HOLLY HUNT LIGHTING. STUDIO H EDGE CHANDELIER Installation Instructions

Similar documents
BLUEMOTION UXP, CDP, SD

Instruction page index: Installation Instructions for Kilo S Models KILOS-CF & KILOS-SF. Page 1 of 5. Center Feed installation Side Feed installation

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

!When using electrical equipment, basic safety precautions should always be followed, including the following: AIR FOIL CLUSTER CP5371

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

Connect each sections electricity cables with a connections block or splices and heatshrink. Proceed to Myla installation manual.

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

A524 ASSEMBLY & INSTALLATION INSTRUCTIONS BELLADONNA PENDANT CASTLETON, VERMONT USA SYNCHRONICITYLIGHTING.COM Rev A 1 OF 7

Connecting the Channel A

Installation Instructions for DIY or Completed Light Channel.6 Millwork

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

INSTALLATION INSTRUCTIONS

General Installation Instructions

The Mind Project s Iris 1 Robotic Arm. Packing List Assembly instructions

The Mind Project s Iris 1 Robotic Arm. Assembly instructions Step 1

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Installation Instructions for DIY or Completed 45 Degree Light Channel

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

A500 ASSEMBLY & INSTALLATION INSTRUCTIONS

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

CNC Router Parts PRO Machine Kit Cable Track Installation Instructions

**MOUNTING YOUR MONITOR

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

H2-50 Hydrogen Generator Field Update

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

Elements Pole Mounting System

INSTALLATION INSTRUCTIONS FOR HAND OPERATED MODELS: 170, 171-R, 171-N, 172, 260

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

PORTA-DOCK, INC. AP17 APD DS 4 X 16 T12 AW17 CPD DS 4 X 16 T12

Thank you for purchasing out product! *Please read these instructions and follow them step by step. *

UR20/UR28 Ouro Site/Area Luminaire Installation Instructions

User Instructions Multiline Otter Scoreboard Caddy Assembly

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

INSTALLATION INSTRUCTIONS FOR HAND OPERATED SILENT STEEL ADC HEAVY DUTY CURTAIN TRACK MODELS: 280, 281, 282, 280-A, 283-N, 283-R

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs

IMPORTANT SAFETY INSTRUCTIONS:

MaxLite Linear Strip ECO Series

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

DETAILED ILLUSTRATION

BL-ER-P Ethernet Radio Unit for Pedestal Installation Guide

WOLF LOOM DOUBLE BACK BEAM

Custom Pendant- Hardwire Assembly and Installation Instructions

Fan, Eden/Northfield, GS Installation Instructions (SKU ) Packing List

INSTALLATION INSTRUCTION Solorail - Low Voltage Starter Kit

What you should have. 1. Telescopic Pole (1) 2. Arc tubing (4) for Lower Ring. 3. Numbered bars or spokes(8) 4. Center plate (1)

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

EchoPanel EchoScreen Installation Guide

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

SURFACE CLIP MOUNT. 1 Insert lens into channel, measure, and cut to length. Remove lens cover from channel. surface. Attach lens cover and end caps

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Cook's Corner Kitchen Assembly Instructions

PRS X-Axis Energy Chain (E-chain) Installation

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Assembly & Installation Instructions

Quantum 2 SQUARE 0808K

Mounting a BalanceBox 400 to a brick wall

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Assembly & Installation Instructions

Bluetooth DRO Installation for Bench Mills

INSTALLATION INSTRUCTIONS

Installation Instructions

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

GLASS GLOBE MOBILE LINEAR CHANDELIER

A59 APD & A86 CPD 5'X 16' SW ALUMINUM PORTA-DOCK

S A F T E Y W A R N I N G

BY ALIEN TECHNOLOGIES CORP

INSTALLATION GUIDE Ceiling TV Mount MHP-52

INSTALLATION INSTRUCTIONS

Installing the 3 Indexer: PRS Standard Tools

INSTALLATION INSTRUCTIONS

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

INSTALLATION INSTRUCTIONS

Important Safety Instructions

Tilting Flat Panel Wall Mount Installation Guide

mila-wall (Series100) General Operating Instructions page 1 of 15

FAIRFAX ROUGHING-IN K-12151T=673. UNIT: mm K-12153T K-12156T K-12151T=610 K-12157T K-12161T T01-A -1- INSTALLATION INSTRUCTIONS

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

QUANTUM 2 CIRCLE 24 Installation Instructions

Nash Chandelier Assembly and Installation Instructions

Monitor mount for 2016 E-series and E2417H Dell monitors. Installation guide

Assembly Instructions

Woven Leather Chandelier Large Assembly and Installation Instructions

QUANTUM 2 TRAPEZOID 2509 Installation Instructions

PRS X-Axis E-Chain Installation For Tools with a 12 Z-Axis

MyStudio VS53 Versa Sweep Setup Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

INSTALLATION INSTRUCTIONS

Transcription:

NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. J-BOX & CEILING CANOPY MOUNTING PLATE TEMPORARY CHAINS LABELED CABLE & CORD HOLES CANOPY w/ MOUNTED POWER SUPPLIES AND WIRES. (FIXTURES VARY, NOT ALL ARE SHOWN) ELEC. CORD STRAIN RELIEF SUSPENSION CABLES UPPER DIFFUSER CABLE ADJUSTERS NOTE: DO NOT OVERTIGHTEN SCREWS LIGHT BAR LOWER DIFFUSER 8-32 x 3/16" CONE POINT SET SCREW

NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. CONTENTS (1) Rectangular Canopy 36" L x 18" W (1) Canopy Mouting Frame (3) Light Bar, Electrical Cord and pre-installed Strain Relief with Set Screw (3) Lower Acrylic Diffuser (3) Upper Acrylic Diffuser (6) Suspension Cables, Labeled and pre-marked with insertion depth (4) Canopy Mounting Screws (#10-32) (4) Temporary Chains w/ S-Hooks (3) Hex Wrench 1/16, 5/64, 1/8 (4) Sets of Gloves to be worn during installation. NOTE: DO NOT OVERTIGHTEN SCREWS UL Approved in US and Canada

PLEASE USE THE FOLLOWING DIAGRAM AND STEPS FOR INSTALLATION NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. INSTRUCTIONS 1. Determine fixture location, J Box should be located on the center of the Fixture. 2. Screw Canopy Mounting Plate to ceiling w/ appropriate screws and/or anchors per installation requirements. (Mounting requirements and hardware to be determined and provided by installer) 3. Hang Temporary Chains from Canopy Mounting Plate; raise Canopy to hang from Temporary Chains, note alignment mark on Canopy Mounting Plate and Canopy. NOTE: TEMPORARY CHAINS ARE NOT MEANT TO BE LEFT SUSPENDING THE FIXTURE FOR EXTENDED PERIODS OF TIME 4. Connect 110-277 Volt power to pre-wired fixture (black and white wires). All power supplies have been installed by manufacturer. The drivers installed in this unit have multiple methods of dimming to accommodate your needs. The systems are capable of Triac dimming at 120 VAC or have the option for 0-10 vdc current-sinking control for dimming. 5. Make Electrical connections to fixture based on dimming type or controls with provided wiring diagrams supplied with dimming or control options. (See next page for diagrams.) This fixture can be wired to accept Triac dimming or 0-10V dimming or switch (the 0-10V dimming signal must be supplied to the purple and gray wires as there is no reference voltage supplied from the driver for this dimming option)). If no dimming is required cap gray and purple wires from the driver and install a nondimming switch wired per switch instructions. 6. Slide the labeled Suspension Cables into corresponding holes through top of Canopy. 7. Match the Light Bars to their corresponding labels in the Canopy and hang all Light Bars from the Suspension Cables with Cable Adjusters to the insertion depth marked on the Cables. 8. Loosen Set Screws pre-installed in Strain Reliefs with provided Hex Wrench. 9. Uncoil silver cloth covered Elec. Cord and feed through Strain Reliefs. Snug the set screw in the Strain Relief against the Cord when the Cord is hanging straight---do NOT OVERTIGHTEN. 10. Make electrical connections with Snap Connectors at labeled positions in Canopy. Connect to Supply Power with wire nuts and Ground to Canopy. 11. Remove pre-installed 8-32 x 3/16" Cone Point Set Screws from ends of Light Bars using provided Hex Wrench. Reaise each numbered Lower Diffuser to the corresponding Light Bar and secure into bottom slot by re-installing Cone Point Set Screws. DO NOT OVERTIGHTEN SCREWS. 12. Install Upper Diffusers into Light Bars. 13. Remove Temporary Chains and raise the Canopy to the Canopy Mounting Plate. Secure with provided 10-32 screws (start all screws before final tightening). 14. Based on site conditions, a slight leveling of Light Bars may be necessary. Pressing the center cylinder of the Cable Adjuster will release pressure on the Cable and Light Bar can be repositioned.

HOLLY HUNT STUDIO NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. 0-10V Dimmer Switch Ref. Control Module Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM FOR 0-10V DIMMING To 120/240V J-Box Wire Nut Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM WITHOUT DIMMING REFERENCE TRIAC WIRING DIAGRAM Triac Dimmer Wire Nut Light Bar Below Light Bar Below

NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. J-BOX & CEILING CANOPY MOUNTING PLATE TEMPORARY CHAINS LABELED CABLE & CORD HOLES CANOPY w/ MOUNTED POWER SUPPLIES AND WIRES. (FIXTURES VARY, NOT ALL ARE SHOWN) ELEC. CORD STRAIN RELIEF SUSPENSION CABLES UPPER DIFFUSER CABLE ADJUSTERS NOTE: DO NOT OVERTIGHTEN SCREWS LIGHT BAR LOWER DIFFUSER 8-32 x 3/16" CONE POINT SET SCREW

CONTENTS (1) Rectangular Canopy 72" L x 18" W (1) Canopy Mouting Frame (5) Light Bar, Electrical Cord (5) Strain Reliefs with Nylon Tip Set Screw Installed (5) Lower Acrylic Diffuser (5) Upper Acrylic Diffuser (10) Suspension Cables, Labeled and pre-marked with insertion depth (6) Canopy Mounting Screws (#10-32) (4) Temporary Chains w/ S-Hooks (3) Hex Wrench 1/8", 1/16" and 5/64" (4) Sets of Gloves to be worn during installation. (2) Extra Butt Connector (2) 8-32 x 3/16 or 1/4 Cone Point SS, Pre-installed per Light Bar (5) Wire Nuts NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. NOTE: DO NOT OVERTIGHTEN SCREWS UL Approved in US and Canada

PLEASE USE THE FOLLOWING DIAGRAM AND STEPS FOR INSTALLATION NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. INSTRUCTIONS 1. Determine fixture location, J Box should be located on the center of the Fixture. 2. Screw Canopy Mounting Plate to ceiling w/ appropriate screws and/or anchors per installation requirements. (Mounting requirements and hardware to be determined and provided by installer) 3. Hang Temporary Chains from Canopy Mounting Plate; raise Canopy to hang from Temporary Chains, note alignment mark on Canopy Mounting Plate and Canopy. NOTE: TEMPORARY CHAINS ARE NOT MEANT TO BE LEFT SUSPENDING THE FIXTURE FOR EXTENDED PERIODS OF TIME 4. Connect 110-277 Volt power to pre-wired fixture (black and white wires). All power supplies have been installed by manufacturer. The drivers installed in this unit have multiple methods of dimming to accommodate your needs. The systems are capable of Triac dimming at 120 VAC or have the option for 0-10 vdc current-sinking control for dimming. 5. Make Electrical connections to fixture based on dimming type or controls with provided wiring diagrams supplied with dimming or control options. (See next page for diagrams.) This fixture can be wired to accept Triac dimming or 0-10V dimming or switch (the 0-10V dimming signal must be supplied to the purple and gray wires as there is no reference voltage supplied from the driver for this dimming option)). If no dimming is required cap gray and purple wires from the driver and install a nondimming switch wired per switch instructions. 6. Slide the labeled Suspension Cables into corresponding holes through top of Canopy. 7. Match the Light Bars to their corresponding labels in the Canopy and hang all Light Bars from the Suspension Cables with Cable Adjusters to the insertion depth marked on the Cables. 8. Loosen Set Screws pre-installed in Strain Reliefs with provided Hex Wrench. 9. Uncoil silver cloth covered Elec. Cord and feed through Strain Reliefs. Snug the set screw in the Strain Relief against the Cord when the Cord is hanging straight---do NOT OVERTIGHTEN. 10. Make electrical connections with Snap Connectors at labeled positions in Canopy. Connect to Supply Power with wire nuts and Ground to Canopy. 11. Remove pre-installed 8-32 x 3/16" Cone Point Set Screws from ends of Light Bars using provided Hex Wrench. Reaise each numbered Lower Diffuser to the corresponding Light Bar and secure into bottom slot by re-installing Cone Point Set Screws. DO NOT OVERTIGHTEN SCREWS. 12. Install Upper Diffusers into Light Bars. 13. Remove Temporary Chains and raise the Canopy to the Canopy Mounting Plate. Secure with provided 10-32 screws (start all screws before final tightening). 14. Based on site conditions, a slight leveling of Light Bars may be necessary. Pressing the center cylinder of the Cable Adjuster will release pressure on the Cable and Light Bar can be repositioned.

HOLLY HUNT STUDIO NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. 0-10V Dimmer Switch Ref. Control Module Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM FOR 0-10V DIMMING To 120/240V J-Box Wire Nut Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM WITHOUT DIMMING REFERENCE TRIAC WIRING DIAGRAM Triac Dimmer Wire Nut Light Bar Below Light Bar Below

NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. J-BOX & CEILING CANOPY MOUNTING PLATE TEMPORARY CHAINS LABELED CABLE & CORD HOLES CANOPY w/ MOUNTED POWER SUPPLIES AND WIRES. (FIXTURES VARY, NOT ALL ARE SHOWN) ELEC. CORD STRAIN RELIEF SUSPENSION CABLES UPPER DIFFUSER CABLE ADJUSTERS NOTE: DO NOT OVERTIGHTEN SCREWS LIGHT BAR LOWER DIFFUSER CONE POINT SET SCREW

NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. CONTENTS (1) Rectangular Canopy 108" L x 18" W (1) Canopy Mouting Frame (7) Light Bar, Electrical Cord and pre-installed Strain Relief with Set Screw (7) Lower Acrylic Diffuser (7) Upper Acrylic Diffuser (14) Suspension Cables, Labeled and pre-marked with insertion depth (10) Canopy Mounting Screws (#10-32) (4) Temporary Chains w/ S-Hooks (1) Hex Wrench (4) Sets of Gloves to be worn during installation. NOTE: DO NOT OVERTIGHTEN SCREWS UL Approved in US and Canada

PLEASE USE THE FOLLOWING DIAGRAM AND STEPS FOR INSTALLATION NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. INSTRUCTIONS 1. Determine fixture location, J Box should be located on the center of the Fixture. 2. Screw Canopy Mounting Plate to ceiling w/ appropriate screws and/or anchors per installation requirements. (Mounting requirements and hardware to be determined and provided by installer) 3. Hang Temporary Chains from Canopy Mounting Plate; raise Canopy to hang from Temporary Chains, note alignment mark on Canopy Mounting Plate and Canopy. NOTE: TEMPORARY CHAINS ARE NOT MEANT TO BE LEFT SUSPENDING THE FIXTURE FOR EXTENDED PERIODS OF TIME 4. Connect 110-277 Volt power to pre-wired fixture (black and white wires). All power supplies have been installed by manufacturer. The drivers installed in this unit have multiple methods of dimming to accommodate your needs. The systems are capable of Triac dimming at 120 VAC or have the option for 0-10 vdc current-sinking control for dimming. 5. Make Electrical connections to fixture based on dimming type or controls with provided wiring diagrams supplied with dimming or control options. (See next page for diagrams.) This fixture can be wired to accept Triac dimming or 0-10V dimming or switch (the 0-10V dimming signal must be supplied to the purple and gray wires as there is no reference voltage supplied from the driver for this dimming option)). If no dimming is required cap gray and purple wires from the driver and install a nondimming switch wired per switch instructions. 6. Slide the labeled Suspension Cables into corresponding holes through top of Canopy. 7. Match the Light Bars to their corresponding labels in the Canopy and hang all Light Bars from the Suspension Cables with Cable Adjusters to the insertion depth marked on the Cables. 8. Loosen Set Screws pre-installed in Strain Reliefs with provided Hex Wrench. 9. Uncoil silver cloth covered Elec. Cord and feed through Strain Reliefs. Snug the set screw in the Strain Relief against the Cord when the Cord is hanging straight---do NOT OVERTIGHTEN. 10. Make electrical connections with Snap Connectors at labeled positions in Canopy. Connect to Supply Power with wire nuts and Ground to Canopy. 11. Remove pre-installed 8-32 x 3/16" Cone Point Set Screws from ends of Light Bars using provided Hex Wrench. Reaise each numbered Lower Diffuser to the corresponding Light Bar and secure into bottom slot by re-installing Cone Point Set Screws. DO NOT OVERTIGHTEN SCREWS. 12. Install Upper Diffusers into Light Bars. 13. Remove Temporary Chains and raise the Canopy to the Canopy Mounting Plate. Secure with provided 10-32 screws (start all screws before final tightening). 14. Based on site conditions, a slight leveling of Light Bars may be necessary. Pressing the center cylinder of the Cable Adjuster will release pressure on the Cable and Light Bar can be repositioned.

HOLLY HUNT STUDIO NOTE: CLEAN GLOVES MUST BE WORN DURING INSTALLATION. DO NOT REMOVE PAPER FROM ACRYLIC DIFFUSER UNTIL INSTALLATION IS COMPLETE. 0-10V Dimmer Switch Ref. Control Module Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM FOR 0-10V DIMMING To 120/240V J-Box Wire Nut Light Bar Below Light Bar Below REFERENCE WIRING DIAGRAM WITHOUT DIMMING REFERENCE TRIAC WIRING DIAGRAM Triac Dimmer Wire Nut Light Bar Below Light Bar Below