Micro MV P2DAAA. Custody transfer accuracy Built-in multivariable 3-in-1 transmitter. Daily. Zigbee wireless radio. Extended length battery backup

Similar documents
The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

PAD - Heavy Duty Differential Pressure Trasmitter

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

E-Chart Image Release History

Model Sono-Trak Transit Time

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Series Smart Pressure Transmitter

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol

Field Devices and Wiring

11A Series Absolute Pressure Transmitters

The Rosemount 848T Wireless Temperature Transmitter

Rosemount 3095FT MultiVariable Flowmeter

ABB conductivity analyzer and probe package

Mass Flow Transmitter THE PROVEN LEADER IN MULTIVARIABLE MASS FLOW MEASUREMENT.

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

and ClearSCADA s custom EFM object the SOLARPack 410 becomes a complete electronic flow measurement system. Chart Recorder Replacement

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

A New Generation of Pressure Transmitters

Mass and Volume Flow Transmitter

VELTRON II Microprocessor Based Pressure & Flow Smart

914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

SMART TEMPERATURE TRANSMITTERS. smar

Compact Orifice Flow Meter

LOW POWER FLOW COMPUTERS Greg Phillips Bristol Babcock Inc Governors Circle West, Suite F, Houston, TX 77092

A New Generation of Pressure Transmitters

RUNYI GROUP AJ FLOW TOTALIZER. Features

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Smart Pressure Transmitter

Accutech DP20. Wireless differential pressure field unit

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

FOSTEN AUTOMATION SÉRIE F500-RD

mass flowmeter for compressed air

SECTION BUILDING METERING (Indianapolis Campus Only)

Magnetic Flowmeter Systems

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement

Using the AcuDew Moisture Transmitter

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Non-Submersible Industrial Pressure Transducer

General Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Series 1000 and 2000 Transmitters with MVD TM Technology

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

RCM DIRECT READING FLOWMETER

AccuSolar SOLAR POWERED SYSTEM

FIELD DEVICES PRESSURE

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

WATERFLUX 3070 Technical Datasheet

FIELD DEVICES - PRESSURE

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

SonoMeter 31 Energy Meters

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

E l e c t r o m a g n e t i c f l o w m e t e r s

FICHA TÉCNICA DE PRODUTO

Improve asset protection and utilization

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

Ambient Conditions. Operating Conditions. Pressure

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Rosemount 3101, 3102, and 3105

IP26 Series Current to Pneumatic Converter

Pressure Transmitter SIL

OPTIMASS 1000 Technical Datasheet

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Mass Flow and Density Transmitter with FOUNDATION fieldbus

Kotron Sentinel Model 804 RF Level Transmitter

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

LST100 Ultrasonic level transmitter for upstream oil and gas

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

UTM10 Series Ultrasonic Transit-time Flowmeters

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

OPTIFLUX 5000 Technical Datasheet

ph or ORP Transmitter

Positioner with HART Communication Type 3780

General Specifications

OPTIFLUX 5000 Technical Datasheet

Pressure transmitter For general industrial applications Model A-10

University of Rochester Design Standard August 13, 2014

FCX. Series AII & AIIe Electronic Transmitters. Barton

General Specifications

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

General Specifications

Accessories for EST4 Series

Electro-Magnetic Flowmeters COPA-XE

Level Lance Model 5100

Preface WBPEEUI110504A0

Infocal 9 Energy calculator

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Field IT 2600T Series Pressure Transmitters

Transcription:

The Micro MV P2DAAA is a four meter bi-directional field mounted flow computer with a built in Rosemount 205 Multivariable Transmitter (DP, P, and TEMP) which can be used for all liquid and gas applications, including custody or noncustody measurements. The Micro MV P2DAAA flow computer is the most powerful flow computer of its kind and represents one of the latest advancements in operation, performance, and modularity. The Micro MV P2DAAA has been designed to meet the requirements of a wide variety of specialized industries using a single hardware platform thus reducing spare parts requirements, training and calibration costs, and lowers the overall cost of ownership. With over 5,000 units in worldwide operation, the Micro MV P2DAAA is indicative of Dynamic Flow Computers intense commitment to our customer s needs and expectations. The Micro MV P2DAAA flow computer can be found operating under the most extreme conditions: the hot Saudi Arabian desert, the humid forests of Colombia, the snowcovered valleys of Canada, and the corrosive salt air of offshore platforms. You can be assured that the Micro MV will be reliable under the rigors of any environmental conditions that you can imagine. All the standards of measurement for liquids or gas (API, AGA, ISO, NIST, etc.) are available in the Micro MV P2DAAA. We also include special equations at the request of our clients. Here are just a few of the ways we have you covered: Features Ultra low power (0.5 watts) 32-bit processor Touch screen interface Turbine diagnostics Battery backup/ups Multiple I/O options Wireless Radio/Modem ready Gas chromatograph interface Custody transfer accuracy Built-in multivariable 3-in-1 transmitter Communications RS232 Modbus RS485 Modbus Analog and digital I/O Zigbee wireless radio FreeWave wireless radio DNP3 Bluetooth Applications Liquid and gas measurement Wellhead measurement & automation Custody measurement and control Compressor stations Well optimization PID control Liquid and gas pipelines Injection index testing Reports/Storage Daily Hourly Monthly Monthly day by day Calibration and audit Alternative Power Extended length battery backup Solar powered

The Micro MV P2DAAA flow computer has the capacity to handle up to FOUR bi-directional gas or liquid measurement trains. Multiple equations are included among which are AGA3/API14.3, API5.7, API2540, AGA7, AGA9, with more being added continuously. The Micro MV P2DAAA accepts any type of primary element: Venturi, Annubar, Turbine, PD, Ultrasonic, V-Cone, Wedge, Vortex, etc. Additionally, it can carry out density calculations according to the following standards: 5A,B; 6A,B,C; 23A,B,C; 24A,B,C; 53A,B; 54A,B,C; 23 and 24; API12, AGA8, NBS1048 for hydrogenate and oxygenate, NBS for steam, NBS1045 for ethylene, saturated and supersaturated steam, etc. Contact our offices or visit our website for available equation updates. The Micro MV P2DAAA includes a factory integrated multivariable 3-in-1 digital transmitter manufactured by Rosemount for the measurement of temperature, pressure, and differential pressure. Another exceptional characteristic of the Micro MV P2DAAA is its ability to communicate directly with a gas chromatograph via MODBUS or proprietary protocol for highly precise flow measurements. It can also control pneumatic or electrical valves (on-off or variable by means of analog outputs or process PID control). The display screen of the Micro MV P2DAAA is four lines of twenty characters each. Process parameter values that are displayed on the screen are user-selectable and are alternately displayed, up to three at a time, at user-defined intervals. The front of the Micro MV P2DAAA includes four non-intrusive touch keys for configuration and operation of the flow computer. This design avoids violation of the area classification by allowing the user to interact with the flow computer without having to remove the cover. The input/output assignment, flow equations, historical data storage, and other functions are carried out using Dynamic Flow Computers DYNACOM software. This software is Windows based, free of charge, and available for download/update at any time on our website. DYNACOM Software Capabilities: Flow computer diagnostics Configure inputs and outputs Configure PID control Personalize report time and content Configure and select the local LCD screen displayed parameters Reassign and customize MODBUS registers and values Create and implement custom math and formulas Input and output calibration Automatic and periodic downloading of flow computer reports Obtain historic data for display, saving, exportation, or printing Historic data is available in the memory of the flow computer for download or display. Maximum Report Storage: Hourly reports: 1536 hours* Daily reports: 64 * Daily reports, hour by hour: 64* Monthly reports: 6* Monthly, day by day: 2 months* Calibration reports: 20* Audit reports: 100* Alarm reports: 100* Special reports: HTML, and others *The number of reports stored can vary according to application.

Multivariable Transmitter The Multivariable Sensor is a 3-in-1 model 205 transmitter manufactured by Rosemount Inc. for Dynamic Flow Computers. This sensor measures static/ absolute pressure, differential pressure, and using an optional RTD, process temperature. These three process variables are available all the time and updates are sent to the flow computer up to NINE times per second. The model 205 is a culmination of the vast technological experience that Rosemount Inc. has in the multivariable field. It includes the well recognized and tested 3051C technology using capacitive cells for differential pressure as well as a patented piezoresistive/silicon sensors for measurement of absolute/ static pressures. The digital technology utilized in the production of the 205 module is the most advanced measurement technology on the market, assuring maximum accuracy and rangeability. The extensive use of patented technology concerning the sensors internal circuitry significantly reduces the size and the weight of the 205 sensor. The Multivariable Sensor measures three process variables at one time. It incorporates a capacitive differential pressure sensor, a piezoresistive absolute/static pressure sensor, and an optional connection for a two, three, or four wire RTD. The sensors convert the process variables to a digital format for direct communication with the flow computer. Electrical/Conduit Connections Process Connection Housing (Flow Computer) RTD Connection Multivariable Display PHYSICAL SPECIFICATIONS Two 3/4" NPT. Two ¼' -18 NPT (multivariable) Material: copper free aluminum Painting: epoxy or polyurethane. Classification: NEMA 4X class 1 div. 1 IP66 To flow computer terminal block or directly to multivariable 3-in-1 (pressure, differential pressure, and temperature), manufactured by Rosemount Inc. Plasma; 4 lines x 20 characters each line. With back light; four non-intrusive keys for configuration, operation, and calibration Certifications CSA for class 1, div. 1, groups B, C and D UL for class I, zone 1, AEx d IIB+H2 Temperature Limits Operation: -40 to 185 F (-40 to 85 C) Storage: -50 to 190 F (-46 to 87 C) Humidity 100%

Voltage Power Consumption Solar Board (Optional) UPS (Optional) Polarity Processor Memory Extended Memory (Optional) Real Time Clock Internal Battery Optic Isolation Analog Input Pulse/Frequency Input Digital/Switch Input RTD Input ELECTRICAL SPECIFICATIONS 7 to 28 VDC 0.5 watt 10/20 watts, 12 volts 2 day operation Reverse polarity protected 32 bits @ 16.7Mhz 2 MB, 35 day storage 128 MB virtual hard disk Years/Months/Days/Hours/Minutes Lithium ion INPUT SPECIFICATIONS Each input is optically isolated with ±250 VDC chassis isolation Four 4-20mA (or 0-5V) inputs (expandable to 9 inputs) Resolution 24 bits Three inputs Square wave frequency range 0-6000 HZ Sine wave frequency range 0 1200 HZ Signal must be > 40 mv for sine wave Signal must be > 3 volts for square wave Input 3 is for square wave only Four inputs (4 mutual contacts software selectable to be input or output see Digital Output*) 7-28Vdc 0.25 Amp rating Direct connection to multivariable Direct connection to flow computer (Direct connection to flow computer uses two of the analog input channels) 24 bit resolution OUTPUT SPECIFICATIONS Optic Isolation Each output is optically isolated with ±250 VDC chassis/ground isolation Digital/Switch/Pulse Output Four outputs (4 mutual contacts software selectable to be input or output see Digital Input*) 7-28Vdc 0.25 Amp rating. On/Off or pulses (to 125 pulses/sec.) Analog Output One output (expandable to 4) 4-20mA (external power required) For PID control or for data transmission Resolution 16 bits COMMUNICATION SPECIFICATIONS RS485 Quantity 2 @ 1200 19200 bps RS232 Quantity 1 @ 1200 19200 bps Printer Port Quantity 1 Protocol MODBUS RTU/ASCII, DPN3 Optional Modem, Radio, Ethernet, Bluetooth

Monitor/Alarm Number of Trains Flow Calculation Primary Elements Engineering Units Base Conditions Equations DIAGNOSTIC SPECIFICATIONS Multivariable: P, DP, T Analog inputs/outputs Digital/switch Inputs Digital/switch outputs Pulse/frequency inputs Internal temperature Battery voltage Internal power supply FLOW COMPUTATION SPECIFICATIONS Four bi-directional (dependent on application) Simultaneous gas and liquid Differential: Orifice, V-Cone, Wedge, Annubar, Venturi, etc. Pulse/Frequency: Turbine, PD, Vortex, Ultrasonic, etc. US and Metric 60 F, 14.7 Psia (15 C and 1 Kg. /Cm²) 68 F, 14.7 Psia (20 C and 1 Kg/Cm²) AGA3, API14.3, AGA7, AGA9, API5.6, API5.7, AGA8 methods 1, 2, and detailed; API 2540; API11-2-1, 11-2-1M; 11-2,2, 11-2-2M; GPA15, 16; API2565; tables 5A,B; 6A,B,C; 23A,B,C; 24A,B,C; 53A,B; 54A,B,C; 23 and 24. Others added continuously Consult factory for complete list Function Differential Sensor Limits Absolute Sensor Limits Gage Sensor Limits Temperature Sensor (does not consider error from external RTD) Temperature Limits (applies to Multivariable Flange temperature. Does not apply to process temperature) Environmental Temperature Limits Storage Temperature Limits Humidity MULTIVARIABLE SPECIFICATIONS Gas, oil, water, steam, and others Range 2: -250 to 250 in H2O (-0.622 to 0.622 bar) Range 3: -1000 to 1000 in H2O (-2.49 to 2.49 bar) Range 3: 0.5 to 800 psia (3447 to 5516 kpa) Range 4: 0.5 to 3626 psia (3447 to 25000 kpa) Range C: 0 to 800 psig (0 to 5516 kpa) Range D: 0 to 3626 psig (0 to 25000 kpa) Compatible with any 100 Ohm Platinum RTD Range 3: -300 to 1200 F (-184 to 649 C) accuracy ±1.0 F (±0.56 C) Range 4: 1200 to 1500 F (649 to 816 C) accuracy ±0.5 F by each 50 F -40 to 250 F (-40 to 121 C) (Silicon fill) 0 to 185 F (-17.8 to 85 C) (Inert fill) -40 to 185 F (-40 to 85 C) (Silicon fill) 0 to 185 F (-17.8 to 85 C) (Inert fill) -40 to 230 F (-40 to 110 C) 0 100% relative humidity

MULTIVARIABLE ACCURACY (Includes the combined effects of linearity, hysteresis, and repeatability) Differential Pressure ± 0.075% of the span for spans from 1:1 to 10:1 of the URL. For spans smaller than 10:1 calculate according to: Accuracy = ±[0.025 + 0.005 (URL/Span)]% of span Pressure absolute/static ± 0.075% of the span for spans from 1:1 to 10:1 of the URL. For spans smaller than 10:1, calculate according to: Accuracy = ±[0.03 + 0.0075 (URL/Span)]% of span Temperature Accuracy ±1.0 F (±0.56 C) from -300 to 1200 F (-184 to 649 C) Process Connections Wetted Parts Non-Wetted Parts MULTIVARIABLE CONSTRUCTION MATERIAL Transmitter 2 Coplanar ¼ 18 NPT on 2⅛ centers ½ 14 NPT on 2, 2⅛, or 2¼-in. centers with optional flange adapters RTD RTD dependent. Isolating Diaphragms 316L SST or Hastelloy C-276 Drain Vents / Valves 316 SST or Hastelloy C-276 Flanges Plated carbon steel, 316 SST, or Hastelloy C-276 Wetted O-Rings Glass-Filled PTFE Screws Plated carbon steel per ASTM A449, Grade 5 or austenitic 316 SST Fill Fluid Silicone

Optional Accessories Analog Output Expansion Analog Input Expansion RS-232 Elbow SmartCone Armored RTD Cable Shielded RTD Cable Solar Panel 5-Valve Manifold L-Shaped Mounting Bracket Back-Up Battery