Accurate Planar Near-Field Results Without Full Anechoic Chamber

Similar documents
MISSION TO MARS - IN SEARCH OF ANTENNA PATTERN CRATERS

IMPROVING AND EXTENDING THE MARS TECHNIQUE TO REDUCE SCATTERING ERRORS

SPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS

REFLECTION SUPPRESSION IN LARGE SPHERICAL NEAR-FIELD RANGE

ANECHOIC CHAMBER EVALUATION

APPLICATIONS OF PORTABLE NEAR-FIELD ANTENNA MEASUREMENT SYSTEMS

ALIGNMENT SENSITIVITY AND CORRECTION METHODS FOR MILLIMETER- WAVE SPHERICAL NEAR-FIELD MEASUREMENTS

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

SPHERICAL NEAR-FIELD MEASUREMENTS AT UHF FREQUENCIES WITH COMPLETE UNCERTAINTY ANALYSIS

A CYLINDRICAL NEAR-FIELD VS. SPHERICAL NEAR-FIELD ANTENNA TEST COMPARISON

RAYTHEON 23 x 22 50GHZ PULSE SYSTEM

A COMPOSITE NEAR-FIELD SCANNING ANTENNA RANGE FOR MILLIMETER-WAVE BANDS

33 BY 16 NEAR-FIELD MEASUREMENT SYSTEM

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

HOW TO CHOOSE AN ANTENNA RANGE CONFIGURATION

Near-Field Antenna Measurements using a Lithium Niobate Photonic Probe

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements

Sub-millimeter Wave Planar Near-field Antenna Testing

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS

PROBE CORRECTION EFFECTS ON PLANAR, CYLINDRICAL AND SPHERICAL NEAR-FIELD MEASUREMENTS

IMPLEMENTATION OF BACK PROJECTION ON A SPHERICAL NEAR- FIELD RANGE

Software. Equipment. Add-ons. Accessories. Services

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna

Antenna Measurement Uncertainty Method for Measurements in Compact Antenna Test Ranges

System configurations. Main features. I TScan SOLUTION FOR

HIGH ACCURACY CROSS-POLARIZATION MEASUREMENTS USING A SINGLE REFLECTOR COMPACT RANGE

ADVANTAGES AND DISADVANTAGES OF VARIOUS HEMISPHERICAL SCANNING TECHNIQUES

Upgraded Planar Near-Field Test Range For Large Space Flight Reflector Antennas Testing from L to Ku-Band

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Estimating Measurement Uncertainties in Compact Range Antenna Measurements

Keywords: cylindrical near-field acquisition, mechanical and electrical errors, uncertainty, directivity.

ON THE DEVELOPMENT OF GHZ ANTENNAS FOR TOWED DECOYS AND SUITABILITY THEREOF FOR FAR-FIELD AND NEAR-FIELD MEASUREMENTS

Implementation of a VHF Spherical Near-Field Measurement Facility at CNES

PRACTICAL GAIN MEASUREMENTS

Further Refining and Validation of RF Absorber Approximation Equations for Anechoic Chamber Predictions

> StarLab. Multi-purpose Antenna Measurement Multi-protocol Antenna Development Linear Array Antenna Measurement OTA Testing

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

The Design of an Automated, High-Accuracy Antenna Test Facility

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

T- DualScan. StarLab

60 GHz antenna measurement setup using a VNA without external frequency conversion

NTT DOCOMO Technical Journal. Method for Measuring Base Station Antenna Radiation Characteristics in Anechoic Chamber. 1.

A TURNKEY NEAR-FIELD MEASUREMENT SYSTEM FOR PULSE MODE APPLICATIONS

TRADITIONAL ANTENNA MEASUREMENTS AND CTIA OTA MEASUREMENTS MERGING THE TECHNOLOGIES

Main features. System configurations. I Compact Range SOLUTION FOR

METHODS TO ESTIMATE AND REDUCE LEAKAGE BIAS ERRORS IN PLANAR NEAR-FIELD ANTENNA MEASUREMENTS

ESTIMATING THE UNCERTAINTIES DUE TO POSITION ERRORS IN SPHERICAL NEAR-FIELD MEASUREMENTS

Millimetre Spherical Wave Antenna Pattern Measurements at NPL. Philip Miller May 2009

Uncertainty Analysis of Spherical Near Field Antenna Measurement System at VHF

Dependence of Antenna Cross-polarization Performance on Waveguide-to-Coaxial Adapter Design

Non-Ideal Quiet Zone Effects on Compact Range Measurements

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

AN AUTOMATED CYLINDRICAL NEAR-FIELD MEASUREMENT AND ANALYSIS SYSTEM FOR RADOME CHARACTERIZATION

HScan. Horizontal Scanner

Optimizing a CATR Quiet Zone using an Array Feed

System configurations. Main features I SG 64 SOLUTION FOR

The CDT Ultra Wide-Band Anechoic Chamber. Félix Tercero, José Manuel Serna, Tim Finn, J.A.López Fernández INFORME TÉCNICO IT - OAN

Gain And Arbitrary Beamwidth Measurement For Identical Test Antennas

TRANSMITTING ANTENNA WITH DUAL CIRCULAR POLARISATION FOR INDOOR ANTENNA MEASUREMENT RANGE

Introduction Antenna Ranges Radiation Patterns Gain Measurements Directivity Measurements Impedance Measurements Polarization Measurements Scale

Fully Anechoic Room Validation Measurements to CENELEC pren

Multiple Target, Dynamic RF Scene Generator David J. Wayne, Scott T. McBride, John T. McKenna NSI-MI Technologies Suwanee, GA, USA

SPHERICAL NEAR-FIELD ANTENNA MEASUREMENTS: A REVIEW OF CORRECTION TECHNIQUES

Comparison of antenna measurement results in disturbed environment using a VHF spherical near field system

Characterization of a Photonics E-Field Sensor as a Near-Field Probe

Over the Air Testing: Important Antenna Parameters, Testing Methodologies and Standards

Fundamentals. Senior Project Manager / AEO Taiwan. Philip Chang

1 Engineer s Test Lab Handbook THE ANTENNA MEASUREMENT STANDARD IEEE 149 FINALLY GETS AN UPDATE

Chapter 41 Deep Space Station 13: Venus

Structural Correction of a Spherical Near-Field Scanner for mm-wave Applications

Uncertainty Considerations In Spherical Near-field Antenna Measurements

Millimeter Spherical µ-lab System from Orbit/FR

Numerical Calibration of Standard Gain Horns and OEWG Probes

Principles of Planar Near-Field Antenna Measurements. Stuart Gregson, John McCormick and Clive Parini. The Institution of Engineering and Technology

HISTOGRAM EQUALISATION AS A METHOD FOR MAKING AN OBJECTIVE COMPARISON BETWEEN ANTENNA PATTERNS FUNCTIONS

18th International Symposium on Space Terahertz Technology. Measurement of a high-gain antenna at 650 GHz in a hologram-based CATR

5G Antenna System Characteristics and Integration in Mobile Devices Sub 6 GHz and Milli-meter Wave Design Issues

COMPARATIVE ANALYSIS BETWEEN CONICAL AND GAUSSIAN PROFILED HORN ANTENNAS

The Importance of Polarization Purity Author: Lars J Foged, Scientific Director at MVG (Microwave Vision Group)

Spherical Scanning Measurement Challenge for Future Millimeter Wave Applications

Absorbers and Anechoic Chamber Measurements

A LABORATORY COURSE ON ANTENNA MEASUREMENT

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

EHF Rotman Lens Fed Linear Array Multibeam Planar Near-Field Range Measurements CST 5 th NORTH AMERICAN USERS FORUM 4th FEBRUARY 2008 SANTA CLARA, CA

Introduction to Measurement Techniques

Chapter 7 - Experimental Verification

THROUGHOUT the last several years, many contributions

Circularly Polarized Post-wall Waveguide Slotted Arrays

Dr. John S. Seybold. November 9, IEEE Melbourne COM/SP AP/MTT Chapters

ANTENNA INTRODUCTION / BASICS

ANTENNA INTRODUCTION / BASICS

MAKING TRANSIENT ANTENNA MEASUREMENTS

PRIME FOCUS FEEDS FOR THE COMPACT RANGE

Narrow Pulse Measurements on Vector Network Analyzers

MEASUREMENT OF THE EARTH-OBSERVER-1 SATELLITE X-BAND PHASED ARRAY

A BROADBAND POLARIZATION SELECTABLE FEED FOR COMPACT RANGE APPLICATIONS

Differential and Single Ended Elliptical Antennas for GHz Ultra Wideband Communication

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

LE/ESSE Payload Design

Transcription:

Accurate Planar Near-Field Results Without Full Anechoic Chamber Greg Hindman, Stuart Gregson, Allen Newell Nearfield Systems Inc. Torrance, CA, USA ghindman@nearfield.com Abstract - Planar near-field antenna measurements have largely been performed within fully absorber lined anechoic chambers. However, when measuring medium to high gain antennas, one can often obtain excellent results when testing within only a partially absorber lined chamber [1], or in some cases even when using absorber placed principally behind the acquisition plane. As absorber can be bulky and costly, its usage often becomes a significant factor when planning a new facility. This situation becomes more difficult when the designated test environment is not exclusively devoted to antenna pattern testing with non-ideal absorber coverage being, in some cases, mandated, c.f. EMC testing. Planar test systems lend themselves to deployment within multipurpose installations as they are routinely constructed so as to be portable [2] thereby allowing partial or perhaps complete removal of the test system between measurement campaigns. Many of NSI s large planar near-field system installations are implemented with only a partially lined chamber [3] This paper will present measured data taken using a number of different planar antenna test systems with and without anechoic chambers to summarize what is achievable and to provide design guidelines for testing within non-ideal anechoic environments. NSI s Planar Mathematical Absorber Reflection Suppression (MARS) technique [4, 5, 6] will be utilized to show additional improvements in performance that can be achieved through the use of modern sophisticated post processing. Keywords: Absorber, Chamber, Planar Near-Field, Reflection Suppression, Scattering, MARS. I. INTRODUCTION The goal of the paper is to show real measured results obtained from several planar near-field measurement systems employing different chamber / absorber treatments. Three different systems will be used to demonstrate that when medium to high gain antennas are tested on planar near-field systems, a full anechoic environment is often not required. To demonstrate this, an antenna with known radiation pattern will be measured on all three systems with various absorber configurations, including the case where no absorber is used at all. II. ANTENNA USED FOR COMPARISON TESTS The antenna under test was a Litton 12 inch Slotted WaveGuide Array (SWGA) operating at 9.375 GHz. NSI often uses antennas of these types for our on-site range accuracy assessments, and for conducting range assessments using the NIST 18 term range assessment procedure. This light-weight, mechanically rigid, antenna has a peak directivity of approximately 28 dbi, making it an ideal candidate for measurement on a PNF system. It also has sufficiently low sidelobes to allow for accuracy assessments to be performed on them. Figure 1 shows an image of the Litton 12 SWGA along with some performance specifications. Antenna Frequency 12 SWGA 9.375 GHz 3 db Beamwidth ~ 8 deg Directivity E-plane sidelobes H-plane sidelobes Figure 1 - AUT Used for Comparisons ~ 28 dbi ~ db ~ db III. SUMMARY OF SYSTEMS USED FOR TESTING Three different planar near-field systems were used to test the SWGA. First, NSI s in-house 3V-12x12 scanner, shown in Figure 2, was selected as the baseline system for the comparison. Numerous range assessments have been completed using this system so there is an abundance of documentation regarding typical achievable uncertainties. Detailed RF, mechanical and alignment calibration logs are also available. In addition, this chamber has 36 back wall pyramidal absorber, which should provide maximum attenuation of stray signals, which is of primary interest for this paper. This system resides within an anechoic chamber, which is an industry standard for high accuracy near-field systems. Note that even though the scanner has a large 12 x12 scan plane, our testing was performed only over a 5 x5 scan area to allow direct comparison with subsequent testing which was performed on a portable 5 x5 scanner. The effect of truncation to a 5 x5 plane for this antenna testing over the ±6 degree angular coverage window used for this evaluation was negligible. Next, the NSIVx5 shown in Figure 3 and Figure 6 was used. This system is used primarily for research and development tasks at NSI, but operates to the same mechanical and RF tolerances as the reference system. The first difference between this scanner and the reference is the reduction in total scan area available. This system has 5 ft of travel in both X and Y axes, while the first system can acquire data over a 12x12 ft

surface. The second major difference between the two systems is the lack of anechoic chamber for this scanner. Figure 2 shows that this chamber is typically installed within in an openlaboratory environment lacking any absorber treatment. For the purposes of this paper, 12 pyramidal absorber was added behind the scan plane only. The last system used for these evaluations was another NSI- 2Vx5 planar near-field scanner. This system is not a permanent fixture at NSI as it is eventually destined to be delivered to a customer. Prior to delivery to customers, all of these systems must be validated mechanically and electrically to confirm conformance with performance specifications. During this evaluation, the SWGA was mounted as AUT to serve both as RF validation and to provide additional data for the purposes of this paper. In this case, the system was evaluated with no absorber (Figure 7), 4 flat absorber (Figure 5) and Figure 12 pyramidal absorber (Figure 4). TABLE I below shows a summary of the test systems and configurations used here. In all of these test systems, the range was configured with both a probe Z translation stage, and an AUT Z translation stage. The probe stage is typically used to take two data sets at ¼ wavelength apart to suppress on-axis multipath between AUT and probe. We also use the AUT Z axis translation stage to allow changes between the AUT and the scanner tower and back wall absorber for range reflection evaluation. The majority of the testing was performed with dual probe-z and dual AUT-Z measurements for the processing shown here, although single Z results are also summarized in TABLE II. The nominal AUT to probe separation used was 6 wavelengths so as to minimize truncation, multiple reflections. etc. TABLE I. SYSTEMS USED FOR TESTING Back Wall Test Scanner Location Figure Absorber 1 2 3 4 5 6 3V- 12x12 2V- 2V- 2V- 2V- 2V- Chamber 36 pyramidal 2 Lab 12 Pyramidal 3 Lab 12 Pyramidal 4 Lab 4 Flat 5 Lab None 6 Lab None 7 IV. PATTERN MEASUREMENT RESULTS The results of the testing in the 6 configurations are shown in Figure 8 thru 13 in the form of 2D false color checkerboard images, and Figure 14 thru 19 in the form of Azimuth (Eplane) pattern cuts and comparisons. Elevation (H-plane) results were similar and omitted for the sake of brevity. As can be seen in the 2D images, the test result from the full anechoic chamber (Figure 8), is virtually identical to the results from the two tests on the systems with only pyramidal absorber installed behind the scanner plane (figures 9 and 1). The result in Figure 11 with the 4 flat absorber back wall behind the scanner is very similar but some sidelobe ripple is noticeable at the right hand side of the pattern. Figure 12 and Figure 13 from the testing with no absorber behind the scanner show noticeable corruption in the antenna pattern sidelobes all over. In Figure 14, we show the baseline E-plane pattern used from the 3V-12x12 system in the full anechoic chamber. In Figure 15 thru Figure 19 we show the results from the other systems with various types of absorber treatment and also include a subtraction from the baseline pattern and show a residual Error to Signal (E/S) ratio [7], which is used as a measure of similarity. In Figure 15, for instance, we see that the pattern subtraction E/S level shows about -42 db peak error and about 4 db RMS error level, which is excellent for a system with only back wall absorber. In Figure 16 the other 5 x5 scanner with only a 12 pyramidal backwall absorber, we see about a db peak error level and a 2 db RMS error level. The RMS error levels on the other 3 comparisons, with 4 absorber backwall, and both systems with no absorber, have poorer RMS error levels of -49 db, db and -43 db respectively. See TABLE II below, summarizing the RMS E/S ratios for the various configurations vs. the baseline data in the full anechoic chamber. Note that in that table we also show the results if only a single Z plane measurement were acquired and the results are also quite acceptable for many test applications. Note that we also processed the data with NSI s Planar MARS (P-MARS) technique to suppress residual errors (mostly arising from range multipath) and we show that results in TABLE II as well, and one can see the additional improvement up to 12 db for one of the test cases with no absorber wall! See Figure 2 below. TABLE II. RESULTS OF PATTERN TESTS RMS E/S ratio vs REF Test Scanner Loc Back 1Z 4Z MARS Wall Abs 1 3V- 12x12 2 2V- 3 2V- 4 2V- 5 2V- 6 2V- Cha 36 Pyr REF Lab 12 Pyr 3 4-61 Lab 12 Pyr 2 5 Lab 4 Flat -47-49 2 Lab None -42 1 Lab None -41-43 5

Figure 2-3V-12x12 PNF in NSI Chamber with 36 Back Wall Absorber Figure 5-2Vx5 PNF Scanner in NSI Lab with 5" Tower Absorber and wall of 4" Flat Absorber Behind Scanner Figure 3-2Vx5 PNF Scanner in NSI Lab with Small Section of 12" Back Wall Absorber Figure 6-2Vx5 Scanner with No Back Wall Absorber Figure 4-2Vx5 PNF Scanner in NSI Lab with wall of 12" Pyramidal Absorber Behind Scanner Figure 7-2Vx5 PNF Scanner in NSI Lab with No Back Wall Absorber

Figure 8 - Main Component Amplitude for 3V-12x12 with 36 Absorber Figure 11 - Main Component Amplitude for 2Vx5 #2 with 4 Flat Absorber Figure 9- Main Component Amplitude for 2Vx5 #1 with 12 Absorber Figure 12- Main Component Amplitude for 2Vx5 #1 with no Absorber Figure 1 - Main Component Amplitude for 2Vx5 #2 with 12 Absorber Figure 13- Main Component Amplitude for 2Vx5 #2 with no Absorber

Far-field amplitude of Litton12_NSI_12x12A_113.NSI Far-field amplitude of Litton12_NSI_12x12A_113.NSI - Far-field amplitude of Litton12_NSI_5x5_TU_E_lab_1.nsi Frequency = 9.375 GHz; RMS Level = -49.9 db; Peak Level = -36.82 db at -7.5 deg 5 5 12x12 REF 5x5 with 4" FLAT ABS Plot 1 - Plot 2 2 4 6 Figure 14 - Baseline E-Plane Cut of SWGA on NSIV-12x12 2 4 6 Figure 17-2Vx5 #2 with 4 Flat Absorber Compared to Baseline Far-field amplitude of Litton12_NSI_12x12A_113.NSI - Far-field amplitude of Litton12_NSI_5x5_21.NSI Frequency = 9.375 GHz; RMS Level = 3.7 db; Peak Level = -41.76 db at 6. deg Far-field amplitude of Litton12_NSI_12x12A_113.NSI - Far-field amplitude of Litton12_NSI_5x5_17.NSI Frequency = 9.375 GHz; RMS Level = -44.55 db; Peak Level = -31.49 db at -1.8 deg 12x12 REF 5x5 with 12" PYR ABS Plot 1 - Plot 2 12x12 REF 5x5 NO ABS Plot 1 - Plot 2 5 5 2 4 6 Figure 15-2Vx5 #1 with 12 Absorber Compared to Baseline 2 4 6 Figure 18-2Vx5 #1 with no Absorber Compared to Baseline Far-field amplitude of Litton12_NSI_12x12A_113.NSI - Far-field amplitude of Litton12_NSI_5x5_TU_E_lab_1.nsi Frequency = 9.375 GHz; RMS Level = 1.59 db; Peak Level = -39.69 db at -6. deg Far-field amplitude of Litton12_NSI_12x12A_113.NSI - Far-field amplitude of Litton12_NSI_5x5_TU_E_lab_4.nsi Frequency = 9.375 GHz; RMS Level = -42.5 db; Peak Level = -29.75 db at 1.5 deg 12x12 REF with 12" PYR ABS Plot 1 - Plot 2 12x12 REF with NO ABS Plot 1 - Plot 2 5 5 2 4 6 Figure 16-2Vx5 #2 with 12 Absorber Compared to Baseline 2 4 6 Figure 19-2Vx5 #2 with no Absorber Compared to Baseline

El 6 5 4 5 3 2 5 1 5 5 E Az (db) Figure 2 Result of MARS processed comparison between reference pattern from full chamber, vs. test in lab with no back wall absorber behind 5 x5 scanner -3-2 -1-4 1 2 3 4 5 6 Az -4-3 -2-1 5 References [1] A.C. Newell, Error Analysis Techniques for Planar Near-Field Measurements, IEEE Transactions on Antennas and Propagation, AP- 36, p. 581, 1988. [2] S.F. Gregson, A.C. Newell, G.E. Hindman, M.J. Carey, Extension of The Mathematical Absorber Reflection Suppression Technique To The Planar Near-Field Geometry, AMTA, Atlanta, October 21. [3] G. E. Hindman, G.F. Masters, Implementation Of A 22' X 22' Planar Near-Field System For Satellite Antenna Measurements, AMTA, October, 1993. [4] G.E. Hindman, Applications of Portable Near-Field Antenna Measurement Systems, AMTA, October, 1991. [5] S.F. Gregson, A.C. Newell, G.E. Hindman, Advances In Planar Mathematical Absorber Reflection Suppression, AMTA, Denver, Colorado, October 211. [6] S.F. Gregson, A.C. Newell, G.E. Hindman, P. Pelland, Range Multipath Reduction In Plane-Polar Near-Field Antenna Measurements, AMTA, Seattle, October 212. [7] A.C. Newell, G.E. Hindman, Antenna Pattern Comparison Using Pattern Subtraction and Statistical Analysis, EUCAP, 211 V. SUMMARY These results have shown that for PNF measurements on medium to high gain antennas, excellent results can be achieved without a full anechoic chamber. One can often just construct a wall of pyramidal absorber behind the scanner to suppress reflections off the back wall. This can allow more economical measurements to be made without the investment in an expensive anechoic chamber. For cylindrical or spherical near-field systems (CNF or SNF), a full anechoic chamber is often recommended, however in many cases it may be adequate to just cover only the 4 side walls, particularly in the Phi/Theta geometry where the antenna s main beam is only pointed azimuthally and does not illuminate the ceiling and floor regions. Additionally, NSI s mathematical absorber reflection suppression technique can be employed to further improve the quality of the results obtained as these are now available for use with planar, cylindrical and spherical nearfield systems, as well as with far-field and CATRs.