Modular Fourier Transform Infra-Red Spectrometer (FT-IR) Solution

Similar documents
Cornerstone 130 1/8 m Monochromators

Cornerstone 260 1/4 m Monochromators

TracQ. Basic Data Acquisition and Spectroscopy Software

Spotlight 150 and 200 FT-IR Microscopy Systems

Development and Applications of a Sample Compartment FTIR Microscope

Spectrum GX systems FT-IR SPECTROSCOPY.

1/8 m GRATING MONOCHROMATOR

Compact Photonics Control Solutions

Oriel MS260i TM 1/4 m Imaging Spectrograph

Electro-Optic Modulators

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Guide to Operating the Bruker FT-IR Microscope I. Basic Spectrum Acquisition with Vertex 70

The FTNIR Myths... Misinformation or Truth

Tunable KiloArc. Tunable Broadband Light Source.

F o r M o t i o n, T h i n k N e w p o r t

Compact High Intensity Light Source

SpectraPro 2150 Monochromators and Spectrographs

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

PHONE: +1 (519) FAX: +1 (519)

MS260i 1/4 M IMAGING SPECTROGRAPHS

Oriel Sol3A Class AAA Solar Simulators

Oriel Cornerstone 130 1/8 m Monochromator

Quick Start MMRC Nicolet 6700 Revised 10/24/2018

Research Grade Xenon Arc Lamp Sources LH-Series 75 W - 300W

CUBE. Diode Laser System FEATURES

FTIR Spectrophotometer

NIR SPECTROSCOPY Instruments

Data sheet for TDS 10XX system THz Time Domain Spectrometer TDS 10XX

Advanced Features of InfraTec Pyroelectric Detectors

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Systems & Accessories

Bruker Optics Inc. Bruker Hong Kong Ltd. Billerica, MA USA Phone +1 (978) Fax +1 (978)

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

SR-5000N design: spectroradiometer's new performance improvements in FOV response uniformity (flatness) scan speed and other important features

FTIR. Far - Infrared Teraher t z. Tests. Instruments. Terahertz Spectrometer

WHITE PAPER MINIATURIZED HYPERSPECTRAL CAMERA FOR THE INFRARED MOLECULAR FINGERPRINT REGION

INTERFEROMETER VI-direct

How-to guide. Working with a pre-assembled THz system

Lambda 1050 / 950 UV/Vis/NIR

ABB MEASUREMENT & ANALYTICS. TALYS ASP500 series Flexible analyzer for real-time control of chemical processes

It s Our Business to be EXACT

Kit for building your own THz Time-Domain Spectrometer

LUMOS. Innovation with Integrity. FTIR Microscopy made easy FTIR

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Optical Spectrum Analyzers

2014 PRODUCT SELECTION GUIDE

Infrared wire grid polarizers: metrology, modeling, and laser damage threshold

LED Lighting Flux and Color Measurement System (LFC)

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Coherent Laser Measurement and Control Beam Diagnostics

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

TriVista. Universal Raman Solution

Company synopsis. MSU series

CUBE. Diode Laser System FEATURES & BENEFITS

THz Components and Systems

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

Genesis CX STM-Series

Imaging Fourier transform spectrometer

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

capabilities Infrared Contact us for a Stock or Custom Quote Today!

APPLICATION NOTE. Computer Controlled Variable Attenuator for Tunable Lasers. Technology and Applications Center Newport Corporation

SP-8001 UV/Visible Spectrophotometer

Power Sensors Introduction

671 Series LASER WAVELENGTH METER. The Power of Precision in Wavelength Measurement. It's Our Business to be Exact! bristol-inst.

Infra Red Interferometers

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

PREPARED BY: I. Miller DATE: 2004 May 23 CO-OWNERS REVISED DATE OF ISSUE/CHANGED PAGES

Installation and User Guide. FlexIR TM NIR Fiber Optic Accessory

T92+ UV-VIS SPECTROPHOTOMETER

OBIS CellX. The Universal Light Engine FEATURES

pulsecheck The Modular Autocorrelator

Basic Components of Spectroscopic. Instrumentation

PREPARED BY: I. Miller DATE: 2004 May 23 CO-OWNERS REVISED DATE OF ISSUE/CHANGED PAGES

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

VSR VERSATILE SPECTRO-RADIOMETER FOR INFRARED APPLICATIONS PERFORMANCE WITHOUT COMPROMISE

Laser Systems. !!!! iflex-iris

Spider Pulse Characterization

Mini-Chrom TM Monochromators

University of Wisconsin Chemistry 524 Spectroscopic Components *

INGAAS FAST PIN (RF) AMPLIFIED PHOTODETECTORS

Improving the Collection Efficiency of Raman Scattering

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Acton Research Spectroscopy Accessories

Components of Optical Instruments 1

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

Pulsed Laser Power Measurement Systems

APPLICATION NOTE. Computer Controlled Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

Advanced Test Equipment Rentals ATEC (2832)

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Supplementary Materials

Designing for Femtosecond Pulses

Transcription:

FINE XTG MONITORS BRIGHTNESS CONTRAST Modular Fourier Transform Infra-Red Spectrometer (FT-IR) Solution The Oriel FTIR Building Block solution has been designed for routine analytical applications for an FT-IR as well as non-traditional applications where modular design is required for flexibility in the optical path. This solution was designed specifically for researchers and OEMs who want an instrument easily adaptable to their special needs, at an economical price, and without compromising performance. The MIR835 scanner has selectable resolution starting with.5 cm -1, improved signal to noise ratio, and a very broad spectral range depending on choices of sources, optics, detectors, and beam splitters. The MIR835 sanner is commanded by MIRMat TM, a software package that provides sophistication for routine analysis and allows for custom routines to control the system. This package is also compatible with Active X. The MIR 835 TM FT-IR Spectrometer Scanner Modular design to meet various measurement requirements Wide spectral coverage; 14, to 7 cm -1 (7 nm to 14 µm) High resolution; up to.5 cm -1 (.2 nm at 7 nm and.2 µm at 14µm) Powered by MIRMat TM software Interchangeable detectors and IR sources for flexibility and adaptability to a myriad of applications The Components Oriel utilized a modular approach when designing the FT-IR solution. We made the components that restrict the use of FT-IR instruments (sources, detectors, and sample compartments) interchangeable, so there s no need to tear down the entire system when measurement requirments change simply switch out the component(s). A complete FT-IR Spectrometer solution includes: IR Source or sample MIR835 scanner Beam splitter and window Detection system MIRMat software How Does it Work? Fig. 1 illustrates how the FT-IR solution works. Very simply, the scanner modulates the radiation from the source or sample; the electronics board (in the scanner) digitizes the analog signals from the detection system and sends them to a computer through a USB 2. interface; and the MIRMat software is used for instrument control and data handling. MIR835 835 SCANNER A/D FILTER AMPLIFIER BOARD COARSE USB 2. DETECTION SYSTEM RADIATION SOURCE OR SAMPLE 835 SCANNER DATA ACQUISITION SOFTWARE Fig. 1 The heart of the MIR Mat Spectrometer solution is the scanner.

SCANNER Configurations of the FT-IR The flexibility of the modular FTIR Spectrometer solution allows users to choose either an Oriel or their own Source and Detector to complete the FTIR system. The flow chart above provides a quick reference to which detectors and sources are offered from Oriel. For questions, please contact a Newport Technical Sales Engineer at 1-877-835-962 or sales@newport.com. Optical Layout The MIR835 uses a scanning Michelson Interferometer. Our optical layout includes corner cubes and a retro-reflector. The unique layout is immune to tilt and shift as the retro-reflector and beam splitter are mounted together, providing accurate alignment while desensitizing the system to vibrations and temperature variations. This unibody approach to the beam splitter makes for easy interchangeability with minimal realignment required. INPUT/ OUTPUT RETRO REFLECTOR BEAM SPLITTER CORNER CUBES INPUT/OUTPUT Fig 2. Optical layout includes corner cubes and a retro-reflector mounted to a beam splitter Software - About MIRMat We didn t limit the flexibility of the Oriel MIR835 FT-IR scanner to its hardware; the software is also flexible. MIRMat is a powerful Windows TM based instrument control, data acquisition, and processing application, included with every instrument. For those who wish to do their own programming, we include an Active X interface to control the MIR835 from a custom software application. Software - Exporting Data For those familiar with MatLab, users know its power and almost unlimited capabilities - this is why we chose MatLab as our development platform. The 835 doesn t require MatLab in order to run, but the data can be exported to MatLab for further manipulation. Data can also be exported as standard ASCII text files into other numerical processing packages. Software - Configuring Parameters Set-up screens for parameter setting and data display are easy, intuitive, and friendly. Users can choose to display the data as an interferogram or one of many spectral options: single beam, transmittance, or absorbance, with abscissa in wavenumber or wavelength units. Previously acquired data can be retrieved for viewing or further manipulation. In addition, acquired data can be saved in ASCII for export to other programs. Software - Extensive Mathematical Functions MIRMat s Spectral Calculator enables extensive mathematical calculations on collected data. With a few intuitive keystrokes, standard deviation, absorbance, average and ratio spectra, and signal to noise ratio can be calculated to name only a few functions. Software - Active X Control Microsoft Active X Control allows users to build specific applications using Visual Basic, Visual C++, MatLab, LabVIEW, or other Microsoft applications compatible with Active X technology.

SCANNER PARAMETER 835 8351 Function Configuration Interferometer Exit Beam Divergence Spectral analyzer Main unit is an enclosed and purgeable chamber with KBr or CaF 2 input/output windows, containing an interferometric modulator 9 o Michelson interferometer with corner cube reflectors and retroprism 1 degree in full angle Beam Splitter KBr for near to far infrared CaF 2 for near to mid infrared Spectral Range 6, - 7 cm -1 (1.7-14 µm) Aperture (inch [mm]) 1.5 [38] Throughput Resolution 1 Scanning Mirror Speed at 4 khz (laser modulation frequency) Scanning Mirror Speed at 25 khz (laser modulation frequency) Scanning Mirror Speed at 15 khz (laser modulation frequency) 14, - 12 cm -1 (.7-8.3 µm) 7 x 1-3 (cm 2 Sr) for acceptance angle corresponding to 1 cm -1 resolution Selectable from.5-64 cm -1 in 8 steps; resolution corresponds to.2nm at 7nm and.2 µm at 14 µm 6.33 mm/s 3.956 mm/s 2.373 mm/s Scanning Mirror Speed at 5 khz.791 mm/s (laser modulation frequency) HeNe Laser Phase Tolerance 9 o +/- 3 Reference Signal Two HeNe laser sinusoidal interferograms in-quadrature for scanner control and data acquisition ZPD Point Scanning mirror can be finely adjusted by the software to get ZPD point exactly in the middle of a scan; this position will be maintained with zero error as long as the unit is powered up Interferogram Double sided Oversampling 1X, 2X, 4X Wave Number Accuracy.1 cm -1 Wave Number Resolution.5 cm -1 Signal to Noise Optical Axis Height - Bottom of Baseplate to Center of Aperture (inch [mm]) 1:1 at 25 cm -1, 4 cm -1 resolution, 1 scan sample/1 scan reference, using DTGS detector 2.88 [73.1] GENERAL Dimensions (inch [mm]) 16.5 x 11.8 x 8. [419 x 3 x 23] Weight (lbs [kg]) 37 [17] AC Voltage Input 84-264 VAC; 47-63 Hz Operating Temperature Range 15 o C to 4 o C, relative humidity cannot exceed 3% Storage Temperature Range o C to 5 o C, relative humidity cannot exceed 3% Coupling 1.5 inch series male flanges DATA ACQUISITION PARAMETER 835 8351 Computer Interface USB 2. Hardware Internal 16 bit A/D converter with 25 khz throughput Sample Frequency 16 khz - 2 khz with 4X oversampling 4 khz - 5 khz without oversampling Main Amplifier No gain control Low / High Pass Filters 93 Hz low pass filter (5 khz) and 8 khz high pass filter (4 khz) Software MIRMat Selectable Units µm, nm, cm -1, MHz, ev, kcal/mol, kj/mol, and K Type of Data Presentation Interferogram, single beam, transmittance SOFTWARE FUNCTION PARAMETER 835 8351 Set Scan Parameters Speed, resolution, oversampling on/off, bi-directional data acquisition on/off Scanner Calibration Fine adjustment of ZPD and delay of A/D converter triggering signals Set FFT Parameters Type of apodization, zero fill, parameters for phase correction and scaling Calculations Basic mathematic operations, Blackbody curve Save Data File Format Software Development COMPUTER REQUIREMENTS ASCII, Binary MatLab files Microsoft Active X control allows users to build specific application using Visual Basic, Visual C++, MatLab, LabVIEW, or other Microsoft application compatible technology MIRMat software is compatible with Windows XP (SP2 or SP3) and Windows 7 (32 bit). Memory 1GB of memory is the minimum required; performance will be improved with 4 GB of memory. Disk Space: 2MB of free disk space; 5 MB recommended. Collecting data from the instrument will generate many large data files so additional storage is needed. Graphics: Minimum screen resolution is 124 x 768 screen; optimum viewing is achieved with 128 x 124 resolution. Fig. 3 Schematic drawing of the Oriel 835 Scanner

Oriel Detector Offerings for FT-IR Solution Silicon and InGaAs Detectors for Oriel FT-IR Spectrometers DTGS Detector for Oriel FT-IR Spectrometers Model 819 Silicon Detector. Si and InGaAs models Includes focusing lens with XY adjustment This family of photodiode detectors covers the near infrared region, 14, to 6, cm -1 (.7 to 1.7 µm). We offer a Silicon and an InGaAs detector. The 819 Silicon Detector has excellent stability and sensitivity over the range of 14, - 1, cm -1. The 82 InGaAs Detector has a spectral range of 1, - 6, cm -1. These are the preferred detectors for Overtone Spectroscopy. NORMALIZED INTENSITY.6.4 2 WAVELENGTH (µm) 5. 2.5 1.66 1.25 33.714 82 InGaAs 819 Si 4 6 8 1 12 14 Fig. 4 Spectrum of 1273 K blackbody captured with InGaAs and Si Detectors, CaF 2 beam splitter and the 835 scanner Specifications - 819 / 82 InGaAs Detectors Responsivity Range 14, - 1, cm -1 (.7-1 µm) 819 Silicon Detector 82 InGaAs Detector 1, - 6, cm -1 (1-1.7 µm) Detector Element Size 1 µm diameter 1 µm diameter Window Material BK7 BK7 Preferred Beam Splitter CaF 2 CaF 2 Typical D* (cm Hz 1/2 W -1 ) 1 x 1 14 1 x 1 12 Operating Bandwidth (with amplifier) 1 Hz to 4 khz 1 1 Hz to 4 khz 1 Transimpedance gain (V/A) Selectable from 1 4 to 1 9 Selectable from 1 4 to 1 9 1 Gain Dependent Model 88 DTGS Detector at output of 835 scanner Broadest spectral response, 6, to 7 cm -1 Room temperature operation DTGS Detectors are sensitive from 6, to 7 cm -1 (1.7 to 14 µm), the usable range of the KBr beam splitter. This detector exhibits large, spontaneous electrical polarization effects. Incident radiation alters the polarization which generates the electrical signal. We optimize this detector for our 87 SiC Source; fine gain adjustments can be made via an internal potentiometer. NORMALIZED SIGNAL.6.4.6.4 WAVELENGTH (µm) 5. 2.5 1.66 1.25 88 DTGS DETECTOR WITH CaF2 BEAM SPLITTER 1 2 3 4 5 6 7 8 5. 2.5 1.66 1.25 88 DTGS DETECTOR WITH KBr BEAM SPLITTER 1 2 3 4 5 6 7 8 Fig. 5 Spectrum of 1273 K blackbody captured with 88 DTGS Detector, CaF 2 beam splitter was used to acquire the top measurement; a KBr beam splitter was used for the bottom measurement. Specifications - 88 DTGS Detector Responsivity Range 6, - 7 cm -1 (1.7-14 µm) Detector Element Size 2x2 mm Window Material Sapphire Preferred Beam Splitter CaF 2 Typical D* 1 x 1 4 Operating Bandwidth (with amplifier) 1 Hz to 4 khz

MCT Detectors for Oriel FT-IR Spectometers InSb Detectors for Oriel FT-IR Spectometers Model 826 MCT Detector High sensitivity Broad spectral response, 5, to 6 cm -1 The 826 is a liquid nitrogen cooled MCT detector. It has a broad spectral response, close to that of DTGS, but is sensitive to signals ~1X weaker. It also acquires data about 8X faster than DTGS. The 826 comes with an industry standard, 8 hour dewar. It has a two stage, low noise amplifier. The first stage has three settings: LOW (gain of 1), MED (gain of 3), and HIGH (gain of 1). The second stage provides AC coupling and 1X amplification. Model 821 InSb Detector Liquid nitrogen cooled detector Excellent performance in the 1, to 2, cm -1 range The 821 InSb Detector is a photovoltaic detector which approaches the maximum theoretical limit of sensitivity for background limited applications. This detector is ideal for background sensitive radiometry applications. It requires liquid nitrogen cooling. Holding time for LN 2 exceeds four hours. WAVELENGTH (µm) 5. 2.5 1.66 1.25.9 WAVELENGTH (µm) 5. 2.5 1.66 1.25.9 NORMALIZED SIGNAL.7.6.5.4.3 NORMALIZED SIGNAL.7.6.5.4.3.1.1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Fig. 6 Spectrum of 1273K blackbody captured with the 826 MCT Detector, KBr beam splitter and the 835 Scanner. Specifications - 826 MCT Detector Responsivity Range 5, - 6 cm -1 (2-17 µm) Detector Element Size 1x1 mm Window Material ZnSe Preferred Beam Splitter KBr Typical D* (Peak) 5 x 1 1 Operating Bandwidth (with amplifier) 1 Hz to 4 khz Fig. 7 Spectrum of 1273 K blackbody captured with 821 InSb Detector, CaF 2 beam splitter and the 835 Scanner Specifications - 821 InSb Detector Responsivity Range 1, - 2, cm -1 (1-5 µm) Detector Element Size 2x2 mm Window Material Sapphire Preferred Beam Splitter CaF 2 Typical D* 1 x 1 11 Operating Bandwidth (with amplifier) 1 Hz to 4 khz

Oriel Light Source Offerings for FT-IR Solution Broadband IR Sources For applications where a broadband source is required, we offer the 89 QTH and 87 SiC Sources. See Figs. 8 and 9 for spectral curves. Gold coated optics enhance IR output Designed for low light ripple output Specifications Spectral Range 14, to 2,8 cm -1 (.7 3.5 µm) 89 QTH 87 SIC 6, to 7 cm -1 (1.7 14 µm) Collimated Beam Diameter 38 mm 38 mm Light Ripple.1% peak to peak.1% peak to peak Power Supply AC Input 85-264 VAC, 47-63 Hz 85-264 VAC, 47-63 Hz ARBITRARY UNITS 12. 1. 8. 6. 4. 2.. 14. 12. 1. 8. 6. 4. 2. Fig. 8 Spectrum of 89 QTH Source taken by 835 with a CaF 2 beam splitter and 88 DTGS Detector ARBITRARY UNITS 7. 6. 5. 4. 3. 2. Quartz Tungsten Halogen (QTH) Infrared Light Source The 89 is a complete quartz tungsten halogen (QTH) infrared light source that provides a smooth continuum from 14, to 2,8 cm-1 (.7 to 3.5 µm). Its 1.5-Inch Series female output flange allows the source to be coupled to a variety of items, including the FT-IR Spectrometer Building Blocks. An off-axis parabolic reflector is integrated into the design, rather than a condenser lens. IR refractive optics are expensive and have transmittance limitations. Using this type of reflector provides several advantages. Its gold coating enhances IR reflectance. The focal point is displaced from the mechanical axis, giving full access to the reflector focus area. The 89 produces a 34.5 mm (1.36 inch) diameter collimated output beam with 1 divergence, full angle. A hose fitting is provided to purge the source with nitrogen, if desired. The 89 includes a 2-watt QTH lamp and a stand-alone power supply designed to minimize light ripple. A 1 m (3.3 ft.) long cable connects the source to its power supply. 2W QTH lamp model 6319 is the appropriate replacement for this source. Silicon Carbide (SiC) Infrared Light Source The 87 is a complete silicon carbide (SiC) infrared light source that provides a smooth continuum from 6, to 4 cm-1 (1.7 to 25 µm). Its 1.5-Inch Series female output flange allows the source to be coupled to a variety of items, including FT-IR Spectrometer Building Blocks. An off-axis parabolic reflector is integrated into the design, rather than a condenser lens. IR refractive optics are expensive and have transmittance limitations. Using this type of reflector provides several advantages. Its gold coating enhances IR reflectance. The focal point is displaced from the mechanical axis, giving full access to the reflector focus area. The 87 produces a 34.5 mm (1.36 inch) diameter collimated output beam with 1 divergence, full angle. A hose fitting is provided to purge the source with nitrogen, if desired. The 87 includes a 24-watt SiC emitter and a stand-alone power supply designed to minimize light ripple. A 1 m (3.3 ft.) long cable connects the source to its power supply. 24W SiC IR emitter model 83 is the appropriate replacment for this source.. 8. 7. 6. 5. 4. 3. 2. 1. Fig. 9 Spectrum of 87 SiC Source taken by 835 with a KBr beam splitter and 88 DTGS Detector

Accessories for Oriel FT-IR Spectrometers Convenient benchtop accessory compartment Fiber coupling accessories to simplify beam collection and delivery Below is a list of standard accessories to simplify measurements with the 835 FTIR scanner. Parabolas Fig. 1 illustrates the off-axis parabolas we use in the 835 scannes, detectors, and bench accessory. We offer them separately for those who wish to use them as collection optics. All parabolas are coated with gold to enhance IR reflectance. MODEL 8121 Accessory Compartment The 87 Accessory Compartment holds FT-IR sampling accessories at the proper optical height between the 835 Scanner and Detector. Use it with any Oriel FT-IR Detector. The 87 SiC Source, 89 QTH Source, or custom source is needed at the input of the Scanner, to complete the system. 1.125 (28.6) 7.28 (185.) EFL Fiber Coupling Accessories To carry the modulated output from the 835 scanner to a sample, or to carry sample radiation to the 835, we offer two fiber coupling accessories and various IR single core fibers. The 84 Fiber Coupler has an SMA fiber connector and a collecting mirror; it accepts SMA terminated fibers. The 833 is similar to the 84 but has X-Y translation for precise coupling, and does not include the fiber adapter. Choose between the 841 SMA, 842 ST and 843 11 mm Oriel ferrule, to complete the 833 Fiber Coupling Accessory. MODEL 8122 (2.3) 1.5 (38) DIA. 1.5 (38) DIA. (2.3) EFL IR Fibers We offer Chalcogenide and Polycrystalline fibers in 25 to 9 µm core diameters. Transmission for Chalcogenide is 2-6 µm and the Polycrystalline is 4-18 µm. MODEL 812 5.5 (139.7) EFL Collection Optics We offer the off-axis parabolas that are part of our 835 scanners and detectors, as stand alone collecting optics. Fig. 1 Off-axis parabolas 1.75 (44.5) DIA. (25.4)

Ordering Information Scanners Oriel 835 TM scanners include a beam splitter, two windows, and TM MIRMat software Model Beam Splitter & Window Material Spectral Range 835 KBr 6, - 7 cm -1 (1.7-14 µm) 8351 CaF 2 14, - 1,2 cm -1 (.7-8.3 µm) Replacement Beam Splitters Model Material Spectral Range 84 KBr 6, - 7 cm -1 (1.7-14 µm) 85 CaF 2 14, - 1,2 cm -1 (.7-8.3 µm) Replacement Windows (set of two) Model Material Spectral Range 81 KBr 6, - 7 cm -1 (1.7-14 µm) 811 CaF 2 14, - 1,2 cm -1 (.7-8.3 µm) Broadband IR Sources (includes lamp or emitter) Detectors Model Detector Type Usable Spectral Range 819 Si 14, - 1, cm -1 (.7-1 µm) 82 InGaAs 1, - 6, cm -1 (1-1.7 µm) 821 InSb 1, - 2, cm -1 (1-5 µm) 88 DTGS 6, - 7 cm -1 (1.7-14 µm) 826 MCT 5, - 6 cm -1 (2-17 µm) Accessories Model Description 87 Accessory Compartment 833 Fiber Coupler, Universal (requires adapter) 84 Fiber Coupler, SMA with X-Y Adjustment 841 SMA Adapter for 833 842 ST Adapter for 833 843 11 mm Ferrule Adapter for 833 Model Source Type Spectral Range 87 SiC Emitter 6, to 7 cm -1 (1.7 14 µm) 89 QTH Lamp 14, to 2,8 cm -1 (.7 3.5 µm) Replacement Source Components Model Description 83 24 W SiC Emitter 6319 2 W Quartz Tungsten Halogen Lamp Off-Axis Parabolas Model Effective Focal Length 812 5.5 (139.7 mm) Fiber Optic Cables Model Fiber Material 86 Chalcogenide Glass (CIR) 7695 Chalcogenide Glass (CIR) 7696 Chalcogenide Glass (CIR) 7697 Chalcogenide Glass (CIR) 7698 Polycrystalline (PIR) 7699 Polycrystalline (PIR) 7691 Polycrystalline (PIR) Transmittance Range Core Diameter (µm) 2-6 µm 5 5 (1.5) 2-6 µm 25 3 (1) 2-6 µm 4 3 (1) 2-6 µm 5 3 (1) 4. - 18 µm 4 3 (1) 4. - 18 µm 63 3 (1) 4. - 18 µm 9 3 (1) Length feet (m) 8121 7.28 (185. mm) 8122 (2.3 mm) 1791 Deere Avenue, Irvine, CA 9266, USA www.newport.com PHONE: 1-8-222-644 1-949-863-3144 FAX: 1-949-253-168 EMAIL: sales@newport.com Complete listings for all global office locations are available online at www.newport.com/contact Newport Corporation, Irvine, California and Franklin, Massachusetts; Evry and Beaune-la-Rolande, France and Wuxi, China have all been certified compliant with ISO 91 by the British Standards Institution. Santa Clara, California is DNV certified. 218 Newport Corporation. All rights reserved. DS-1156 ILX 1/18