Mounting Instruction. Compact Mini EGC Amplifier and Application

Similar documents
GainMaker Node SMC Status Monitor Transponder Installation Instructions

Cisco Compact Micro Amplifier A Installation and Operation Guide

Compact Nodes and 90071

Compact Node Optoelectronics

GS7000, GainMaker, and 694X Node Transmitter RF Shutdown Technical Bulletin

GainStar 1 GHz Node with 42/54 MHz Split

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

Using 1 GHz GainMaker Amplifiers in an 870 MHz System Application Note

GainMaker Optoelectronic Node 1 GHz with 40/52 MHz Split and RF Redundancy

ACE3 INTELLIGENT BROADBAND AMPLIFIER

Transponder for GainMaker Optoelectronic Node

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

AC2000 AMPLIFIER PLATFORM

GainMaker High Output Reverse Segmentable Node with 40/52 MHz Split

CXE880 FIBRE OPTIC NODE

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

AC1000 AMPLIFIER & OPTICAL NODE PLATFORM

OPTICAL NODE TRUNK & DISTRIBUTION

AC3000 INTELLIGENT BROADBAND AMPLIFIER

CXE880 FIBRE OPTIC NODE

GainMaker High Output Node 5-40/ MHz

Downstream signal path (values with diplex filters)

Model 6940 Collector/Terminator Three Port Unbalanced Optoelectronic Node 870 MHz with 65/86 MHz Split

GainMaker High Output HGBT System Amplifier 5-40/ MHz

CXE880 FIBRE OPTIC NODE

CXE880 FIBRE OPTIC NODE

AC GHZ DISTRIBUTION AMPLIFIER

User Manual CXE Rev.002 Broadband Cable Networks March 3, (10) CXX Series. User Manual. Teleste Corporation CXE880.

AC500 AMPLIFIER PLATFORM

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

GainMaker Line Extender 1 GHz with 42/54 MHz Split

Program and System Information Protocol Configuration for System Releases 2.5, 2.7, 3.5, 3.7, 4.0, 4.2, and CV 3.4

GainMaker High Output 4-Port Node

AC GHZ DISTRIBUTION AND TRUNK AMPLIFIER

Cisco GainMaker High Output High Gain Balanced Triple 1 GHz System Amplifier 5-85/ MHz

RCDAT The Big Deal

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Downstream signal path (values with diplex filters) Upstream signal path (values with diplex filters)

RCDAT The Big Deal

GainMaker Line Extender 1 GHz with 65/86 MHz Split

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

GainMaker High Gain Balanced Triple System Amplifier 1 GHz with 40/52 MHz Split

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

RC4DAT-6G-60. The Big Deal

Prisma II 1 GHz SuperQAM Full Spectrum Transmitter

ISW-EN7016 Installation Guide

GainMaker Unbalanced Triple System Amplifier 1 GHz with 42/54 MHz Split

GainMaker Broadband Amplifier Platform System Amplifier Modules and Housing Installation and Operation Guide

SV613 USB Interface Wireless Module SV613

USB/RS232 Variable Attenuator

AC800 FIBRE OPTIC NODE

GainMaker Optoelectronic Node 1 GHz with 42/54 MHz Split

GainMaker Low Gain Dual System Amplifier 1 GHz with 55/70 MHz Split

GainMaker Unbalanced Triple System Amplifier 870 MHz with 40/52 MHz Split

Prisma II 1 GHz SuperQAM Transmitter

Model 6940 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

GainMaker 1 GHz High Output 4-Port Node with 40/52 MHz Split

ODN4P. Optical Distribution Node, Four Ports. About the Product

CATV Product Family MEDIALINE 2000

ACE2 INTELLIGENT BROADBAND AMPLIFIER

Compact Reverse Transmitters with DFB or CWDM Lasers

PI-150 Broadband Power Indicator

1 GHz SASMAX II series

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

PI-10 Broadband Power Indicator

AC8000 FIBRE OPTIC PLATFORM

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

ANTENNAFIER TM 915LTX BLOCK DIAGRAM LNA

TriMode Probe Family P7700 Series TriMode Probes

Models 1421 and 1422 User s Manual. Broadband Amplifiers

Q-SERIES. Amplifiers. QPAIR Redundancy Switch Amplifier System. Installation & Operation Manual

INSTALLATION AND OPERATING MANUAL

AC9000 INTELLIGENT FIBRE OPTIC PLATFORM

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

MODEL BTN GHz OPTICAL NODE STARLINE SERIES

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

CXE180 UNIVERSAL AMPLIFIER

ACE8 1.2 GHZ INTELLIGENT OPTICAL NODE

Configuring Trimble R10 For New Frequency and Baud Rate

Model 6942 Four Port Optoelectronic Node 870 MHz with 42/54 MHz Split

Agilent 8762F Coaxial Switch 75 ohm

Ameritron ALS-600 Retrofit ALS-600-LPF Assembly Manual

PRO Professional Radio Control Series Applications

Antenna Splitter ASA 1. Instruction manual

Prisma II Reverse Video Receiver and Reverse Data Receiver Installation and Operation Guide

RUDAT The Big Deal. Applications

CXE202 UNIVERSAL AMPLIFIER

Radio Control Installation and Operating Instructions System 4

INSTRUCTION MANUAL OTOT-1000C-FQ WIDE-BAND 1550NM DIRECT-MOD QAM TRANSMITTER. 1,000 MHz Bandwidth / Optical Output Power is +9dBm (OTOT-1000C-09-FQ)

Disclaimers. Important Notice

Dragon. manual version 1.7

RC4DAT-6G-95. Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

AC 3. Active Antenna Combiner. Instruction manual

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Cisco 1.2 GHz GainMaker System Amplifier Installation and Operation Guide

TELESTE AC NODE SPECIFIC MODULES

TELESTE AC AMPLIFIER MODULES

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Transcription:

Mounting Instruction Compact Mini EGC Amplifier 93230 and 93240 Application The Compact Mini EGC Amplifier type 93230 and type 93240 has one active output and is mainly used as distribution amplifier. The only different between the two types is that ROSA Element Management System cannot monitor the 93230. All equalizers and pads are electronic and can be set with the handheld terminal type 91200. The plug-in filters in the reverse path allow flexible choice of frequency range for both forward and reverse path. Low Voltage Lockout Typ 75018-xx Only in 65/90 V types Mounting fittings Distance between holes 168 mm. / 6.6 in. AC connection Max. 7 A at remote supply Power Supply Fuse 3.15 AT at remote supply 2.0 AT at mains supply Diplex filter 2 pcs Type 75130-xxxx xxxx is the split freq. If no reverse wanted; Use 0 db link type 74089 Reverse Equalizer Type 74141-xx Input Test point -20 db Bi-directional Fuses (turnable) 6.3 A T Choose AC-pass Diplex in 1 93240-138 93240-238 93240-338 93240-938 28/38dB Forward Eq Att Att Eq 2 3 4 5-9? 18dB 0? 18dB 0? 6dB 6.3AT Eq Att 8 7 6 0? 15dB Transponder 0? 18dB 25dB Reverse 6.3AT Att 0? 20dB 0? 15dB 1 Copy Parameters LCI Port i n. 21 m m a x. 24 m m Diplex out DC- voltage indicator LCI Port To setup the amplifier, the hand held terminal can be connected here Output Measure point, -20 db directional coupled, can be used as reverse insertion point Reverse Measure point, directional coupled Transponder Type 91051 Only in 93240 type Service Port in 93230 Connector PG11 at input and output Terminal for earthing Figure 1: Amplifier overview

Housing Dimensions The standard housing dimensions are 7.3 inches/185 mm x 5.7 inches/145 mm x 3.7 inches/95 mm. The distance from the top edge of the amplifier to its bottom edge is also 7.3 inches/185 mm, as long as its length. The distance between two RF ports is 6.5 inches/116 mm. The diagram below shows the dimensions of the amplifier housing. 2 Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 4010069 Rev F

To Mount the Amplifier CAUTION: Be aware of the size and weight of the amplifier when mounting. Ensure that the mounting location has a stable flat surface, and can safely support the amplifier s maximum weight. Please use the appropriate type of screws and screwdrivers, depending on the mounting method. Mounting Material: The amplifier should be mounted vertically with the cable input underneath, to allow natural ventilation and to secure the best possible operation conditions. Use a 4 mm Allen key for screw in lid and fasten with 5 Nm. The pin length of the PG 11 cable connector at input and output is shown on the cover plate of the amplifier. The amplifier can be mounted on the wall of concrete, brick, wood, metal, etc., or in the cabinet. Mounting Steps: 1 Use two mounting screws to mount the amplifier. The screw size is M5 and the distance between two mounting screws is 166 mm. 2 Tighten the two mounting screws. Make sure the amplifier is fixed steadily. See the following diagram for instructions: 4010069 Rev F Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 3

Please Notice: Plug-in units This product can only be setup with a hand held terminal type A91200.11 or with a hand held terminal type A91200.10 containing the necessary driver for the EGC amplifier. New drivers can be installed by means of download kit A91210.10. Three plug-in units are necessary. Two diplex filters type 75130 with the required split frequency. Use two links type 74089 if the reverse path not is used. Plug-in reverse equalizer type 74141 with the required filter frequency determines the frequency range for the built-in active reverse path. 230 V AC DC AC or DC in DC 0-18 db Equalizer or Cable simulator -9 to18 db 0-6 db 0-15 db µ- Controller TX Transponder RX -33dB 0/6/ 0-18 db Rev.Eq. 0-15 db 0-20 db TP TP Rev. TP IN OUT 1 Figure 2: Block diagram for the amplifier type 93230 and type 93240. The transponder and tri-state switch cannot be used in the amplifier type 93230 4 Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 4010069 Rev F

Power Supply 230 V (or 115 V) Mains Supply The amplifier has factory mounted mains cable and plugs, which according to approval provisions may not be altered. The power unit is double insulated, and supplies only this single amplifier. When the power unit DC voltage lights indicate the power unit is supplying correct DC voltage. Remote Supply 24-65 V AC (or 35-90 V AC) The amplifier can be supplied with 24-65 V AC either via coaxial cables (max. 5 A) or directly to the AC input (max. 7 A). AC Pass On delivery, ports are provided with insulating fuses. Desired AC pass is obtained by turning the fuse holder after connecting the cable or before disconnecting, to prevent damage of cable connectors. Permanent excess of max. Remote current implies a risk of damage. Low Voltage Lockout For all coax line powered power supplies an undervoltage switch type 75018-xx can be delivered that switches off the power supply if the voltage drops below the rated value (24 V or 35 V) thus, the network is not damaged due to increased current consumption. Setting up the amplifier The hand held terminal type 91200 is used to set up the amplifier. Use the menu structure below to navigate through the different menus. Shortcuts Use the short cuts shown on the cover plate to do a fast selection of the required menu. Ex. The output equalizer is marked with 5. By pressing the button 5 in approx. 1 sec. the terminal returns to the menu where the output equalizer can be is changed. The menu numbers can also be used as short cuts. Please see the menus structure below to determine the number for the required menu. Ex. Press 35 and the handheld terminal will return to the menu where the reverse switch can be set. 4010069 Rev F Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 5

Or use the following buttons: or or Is used to navigate to the submenus and to open a menu for editing. The value can then be changed. Additional the button can be used to reject a value entered by the keypad. Is used to navigate to the root menus and to delete wrong digits when a menu is open for editing. Additional the button can be used to reject a value entered by the keypad. Configuration 1 Fw 28dB/862M Configuration 1 Rv 25dB Forward 2 Toggling * Forward Gain 11 28 db Forward Freq. 12 862 MHz Reverse Gain 13 25 db Input EQ 21 + 5.0 db Input Att 22 + 5.0 db Interstage Att 23 + 5.0 db Interstage Att 2 24 + 5.0 db Output EQ 25 + 5.0 db ** 1 2 3 4 5 6 7 8 9 0 - E N TE R All numbers,. and - are used to enter values with. The numbers can also be used as short cuts. Is used to navigate through menus at the same level and to select the settings in some menus. Additional these buttons can be used to finetune some values. Is used to confirm a setting or a change. Reverse 3 Supply 4 Copy Parameters 5 Rev. Input Att 1 31 + 5.0 db Rev. Input Att 2 32 + 5.0 db Rev. Output Att 33 + 5.0 db Rev. Output EQ 34 + 5.0 db Rev. Switch 35 0 db Remote Supply 41 Not Connected From Product 51 To Product 52 Restore Default 53 ** In the menu Copy Parameters the setting of an amplifier can be saved (menu 51) and downloaded to another amplifier (menu 52). Identification 6 * old terminal design ** Not avaiable for this amplifier * Model Number 61 A93240.10238 Serial Number 62Time in 000423F0434 Service 63 Software ID 2 days 64Terminal SW 7003460-A 65 530445 Transponder 66 OK Lid Status 67 Open Lid status menu only in 93240 Figure 3: Menu structure 6 Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 4010069 Rev F

ROSA Element Management System in Type 93240 Monitoring of the amplifier requires the installation of the transponder type 91051 in the amplifier. This transponder will communicate back to the head-end by means of the reverse path. The transponder signal is received at the test point at output. Please see fig. 2. The level measured by the transponder will be attenuated by approx. 33 db relative to the output signal at output. The transponder transmitter level is adjusted to the same level as the other reverse signals. The level from the transponder will be attenuated by approx. 20 db at the reverse path since it is inserted with a 20 db coupler. With a transponder it is possible to monitor and control different parameters in the amplifier. As seen in Fig. 2, the built-in reverse path switch can be controlled in order to locate ingress noise in the reverse path This can be useful in the search for errors in larger networks. Programming of a Compact Transponder type 91051 is done by using the Handheld Terminal 91200. The transponder can be set with: SMC ID Transponder adress 1-65535 TX FREQ Transmit frequency 5-65 MHz RX FREQ Receive frequency 45-174 MHz TX LEVEL Transmit level 84-110 dbµv BAUD RATE Data speed 9.6-19.2-38.4 kbps MODE Transponder mode IEP Accessories Test adapter, F type A71004 Fuses 2AT, for 230 Vac A38008 2AT, for 115 VAC A38024 3.15AT, for 24-65 V (35-90 V) A38010 6.3 AT, for input/output port A38015 4010069 Rev F Mounting Instructions Compact Mini EGC Amplifier 93230 and 93240 7

For Information If You Have Questions Region Centers Customer Service Numbers North America USA Toll-free: 1-800-722-2009 Europe, Middle East, Africa Belgium Telephone: 32-56-445-133 or 32-56-445-118 Japan Japan Telephone: 81-3-5908-2153 or +81-3-5908-2154 Korea Korea Telephone: 82-2-6205-6004 China (mainland) China Telephone: 86-400-8108886 Press 4 at the prompt Other Asia-Pacific countries, Australia Hong Kong Telephone: 852-2522-5059 Brazil Brazil Telephone: 55-11-3845-9154, ext 109 Mexico, Central America, Caribbean Mexico Telephone: 52-55-50-81-8425 All other Latin America countries Argentina Telephone: 770-236-5662 Cisco Systems, Inc. 5030 Sugarloaf Parkway, Box 465447 Lawrenceville, GA 30042 678 277-1120 800 722-2009 www.cisco.com Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1009R) Specifications and product availability are subject to change without notice. 2012 Cisco and/or its affiliates. All rights reserved. June 2012 Part Number 4010069 Rev F