Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Similar documents
FLEX Ex Thermocouple/RTD Input Module

FLEX Ex Power Supplies

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

ControlNet Ex Tap Terminator Installation Instructions

Allen-Bradley Spares

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

FLEX Ex System Certification

CERTIFICATE OF COMPLIANCE

Isolators A3/1. Vibration Transducer Supply Unit Series

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Binary Output Series 9175

Intrinsic Safety Control Drawing

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

IP26 Series Current to Pneumatic Converter

FLEX Ex 8 Input Analog, HART, and Noise Filter Analog Modules

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Temperature Input Module for Zone 1 Series 9482/32

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Analog Universal Module HART for Zone 2 Series 9468/33

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Digital Input Output Module for Zone 2 Series 9470/33

Certificate of Compliance

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Binary Output without Power Supply Series 9176

Digital Input Output Module for Zone 2 Series 9470/33

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Loop Powered Indicator

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Head mounted Temperature Transmitter TF02/TF02-Ex

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolating Repeater Input Series 9163

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

FOUNDATION Fieldbus Junction Box

Digital Input Output Module for Zone 1 Series 9470/32

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Safety Instructions Nivotester FTC625, FTC325

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

SINEAX TI 807 Passive DC signal isolator

Inductive sensor slot-type SI2-K08-AP7

INSTRUCTION & SAFETY MANUAL

onlinecomponents.com

Industrial Pressure Transducers

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

SALES SERVICE +358 (0)

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

ATEX Installation Drawings and Instructions

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Isolators A3/1.

Remote I/O. 74 Remote I/O. Remote I/O System

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

... for hydraulic and general applications in hazardous areas

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

General Specifications

1715 Redundant I/O System Specifications

Operating Manual. isolate501

Railbus isolator. Railbus isolator 8922-RB-IS

Power supply. Calibration. Surface finishing. Seal. Process connection

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

protim-r Module

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

Rosemount 148 Temperature Transmitter

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Level Lance Model 5100

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

CERTIFICATE OF COMPLIANCE

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Single-Channel Safety Barriers Series 9001

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital I/O Coupler (4-wire) Series 9413/21

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

PRetrans Table of contents

User's Manual Model SE14 Magnetic Flow Converter

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Product manual wire programmable RTD transmitter

protim-r Module

Transcription:

Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional Data Range Data Format Step Response to 99% of FS Module from Adapter Best/Worst Update Time Indicators Output (Intrinsically Safe) (16 pin male/female flexbus connector) Isolation Path Input to Power Supply Input to Flexbus Input to Input Power Supply to Flexbus Power Supply (+V, -V intrinsically safe) Module Field-side Power Consumption 8 single-ended, non-isolated EEx ia IIB/IIC T4 AEx ia IIC T4 Class I, II, III Division 1 Groups A-G T4 (1797-IE8) Class I, II, III Division 1 & 2 Groups A-G T4 (1797-IE8NF) EEx ib IIB/IIC T4 AEx ib IIC T4 Class I Division 1 & 2 Groups A-D T4 16 bits 0.1% of output signal range 0.005%/C of output signal range >15V @22mA >21.5V @ 0mA Configurable 4ms 50/1450µs 8 red fault indicators 1 green power U i < 5.8V dc I i < 400mA L i = Negligible C i < 1.35µF Isolation Type Galvanic to DIN EN50020 Galvanic to DIN EN50020 None Galvanic to DIN EN50020 U i < 9.5V dc I i < 1A L i = Negligible C i = Negligible 7.5W 1

A-2 Specifications Power Dissipation 5.2W Thermal Dissipation 17.75 BTU/hr Module Location Cat. No. 1797-TB3 or -TB3S Conductor Wire Size 12 gauge (4mm 2 ) stranded maximum 3/64in (1.2mm) insulation maximum Dimensions 46mm x 94mm x 75mm (1.8in x 3.7in x 2.95in) Weight 200g (approximately) Keyswitch Position 3 Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Nonoperating Vibration Agency Certification CENELEC UL, C-UL FM Certificates CENELEC -20 to +70 o C (-4 to +158 o F) -40 to +85 o C (-40 to +185 o F) 5 to 95% noncondensing Tested to 15g peak acceleration, 11(+1)ms pulse width Tested to 15g peak acceleration, 11(+1)ms pulse width Tested 2g @ 10-500Hz per IEC68-2-6 II (1) 2G EEx ia/ib IIB/IIC T4 II (1D) (2D) Class I Division 1 & 2 Groups A-D T4 Class I Zone 1 & 2 AEx ib/[ia] IIC T4 Class I Division 1 Groups A-D T4 Class I Zone 1 AEx ib/[ia] IIC T4 DMT 98 ATEX E 020 X UL, C-UL UL Certificate Number 99.19699 C US Class I Division 1 Hazardous FM FM Certificate Number 3009806 FM

Specifications A-3 1797-IE8 and -IE8NF CE, CENELEC I/O Entity Parameters Measurement input (sig to -) for ch 0 to ch 7 (terminals: 1-2; 5-6; 9-10; 13-14; 18-19; 22-23; 26-27; 30-31) U o = 5V I o = 1mA P o = 1.3mW U i = 28V I i = 93mA C i and L i negligible Protection Group Allowed Capacitance EEx ia IIB 1000µF 1H IIC 100µF 1H Allowed Inductance Source output (+ to sig) for ch 0 to ch 7 (terminals: 0-1; 4-5; 8-9; 12-13; 17-18; 21-22; 25-26; 29-30) U o = 23.7V I o = 92.5mA P o = 548mW If concentrated capacitance and/or inductance are available, use the following values. Protection Group Allowed Capacitance Allowed Inductance EEx ia IIB 560nF 10mH IIC 66nF 2.5mH EEx ia IIB 320nF 10mH IIC 60nF 2mH Source output plus measurement input (+ to -) for ch 0 to ch 7 (terminals: 0-2; 4-6; 8-10; 12-14; 17-19; 21-23; 25-27; 29-31) U o = 23.7V I o = 93.5mA P o = 555mW If concentrated capacitance and/or inductance are available, use the following values. Protection Group Allowed Capacitance Allowed Inductance EEx ia IIB 560nF 10mH IIC 66nF 2.5mH EEx ia IIB 320nF 10mH IIC 60nF 2mH

A-4 Specifications 1797-IE8 and -IE8NF UL, C-UL I/O Entity Parameters If this product has the UL/C-UL mark, it has been designed, evaluated, tested, and certified to meet the following standards: UL 913, 1988, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III Division 1, Hazardous (Classified) Locations UL 1203, Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations UL 2279, Electrical Equipment for Use in Class I, Zone 0, 1, and 2 Hazardous (Classified) Locations UL 508, Industrial Control Equipment CSA C22.2 No. 157-92, Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations CSA C22.2 No. 30-M1986, Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA-E79-0-95, Electrical Apparatus for Explosive Gas Atmospheres, Part 0: General Requirements CSA-E79-11-95, Electrical Apparatus for Explosive Gas Atmospheres, Part 11: Intrinsic Safety i CSA C22.2 No. 14-95, Industrial Control Equipment Wiring Methods Table 1 Wiring method 1 - Each channel is wired separately. Wiring method 2 - Multiple channels in one cable, providing each channel is separated in accordance with the National Electric Code (NEC) or Canadian Electric Code (CEC). Wiring Channel Terminals V oc (V) I sc (ma) V t (V) I t (ma) Groups C a (µf) L a (mh) Method 1 and 2 Any one 0(+), 1(sig) 23.7 92.5 - - A, B, IIC 0.06 2.0 channel e.g. ch0 C, E, IIB 0.18 8.0 D, F, G, IIA 0.48 16.0 1(sig), 2(-) 5 1.0 - - A, B, IIC 100 1000 C, E, IIB 300 1000 D, F, G, IIA 800 1000 0(+), 1(sig), 2(-) - - 23.7 93.5 A, B, IIC 0.06 2.0 C, E, IIB 0.18 8.0 D, F, G, IIA 0.48 16.0

Specifications A-5 FLEX Ex Analog Input I/O Module A-B Allen-Bradley 8 CHANNEL ANALOG INPUT 0 1 2 3 4 5 6 1797- IE8 7 PWR 3 Key Position for Insertion LEDs Female Bus Connection Male Bus Connection Key Field Wiring Terminals 42055 IMPORTANT A terminal base may or may not have an I/O module installed. Hazardous (Classified) Location Class I, Zones 0, 1, & 2 Groups IIC, IIB, IIA Class I, Div. 1 & 2 Groups A, B, C, D Class II, Div. 1 & 2 Groups E, F, G Class III, Div. 1 & 2 Hazardous (Classified) Location Class I, Zones 1 & 2 Groups IIC, IIB, IIA Class I, Div. 1 & 2 Groups A, B, C, D Any Simple Apparatus or I.S. device with Entity Concept parameters (V max, I max, C i, L i ) appropriate for connection to associated apparatus with Entity Concept parameters listed in Table 1. ch0 ch1 ch2 ch3 ch4 ch5 ch6 ch7 0 (+) 1 (sig) 2 (-) 4 (+) 5 (sig) 6 (-) 8 (+) 9 (sig) 10 (-) 12 (+) 13 (sig) 14 (-) 17 (+) 18 (sig) 19 (-) 21 (+) 22 (sig) 23 (-) 25 (+) 26 (sig) 27 (-) 29 (+) 30 (sig) 31 (-) Female Bus V max =5.8V I max =400mA C i =1350nF L i =negligible V max =9.5V I max =1A C i =negligible L i =negligible Male Bus 1797-IE8 or 1797-IE8NF 34 35 51 50 16 33 40 41 42 43 44 45 To any intrinsically safe device or associated apparatus with Entity Concept parameters of V oc < 5.8V; I sc < 400mA. To any intrinsically safe device or associated apparatus with Entity Concept parameters of V oc < 9.5V; I sc < 1A. To any IS device with Entity Concept parameters of (V max, I max, C i, L i ) appropriate for connection to associated apparatus with Entity Concept parameters listed in Table 2. Shield Connection Only 42056

A-6 Specifications Table 2 Terminals V t (V) I t (ma) Groups C a (µf) L a (µh) Male Bus 5.8 400 A-G 3.0 3.0 The entity concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of V oc and I sc or V t and I t of the associated apparatus are less than or equal to V max and I max of the intrinsically safe apparatus and the approved values of C a and L a of the associated apparatus are greater than C i + C cable and L i + L cable respectively for the intrinsically safe apparatus. Simple apparatus is defined as a device which neither generates nor stores more than 1.2V, 0.1A, 20µJ, or 25mW. Wiring methods must be in accordance with the National Electric Code, ANSI/NFPA 70, Article 504 and 505 or the Canadian Electric Code CSA C22.1, Part 1, Appendix F. For additional information refer to ANSI/ISA RP12.6. This module, 1797-IE8 or -IE8NF, must be used with terminal base 1797-TB3 or 1797-TB3S. Terminals 3, 7, 11, 15, 20, 24, 28, 32, 36-39, and 46-49 shall not be connected. WARNING: Substitution of components may impair intrinsic safety. AVERTISSEMENT: La substitution de composant peut compromettre la securite intrinseque.

Specifications A-7 1797-IE8 and -IE8NF FM I/O Entity Parameters If this product has the FM mark, it has been designed, evaluated, tested, and certified to meet the following standards: FM C1. No.3600:1998, Electrical Equipment for Use in Hazardous (Classified) Locations General Requirements FM C1. No.3610:1999, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, III Division 1 Hazardous (Classified) Locations FM C1. No.3615:1989, Explosionproof Electrical Equipment General Requirements FM C1. No.3810:1989, 1995, Electrical and Electronic Test, Measuring and Process Control Equipment ANSI/NEMA 250, 1991, Enclosures for Electrical Equipment Wiring Methods Table 1 Wiring method 1 - Each channel is wired separately. Wiring method 2 - Multiple channels in one cable, providing each channel is separated in accordance with the National Electric Code (NEC). Wiring Channel Terminals V oc (V) I sc (ma) V t (V) I t (ma) Groups C a (µf) L a (mh) Method 1 and 2 Any one 0(+), 1(sig) 23.7 92.5 - - A, B 0.15 4.0 channel e.g. ch0 C, E 0.45 12.0 D, F, G 1.20 32.0 1(sig), 2(-) 5 1.0 - - A, B 100 1000 C, E 300 1000 D, F, G 800 1000 0(+), 1(sig), 2(-) - - 23.7 93.5 A, B 0.15 4.0 C, E 0.45 12.0 D, F, G 1.20 32.0

A-8 Specifications FLEX Ex Analog Input I/O Module A-B Allen-Bradley 8 CHANNEL ANALOG INPUT 0 1 2 3 4 5 6 1797- IE8 7 PWR 3 Key Position for Insertion LEDs Female Bus Connection Male Bus Connection Key Field Wiring Terminals 42055 IMPORTANT A terminal base may or may not have an I/O module installed. Hazardous (Classified) Location Class I, Zones 0 Groups IIC Class I, Div. 1 Groups A, B, C, D Class II, Div. 1 Groups E, F, G Class III, Div. 1 Hazardous (Classified) Location Class I, Zones 1 Groups IIC Class I, Div. 1 Groups A, B, C, D Any Simple Apparatus or FM approved device with Entity Concept parameters (V max, I max, C i, L i ) appropriate for connection to associated apparatus with Entity Concept parameters listed in Table 1. ch0 ch1 ch2 ch3 ch4 ch5 ch6 ch7 0 (+) 1 (sig) 2 (-) 4 (+) 5 (sig) 6 (-) 8 (+) 9 (sig) 10 (-) 12 (+) 13 (sig) 14 (-) 17 (+) 18 (sig) 19 (-) Female Bus V max =5.8V I max =400mA C i =1350nF L i =negligible V max =9.5V I max =1A C i =negligible L i =negligible 34 35 51 50 21 (+) Male Bus 22 (sig) 23 (-) 25 (+) 16 26 (sig) 33 27 (-) 40 1797-IE8 or41 42 29 (+) 1797-IE8NF43 30 (sig) 44 31 (-) 45 For connection to other modules, refer to the General FM Certification Information on page 29-1 in 1797-6.5.6. From FM approved devices, 1797-PS2N. For connection to other modules, refer to the General FM Certification Information on page 29-1 in 1797-6.5.6. Shield Connection Only 42056

Specifications A-9 Table 2 Terminals V t (V) I t (ma) Groups C a (µf) L a (µh) Male Bus 5.8 400 A-G 3.0 3.0 The entity concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of V oc and I sc or V t and I t of the associated apparatus are less than or equal to V max and I max of the intrinsically safe apparatus and the approved values of C a and L a of the associated apparatus are greater than C i + C cable and L i + L cable respectively for the intrinsically safe apparatus. Simple apparatus is defined as a device which neither generates nor stores more than 1.2V, 0.1A, 20µJ, or 25mW. Wiring methods must be in accordance with the National Electric Code, ANSI/NFPA 70, Article 504 and 505. For additional information refer to ANSI/ISA RP12.6. This module, 1797-IE8, must be used with terminal base 1797-TB3 or 1797-TB3S. Terminals 3, 7, 11, 15, 20, 24, 28, 32, 36-39, and 46-49 shall not be connected. WARNING: Substitution of components may impair intrinsic safety.