Performance of high-eciency photovoltaic systems in a maritime climate

Similar documents
Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

Accessing the performance. light processing projector

Validation of spectral response polychromatic method measurement of full size photovoltaic modules using outdoor measured data

Voltage-dependent quantum efficiency measurements of amorphous silicon multijunction mini-modules

Actual PV module performance including spectral losses in the UK

The Effect of Photon Flux Density and Module Temperature on Power Output of Photovoltaic Array

How to Evaluate PV Project Energy Yield

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

Review of uncertainty sources in indoor PV calibration of c-si, and thin film single junction and multi junction cells and modules

Application Note: String sizing Conext CL Series

Performance Loss of PV systems. Giorgio Belluardo

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

Advantages in using LEDS as the main light source in solar simulators for measuring PV device characteristics

Quality Assurance in Solar with the use of I-V Curves

Experimental Performance Characterization of Photovoltaic Modules Using DAQ

New Tools for PV Array Commissioning and Troubleshooting

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

BIPV System Performance under the Microscope: Analysis of High-Resolution Data

Tools for field testing

VERIFICATION OF MATHEMATICAL MODEL FOR SMALL POWER SOURCES

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

Laboratory 2: PV Module Current-Voltage Measurements

The European Commission s science and knowledge service

CLOSE-UP EXAMINATION OF PERFORMANCE DATA FOR A GRID-CONNECTED PV SYSTEM

Upsolar Smart Modules

INDOOR AND OUTDOOR CHARACTERIZAITION OF a-si:h P-I-N MODULES

Optimising Layer Thickness of Multi-Junction Silicon Devices for Energy Production in a Maritime Climate

THE DESERT KNOWLEDGE AUSTRALIA SOLAR CENTRE: HIGH VOLTAGE EFFECTS ON INVERTER PERFORMANCE.

Development of a solar cell spectral response mapping system using multi-lbic excitation

LOW VOLTAGE PV ARRAY MODEL VERIFICATION ON COMPUTER AIDED TEST SETUP

An Analysis of a Photovoltaic Panel Model

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Performance Evaluation of Solar Home Systems in Hot Climate Condition: mc-si PWM versus a-si MPPT Charge Controller System

School of Engineering and Information Technology ENG460. Engineering Thesis

Understanding Temperature Effects on Crystalline PV Modules

A STUDY ON THE EFFECTS OF SOLAR POWER. An Undergraduate Honors College Thesis. Jonathan Keith Hayes. University of Arkansas

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Optical design of a low concentrator photovoltaic module

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

A control strategy for PV stand-alone applications

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Design, construction and characterization of a steady state solar simulator

STUDY OF A PHOTOVOLTAIC SYSTEM WITH MPPT USING MATLAB TM

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

SOLARONIX. Solixon A-1525-V

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

Large Area Steady State Solar Simulator - Apollo

Week 10 Power Electronics Applications to Photovoltaic Power Generation

Proposed test procedure for the laboratory characterisation of gridconnected

Tel Fax

New Tools for PV Array Commissioning and Troubleshooting

Measurements and simulations of the performance of the PV systems at the University of Gävle

ENGINEERING THESISS ENG460

Operating Manual BENNING PV Link App

APPENDIX V PRODUCT SHEETS

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

Spectrally Selective Sensors for PV System Performance Monitoring

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Step-By-Step Check Response of PV Module Modeling Tested by Two Selected Power Reference Modules

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by:

Bending vibration measurement on rotors by laser vibrometry

Investigation of the Performance of a Large PV system

Understanding Potential Induced Degradation for LG NeON Model

A multi-band printed monopole antenna

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

PV Charger System Using A Synchronous Buck Converter

Antenna frequency and beam reconfliguring using photoconducting switches

A Revision of IEC nd Edition Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

Volume 11 - Number 19 - May 2015 (66-71) Practical Identification of Photovoltaic Module Parameters

SINGLE-DIODE AND TWO-DIODE PV CELL MODELING USING MATLAB FOR STUDYING CHARACTERISTICS OF SOLAR CELL UNDER VARYING CONDITIONS

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

DETAILED MONITORING AND PRELIMINARY EVALUATION OF A LARGE FAÇADE-MOUNTED PV ARRAY

4. Renewable Energy Sources. Part B1: Solar Electricity

Abstract. silicon photovoltaic (PV) system on the roof of the Alternative Fuel Vehicle Garage of the

Measurement and Monitoring of Performance Parameters of Distributed Solar Panels using Wireless Sensors Network

Traditional PWM vs. Morningstar s TrakStar MPPT Technology

FIELD MEASUREMENTS OF PV MODULE PERFORMANCE USING A HANDY TOOL

Optimization of the electronic Driver and thermal management of LEDs lighting powered by solar PV

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer

Practical Evaluation of Solar Irradiance Effect on PV Performance

SILICon IrrADIAnCe SenSor

Bifacial Outdoor Rotor Tester- BIFROT

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM

Performance Evaluation, Simulation and Design Assessment of the 56 kwp Murdoch University Library Photovoltaic System

Cylindrical electromagnetic bandgap structures for directive base station antennas

UNCONVENTIONAL AND OPTIMIZED MEASUREMENT OF SOLAR IRRADIANCE IN BENGALURU USING PHOTOVOLTAIC TECHNIQUES

Solar Cell I-V Characteristics

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

Traditional PWM vs Morningstar s TrakStar MPPT Technology

USER S GUIDE. for MIDDLETON SOLAR SECONDARY STANDARD PYRANOMETER WITH INTEGRATING CAVITY DETECTOR

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore.

Teacher Page. Understanding Solar Energy. Photovoltaic Power Output & I-V Curves. Student Objective

Advanced Test Equipment Rentals ATEC (2832)

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

Multi-band material loaded Low-SAR antenna for mobile handsets

Project report: FS10 UK

Simulink Based Analysis and Realization of Solar PV System

Transcription:

Loughborough University Institutional Repository Performance of high-eciency photovoltaic systems in a maritime climate This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation: STROBEL, M.B.... et al, 2006. Performance of high-eciency photovoltaic systems in a maritime climate. IN: 2nd Renewable Energy in Maritime Island Climates Conference, Proceedings, Dublin, 26-28 April. Additional Information: This is a conference paper. Metadata Record: https://dspace.lboro.ac.uk/2134/5121 Version: Accepted for publication Publisher: The Solar Energy Society (UK-ISES) Please cite the published version.

This item was submitted to Loughborough s Institutional Repository (https://dspace.lboro.ac.uk/) by the author and is made available under the following Creative Commons Licence conditions. For the full text of this licence, please go to: http://creativecommons.org/licenses/by-nc-nd/2.5/

Performance of High-efficiency Photovoltaic Systems in a Maritime Climate M.B. Strobel 1,2 R.Gottschalg 1, C.R. Chaplin 2, D.G.Infield 1 1 Centre for Renewable Energy Systems Technology (CREST), Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK Tel.: +44 1509 228631; Fax: +44 1509 610031, Email:m.strobel@reading.ac.uk 2 School of Construction Management and Engineering, Whiteknights, University of Reading, Berkshire, RG6 6AY, UK Introduction Today more than 80% of all installed PV power in the UK is generated from gridconnected photovoltaic (PV) systems [1]. Currently the energy generated is not remunerated preferentially in the UK, but in the future the energy yield of photovoltaics will gain in importance over an ideal-case power rating. The challenge here is to design highly efficient systems in order to arrive at cost-effective PV solutions. Advances in PV have resulted in new high-efficiency modules being introduced into the marketplace, promising superior performance in terms of efficiency (i.e. kwh/m 2 ) as well as specific energy yield (i.e. kwh/kwp). These promises can only be fulfilled if the complete system is able to capitalise on the advances in the module technology, as the BOS components play possibly the most significant role in the energy production in maritime climates. A programme to validate these promises has been started and initial work is reported. The long term aim of this research is to model not only the module performance with regard to irradiation, temperature and spectrum, but also their performance in gridconnected systems. The model will cover the whole system, from single modules, to DC-AC generation and mismatch. A measurement campaign has been designed to allow validation of the model. Experimental Design The study is set up to investigate the system performance of three commercially available high-efficiency technologies under real operating conditions in a maritime climate. In order to separate the effects that mainly influence system performance, the study consists of the following three stages: I. PV performance II. Module inverter pair performance III. Full system performance I. PV performance A SPIRE 240A flash solar simulator (see Figure 1) at the Centre for Renewable Energy Systems Technology (CREST) is used to measure I-V characteristics of modules to characterise their performance under standard test conditions (STC). Figure 1 Picture of the CREST SPIRE 240 solar simulator (left) with its control unit (right).

Such I-V characteristics were produced for each module under STC before their first outdoor installation to determine the effect of degradation from outdoor exposure. The modules were then added to the CREST outdoor measurement system (COMS3) where outdoor I-V characteristics (including module temperatures) are measured in ten minute intervals. Environmental parameters are recorded every five seconds, including diffuse, horizontal, in-plane irradiance, spectra, ambient air temperature, relative humidity, wind speed and direction. For further details refer to [2]. II. Module inverter pair performance To investigate the effects of MPP-tracking and inverter efficiency on system performance two differently sized module inverter types were used (120W and 150W) with two different modules of the same technology at the same time. Each module - inverter pair will be referred to as a minisystem. Figure 2 shows a schematic layout of the mini system set-up. 2 mini systems A 2 mini systems B 2 mini systems C A A B B C C Figure 3 Test version of a mini-system to monitor IDC, VDC, IAC, VAC and temperatures (PT-100) from two highefficieny mini-systems. III. Full system performance In the third stage of the monitoring study, the effects of PV arrays on system performance are investigated. Therefore, a PV system consisting of six 180Wp modules connected in 2 strings to an 850W string inverter has been monitored for one year. The system was mounted on the rooftop of a four storey building in London, close to Waterloo station facing 10 degrees east of south and tilted at a 35 degree angle (see Figure 4). Figure 2 The mini-system set-up each technology (capital letters) is connected to two differently sized inverters forming a mini system. Grid The measurements include DC and AC current and voltages, module temperatures and intermittent module I-V curves every 10 minutes. The data is collected via a National Instruments (NI) M-series DAQ card that is controlled by a LabView programme. In the figure below, a prototype data acquisition system for two mini-systems is shown. Figure 4 Picture of a 1kWp high-efficiency system on a roof top in London. Data from the system include DC and AC current and voltages, in-plane irradiance, ambient and module temperature. All measurements were taken at 30 second intervals with a NI Field Point FP-2000 data logger via three input modules: two AI-100 analogue input modules (8 channels, 12bit) for recording voltage and current signals and

a TC-120 thermocouple module (8 channels, 16bit). Custom-designed voltage divider and Hall Effect transducer circuits were used for DC voltage and current measurements. AC current and voltage were measured with a Northern Design Multi Cube multimeter in combination with an industrial ring-type AC current transducer. The latter was soon abandoned due to non-linear response in the predominant current range. Figure 5 shows a photograph of the monitoring system in its enclosure indoors. Results and Analysis I. PV performance The figure below shows a screenshot of the programme used to extract parameters from SPIRE I-V measurements. Figure 6 I-V characteristics for a Sanyo HIB 190Wp module measured in the SPIRE solar simulator. The datasheet values for the module under investigation agree well within 4% of the results from the SPIRE measurements. Figure 5 Picture of the monitoring system. The FP-2000 data logger (left) records DC current from a current transducer box (top right) and DC voltage from a voltage divider box (middle right). AC current and voltage are recorded from the output of a ND Multi Cube multimeter (bottom right). In-plane irradiance was measured with a Kipp&Zonen SP LITE silicon pyranometer. A free-hanging thermocouple behind the array is used to record ambient temperature while thermocouples glued onto the backside of modules were used to record module temperatures. The DAQ system was controlled by a LabView program running on a separate measurement PC that was also used for data storage. Datasheet value Measured value Differen ce [±%] Pmax 180.5-190 185.69 2.3-2.9 [W] Voc [V] 67.5 66.31 1.8 Isc [A] 3.75 3.714 1 Vmpp 54.8 52.88 3.6 [V] Impp [A] 3.47 3.512 1.2 Table 1 Datasheet [3] and measured values for a Sanyo HIP-190BE3 module under STC. The values for maximum power (P max ), open-circuit voltage (V oc ), short-circuit current (I sc ) and the maximum power point voltage (V mpp ) and current (I mpp ) from measurement were extracted from a SPIRE I-V scan. II. Module inverter pair performance First results from the monitoring of two mini-systems with the prototype monitoring system are shown in Figure 7. One minisystem consisted of a 120W Mastervolt Soladin module inverter and a 180W BP7180 monocrystalline module while the other one featured the same inverter but on two polycrystalline Kyocera KC80 modules.

The two hour sample indicates an average real PV efficiency of 9.7% (14.3% STC) for the BP module and 7.0% (14% STC) for the Kyocera modules. The comparatively low value for the latter is a direct result of shading which covered about 6% of the module surface. The average inverter efficiency for the Kyocera system is calculated at 95% and 88% which is interesting given the datasheet value of 93%. The system suffers from high levels of noise on temperature and AC signals which might be the cause for a higher than expected AC power. A suitable filter is currently being installed which is expected to improve the quality of the AC data significantly. However, long-term data will be needed to confirm the initial real performance results. The prototype has demonstrated though that the chosen monitoring method is suitable to collect the desired data from mini-systems. Current (A) 2.5 2 1.5 1 0.5 0 Outdoor IV characteristic 0 10 20 30 40 50 60 70 Voltage (V) Figure 8 Outdoor I-V curve for a Sanyo HIP-J54BE2 module measured with a PVPM2540C I-V tracer in April. The module temperature was 39 C and the incident in-plane irradiance 553W/m2. The next figure shows the normalised DC power generated for June with respect to irradiance. 600 DC power vs irradiance June 120 100 80 60 40 20 0 Power (W) 500 PDC (W) 400 300 200 100 0 0 100 200 300 400 500 600 700 800 900 Irradiance (W/m2) Figure 9 DC power generation over incident in-plance irradience for June. Figure 7 Prototype power measurements shows the typical power output for DC and AC power for two different modules. With a sampling rate of 10Hz the whole graph represents 140 minutes. The specific energy yield for June was calculated to be 86.1 kwh/kwp compared to 15.1kWh/kWp for January. The variation in real efficiency of the module arrays with DC input power is shown in the figure below. III. Full system performance 1.2 Inverter efficiency June Outdoor I-V characteristics (see Figure 8) were measured for all the panels used in the 1kWp system before the installation of the system. Inverter efficiency (%) 1 0.8 0.6 0.4 0.2 0 0 0.1 0.2 0.3 0.4 DC input power/nom. Inverter power Figure 10 Inverter efficiency with respect to DC input power over nominal input power

The mean real DC efficiency is 16.9% in June and 16.8% in January. The conversion into AC power is heavily dependent on incident DC input power which again depends on irradiance (see the figure below). The mean inverter efficiency was found to be 92% in January. Conclusions It has been shown that the chosen method of assessing outdoor system performance in three stages can indeed help to investigate separately the effects of module, inverter and array losses on real system performance. The performance data shows that highefficiency technologies perform very well in real maritime conditions and efficiencies of nearly 17% have been observed. The power delivered to the grid is limited by the inverter performance which shows a significant decrease below 20% of its nominal power. The data acquisition system for the minisystems suffers from high signal noise levels and a filter is currently being installed. Also, the COMS3 environmental data will be available for all future measurements including the systems which will allow investigation into the spectral effects on system performance. The generated data will be used as input to a novel model for system yield predictions, currently under development.

Acknowledgements The author would like to thank the EPSRC, the School of Construction Management and Engineering at the University of Reading and Solarcentury Ltd for supporting this research. References 1. IEA, IEA PVPS: TRENDS IN PHOTOVOLTAIC APPLICATIONS. 2005. 2. M. Bliss, T.R. Betts, R. Gottschalg, and D.G. Infield. Improved Outdoor Monitoring of Photovoltaic Modules. in 2nd Photovoltaic Science, Applications and Technology Conference. 2005. 3. SANYO. HIT Photovoltaic Module HIP-190BE3 datasheet: Sanyo Electric Co., Ltd.