Components for safety applications

Similar documents
TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Pendant control stations 6

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Electromechanical pressure and vacuum switches 0

Characteristics 5 TeSys k contactors and reversing contactors

Modular equipment. Presentation, standards. Standard contactors TeSys GC

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Pendant control stations 6

Components for safety applications Preventa safety modules

Pendant control stations 6

3 - Protection components Circuit-breakers

Safety switches with slotted hole lever

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Motor starters. TeSys E. Designed for the essential

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

NS..S contactor relays - with spring terminals AC operated

Datasheet - PROTECT-IE-02

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Control module CP-A CM

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Type CP-S, CP-C & CP-A Switch mode

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Datasheet - ZQ N

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

LR Position Switches TECHNICAL DATASHEET

Electronic Step Controller

Position switches FM series

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

FM series position switches

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Protection components

Type Nominal voltage (V) Code HSV V

Operating instructions Fail-safe delay timer AZS About this document. Content

Zelio Plug-In Relays. RXG interface relays. Catalog

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Control Stations ø 22

New Products Catalogue 2009 Safety Relays ESR5

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

02/11/2015

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Zelio Control Measurement Relays

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Complete units: Mushroom heads ø 22mm

Complete units: Push-buttons ø 22mm

E-STOP relays, safety gate monitors

02/11/2015

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DISCONNECT SWITCHES. UL Listed CSA Certified

Motor Protection Circuit Breaker Series 8146/5-V27

Description Basic devices with positive operation contacts

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Custom "Compact" range with display CD20 Custom Part number

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

(1,5 modules per pole)

Classification Enclosure rating Contact form Contact material

Series P. Applications

Complete units: Selector switches ø 22mm

RENF22R2MMW Zelio Timer Relay - Modular

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Protection components

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

Solid-state Timer H3DS

Operator Heads: ø 22mm

Controls Contactors and Contactor Assemblies Special Applications

Operator Heads: ø 22mm

SINEAX B 811 Power Pack with additional Functions

Transcription:

Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages /18, /19, /16, /17, /1 Double insulated, types CS-PA, CS-TA, CS-TE Switches with or without locking of the actuator Pages /30, /31, /8, /9, /3, / / Te

Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE General characteristics Environment Limit switch type CS-A, CS-C, CS-E (metal case) CS-PA, CS-TA, CS-TE (double insulated case) Conforming Products IEC 947-5-1, EN 60 947-5-1, UL 508, CSA C- n, JIS C450 to standards Machine assemblies IEC 04-1, EN 60 04-1, EN 1088, EN 9 Product certifications UL, CSA, BG UL, CSA, BG (pending) Protective treatment Standard version : TC Ambient air temperature Operation : - 5 + 70 C (- 5 + 40 C for CS-E and - 5 + 60 C for CS-TE) Storage : - 40 + 70 C Vibration resistance 5 gn (10 500 Hz) conforming to IEC 68--6 Shock resistance 10 gn (duration 11 ms) conforming to IEC 68--7 Electric shock protection Class I conforming to IEC 536 Class conforming to IEC 536 Degree of protection IP 67 conforming to IEC 59 (1) and IEC 947-5-1 Cable entry 1 entry (CS-A and CS-E) or entries 1 entry (CS-PA and CS-TE) or entries (CS-TA) tapped for Pg 11 (Country specific references) (CS-E) tapped for Pg.5 (n ) cable (n 11) cable gland, tapped M16 or tapped 1/" NPT (with adaptor) for gland, tapped M0 or tapped 1/" NPT CS-TA and CS-TE Contact block characteristics Rated operational characteristics Rated thermal current in enclosure CS-A, CS-C, CS-PA, CS-TA : c AC-15, A300 : Ue = 40 V, Ie = 3 A or Ue = 10 V, Ie = 6 A CS-E, CS-TE : c AC-15, B300 : Ue = 40 V, Ie = 1.5 A or Ue = 10 V, Ie = 3 A All models : a DC-, Q300 : Ue = 50 V, Ie = 0.7 A or Ue = 15 V, Ie = 0.54 A conforming to IEC 947-5-1, EN 60 947-5-1 CS-A, CS-C, CS-PA, CS-TA : Ithe = 10 A CS-E, CS-TE : Ithe = 6 A Rated insulation voltage Ui = 500 V conforming to IEC 947-5-1 Ui = 300 V conforming to UL 508, CSA C- n Rated impulse withstand voltage CS-A, CS-C, CS-PA, CS-TA : Uimp = 6 kv conforming to IEC 947-5-1 CS-E, CS-TE : Uimp = 4 kv conforming to IEC 947-5-1 Positive operation N/C contact with positive opening operation conforming to IEC 947-5-1 Section 3, EN 60 947-5-1 Resistance across terminals 30 mω conforming to IEC 957-5-4 Short-circuit protection Cabling 10 A cartridge fuse type gg (gl) Screw clamp terminals. Clamping capacity, min. : 1 x 0.5 mm, max. : x 1.5 mm with or without cable end Electrical durability Conforming to IEC 947-5-1 Appendix C. Utilisation categories AC-15 and DC-. Maximum operating rate : 3600 operating cycles per hour. Load factor : 0.5 a.c. supply c 50/60 Hz p inductive circuit Millions of operating cycles 1 0,5 0, 30 V 1/4/48 V 110 V 0,1 0,5 1 3 4 5 10 Current in A d.c. supply a Power broken in W for 1 million operating cycles Voltage V 4 48 10 p W 9 7 (1) Live parts of the switches are protected against the penetration of dust and water. However, when installing take all necessary precautions to prevent the penetration of solid bodies, or liquids with a high dust content, into the actuator aperture. Not recommended for use in saline atmospheres. Te /15

pages /3 and /4 page /5 Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped M0 x 1.5 References, characteristics Type of switch Without locking of actuator With locking, manual unlocking () LED indication on opening Without 1 orange LED 1 orange LED Without 1 orange LED 1 orange LED of N/C contacts c or a 4/48 V c 110/40 V c or a 4/48 V c 110/40 V References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-A50 CS-A51 CS-A5 CS-C50 CS-C51 CS-C5 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-A70 CS-A71 CS-A7 CS-C70 CS-C71 CS-C7 (N/O staggered) 3-pole N/C + N/C + N/C CS-A80 CS-C80 Weight (kg) 0.440 0.440 0.440 0.480 0.480 0.480 Complementary characteristics not shown under general characteristics (page /15) Actuation speed Resistance to forcible withdrawal of actuator Mechanical durability Maximum operating rate Minimum force for positive opening Cable entry References of actuators Maximum : 0.5 m/s, minimum : 0.01 m/s CS-C : > 1500 N ; CS-E : 000 N > 1 million operating cycles For maximum durability : 600 operating cycles per hour 0 N CS-A, CS-C : 1 cable entry. CS-E : cable entries. Entries tapped M0 x 1.5 for ISO cable gland. Clamping capacity 7 to mm. (Padlock in open position) Description Straight actuator Wide actuator Pivoting actuator Latch for sliding doors For guard switches CS-A, C, E CS-Z01 CS-Z0 CS-Z03 CS-Z05 Weight (kg) 0.01 0.01 0.095 0.600 (1) Adjustable throughout 360 in 90 steps. Blanking plug for operating head slot included with switch. () Unlocking by key operated lock. (3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. /16 Te

pages /3 and /4 pages /5 to /7 Type of switch Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped M0 x 1.5 References, characteristics With interlocking, locking by solenoid Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a limit switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number (3) by 5 in the references shown below. Example : CS-E531 becomes CS-E551. LED indication Orange LED : guard open signalling. Green LED : guard closed and locked signalling. Supply voltage of solenoid c or a 4 V c or a 48 V c or a 110/10 V (3) c or a 0/40 V (3) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-E531 CS-E53 CS-E5 CS-E534 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-E731 CS-E73 CS-E7 CS-E734 (N/O staggered) 3-pole N/C + N/C + N/C CS-E831 (5) CS-E83 (5) CS-E8 (5) CS-E834 (5) Weight (kg) 1.0 1.0 1.0 1.0 Solenoid characteristics Load factor 100 % Rated operational voltage c or a 4 V c or a 48 V c or a 110/10 V c or a 0/40 V Voltage limits - 0 %, + 10 % of the rated operational voltage (including ripple on a) conforming to IEC 947-1 Service life 0,000 hours Consumption LED indicator characteristics Inrush : 10 VA. Sealed : 10 VA Rated insulation voltage 50 V conforming to IEC 947-1 50 V conforming to IEC 947-1 Current consumption 7 ma 7 ma Rated operational voltage c or a 4/48 V c 110/40 V Voltage limits c or a 0...5 V (including ripple on a) c 95...64 V (including ripple on a) Service life 100,000 hours 100,000 hours Protection against overvoltages Yes Yes (1) Adjustable throughout 360 in 90 steps. () A key operated lock enables the forced opening of the interlocking mechanism by authorised personnel, allowing key withdrawal and subsequent opening of the N/C safety contacts. (3) For use on a 110/10 V or a 0/40 V, remove the LED indicator module. (4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. (5) Units supplied with a single green LED. Te /17

pages /3 and /4 page /5 Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped for Pg.5 (n ) cable gland References, characteristics Type of switch Without locking of actuator With locking, manual unlocking () For UK market, please refer to pages /16 and /17 LED indication on opening Without 1 orange LED 1 orange LED Without 1 orange LED 1 orange LED of N/C contacts c or a 4/48 V c 110/40 V c or a 4/48 V c 110/40 V References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-A501 CS-A511 CS-A51 CS-C501 CS-C511 CS-C51 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-A701 CS-A711 CS-A71 CS-C701 CS-C711 CS-C71 (N/O staggered) 3-pole N/C + N/C + N/C CS-A801 CS-C801 Weight (kg) 0.440 0.440 0.440 0.480 0.480 0.480 Complementary characteristics not shown under general characteristics (page /15) Actuation speed Resistance to forcible withdrawal of actuator Mechanical durability Maximum operating rate Minimum force for positive opening Cable entry References of actuators Maximum : 0.5 m/s, minimum : 0.01 m/s CS-C : > 1500 N ; CS-E : 000 N > 1 million operating cycles For maximum durability : 600 operating cycles per hour 0 N CS-A, CS-C : 1 cable entry. CS-E : cable entries. Entries tapped for n cable gland conforming to NF C 68-300 (DIN Pg.5). Clamping capacity 9 to 1 mm. Latch for sliding doors Description Straight actuator Wide actuator Pivoting actuator (Padlock in open position) For guard switches CS-A, C, E CS-Z01 CS-Z0 CS-Z03 CS-Z05 Weight (kg) 0.01 0.01 0.095 0.600 (1) Adjustable throughout 360 in 90 steps. Blanking plug for operating head slot included with switch. () Unlocking by key operated lock. (3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. /18 Te

pages /3 and /4 pages /5 to /7 Type of switch Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped for Pg.5 (n ) cable gland References, characteristics With interlocking, locking by solenoid For UK market, please refer to pages /16 and /17 Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a limit switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number (3) by 5 in the references shown below. Example : CS-E5311 becomes CS-E5511. LED indication Orange LED : guard open signalling. Green LED : guard closed and locked signalling. Supply voltage of electromagnet c or a 4 V c or a 48 V c or a 110/10 V (3) c or a 0/40 V (3) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-E5311 CS-E531 CS-E51 CS-E5341 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-E7311 CS-E731 CS-E71 CS-E7341 (N/O staggered) 3-pole N/C + N/C + N/C CS-E8311 (5) CS-E831 (5) CS-E81 (5) CS-E8341 (5) Weight (kg) 1.0 1.0 1.0 1.0 Solenoid characteristics Load factor 100 % Rated operational voltage c or a 4 V c or a 48 V c or a 110/10 V c or a 0/40 V Voltage limits - 0 %, + 10 % of the rated operational voltage (including ripple on a) conforming to IEC 947-1 Service life 0,000 hours Consumption LED indicator characteristics Inrush : 10 VA. Sealed : 10 VA Rated insulation voltage 50 V conforming to IEC 947-1 50 V conforming to IEC 947-1 Current consumption 7 ma 7 ma Rated operational voltage c or a 4/48 V c 110/40 V Voltage limits c or a 0...5 V (including ripple on a) c 95...64 V (including ripple on a) Service life 100,000 hours 100,000 hours Protection against overvoltages Yes Yes (1) Adjustable throughout 360 in 90 steps. () A key operated lock enables the forced opening of the interlocking mechanism by autorised personnel, allowing withdrawal of actuator and subsequent opening of the N/C safety contacts. (3) For use on a 110/10 V or a 0/40 V, remove the LED indicator module. (4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. (5) Units supplied with a single green LED. Te /19

pages /3 and /4 page /5 Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped 1/" NPT References, characteristics Type of switch Without locking of actuator With locking, manual unlocking () For UK market, please refer to pages /16 and /17 LED indication on opening Without 1 orange LED 1 orange LED Without 1 orange LED 1 orange LED of N/C contacts c or a 4/48 V c 110/40 V c or a 4/48 V c 110/40 V References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-A503 CS-A5 CS-A53 CS-C503 CS-C5 CS-C53 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-A703 CS-A7 CS-A73 CS-C703 CS-C7 CS-C73 (N/O staggered) 3-pole N/C + N/C + N/C CS-A803 CS-C803 Weight (kg) 0.440 0.440 0.440 0.480 0.480 0.480 Complementary characteristics not shown under general characteristics (page /15) Actuation speed Resistance to forcible withdrawal of the actuator Mechanical durability Maximum operating rate Minimum force for positive opening Cable entry References of actuators Maximum : 0.5 m/s, minimum : 0.01 m/s CS-C : > 1500 N ; CS-E : 000 N > 1 million operating cycles For maximum durability : 600 operating cycles per hour 0 N CS-A, CS-C : 1 cable entry. CS-E : cable entries. Entries tapped for 1/" NPT (USAS B-1) conduit. (Padlock in open position) Description Straight actuator Wide actuator Pivoting actuator Latch for sliding doors For guard switches CS-A, C, E CS-Z01 CS-Z0 CS-Z03 CS-Z05 Weight (kg) 0.01 0.01 0.095 0.600 (1) Adjustable throughout 360 in 90 steps. Blanking plug for operating head slot included with switch. () Unlocking by key operated lock. (3) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. /0 Te

pages /3 and /4 pages /5 to /7 Type of switch Metal, turret head (1), types CS-A, CS-C and CS-E Cable entries tapped 1/" NPT References, characteristics With interlocking, locking by solenoid For UK market, please refer to pages /16 and /17 Type of interlocking Locking on de-energisation and unlocking on energisation of solenoid (). To order a limit switch with locking on energisation and unlocking on de-energisation of the solenoid, replace the nd number (3) by 5 in the references shown below. Example : CS-E53 becomes CS-E55. LED indication Orange LED : guard open signalling. Green LED : guard closed and locked signalling. Supply voltage of solenoid c or a 4 V c or a 48 V c or a 110/10 V (3) c or a 0/40 V (3) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) (50/60 Hz on c) References of switches without actuator ( N/C contact with positive opening operation) 1 11 3-pole N/C + N/O + N/O CS-E53 CS-E5 CS-E53 CS-E5343 ( N/O staggered) 3 31 3 31 34 3-pole N/C + N/C + N/O CS-E73 CS-E7 CS-E73 CS-E7343 (N/O staggered) 3-pole N/C + N/C + N/C CS-E83 (5) CS-E8 (5) CS-E83 (5) CS-E8343 (5) Weight (kg) 1.0 1.0 1.0 1.0 Solenoid characteristics Load factor 100 % Rated operational voltage c or a 4 V c or a 48 V c or a 110/10 V c or a 0/40 V Voltage limits - 0 %, + 10 % of the rated operational voltage (including ripple on a) conforming to IEC 947-1 Service life 0,000 hours Consumption LED indicator characteristics Inrush : 10 VA. Sealed : 10 VA Rated insulation voltage 50 V conforming to IEC 947-1 50 V conforming to IEC 947-1 Current consumption 7 ma 7 ma Rated operational voltage c or a 4/48 V c110/40 V Voltage limits c or a 0...5 V (including ripple on a) c 95/64 V (including ripple on a) Service life 100,000 hours 100,000 hours Protection against overvoltages Yes Yes (1) Adjustable throughout 360 in 90 steps. () A key operated lock enables the forced opening of the interlocking mechanism by authorised personnel, allowing key withdrawal and subsequent opening of the N/C safety contacts. (3) For use on a 110/10 V or a 0/40 V, remove the LED indicator module. (4) Schematic diagrams shown represent the contact states whilst the actuator is inserted in the head of the switch. (5) Units supplied with a single green LED. Te /1

Metal, turret head, types CS-A, CS-C and CS-E pages /3 and /4 pages /5 to /7 References of spare parts CS-Z3i Spare parts Description For use Supply voltage Reference Weight with kg 1 orange LED indicator CS-A c or a 4/48 V CS-Z31 0.040 module with cover, CS-C seal and fixing screws c 110/40 V CS-Z3 0.040 1 orange LED + 1 green CS-E53ii c or a 4/48 V CS-Z41 0.175 LED indicator module with cover + lock (1), c 110/40 V CS-Z45 0.175 seal and 4 fixing screws (lock supplied with keys) CS-E55ii c or a 4/48 V CS-Z4 0.175 c 110/40 V CS-Z46 0.175 CS-E73ii c or a 4/48 V CS-Z43 0.175 c 110/40 V CS-Z47 0.175 CS-Z4i CS-Z5i CS-Z6i CS-E75ii c or a 4/48 V CS-Z44 0.175 c 110/40 V CS-Z48 0.175 Description For use Positions of key Reference Weight with withdrawal from lock kg Cover + lock CS-E53ii LOCK : yes/unlock : yes CS-Z51 0.05 with seal and 4 fixing screws (lock supplied with keys) LOCK : yes/unlock : no CS-Z55 0.05 LOCK : no/unlock : yes CS-Z59 0.05 CS-E55ii LOCK : yes/unlock : yes CS-Z5 0.05 LOCK : yes/unlock : no CS-Z56 0.05 LOCK : no/unlock : yes CS-Z60 0.05 CS-E73ii LOCK : yes/unlock : yes CS-Z53 0.05 LOCK : yes/unlock : no CS-Z57 0.05 LOCK : no/unlock : yes CS-Z61 0.05 CS-E75ii LOCK : yes/unlock : yes CS-Z54 0.05 LOCK : yes/unlock : no CS-Z58 0.05 LOCK : no/unlock : yes CS-Z6 0.05 CS-E83ii LOCK : yes/unlock : yes CS-Z63 0.05 LOCK : yes/unlock : no CS-Z64 0.05 LOCK : no/unlock : yes CS-Z65 0.05 CS-E85ii LOCK : yes/unlock : yes CS-Z66 0.05 LOCK : yes/unlock : no CS-Z67 0.05 LOCK : no/unlock : yes CS-Z68 0.05 Set of 10 blanking CS-A, CS-Z7 0.050 plugs for operating CS-C, head slot CS-E / Te Set of 10 pairs of CS-C, CS-Z5 0.100 keys for interlock CS-E forced opening device (1) Lock supplied as standard with CS-E switches : key withdrawal in LOCK and UNLOCK positions.

Metal, turret head, types CS-A, CS-C and CS-E References : pages /18 to /1 pages /5 to /7 Dimensions CS-Aiii CS-Ciii 7 37 7 5 38 1,5 60 43,5 x Ø 5,3 38 1,5 60 43,5 8,5 x Ø 5,3 (1) 44 16 = 30 = 40 Ø (1) 44 16 = 30 = 40 Ø (1) 1 tapped entry for cable gland (1) 1 tapped entry for cable gland Ø : elongated holes Ø 7.3 x 5.3 Ø : elongated holes Ø 7.3 x 5.3 CS-Eiiii 48 7 3,5 38 Ø 43,5 (1) 6 6 1 95 1 xø5,3 6 44 16 = 88 = 98 (1) 1 tapped entry for cable gland Ø : elongated holes Ø 7.3 x 5.3 Te /3

Metal, turret head, types CS-A, CS-C and CS-E Dimensions Dimensions CS-Z01 Adaptor shank (1) CS-Z0 81,5,5 35 3,5 55,5 11 5 Ø = = 15 Ø = = == 35 = 5 51 0 11 0 7,5 = Ø,5 (1) Adaptor (supplied with actuator CS-Z01) for replacing, without drilling additional fixing hole, an CK-J safety limit switch with actuator ZCK-Y07 by an CS-A, C or E safety limit switch with actuator CS-Z01 Ø : elongated holes Ø 5.3 x 10 Ø : elongated holes Ø 5.3 x 10 CS-Z03 CS-Z05,5 76 30 48 40 41 Ø 6 7 30 4 1,5 115 64 7 10 Ø5,3,5 11 5 30 10 5 17 3 40 3 0 18 0 6 0 4xM5 100 0 Ø10 6 Ø : 4 elongated holes Ø 5.3 x 7.3 Operating radius required for actuator CS-Z01 CS-Z0 R min. : 000 R min. : 000 R min. : 000 R min. : 000 CS-Z03 55 R min. :150 16,5 R min. : 400 /4 Te

Metal, turret head, types CS-A, CS-C and CS-E References : pages /18 to /1 pages /3 and /4 Setting-up, schemes Setting-up Function diagrams CS-i5iii CS-i7iii CS-i8iii Contact operation contact closed contact open unstable 31 5 3,5 1 1- - -34 31 5 3 1,5 1-31-3-5 3 31 11-1 1-31-3 Schemes Note : These schemes are given as examples only, the designer must refer to the relevant safety standards for guidance. Wiring to category 1 (EN 954-1) Wiring to category 3 (EN 954-1) Example with 3-pole N/C + N/O + N/O contact and protection Example with 3-pole N/C + N/C + N/O contact without monitoring. fuse to prevent shunting of the N/C contact, either by cable (The guard switch should be used in conjunction with a safety limit switch to give damage or by unauthorised tampering. mechanical/electrical redundancy) F1 F1 34 34 O (1) (1) O I I M M (1) Signalling contact (1) Signalling contact Wiring to category 4 (EN 954-1). Wiring method used in conjunction with PREVENTA safety module. (The guard switch should be used in conjunction with a safety limit switch to give electrical/mechanical redundancy) Method for machines with quick rundown time (low inertia) Locking or interlocking mechanism uses the principles of redundancy and autocheck.the safety modules ensure these functions. Method for machines with long rundown time (high inertia) PS-FB PS-VN PS-FB Locking by actuator and operation in positive Interlocking mechanism with actuator captive mode associated with a safety module. in the guard and zero speed detection. See page 1/9. See page 1/9. Te /5

with solenoid interlocking Metal, turret head, type CS-E References : pages /18 to /1 pages /3 and /4 Schemes Wiring to category 1 (EN 954-1) Wiring examples with protection fuse to prevent shunting of the N/C contact, either by cable damage or by unauthorised tampering. Locking on de-energisation N/C + N/O + N/O CS-E53i3 Locking on energisation N/C + N/O + N/O CS-E55i3 F1 F1 1 1 (1) () 51 5 34 (1) () 51 5 34 E1 E 43 44 3 OG GN E1 E 43 44 3 OG GN 1 1 O O I I M M (1) Solenoid (1) Solenoid () Auxiliary contact () Auxiliary contact E1-E : Solenoid supply E1-E : Solenoid supply 43-44 : Solenoid signalling contact 51-5 : Solenoid signalling contact - : Safety contact, available for redundancy - : Safety contact, available for redundancy -1 : LED (orange) : actuator withdrawn -1 : LED (orange) : actuator withdrawn 51-1 : LED (green) : actuator inserted and locked 43-1 : LED (green) : actuator inserted and locked Note : these schemes are given as examples only, the designer must refer to EN 954-1 for guidance. The risk assessment (EN 1050) will help the designer to determine the most appropriate risk reduction methods and the part played by the safety related parts of the control system in reducing the risk. /6 Te

with solenoid interlocking Metal, turret head, type CS-E References : pages /18 to /1 pages /3 and /4 Schemes Wiring to category 3 (EN 954-1) Wiring examples with redundancy for the guard switch contacts, without monitoring or redundancy in the power circuit. Locking on de-energisation N/C + N/C + N/O CS-E73i3 Locking on energisation N/C + N/C + N/O CS-E75i3 F1 F1 F F (1) () 51 5 1 31 3 K1 K (1) () 51 5 1 31 3 K1 K E1 E 43 44 3 OG 1 GN O I KM E1 E 43 44 3 OG 1 GN O I KM K1 K KM K1 K KM M M (1) Solenoid (1) Solenoid () Auxiliary contact () Auxiliary contact E1-E : Solenoid supply E1-E : Solenoid supply 43-44 : Solenoid signalling contact 51-5 : Solenoid signalling contact 31-3 : Safety contact, available for redundancy 31-3 : Safety contact, available for redundancy -1 : LED (orange) : actuator withdrawn -1 : LED (orange) : actuator withdrawn 51-1 : LED (green) : actuator inserted and locked 43-1 : LED (green) : actuator inserted and locked Note : these schemes are given as examples only, the designer must refer to EN 954-1 for guidance. The risk assessment (EN 1050) will help the designer to determine the most appropriate risk reduction methods and the part played by the safety related parts of the control system in reducing the risk. For further information, please consult your local Customer support centre. Te /7