.3 KA, RMU Kiosk Outdoor Unit as per AP Electricity Board Norms & SLD.(Refer Technical Specification of HT Breaker (VCB)) INCOMER - Volt Meter, Amp, Load Manager, Protection O/C, E/F, High Set, Relay MJT 315 or EQV, o/u voltage, Master Trip, Trip CKT Super Vision, Annunciator 8 Window, Aux 230 V Ac & 110 VDC for Trip, Close & Indication, Power Pack With 230/110 V AC I/P & 110 VDC O/P ) Other as per IS Standard & Panel should be extendable. 5.0 Clamp, Connector, Conductor & required Hardware as per AP Electricity Board 6.0 SITC of 3CX240 SQMM, 33 KV (UE) AL. Round Arm XLPE cable underground line at 1200 mm depth with all required material RCC slab, trench, sand, cable route marker / On H.D. GI tray 300x100x2.5 mm, hanger steel support at every 1.25 m, 50x6 mm H.D. GI strip, ms plate, anchor fastener, 2 coat painting all compete as per AP electricity norms & CEI approval. (Refer Technical Specification of HT Cable ) Mtr. 2000 Tender No. MMLH /HTELEC/PT /18 Sign and Stamp of the Bidder 1 of 5

CST/ CST/ Total Service Tax Total 7.0 3CX240 SQMM, 33 KV (UE) AL. Round Arm. XLPE cable underground line at 1200 mm depth with all required material RCC slab, trench, sand, cable route marker as per AP electricity norms & CEI approval- For Road Crossing with Supply and Laying of RCC Hume Pipe. 8.0 33 KV (UE) 3CX240 SQMM cable end termination outdoor 9.0 33 KV (UE) 3CX240 SQMM cable end termination 10.0 33 KV (UE) 3CX240 SQMM cable straight joint Mtr. 40 Set 6 Set 8 Set 2 11.0 33 KV, 1250 AMP, 26.3 KA, VCB panel with 1 Incomer + 2 TR Outgoing +1 O/G feeder as per SLD, & below details.(refer Technical Specification of HT Breaker (VCB)) INCOMER - PT, CT, Volt Meter, AMP, Load Manager, Protection O/C, E/F, High Set, Relay MJT 315 or EQV,O/U Voltage, Master Trip, Trip CKT Super Vision, Annunciator 8 Window, Aux 230 VAC & 110 VDC for Trip, Close & Indication, Power Pack with 230/110 V AC I/P & 110 VDC O/P ) other as per IS standard & panel should be extendable. CTR - 50-100/1-1 A TR OUT GOING FEEDER - CT, Amp Meter, Load Manager, Protection O/C, E/F, High Set, Relay MJT 315 or EQV, Relay Master Trip, Relay (WTI, OTI, BUCHOLZ, OSR, PRV Alarm & Trip ),Trip CKT Super Vision, Annunciator 8 Window, Aux 230 V AC & 110 VDC for Trip, Close & Indication, Power Pack with 230/110 V AC I/P & 110 VDC O/P ) other as per IS standard & panel should be extendable. CTR- 50-100/1-1 A OUT GOING FEEDER -CT, Amp Meter, Load Manager, Protection O/C, E/F, High Set, Relay MJT 315 or EQV, Relay Master Trip, Trip CKT Super Vision, Annunciator 8 Window, AUX 230 V AC & 110 VDC for Trip, Close & Indication, power pack with 230/110 V AC I/P & 110 VDC O/P ) other as per IS standard & panel should be extendable. CTR-50-100/1-1A Tender No. MMLH /HTELEC/PT /18 Sign and Stamp of the Bidder 2 of 5

12.0 33 KV, 1250 AMP, 26.3 KA, VCB Panel with 1 Incomer cum TR Outgoing Feeder. (Refer Technical Specification of HT Breaker (VCB)) ICOG - ICOG - PT, CT, Volt Meter, Amp Meter, Load Manager, Protection O/C, E/F, High Set, Relay MJT 315 or EQV, O/U Voltage, Master Trip, Relay (WTI, OTI, BUCHOLZ, OSR, PRV Alarm & Trip ),Trip CKT Super Vision, Annunciator 8 Window, Aux 230 V AC & 110 VDC For Trip, Close & Indication, Power Pack With 230/110 V Ac I/P & 110 VDC O/P ) Other as per IS Standard & panel should be extendable CTR-50-100/1-1 A. CST/ CST/ Total Service Tax Total 13.0 1500 KVA, 33/0.433 KV, 3 Phase, 50 Hz Transformer with OLTC & RTCC panel Tapping + 10% to -10% in step of 1.255, connection Dyn11, out door, ONAN, HV.( Refer Technical Specification of Power Transformer). Nos. 2 14.0 Battery Charges 40 AH boost cum float mode sub-station type with Battery & Stand Input 3 phase, 50 hz, out put 110 VDC & DC DB WITH 6 Nos 16 Amp O/G Feeder 15.0 Control Cable with required saddling & termination kit 15.1 19CX2.5 SQMM Copper Arm 1.1 KV XLPE Cable 15.2 12CX2.5 SQMM Copper Arm 1.1 KV XLPE Cable 15.3 4CX2.5 SQMM Copper Arm 1.1 KV XLPE Cable 15.4 3CX 6 SQMM SQMM Copper Arm 1.1 KV XLPE Cable 16.0 Earthing Pit GI (Plate / Pipe) as per IS Norms 17.0 Copper earthing pit as per IS norms 18.0 SITC of Hot Dip GI Strip 50x6 MM in 600 MM Depth for Grid 19.0 SITC of Hot Dip GI Strip 50X6 MM for equipment Mtr. 75 Mtr. 150 Mtr. 700 Mtr. 600 Nos 30 Nos 4 Mtr. 300 Mtr. 300 Tender No. MMLH /HTELEC/PT /18 Sign and Stamp of the Bidder 3 of 5

CST/ CST/ Total Service Tax Total 20.0 SITC of hot dip copper strip 50x6 MM in 600 MM depth transformer neutral Mtr. 50 21.0 SITC of Chain Link Fencing including all frame & supports as per 33 KV sub-station standard with 3 location X 2 ( 6 Nos ) pipe Gate as per standard norms. Mtr. 120 22.0 Switch Yard Gravels, Name Plate, Danger Board 22.1 Metering Switch Yard 22.2 Transformer-1 Switch Yard 22.3 Transformer-2 Switch Yard 23.0 AC DB & switch yard lighting & control supply arrangement for all three locations. Lot 3 24.0 Safety accessories with First aid Box for Three Locations Lot 3 25.0 Steel Support, Tray, Trench, Rubber Mat for all Three Locations Metering, Transformer-1 & Transformer-2 Lot 3 [G] Sub Total (Sum of Sl. No no 1.0 upto 25.0) Indicate Total for column [A], [B], [C],[D], [E] & [F]. DESCRIPTION UNIT QTY Service Tax Total with ST 26.0 Third Party Inspection Charges (TPIA) for 26.1 2 nos 1500 KVA Transformers as detailed in item 13 26.2 HT Panel as detailed in item 4.0 26.3 HT Panel as detailed in item 11.0 26.4 HT Panel as detailed in item 12.0 Not to be quoted here [H] Sub Total for TPIA Tender No. MMLH /HTELEC/PT /18 Sign and Stamp of the Bidder 4 of 5

CST/ CST/ Total Service Tax Total [I] GRAND TOTAL (++TPIA Charges) Note: 1) Please fill up, sign, stamp, scan and upload the above mentioned Price Bid. (In Figures) (in Words) 2) 3) Basic for Supply shall include all taxes and duties (except /CST), Packing & forwarding, Loading, transportation & Unloading and Transit Insurance. /CST (at full rate) shall be quoted separately as per above schedule. The Bidder shall pass on the EXCISE/MODAT benefit to the owner/vplpl. 4) Payment will be made based on actual executed quantity only. Name of the Bidder : Signature : Seal of the Company : Date : Place : Tender No. MMLH /HTELEC/PT /18 Sign and Stamp of the Bidder 5 of 5