Three-phase monitoring relays CM-PFE and CM-PFE.2

Similar documents
Three-phase monitoring relay CM-PVE

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFS

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relay CM-PBE

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Three-phase monitoring relay

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Liquid level monitoring relay CM-ENS.2x

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-SDS.22

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-SDD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-TGD.22

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Three-phase monitoring relay

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Power supply CP-D 12/2.1

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-T 48/5.0 Primary switch mode power supply

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CP-E range Benefits and advantages

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

CP-T range Product group picture

Power supply CP-T 24/40.0 Primary switch mode power supply

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Primary switch mode power supplies Product group picture

CP-T range Benefits and advantages

Pluggable interface relays CR-U Universal relays

Thermistor motor protection relays

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-E 24/0.75

Control module CP-A CM

Power supply CP-D 24/1.3

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Control module CP-A CM

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Thermistor motor protection relays

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-SDE

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Subject to changes 11/2003 Page 1/7

Liquid level monitors and controls

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Analog signal converters CC range

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Analog signal converters CC-E I/I

Transcription:

Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 006 S0015 Characteristics Monitoring of three-phase mains for phase sequence and phase failure Powered by the measuring circuit 1 c/o (SPDT) contact 22.5 mm (0.89 in) width 1 LED for the indication of operational states Various certifications and approvals (see overview, document no. 2CDC112246D0201) Order data Three-phase monitoring relay Type Rated control supply voltage = measuring voltage Order code CM-PFE 3 x 208-440 V AC 1SVR550824R9100 CM-PFE.2 3 x 200-500 V AC 1SVR550826R9100

Functions Operating controls 1 Indication of operational states R: yellow LED Relay status 1 2CDC 251 006 S0015 Application / Operating mode The CM-PFE is designed for use in three-phase mains for monitoring the phase parameters phase sequence and phase failure. It works according to the closed-circuit principle. 2 - Three-phase monitoring relay CM-PFE.2 Data sheet

Function descriptions / diagrams Phase sequence and phase failure monitoring If all phases are present with the correct phase sequence, the output relay energizes after the fixed start-up delay t s is complete. If a phase failure or a phase sequence error occurs, the fixed tripping delay t v starts. When timing is complete, the output relay de-energizes. The LED R glows when the output relay is energized. In case of motors which continue running with only two phases, the CM-PFE detects phase failure if the reverse fed voltage is less than 60 % of the originally applied voltage. L1, L2, L3 Measuring value 11-14 11-12 R: yellow LED L1, L2, L3 L1, L3, L2 L1, L2, L3 L1, L2 L1, L2, L3 L3 t s t v t s t v t s t s = Start-up delay fixed 500 ms t v = Tripping delay fixed 500 ms 2CDC 252 061 F0208 2CDC 252 061 F0208 Electrical connection L1, L2, L3 Control supply voltage = measuring voltage L1 L2 L3 11-12/14 Output contact - closed-circuit principle L1 L2 L3 11 12 11 12 14 14 1SVC 110 000 F0117 Connection diagram CM-PFE Data sheet Three-phase monitoring relay CM-PFE.2-3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Type CM-PFE CM-PFE.2 Supply circuit = measuring circuit L1, L2, L3 Rated control supply voltage U s = measuring voltage 3 x 208-440 V AC 3 x 200-500 V AC Rated control supply voltage U s tolerance -15...+10 % Rated frequency 50/60 Hz Frequency range 45-65 Hz Typical current / power consumption 400 V AC 13 ma / 9 VA Measuring circuit L1, L2, L3 Monitoring functions Phase failure J Phase sequence J Measuring ranges 3 x 208-440 V AC 3 x 200-500 V AC Thresholds U min 0.6 x U N Hysteresis related to the threshold value - Response time 500 ms Timing circuit Start-up delay t s Tripping delay t v fixed 500 ms fixed 500 ms User interface Indication of operational states Relay status R: yellow LED V output relay energized Output circuits Kind of output 11-12/14 relay, 1 c/o (SPDT) contact Operating principle closed-circuit principle 1) Contact material Rated operational voltage U e Minimum switching voltage / Minimum switching current Maximum switching voltage / Maximum switching current AgNi alloy, Cd free 250 V Rated operational voltage U e and AC-12 (resistive) at 230 V 4 A rated operational current I e AC-15 (inductive) at 230 V 3 A AC rating (UL 508) Mechanical lifetime DC-12 (resistive) at 24 V DC-13 (inductive) at 24 V Utilization category (Control Circuit Rating Code) max. rated operational voltage max. continuous thermal current at B 300 max. making/breaking apparent power at B 300 24 V / 10 ma see "Load limit curves" 4 A 2 A B 300 pilot duty; general purpose 250 V, 4 A, cos phi 0.75 300 V AC 5 A 3600/360 VA 30 x 10 6 switching cycles Electrical lifetime AC-12, 230 V, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve short-circuit protection Conventional thermal current I th n/c contact n/o contact 6 A fast-acting 10 A fast-acting 1) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. 4 A 4 - Three-phase monitoring relay CM-PFE.2 Data sheet

General data MTBF on request Duty cycle 100 % Dimensions see "Dimensional drawings" Weight net 0.067 kg (0.147 lb) Mounting DIN rail (IEC/EN 60715), snap-on mounting without any tool Mounting position any Minimum distance to other units vertical / horizontal 10 mm (0.394 in) if ambient temperature > 50 C and rated operational currents > 2 A Degree of protection housing IP50 terminals IP20 Electrical connection Connecting capacity fine strand with wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Stripping length Tightening torque Recommended screw driver fine strand without wire end ferrule rigid 2 x 1-1.5 mm 2 (2 x 18-16 AWG) 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) 10 mm (0.39 in) 0.6-0.8 Nm (7.08 lb.in) PZ 1 / Ø 4.5 mm Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C transport -40...+85 C Climatic class 3K3 Damp heat, cyclic IEC/EN 60068-2-30 6 x 24 h cycle, 55 C, 95 % RH Vibration, sinusoidal Class 2 Shock Class 2 Isolation data Rated insulation voltage U input circuit / output circuit 600 V Rated impulse withstand voltage U imp input circuit / output circuit 6 kv Pollution degree 3 Overvoltage category III Standards / Directives Standards IEC/EN 60255-27, IEC/EN 60947-5-1, EN 50178 Low Voltage Directive EMC Directive RoHS Directive 2014/35/EU 2014/30/EU 2011/65/EU Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 kv / 8 kv) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 V/m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 kv / 5 khz) surge IEC/EN 61000-4-5 Level 4 (2 kv L-L) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 V) radio-frequency fields Interference emission EN 61000-6-3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B Data sheet Three-phase monitoring relay CM-PFE.2-5

Technical diagrams Load limit curves V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 194 F0205 V V 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 Switching cycles 250 V resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Derating factor F for inductive AC load 2CDC 252 192 F0205 Switching current [A] 2CDC 252 148 F0206 Contact lifetime 6 - Three-phase monitoring relay CM-PFE.2 Data sheet

Dimensions in mm and inches 88.5 3.48 81 3.19 22.5 0.886 78 3.07 78.5 3.09 2CDC 252 189 F0005 Further documentation Document title Document type Document number Electronic relays and controls Catalog 2CDC 110 004 C02xx You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Measuring and monitoring relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. Data sheet Three-phase monitoring relay CM-PFE.2-7

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 112 231 D0201 (12.2017) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2017 ABB All rights reserved