taccor Optional features Overview Turn-key GHz femtosecond laser

Similar documents
venteon Ultra-short pulse oscillators

ignis TECHNICAL DATA SHEET high specification red laser CW 660nm laser Extremely low noise Power 500mW

gem TECHNICAL DATA SHEET CW 532nm laser Extremely low noise Power from 50mW - 750mW 532nm high spec OEM laser

High Power and Energy Femtosecond Lasers

TIGER Femtosecond and Picosecond Ti:Sapphire Lasers. Customized systems with SESAM technology*

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

High-Power Femtosecond Lasers

A new picosecond Laser pulse generation method.

The All New HarmoniXX Series. Wavelength Conversion for Ultrafast Lasers

pulsecheck The Modular Autocorrelator

Testing with Femtosecond Pulses

A transportable optical frequency comb based on a mode-locked fibre laser

Designing for Femtosecond Pulses

Femtosecond optical parametric oscillator frequency combs for high-resolution spectroscopy in the mid-infrared

Spider Pulse Characterization

How to build an Er:fiber femtosecond laser

TIMING DISTRIBUTION AND SYNCHRONIZATION COMPLETE SOLUTIONS FROM ONE SINGLE SOURCE

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance. Vitara Features:

APE Autocorrelator Product Family

Ultrafast instrumentation (No Alignment!)

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

Using GNSS for optical frequency and wavelength measurements

Optical phase-coherent link between an optical atomic clock. and 1550 nm mode-locked lasers

Integrated disruptive components for 2µm fibre Lasers ISLA. 2 µm Sub-Picosecond Fiber Lasers

VELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group

Femtosecond Synchronization of Laser Systems for the LCLS

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Picosecond Pulses for Test & Measurement

Testing with 40 GHz Laser Sources

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Wavelength Control and Locking with Sub-MHz Precision

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Recent Progress in Pulsed Optical Synchronization Systems

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Progress in ultrafast Cr:ZnSe Lasers. Evgueni Slobodtchikov, Peter Moulton

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

High-Power Highly Linear Photodiodes for High Dynamic Range LADARs

Narrow line diode laser stacks for DPAL pumping

Features. Applications. Optional Features

Aurora II Integra OPO Integrated Nd:YAG Pumped Type II BBO OPO

The Theta Laser A Low Noise Chirped Pulse Laser. Dimitrios Mandridis

Supercontinuum Sources

Mira OPO-X. Fully Automated IR/Visible OPO for femtosecond and picosecond Ti:Sapphire Lasers. Superior Reliability & Performance. Mira OPO-X Features:

Vitara. Automated, Hands-Free Ultrashort Pulse Ti:Sapphire Oscillator Family. Superior Reliability & Performance

SUPPLEMENTARY INFORMATION DOI: /NPHOTON

ULTRAFAST LASER DIAGNOSTICS

Nonlinear Optics (WiSe 2015/16) Lecture 9: December 11, 2015

Ultrahigh precision synchronization of optical and microwave frequency sources

R. J. Jones Optical Sciences OPTI 511L Fall 2017

improved stability (compared with

Diode Laser Control Electronics. Diode Laser Locking and Linewidth Narrowing. Rudolf Neuhaus, Ph.D. TOPTICA Photonics AG

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

Active mode-locking of miniature fiber Fabry-Perot laser (FFPL) in a ring cavity

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

NL300 series. Compact Flash-Lamp Pumped Q-switched Nd:YAG Lasers FEATURES APPLICATIONS NANOSECOND LASERS

Mode-locking and frequency beating in. compact semiconductor lasers. Michael J. Strain

Fiber Laser Chirped Pulse Amplifier

Supplementary Figures

Romania and High Power Lasers Towards Extreme Light Infrastructure in Romania

PCS-150 / PCI-200 High Speed Boxcar Modules

Fast Widely-Tunable CW Single Frequency 2-micron Laser

Flash-lamp Pumped Q-switched

RF-based Synchronization of the Seed and Pump-Probe Lasers to the Optical Synchronization System at FLASH

A 40 GHz, 770 fs regeneratively mode-locked erbium fiber laser operating

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Directly Chirped Laser Source for Chirped Pulse Amplification

PLL Synchronizer User s Manual / Version 1.0.6

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

ALPHA 5/XS 200 TW Ultrafast Ti:Sa Series

ModBox-FE-125ps-10mJ. Performance Highlights FEATURES APPLICATIONS. Electrical & Optical Pulse Diagrams

Femtosecond pulse generation

Optoelectronic Oscillator Topologies based on Resonant Tunneling Diode Fiber Optic Links

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

MULTI-STAGE YTTERBIUM FIBER-AMPLIFIER SEEDED BY A GAIN-SWITCHED LASER DIODE

High resolution cavity-enhanced absorption spectroscopy with a mode comb.

Supplementary Information for

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

FlexDDS-NG DUAL. Dual-Channel 400 MHz Agile Waveform Generator

Electro-optic Spectral Decoding Measurements at FLASH

Development of Nano Second Pulsed Lasers Using Polarization Maintaining Fibers

UNMATCHED OUTPUT POWER AND TUNING RANGE

CONTROLLABLE WAVELENGTH CHANNELS FOR MULTIWAVELENGTH BRILLOUIN BISMUTH/ERBIUM BAS-ED FIBER LASER

High-frequency tuning of high-powered DFB MOPA system with diffraction limited power up to 1.5W

DISPERSION MEASUREMENT FOR ON-CHIP MICRORESONATOR. A Thesis. Submitted to the Faculty. Purdue University. Steven Chen. In Partial Fulfillment of the

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

Atlantic. Industrial High Power Picosecond Lasers. features

High-power semiconductor lasers for applications requiring GHz linewidth source

Absolute frequency measurement of unstable lasers with optical frequency combs

Low Phase Noise Laser Synthesizer with Simple Configuration Adopting Phase Modulator and Fiber Bragg Gratings

High energy femtosecond OPA pumped by 1030 nm Nd:KGW laser.

The extremely compact laser head is approximately 480 mm long and can

Single Frequency DPSS Lasers

All-Optical Clock Division Using Period-one Oscillation of Optically Injected Semiconductor Laser

Jungwon Kim, Jonathan A. Cox, Jian J. Chen & Franz X. Kärtner. Department of Electrical Engineering and Computer Science and Research Laboratory

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

Lecture 6 Fiber Optical Communication Lecture 6, Slide 1

5kW DIODE-PUMPED TEST AMPLIFIER

Transcription:

taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond laser with a 1 GHz or 10 GHz repetition rate that delivers up to 1.8 W of average power in pulses that can be <15 fs. Tunability is offered between 740 nm and 930 nm. Its innovative design combines a compact hermetically sealed, vibration-resistant laser head that incorporates the Ti:Sapphire oscillator and pump laser, with a full-feature control unit. The control unit houses the field replaceable pump diodes, isolating temperature effects from the taccor itself, and provides intelligent control that monitors laser performance and carries out diagnostics analysis. The result is a highly stable and reproducible product with a long lifetime and low cost of ownership. There are five versions of the taccor: The taccor one offers a selectable (fixed) wavelength; the taccor power and taccor ultra are tuned to produce the highest power or the shortest pulse duration respectively; the taccor tune offers the flexibility of a tunable wavelength using a touch screen or control software and the taccor x10 operating at a 10 times higher repetition rate. Optional features Active locking of repetition rate and pulse timing The TL-1000 is an optional supporting unit that enables tight phase-locking of the repetition rate to an external reference with jitter <100 fs. TL-1000-ASOPS enables a repetition rate offset lock between two GHz oscillators of 2 khz to 20 khz allowing ultrafast time-domain spectroscopy without a mechanical delay stage. Pulse train monitoring An integrated high bandwidth (10 GHz) photodiode can be used for repetition rate monitoring and to supply a signal to the TL-1000 units or external electronics. Repetition rate control Control of the repetition rate and active feedback is enabled by cavity mirrors mounted on a fast and slow piezo crystal enabling rapid feedback and drift control simultaneously; in combination with the TL-1000 unit, this offers precision closed loop stabilisation of the repetition rate. Alternatively, the piezos can be driven by customer supplied electronics. CEPLoQ TM technology CEPLoQ is our patented technology that directly modulates the pump power to maintain phase stabilisation without the use of an AOM. This leads to faster and more stable responses than the traditional method. The taccor is compatible with the Laser Quantum RemoteCom software that allows connection to the Laser Quantum support team for monitoring laser performance and diagnosing opportunities for carrying out laser optimisation. Pump power modulation Modulation access to the pump power with a bandwidth of >100 khz and modulation depth up to ±1% is provided for feedback purposes.

taccor one The taccor one offers a selectable (fixed) wavelength between 740 nm to 920 nm within a compact design and is both self-mode-locking and stable. At 1 GHz repetition rate, the taccor one delivers more than 1.6 W of average power with a pulse duration of <60 fs. 1.0 Spectral Intensity (norm.) 0.8 0.6 0.4 0.2 720 760 800 840 880 920 Stacked spectra indicating the wavelength coverage of the taccor one. Living mouse neuron imaged with the taccor one. taccor power The taccor power is optimised for the highest possible output, offering up to 1.8 W at the Ti:Sapphire gain maximum around 800 nm. Frequency (MHz) 300 305 310 315 320 >45dB f CEO f CEO -45-75 f R - f CEO Intensity (db) 0 200 400 600 800 1000 Frequency (MHz) f R Intensity (db) 3D beam profile from a taccor series laser. taccor x10 RF spectrum showing the f CEO beat, the difference frequency of the repetition rate with the f CEO beat and the repetition rate. The noise floor is given by the spectrum analyser. The zoom in shows the f CEO beat without limitation by the spectrum analyser. The high repetition rate ( 10 GHz ) version of the taccor. Giving up to 1 mw per comb line spaced by 10 GHz, the taccor x10 is unique to the market and opens a wide field of new applications such as resolved mode spectroscopy, low-noise microwave generation, astrocombs or arbitrary waveform generation. Analogue to the other version of the taccor, the taccor x10 can also be configured to allow the control of the repetition rate and gives modulation access for the pump power to enable an easy control of the carrier offset frequency. -10 f rep = 10.226880 GHz RF Power (dbm) 0 2 4 6 8 10 12 Frequency (GHz) f rep = 10.226900 GHz RF spectrum of the signal from the high bandwidth repetition rate measurement photodiode in the taccor (PD option). The noise floor is given by the spectrum analyser. Individually resolved comb modes after passing the taccor x10 beam through a Rb cell. In the lower image, one mode is on resonance with an absorption line.

taccor tune The taccor tune offers the flexibility of a tunable wavelength using a touch screen or control software; a true hands free laser covering the wavelength regime from 740, nm to 930 nm which is unique to the market. 2200 2200 2000 2000 Power (mw) 1800 1600 1400 1200 Power (mw) 1800 1600 1400 1200 1000 1000 720 760 800 840 880 760 800 840 880 920 Power tuning curve for the short wavelength taccor tune (example shown is taccor tune 10). taccor ultra Power tuning curve for the long wavelength taccor tune (example shown is taccor tune 10). The taccor ultra produces the shortest pulse duration within the family. With a 1 GHz repetition rate and delivering 1.6 W of average power, the pulses can be as short as <15. fs. Autocorrelation Intensity (a.u.) 8 6 4 2 0-10 0 10 20 30 Time (fs) RF Power (dbm) -10 0 2 4 6 8 10 12 Frequency (GHz) Autocorrelation trace of taccor ultra indicating emission of pulses with <15 fs duration. Additional capabilities RF spectrum of the signal from the high bandwidth repetition rate measurement photodiode in the taccor (PD option). The noise floor is given by the spectrum analyser. taccor comb The taccor comb consists of an f-to-2f interferometer module, locking electronics from Menlo Systems, and either a taccor power or ultra. The taccor is fully stabilised in repetition rate and carrier-envelope offset frequency; in this configuration, the taccor is a powerful frequency comb engine offering >1 W stabilised comb average power, centred at 800 nm, with pulse durations of <15 fs available for spectroscopy and metrology applications. The 800 nm beam can be used directly or to drive up to two further nonlinear broadening stages to facilitate optical frequency measurements, direct comb spectroscopy, spectrograph calibration, dual-comb linear or non-linear spectroscopy and many other applications. Second harmonic generation Together with A. P. E Angewandte Physik & Elektronik GmbH, Laser Quantum can offer the HarmoniXX second harmonic frequency converter for use with the taccor power. Maintaining the benefits of the 1 GHz repetition rate, it offers up to 250 mw of frequency doubled output. Pre-chirp module Careful control of the group delay dispersion (GDD) of an optical setup is crucial to obtaining the desired results from many applications using femtosecond lasers. Our pre-chirper allows for GDD control from ~0 to -8600 fs 2 enabling the user to easily compensate for the positive GDD of the setup and obtain the right pulse characteristics at the point of use. For full details of these options, please see the dedicated data sheets.

taccor Turn-key GHz femtosecond laser Dimensions (mm) Other information Umbilical length: 2 m Head weight: 15 kgs Cooling system included Warm-up time: 10 minutes 85.5 58.8 510 200 170 Drawings are for illustrative purposes only. Please contact Laser Quantum for complete engineer s drawings. 491 386 Specifications* taccor one taccor power taccor ultra taccor tune taccor x10 Average power output 1 one 4 >700 mw one 6 >900 mw one 8 >1200 mw one 10 >1600 mw power 4 >800 mw power 6 >1000 mw ultra 8 >1200 mw power 8 >1400 mw ultra 10 >1600 mw power 10 >1800 mw tune 8 >1500 mw tune 10 > 1800 mw >1000 mw Center wavelength 740 nm to 920 nm 740 nm to 930 nm (tunable) 3 Pulse duration 4 <60 fs <30 fs <15 fs <80 fs <50 fs Spectral FWHM ~15 nm >23 nm >46 nm ~15 nm >15 nm Repetition rate 5 1 GHz 10 GHz Pulse energy 0.7 nj to 1.6 nj 0.8 nj to 1.8 nj 1.2 nj to 1.6 nj 1.3 nj - 1.8 nj taccor tune 10 1.05 nj - 1.5 nj taccor tune 8 >100 pj Beam size ~0.8 mm +/-0.3 mm ~0.7mm +/-0.3 mm Divergence 2.0 mrad +/-0.5 mrad <10 mrad M-squared <1.6 (tan plane) <1.2 (tan plane) <1.2 (tan plane) <1.2 (sag plane) <1.6 (tan plane) <1.5 (sag plane), <1.5 (tan plane) Power stability 6 +/-1% Noise (RMS) <0.1% RMS Polarisation ratio >100:1 Polarisation direction Horizontal Operating temperature 21 +/- 5 C Applications two photon microscopy, two photon polymerisation, optical precision metrology, ASOPS, optical spectroscopy, ultrafast spectroscopy, frequency comb generation, arbitrary waveform generation, calibration of spectographs (astrometry) * Laser Quantum operates a continuous improvement programme which can result in specifications being improved without notice. 1 For the taccor one and taccor tune, the values stated are ~800 nm and will vary across the wavelength range. 2 Select at time of order, fixed with accuracy ±3 nm, higher accuracy available on request. 3 Choose between blue (740 880 nm) and red (780 930 nm) tuning range upon order. 4 Achieved with optional extra cavity dispersion compensation. 5 Repetition rate: accuracy ±10 MHz and for the taccor x10 accuracy ±25 MHz, higher accuracy available on request. 6 Measured over a 8 hours after cold start within operating temperature range. LASER QUANTUM LTD tel: +44 (0) 161 975 5300 web: www.laserquantum.com LASER QUANTUM INC tel: +1 408 510 0079 web: www.laserquantum.com LASER QUANTUM GmbH tel: +49 7531 368371 web: www.laserquantum.com VA1.5