3933 US Route 11 Cortland, NY 13 Telephone: (7) 3-6711 Facsimile: (7) 8-39 www.intertek.com July 24, 215 Nexans Cabling Solutions Alsembergsesteenweg 2, b3 B-151 Buizingen BELGIUM Test report number 12193693CRT-1b Project number 12193693-311 TEST: 3179412CRT-1b Electrical performance testing of a cabling configuration to the standard requirements of ISO/IEC 111 for Class E A permanent link. STANDARD USED: ISO/IEC 111 Information Technology - Generic cabling for customer premises, Edition 2.2, dated June 211. SECTIONS USED: Annex A, Balanced permanent link and CP link performance of ISO/IEC 111 AUTHORIZATION: The project was authorized by Ms. Nancy Declerck, representing the client, Nexans Cabling Solutions, with signed quotation number 525. SAMPLE DESCRIPTION: The client supplied a 3-connector permanent link as illustrated below. The samples were received on July 1, 215 and were production samples in undamaged condition. Component Id Manufacturer Description Part number 1, 3 Nexans LANmark-6A Evo Snap-In N42.66A Connector Cat 6A Screened 2 Nexans LANmark-7A S/FTP 23 AWG Cat 7A N1.372 LSZH 4 Nexans LANmark-7A Patch Cord GG 8C N11.23AOO Cat 7A Screened LSZH 5 Nexans LANmark-6A Evo Snap-In Connector Cat 6A Screened Stranded Wire N42.67A Page 1 of 2 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc.
Test report number 12193693CRT-1b July 24, 215 EQUIPMENT LIST: The following equipment was employed in conducting the tests. Equipment used Model number Control number Calibration date Calibration due date Fluke Networks Cable Analyzer DTX-1 N1134 12/31/214 12/31/215 Keysight Network Analyzer 83E E366R 3/2/215 3/17/216 Temperature humidity meter OM-EL-USB-2-LCD H243 1/22/215 1/22/216 DATE OF TEST: July 6, 215 through July 21, 215 TEST REPORT REVISION HISTORY: First Issue: July 24, 215 Original document RESULTS: See appendixes A and B for the test results. CONCLUSION: The 3-connector permanent link, as previously described and supplied by the client, was tested in accordance with the standard referred to on page 1, and did comply with the indicated applicable transmission requirements. The PSANEXT and PSAACRF requirements are met, based on the coupling attenuation margin specified in clause A.2.11.1 of ISO/IEC 111. The testing was performed at Intertek located in Cortland, New York. The procedures and requirements were taken from the standard referred to on page 1. Reviewed and Approved By: Antoine Pelletier Project Engineer Global Cabling Products Testing John Cash Associate Engineer Global Cabling Products Testing Page 2 of 2 Intertek Testing Services NA, Inc.
Test report number 12193693CRT-1b July 24, 215 Appendix A Test results This appendix contains 1 page. Intertek Testing Services NA, Inc.
Cable ID: 12193693CRT-1B Test Summary: Date / Time: 7/6/215 7:4:13 AM Operator: Your Name Model: DTX-1 Headroom 4.6 (NEXT 36-) Software Version: 2.77 Main S/N: 93159 Test Limit: ISO111 PL3 Class Ea Limits Version: 1.9 Remote S/N: 931 Cable Type: Cat 7A S/FTP NVP: 76. Main Adapter: DTX-PLA2 Calibration Date: 12/31/214 Remote Adapter: DTX-PLA2 Length (ft) [Pair 12] 269 Prop. Delay (ns), Limit 498 [Pair 36] 367 Delay Skew (ns), Limit 44 [Pair 36] 7 Resistance (ohms), Limit 21. [Pair 12] 12.8 Insertion Loss Margin () [Pair 36] 2.3 Frequency () [Pair 36] 5. Limit () [Pair 36] 42.1 Worst Case Margin Worst Case Value MAIN SR MAIN SR Worst Pair 12-36 36-12-36 36- NEXT () 8.6 4.6 8.6 5.2 Freq. () 489. 318. 489. 473. Limit () 28.2 33.3 28.2 28.6 Worst Pair 36 36 36 36 PS NEXT () 8.1 4.5 8.1 6.2 Freq. () 488. 319. 489. 499. Limit ().2 3.6.1 24.9 MAIN SR MAIN SR Worst Pair -36-36 -36-36 ACR-F () 5.7 7.4 6.1 7.9 Freq. () 39. 9. 477. 484. Limit () 12.4 12. 1.6 1.5 Worst Pair 36 36 PS ACR-F () 6.8 8.5 8. 8.9 Freq. () 39. 39. 477. 477. Limit () 9.4 9.4 7.6 7.6 MAIN SR MAIN SR Worst Pair 12-36 36-12-36 12-36 ACR-N () 1.8 8.3 1.8 8.8 Freq. () 489. 318. 489. 5. Limit () -13.4.4-13.4-14.2 Worst Pair 36 36 36 36 PS ACR-N () 1.2 6.8 1.2 8.6 Freq. () 489. 319. 489. 499. Limit () -16.4-2.3-16.4-17.2 MAIN SR MAIN SR Worst Pair 78 12 36 RL () 4.5 3.1 5.6 7.2 Freq. () 3.1 3.3 49. 497. Limit () 21. 21. 8. 8. Compliant Network Standards: 1BASE-T 1BASE-TX 1BASE-T4 1BASE-T 1GBASE-T ATM- ATM-51 ATM-1 1VG-AnyLan TR-4 TR-16 Active TR-16 Passive 1 Wire Map (T568B) 2 NEXT () 1 2 ACR-F () ACR-N () - 5 3 2 1 RL () 269 ft 5 3 2 1 Insertion Loss () 1 2 NEXT @ Remote () 1 2 ACR-F @ Remote () ACR-N @ Remote () - 1 2 RL @ Remote () LinkWare PC Version 9.3 Project: DEFAULT Untitled1 Site: Client Name
Test report number 12193693CRT-1b July 24, 215 Appendix B Test results for coupling attenuation This appendix contains 3 pages. Intertek Testing Services NA, Inc.
ISO/IEC 111, Class Ea Link 12193693CRT-1b Appendix B Coupling Attenuation, Wall outlet jack, Near-End 9 7 5 3 1 2 3 5 7 9 1 Frequency () Margin () 2.51 22.88 12.7 21.9 Freq. () 342 5 341 389 9 7 5 3 Coupling Attenuation, Wall outlet jack, Far-End 1 2 3 5 7 9 1 Margin () 19.27 22.43 16.44 22.29 Freq. () 248 371 177 9 Frequency () Page 1 of 3
ISO/IEC 111, Class Ea Link 12193693CRT-1b Appendix B Coupling Attenuation, Telecom room side, Near-End 9 7 5 3 1 2 3 5 7 9 1 Margin () 18.7 21.59 14.3 23.5 Freq. () 341 394 343 367 Frequency () Coupling Attenuation, Telecom room side, Far-End 9 7 5 3 1 2 3 5 7 9 1 Margin () 14.28 14.17 1.96 16.96 Freq. () 247 388 37 366 Frequency () Page 2 of 3
ISO/IEC 111, Class Ea Link 12193693CRT-1a Appendix B Coupling Attenuation, Consolidation point jack, Near-End 9 7 5 3 1 2 3 5 7 9 1 Frequency () Margin () 17.7 18.47 12.17 13.86 Freq. () 489 23 3 443 Coupling Attenuation, Consolidation point jack, Far-End 9 7 5 3 1 2 3 5 7 9 1 Frequency () Margin () 17.34 17.89 14. 17. Freq. () 248 411 37 412 Page 3 of 3