VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Similar documents
VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Moeller Electric Corporation

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Three-phase monitoring relays CM-PFE and CM-PFE.2

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Control module CP-A CM

Type CP-S, CP-C & CP-A Switch mode

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Control module CP-A CM

Three-phase monitoring relay

Three-phase monitoring relays

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PFS

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-TGD.22

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-SDD.22

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

27/04/2015

Zelio Control Measurement Relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Three-phase monitoring relay CM-PVE

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relay

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.


Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDS.22

CP-T range Product group picture

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

05/09/2012

Thermistor motor protection relays

Three-phase monitoring relay CM-PBE

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

CP-T range Benefits and advantages

38 Series - Relay interface modules A. Features /

Protection and safety SQZ3 phase and sequence relay

CP-E range Benefits and advantages

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

48 Series - Relay interface modules A. Features

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Liquid level monitors and controls

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic relays. Monitoring. Monitoring

02/11/2015

Frequency- and voltage monitoring. Technical data G4PF21-1

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Thermistor motor protection relays

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Liquid level monitoring relay CM-ENS.2x

Power supply CP-D 24/4.2 Primary switch mode power supply

Subject to changes 11/2003 Page 1/7

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Type Nominal voltage (V) Code HSV V

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Primary switch mode power supplies Product group picture

38 Series - Relay Interface Modules A

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

Power supply CP-E 24/0.75

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Transformers, Power Supply Units and Socket Outlets

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Transcription:

Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage LED R: Relay status TECHNICAL DATA SUPPLY CIRCUIT (=MEASURING CIRCUIT) Terminals Supply voltage -- 208/120 480/277 V AC Supply voltage tolerance -10 / +10 % Rated frequency Rated frequency tolerance 50 / 60 Hz 48 63 Hz Rated consumption 3 x 480 V AC typ. 0,55 W / 0,85 VA Duty-cycle 100 % Backup power time Recovery time Drop-out voltage < 10 ms > 500 ms 121/70 V AC MEASURING CIRCUIT Terminals Measurand Measuring method Monitoring functions Measuring range Frequency Input resistance Overload capacity -- voltage 3-phase rectified value phase sequence, phase loss, asymmetry see supply voltage see rated frequency 3 MOhm see supply voltage tolerance http://tele-online.com Page 1 of 7

MEASURING CIRCUIT Thresholds Max - Min - Asymmetry fixed, 30% Hysteresis - TIMING CIRCUIT Start-up delay fixed approx. 400 ms Tripping delay < 250 ms STATUS INDICATION Supply voltage LED U (green) on supply voltage applied Relay status LED R (yellow) on output relay energized OUTPUT CIRCUIT Terminals 11-12-14 Kind of output Number of contacts Contact material Rated voltage Maximum switching voltage Minimum switching voltage / switching current Rated current (IEC 60947-5-1) change-over contact AC-1 AC-15 DC-12 DC-13 Relay 1 AgNi 250V 400V AC 12 V / 10 ma 8 A / 250 V 1,5 A / 240 V (B300) 8 A / 24 V 0,1 A / 250 V Endurance mechanical 30 x 10 6 switching cycles electrical (AC-1) 100 x 10 3 switching cycles Rated frequency of operation with load 6/min without load 1200/min Fuse rating 8 A fast acting ACCURACY Base accuracy Setting accuracy < 5 % (of full scale) < 5 % (of full scale) Repeat accuracy < 1 % Temperature influence < 0,05 % / C http://tele-online.com Page 2 of 7

ACCURACY Voltage influence - Frequency influence - ENVIRONMENTAL CONDITIONS Ambient temperature operation -25 +60 C storage -40 +70 C Relative humidity 5 95 % Vibration EN 60947-1 2 13,2 Hz: 1 mm; 13,2 100 Hz: 7 m/s 2 Shock EN 60947-1 150 m/s 2 11 ms GENERAL DATA Dimensions W H D 22,5 x 67 x 76 mm Mounting Mounting position DIN rail (EN60715) any Housing material PA 66, self-extinguishing plastic, class V-0 Degree of protection housing IP40 terminals IP20 Electrical connection Wire size Stripping length Tightening torque flexible with wire end ferrule flexible without wire end ferrule rigid Screw terminal 0,5 2,5 mm² (20 AWG 13 AWG) 0,5 4 mm² (20 AWG 12 AWG) 0,5 4 mm² (20 AWG 12 AWG) 8 mm max. 1Nm MTTF - Weight 82 g ISOLATION DATA Pollution degree (IEC 60947-5-1) Overvoltage category (IEC 60947-5-1) Rated insulation voltage Rated impulse withstanding voltage Insulation test voltage supply circuit / supply circuit / supply circuit / 2 III 300 V 6 kv 3780 V Degree of protection supply circuit / protective separation http://tele-online.com Page 3 of 7

STANDARDS Product standard IEC 60947-5-1 Interference immunity IEC 61000-6-2 Interference emmision IEC 61000-6-4 Approvals http://tele-online.com Page 4 of 7

FUNCTIONS When all the phases are connected in the correct sequence and the measured asymmetry is less than the fixed value, the output relay R switches into on-position. Phase sequence monitoring When the phase sequence changes, the output relay R switches into off-position. LED U R Phase failure monitoring When one of the three phases fails, the output relay R switches into off-position. LED U R Asymmetry monitoring When the asymmetry exceeds the fixed ASYM-value, the output relay R switches into off-position. Reverse voltages of a consumer (e.g. a motor which continues to run on two phases only) do not effect the disconnection. LED U R http://tele-online.com Page 5 of 7

CONNECTIONS 12 14 11 12 14 11 http://tele-online.com Page 6 of 7

DIMENSIONS 67 mm 76 mm 22,5 mm CONTACT TELE Haase Steuergeräte Ges.m.b.H. Vorarlberger Allee 38 1230 Vienna Austria CALL US +43 / 1 / 614 74-0 ONLINE SUPPORT info@tele-online.com http://tele-online.com Page 7 of 7