HAZARDOUS AREA SOLUTIONS

Similar documents
HAZARDOUS AREA SOLUTIONS

iant101 Zone 1 Omni Directional Antenna

Installation & Operating Manual. iwap202

Signal Beacon - LED Series 6162

4 Applications. 10 Universal Multi Vendor Wireless Network Solutions. 19 Extronics Wireless Network Solutions. 41 Antennas and Surge Arrestors

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Operating Manual. isolate501

Coriolis Massflowmeter

INSTRUCTION MANUAL (ATEX / IECEx)

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Local control stations for Zone 1 and Zone 21. Features. Description

EVLS Hazard Gard. Compact & Rugged, Explosionproof Luminaire. High-Pressure Sodium Metal Halide Pulse Start Metal Halide

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Hazardous environments

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

For use in Flammable Gas and Dust Atmospheres

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Flow Measurement SITRANS F M

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

SALES SERVICE +358 (0)

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Coriolis Mass Flow Meter Model TM

Electrical Temperature Measurement

Condumax CLS21 and CLS21D

HAZARDOUS LOCATIONS TELEMETRY EQUIPMENT COMPONENTS CATALOGUE ACCESSORIES

Safety in Hazardous Environments

Baymaster HL LED Luminaire High Bay for Hazardous Locations

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

IN-BUILDING ANTENNAS

Coriolis Massflowmeter

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Description of equipment

MA600.A B C MA600 Spartan Screw-mount 3in1 Combination Antenna GPS Cellular GSM/CDMA/HSPA/UMTS 2.4GHz / 5GHz

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Target disk flowmeter for liquids and gases

Specification. Hercules MA520.A.BC.008

SPECIFICATION. MIMO Dual Band 2.4/5.0GHz. ISM Bands/ZigBee/WLAN/Bluetooth. IEEE n/IEEE ac. High Isolation between Antenna Elements

SPECIFICATION. 3in1 Combination Antenna. GPS/GLONASS/GALILEO 1575~1602MHz. Cellular GSM/CDMA/HSPA/UMTS. Dual band Wi-Fi 2.4GHz / 5.

Baymaster LED Luminaire High Bay for Hazardous Locations

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Technical Information Condumax CLS21D/CLS21

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

ED701 General Industry Pressure Transmitter

J: Emergency lighting (optional) L: pole type X: ceiling type

BExCS / BExDCS110-05

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 7300 C Supplementary instructions

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Relative and absolute pressure transmitter type 528

Field indicator for current loops with HART communication Models DIH50, DIH52

WaveNet. Wireless Monitoring.

SPECIFICATION. Product Name : Heavy Duty Screw Mount Antenna MIMO Dual Band 2.4/5.0GHz

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

General Specifications

Resistance Thermometers Model Series TR7X0, Sheathed Design

K-BAND RADAR FOR LIQUIDS

VITO LT. Global Experience. Locally Applied. A dependable choice.

IP26 Series Current to Pneumatic Converter

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

Technical Data. General specifications. Rated operating distance s n 3 mm

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

Mongoose PT Platform Shale Shaker

Biofilm Monitoring System. Catalog.

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Specification. Spartan MA605.A.ABC in1 MA.605 Low Profile Screw-Mount (Permanent Mount) GPS/GLONASS/Cellular/2.4GHz ~ 5GHz Combination Antenna

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Explosion proof rotary actuator - On/Off or programmable regulating actuator

TMU. Coriolis Mass Flow Meter. for liquids and gas

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

SPECIFICATION. SPE /D/AS Page 1 of 24 MA.520.C.B C Part No. : MA520.A.BC.008

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

The Rosemount 848T Wireless Temperature Transmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

PRODUCT CATALOG. RF Test. VIAVI Solutions. Antennas

Level Measurement Continuous level measurement Radar transmitters

Condumax CLS21 and CLS21D

Installation guide 971 SmartRadar LTi

HyperLink Wireless 2.4/ 5 GHz Dual Band / Dual Polarized Omni Antenna Model: HG DPU

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Condumax CLS15 and CLS15D

Position switches FM series

Float Switches with Permanent Magnet For Vertical Installation Model RSM

AirLink Antenna: 6-in-1 SharkFin

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Transcription:

HAZARDOUS AREA SOLUTIONS WIRELESS & Systems ATEX IP66 Zones 1 and 2 v. 1.1/16

2 Delvalle, wide experience in manufacturing solutions for hazardous area We put at your disposal We offer over 40 years providing solutions to demanding customers who require very specific characteristics and behaviour according to the sector and their needs. wherever you go We are committed to working closely with our customers, providing them with exceptional service and offering an advanced and extensive range of products with very competitive prices. customize your WiFi SYSTEM - WIRELESS high standard of quality and services We only use materials provided by companies who offer the very highest quality, suitable and certified products. Our success is due to top quality assurance: ISO 9001, SGS, UL, TÜV, ISO 14000 and Ohsas 18001. ATEX, IECEx a nivel mundial. ALWAYS THINKING OUTSIDE THE BOX Contact us Confidentiality, reliability & quality ALSO ONLINE A team of professionals with high experience and ability to solve all your queries.

3 WIRELESS & Systems ATEX INDEX Bespoke Acess point WIRELESS ATEX & IECEx...4 Hazardous Access Point Wi-Fi ATEX & IECEx...11 Ex ANTENNA ATEX 450-470MHz NPT...18 Ex ANTENNA ATEX GPS 1575MHz NPT...21 Ex ANTENNA ATEX SAT 1600MHz NPT...24 Ex ANTENNAS ATEX GPRS DUAL 880-915MHz & 1710-1785MHz 824-896MHz & 1850-1990MHz 801-949MHz & 1901-2000MHz NPT...27 Ex ANTENNAS ATEX Wi-Fi 915MHz NPT...30

4 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 1. Select the size of the box: FLAMEPROOF ENCLOSURE 364x284x218. FLAMEPROOF ENCLOSURE EJB 432x332x229. FLAMEPROOF ENCLOSURE EJB 567x387x248. 2. Add the nº (1, 2, 4,...) and type of antennas: Ex ANTENNA WIFI 915MHz 3/4NPT. Ex ANTENNA WIFI 2.4GHz 3/4NPT. Ex ANTENNA WIFI DUAL 2.4&5GHz. Ex ANTENNA WIFI 5GHz 3/4NPT. Ex ANTENNA 450-470MHz 3/4NPT Ex ANTENNA GPS 1575MHz 3/4NPT Ex ANTENNA GPRS DUAL 880 & 1710MHz Ex ANTENNA GPRS DUAL 801 & 1901MHz Ex ANTENNA GPRS DUAL 824 & 1850MHz ANTENNA SAT 1600MHz 3/4NPT Custom BESPOKE ACESS POINT WIRELESS ATEX Personalice 3. Delvalle gives the entire project and certified atex

5 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 Example 2 antenas Example 4 antenas Example 4 antennas with window Ex WIRELESS configurable system is designed to allow the deployment of wireless networks in hazardous areas, for indoor as for outdoor, with an IP 66 degree of tightness. It also allows the installation from leading WLAN equipment providers (Cisco, Aeroscout, Motorola, Aruba and others). This system has Ex antennas IECEx with an extended spectrum of frequencies depending the selected model. This Ex antenna is mounted over an Ex flameproof enclosure made from aluminium alloy with cable glands (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). On the other hand, the Ex antenna is omnidirectional with 0.0 or 2.0 dbi gain depending of the selected model, and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. SAT 1600MHz GPRS DUAL 824&1850MHz GPRS DUAL 801&1901MHz GPRS DUAL 880 & 1710MHz 450MHz- 470MHz We offer you the most powerful security GPS 1575MHz 915MHz 2.4GHz 2,4GHz & 5GHz 5GHz

6 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 SECTORS Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power NORMATIVE CENELEC EN 60079-0: 2009 EN 60079-1: 2007 EN 60079-31: 2009 EN 60439-1 EUROPEAN DIRECTIVE 94/9/EC: 1994 IECEx

7 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 REFERENCE (Example of a wireless access point with box 432x332x229, 4 antennas 2.4GHz, and with 2 cable glands NPT type) APEx22 b 4 N 2 Number of cable glands. (Type of cable glands NPT) Number of antennas Antenna ATEX IECEx: a: Ex ANTENNA WIFI 915MHz 3/4NPT - Ref. ANTEx915NPT.W b: Ex ANTENNA WIFI 2.4GHz 3/4NPT - Ref. ANTEx2400NPT.W c: Ex ANTENNA WIFI DUAL 2.4&5GHz - Ref. ANTEx2400-5000NPT.W d: Ex ANTENNA WIFI 5GHz 3/4NPT - Ref. ANTEx5000NPT.W e: Ex ANTENNA 450-470MHz 3/4NPT - Ref. ANTEx450NPT f: Ex ANTENNA GPS 1575MHz 3/4NPT - Ref. ANTEx1575NPT g: Ex ANTENNA GPRS DUAL 824&1850MHz - Ref. ANTEx824-1850NPT h: Ex ANTENNA GPRS DUAL 801&1901MHz - Ref. ANTEx801-1901NPT i: Ex ANTENNA GPRS DUAL 880&1710MHz - Ref. ANTEx880-1710NPT j: ExANTENNA SAT 1600MHz 3/4NPT - Ref. ANTEx1600NPT MARKING Box type: 21: FLAMEPROOF ENCLOSURE EJB 364x284x218. Ref. EJB362821N 22: FLAMEPROOF ENCLOSURE EJB 432x332x229. Ref. EJB362822N 24: FLAMEPROOF ENCLOSURE EJB 567x387x248. Ref. EJB362824N 21T: FLAMEPROOF ENCLOSURE EJB 364x284x218. With central methacrylate window. Ref. EJB362821NT 22T: FLAMEPROOF ENCLOSURE EJB 432x332x229. With central methacrylate window. Ref. EJB433322NT 29T: FLAMEPROOF ENCLOSURE EJB 560x380x298. With central methacrylate window. Ref. EJB563829NT Enclosure marking: ATEX Marking: Ex d IIB+H2 T5 Gb Ambient Temperature: -50/+55 ºC. Antenna marking: Ex d IIB T5 Ambient Temperature: -40º to 85ºC. Option: UL Marking: Class I Div 1, Groups C, D..

8 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 Box Technical Data Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2. TECHNICAL SPECIFICATIONS (without window) L2 L1 REFERENCES Description A B C a b c s s1 d e f D E F L1 L2 EJB362821N EJB433322N FLAMEPROOF ENCLOSURE EJB 364x284x218 FLAMEPROOF ENCLOSURE EJB 432x332x229 weight (kg) 364 284 218 300 220 153 24 14 290 210 M8 290 290 9 403,9 490,4 16,2 432 332 229 360 260 163 24 14 350 250 M10 350 330 11 451,9 538,4 21,4 EJB563824N FLAMEPROOF ENCLOSURE EJB 567x387x248 567 387 248 490 305 160 13 14 360 236 M10 360 356 11 506,9 593,4 33,1

9 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 TECHNICAL SPECIFICATIONS (with window) REFERENCES Description A B C a b c H Window EJB362821NT EJB433322NT EJB563824NT FLAMEPROOF ENCLOSURE EJB 364x284x218 WITH WINDOW FLAMEPROOF ENCLOSURE EJB 432x332x229 WITH WINDOW FLAMEPROOF ENCLOSURE EJB 560x380x298 WITH WINDOW L (antennas in a one side) L (antennas in both sides) 364 284 218 300 220 149 15 150x200 403,9 490,4 432 332 229 432 332 229 15 200x300 451,9 538,4 560 380 298 490 305 229 15 200x300 499,9 586,4

10 BESPOKE ACESS POINT WIRELESS ATEX & IECEx IP66 Zones 1 and 2 SPECIFICATIONS ANTENNA General antenna specifications: Impedance: 50 Ω Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC conn: 5.85, 148.6mm 1575MHz example 2.4GHz Zones: 1-2 Individual specifications of each antenna: REFERENCE DescripTION FreQuencY (MHz) GAIN (dbi) ANTEx915NPT.W Ex ANTENNA WIFI 915MHz 3/4NPT 915 2.0 ANTEx2400NPT.W Ex ANTENNA WIFI 2.4GHz 3/4NPT 2400 2.0 ANTEx2400-5000NPT.W Ex ANTENA WIFI DUAL 2.4&5GHz 2400 & 5000 2.0 ANTEx5000NPT.W Ex ANTENA WIFI 5GHz 3/4NPT 5000 2.0 ANTEx450NPT Ex ANTENA 450-470MHz 3/4NPT 450 470 0.0 ANTEx1575NPT Ex ANTENA GPS 1575MHz 3/4NPT 1575,42 0.0 ANTEx824-1850NPT Ex ANTENA GPRS DUAL 824-896MHz & 1850-1990MHz 824-896 & 1850-1990 2.0 ANTEx801-1901NPT ANTEx880-1710NPT Ex ANTENA GPRS DUAL 801-949MHz & 1901-2000MHz Ex ANTENA GPRS DUAL 880-915MHz & 1710-1785MHz 801-940 & 1901-2000 880-915 & 1710-1785 2.0 2.0 DUAL 801MHz & 1901MHz 450MHz- 470MHz ANTEx1600NPT Ex ANTENA SAT 1600MHz 3/4NPT 1600 2.0

11 Hazardous Acces Point ATEX & IECEx IP66 Zones 1 and 2 Example 4 antennas Example 2 antennas Example 4 antennas with window Ex WIFI access point is designed to allow the deployment of wireless networks in hazardous areas, for indoor as for outdoor, with an IP 66 degree of tightness. It also allows the installation from leading WLAN equipment providers (Cisco, Aeroscout, Motorola, Aruba and others). The access point has four Ex antennas IECEx with an extended spectrum of frequencies depending the selected model. This antenna is mounted over An Ex flameproof enclosure made from aluminium alloy with two cable glands (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). On the other hand, the Ex antenna is omnidirectional with 2.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. 915MHz 2.4GHz 2,4GHz & 5GHz 5GHz We offer you the most powerful security

12 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx SECTORS Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power NORMATIVE CENELEC EN 60079-0: 2009 EN 60079-1: 2007 EN 60079-31: 2009 EN 60439-1 EUROPEAN DIRECTIVE 94/9/EC: 1994 IECEx MARKING Enclosure marking: ATEX Marking: Ex d IIB+H2 T5 Gb Ambient Temperature: -50/+55 ºC. Antenna marking: Ex d IIB T5 Ambient Temperature: -40º to 85ºC. Option: UL Marking: Class I Div 1, Groups C, D.

13 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx a b c d Ex ANTENA WIFI 915MHz 3/4NPT ANTENNA. Ref. ANTEx915NPT.W Ex ANTENA WIFI 2.4GHz 3/4NPT ANTENNA. Ref. ANTEx2400NPT.W Ex ANTENA WIFI DUAL 2.4&5GHz ANTENNAS. Ref. ANTEx2400-5000NPT.W Ex ANTENA WIFI 5GHz 3/4NPT ANTENNAS. Ref. ANTEx5000NPT.W 21 22 24 21T 22T 29T FLAMEPROOF ENCLOSURE EJB 364x284x218. Ref. EJB362821N FLAMEPROOF ENCLOSURE EJB 432x332x229. Ref. EJB362822N FLAMEPROOF ENCLOSURE EJB 567x387x248. Ref. EJB362824N FLAMEPROOF ENCLOSURE EJB 364x284x218. With central methacrylate window. Ref. EJB362821NT FLAMEPROOF ENCLOSURE EJB 432x332x229. With central methacrylate window. Ref. EJB433322NT FLAMEPROOF ENCLOSURE EJB 560x380x298. With central methacrylate window. Ref. EJB563829NT REFERENCES (2 antennas) REFERENCES (4 antennas) REFERENCES High width depth ANTENNA TYPE nº ANTENNAS REFERENCES High width depth ANTENNA TYPE nº ANTENAS WIFIAPEx362821a2 364 284 218 a 2 WIFIAPEx362821b2 364 284 218 b 2 WIFIAPEx362821c2 364 284 218 c 2 WIFIAPEx362821d2 364 284 218 d 2 WIFIAPEx433322a2 432 332 229 a 2 WIFIAPEx433322b2 432 332 229 b 2 WIFIAPEx433322c2 432 332 229 c 2 WIFIAPEx433322d2 432 332 229 d 2 WIFIAPEx563824a2 567 387 248 a 2 WIFIAPEx563824b2 567 387 248 b 2 WIFIAPEx563824c2 567 387 248 c 2 WIFIAPEx563824d2 567 387 248 d 2 WIFIAPEx362821a4 364 284 218 a 4 WIFIAPEx362821b4 364 284 218 b 4 WIFIAPEx362821c4 364 284 218 c 4 WIFIAPEx362821d4 364 284 218 d 4 WIFIAPEx433322a4 432 332 229 a 4 WIFIAPEx433322b4 432 332 229 b 4 WIFIAPEx433322c4 432 332 229 c 4 WIFIAPEx433322d4 432 332 229 d 4 WIFIAPEx563824a4 567 387 248 a 4 WIFIAPEx563824b4 567 387 248 b 4 WIFIAPEx563824c4 567 387 248 c 4 WIFIAPEx563824d4 567 387 248 d 4

14 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx TECHNICAL DATA BOX Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2. TECHNICAL SPECIFICATIONS (Without window) REFERENCES Description A B C a b c s s1 d e f D E F L1 L2 EJB362821N EJB433322N FLAMEPROOF ENCLOSURE EJB 364x284x218 FLAMEPROOF ENCLOSURE EJB 432x332x229 weight (kg) 364 284 218 300 220 153 24 14 290 210 M8 290 290 9 403,9 490,4 16,2 432 332 229 360 260 163 24 14 350 250 M10 350 330 11 451,9 538,4 21,4 EJB563824N FLAMEPROOF ENCLOSURE EJB 567x387x248 567 387 248 490 305 160 13 14 360 236 M10 360 356 11 506,9 593,4 33,1

15 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx TECHNICAL SPECIFICATIONS (2 Antennas with window) REFERENCES Description A B C a b c H Window L EJB362821NT EJB433322NT EJB563829NT FLAMEPROOF ENCLOSURE EJB 364x284x218 With central methacrylate window FLAMEPROOF ENCLOSURE EJB 432x332x229 With central methacrylate window FLAMEPROOF ENCLOSURE EJB 560x380x298 With central methacrylate window 364 284 218 300 220 149 15 150x200 403,9 432 332 229 432 332 229 15 200x300 451,9 560 380 298 490 305 229 15 200x300 499,9

16 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx TECHNICAL SPECIFICATIONS (4 Antennas with window) REFERENCES Description A B C a b c H Window L EJB362821NT EJB433322NT EJB563824NT FLAMEPROOF ENCLOSURE EJB 364x284x218 With central methacrylate window FLAMEPROOF ENCLOSURE EJB 432x332x229 With central methacrylate window FLAMEPROOF ENCLOSURE EJB 560x380x298 With central methacrylate window 364 284 218 300 220 149 15 150x200 490,4 432 332 229 432 332 229 15 200x300 538,4 560 380 298 490 305 229 15 200x300 586,4

17 Hazardous Acces Point IP66 Zones 1 and 2 ATEX & IECEx SPECIFICATIONS ANTENNA General antenna specifications: Impedance: 50 Ω Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC conn: 5.85, 148.6mm Zones: 1-2 915MHz 2.4GHz Individual specifications of each antenna: REFERENCE DESCRIPTION Frequency (MHz) Gain (dbi) ANTEx915NPT.W Ex ANTENA WIFI 915MHz 3/4NPT 915 2.0 ANTEx2400NPT.W Ex ANTENA WIFI 2.4GHz 3/4NPT 2400 2.0 ANTEx2400-5000NPT.W Ex ANTENA WIFI DUAL 2.4&5GHz 2400 & 5000 2.0 ANTEx5000NPT.W Ex ANTENA WIFI 5GHz 3/4NPT 5000 2.0 2.4&5GHz 5GHz

18 Ex ANTENNA ATEX 450-470MHz NPT IP66 Zones 1 and 2 The Ex Radio Antenna system, with an IP66 degree of tightness, includes an Ex antenna, ICECEx 450-470 MHz that can be used in zones 1 and 2. This antenna is mounted over a lightweight and compact enclosure made from aluminium alloy used to adjust the cable, with access through an NPT cable gland (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). 450-470MHz On the other hand, the Ex antenna is omni-directional with 0.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency We offer you the most powerful security Examples

19 Ex Antenna ATEX 450-470MHz NPT IP66 Zones 1 and 2 APPLICATION Hazardous tank level monitoring Wireless bridges Hazardous area computers Utility systems where explosive gases may be present Offshore platforms Power plants Utility systems with the possibility of explosive gases presence. REFERENCE (Example of a box with 5 meter cable) EJBANTEx450_05 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 450-470MHz Ref. ANTEx 450NPT. Box with cable gland. Ref. EJB1389R2.4N3/4 NORMATIVE CENELEC EN 60079-0: 2012 EN 60079-1: 2007 EUROPEAN DIRECTIVE 94/9/EC: 1994 UL, cul listed IECEx Need more information? SECTORS Oil & Gas Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power

20 Ex Antenna ATEX 450-470MHz NPT IP66 Zones 1 and 2 MARKING ATEX Marking: Ex d IIB T5 Gb. UL Marking: Class I Div 1, Groups C, D. Ambient Temperature: -20/+40 ºC. CODE Position of entries Ø Cable EntrY ExterNAL DIMENSIONS (mm) D1 A B Weight (Kg) EJBANTEx450 8/10,5 10,5/13 13/15,5 15,5/18 89 110 130 0,6 SPECIFICATIONS ANTENNA Frequency: 450-470 MHz Impedance: 50 Ω Gain: 2.0 dbi Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC con: 5.85, 148.6mm Zones: 1-2 Box Technical Data Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2.

21 Ex ANTENNA ATEX GPS 1575MHz NPT IP66 Zones 1 and 2 1575MHz The Ex GPS Antenna system, with an IP 66 degree of tightness, includes an Ex antenna, ICECEx, Dual band 1,575.42 MHz that can be used in zones 1 and 2. This antenna is mounted over a lightweight and compact enclosure made from aluminium alloy used to adjust the cable, with access through an NPT cable gland (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). On the other hand, the Ex antenna is omnidirectional with 0.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. We offer you the most powerful security Examples

22 Ex ANTENNA ATEX GPS 1575MHz NPT IP66 Zones 1 and 2 APPLICATION Hazardous tank level monitoring Wireless bridges Hazardous area computers Utility systems where explosive gases may be present Offshore platforms Power plants Utility systems with the possibility of explosive gases presence. REFERENCE (Example of a box with 5 meter cable) EJBANTEx1575_05 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 1575 MHz Ref. ANTEx 1575NPT. Box with cable gland. Ref. EJB1389R2.4N3/4 NORMATIVE CENELEC EN 60079-0: 2012 EN 60079-1: 2007 EUROPEAN DIRECTIVE 94/9/EC: 1994 UL, cul listed IECEx Need more information? SECTORS Oil & Gas Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power

23 Ex ANTENNA ATEX GPS 1575MHz NPT IP66 Zones 1 and 2 MARKING ATEX Marking: Ex d IIB T5 Gb. UL Marking: Class I Div 1, Groups C, D. Ambient Temperature: -20/+40 ºC. CODE Position of entries Ø Cable EntrY ExterNAL DIMENSIONS (mm) D1 A B Weight (Kg) EJBANTEx1575 8/10,5 10,5/13 13/15,5 15,5/18 89 110 130 0,6 SPECIFICATIONS ANTENNA Frequency: 1,575.42 GHz Impedance: 50 Ω Gain: 0.0 dbi Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC con: 5.85, 148.6mm Zones: 1-2 Box Technical Data Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2.

24 Ex ANTENNA ATEX SAT 1600MHz NPT IP66 Zones 1 and 2 The Ex Antenna system, with an IP66 degree of tightness, includes an Ex antenna, ICECEx 1600 MHz that can be used in zones 1 and 2. This antenna is mounted over a lightweight and compact enclosure made from aluminium alloy used to adjust the cable, with access through an NPT cable gland (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). 1600MHz On the other hand, the Ex antenna is omnidirectional with 2.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. We offer you the most powerful security Examples

25 Ex ANTENNA ATEX SAT 1600MHz NPT IP66 Zones 1 and 2 APPLICATION Hazardous tank level monitoring Wireless bridges Hazardous area computers Utility systems where explosive gases may be present Offshore platforms Power plants Utility systems with the possibility of explosive gases presence. REFERENCE (Example of a box with 5 meter cable) EJBANTEx1600_05 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 1600 MHz Ref. ANTEx 1600NPT. Box with cable gland. Ref. EJB1389R2.4N3/4 NORMATIVE CENELEC EN 60079-0: 2012 EN 60079-1: 2007 EUROPEAN DIRECTIVE 94/9/EC: 1994 UL, cul listed IECEx Need more information? SECTORS Oil & Gas Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power

26 Ex ANTENNA ATEX SAT 1600MHz NPT IP66 Zones 1 and 2 MARKING ATEX Marking: Ex d IIB T5 Gb. UL Marking: Class I Div 1, Groups C, D. Ambient Temperature: -20/+40 ºC. CODE Position of entries Ø Cable EntrY ExterNAL DIMENSIONS (mm) D1 A B Weight (Kg) EJBANTEx1600 8/10,5 10,5/13 13/15,5 15,5/18 89 110 130 0,6 SPECIFICATIONS ANTENNA Box Technical Data Frequency: 1600 MHz (Iridium Satellite 1616MHz - 1626MHz) Impedance: 50 Ω Gain: 2.0 dbi Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC con: 5.85, 148.6mm Zones: 1-2 Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2.

27 Ex ANTENNA ATEX GPRS DUAL 801-949MHz & 1901-2000MHz NPT 824-896MHz & 1850-1990MHz NPT 880-915MHz & 1710-1785MHz NPT IP66 Zones 1 and 2 The Ex GPRS Antenna system, with an IP 66 degree of tightness, includes an Ex antenna, ICECEx, Dual band 801-940 MHz & 1901-2000 MHz, 824-896MHz & 1850-1990 MHz and 880-915MHz & 1710-1785MHz that can be used in zones 1 and 2. This antenna is mounted over a lightweight and compact enclosure made from aluminium alloy used to adjust the cable, with access through an NPT cable gland (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). 801-949MHz & 1901-2000MHz 880-915MHz & 1710-1785MHz On the other hand, the Ex antenna is omni-directional with 2.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. We offer you the most powerful security Examples Examples 824-896MHz & 1850-1990MHz

28 Ex ANTENNA ATEX GPRS DUAL IP66 Zones 1 and 2 801-949MHz & 1901-2000MHz NPT 824-896MHz & 1850-1990MHz NPT 880-915MHz & 1710-1785MHz NPT APPLICATION Hazardous tank level monitoring Wireless bridges Hazardous area computers Utility systems where explosive gases may be present Offshore platforms Power plants Utility systems with the possibility of explosive gases presence. PCS, AMPS, GPRS, 802.11 NORMATIVE CENELEC EN 60079-0: 2012 EN 60079-1: 2007 EUROPEAN DIRECTIVE 94/9/EC: 1994 UL, cul listed IECEx SECTORS REFERENCE (Example of a box with 5 meter cable) EJBANTEx0.8D1.9_05 (Example of a box with 5 meter cable) EJBANTEx0.8D1.8_05 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX Dual 801-949MHz & 1901-2000MHz Ref. ANTEx801-1901NPT Box with cable gland. Ref. EJB1389R2.4N3/4 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX Dual 824-896MHz & 1850-1990MHz Ref. ANTEx824-1850NPT Box with cable gland. Ref. EJB1389R2.4N3/4 Oil & Gas Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power (Example of a box with 5 meter cable) EJBANTEx0.8D1.7_05 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX Dual 880-915MHz & 1710-1785MHz Ref. ANTEx880-1710NPT Box with cable gland. Ref. EJB1389R2.4N3/4 Need more information?

29 Ex ANTENNA ATEX GPRS DUAL IP66 Zones 1 and 2 801-949MHz & 1901-2000MHz NPT 824-896MHz & 1850-1990MHz NPT 880-915MHz & 1710-1785MHz NPT MARKING ATEX Marking: Ex d IIB T5 Gb. UL Marking: Class I Div 1, Groups C, D. Ambient Temperature: -20/+40 ºC. CODE Position of entries Ø Cable EntrY ExterNAL DIMENSIONS (mm) D1 A B Weight (Kg) EJBANTEx0.8D1.9 EJBANTEx0.8D1.8 EJBANTEx0.8D1.7 8/10,5 10,5/13 13/15,5 15,5/18 89 110 130 0,6 SPECIFICATIONS ANTENNA Box Technical Data Frequency: Dual band 801-940 MHz & 1901-2000 MHz, 824-896MHz & 1850-1990MHz NPT, 880-915MHz & 1710-1785MHz NPT. Impedance: 50 Ω Gain: 2.0 dbi Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC con: 5.85, 148.6mm Zones: 1-2 Body and lid of a low copper content aluminium alloy. Internally ribbed lid for reduced weight. Stainless steel hinges. Gasket of acid/hydrocarbon-resistant silicone. Certification label located inside the box. Stainless steel bolts and screws M6 stainless steel earth screws with anti-rotation brackets. Electro galvanized steel mounting brackets. Zones: 1 2.

30 Ex ANTENNAS ATEX 915MHz NPT / 2.4GHz / 5GHz / 2.4GHz & 5GHz / IP66 Zones 1 and 2 915MHz The Ex WIFI Antenna system, with an IP66 degree of tightness, includes an Atex IECEX antennas 915MHz, 2.4GHz, 5GHz and 2.4GHz & 5GHz that can be used in zones 1 and 2. This antenna is mounted over a lightweight and compact enclosure made from aluminium alloy used to adjust the cable, with access through an NPT cable gland (Ex d) for unarmed cables (sizes: 8/10,5mm 10,5/13mm 13/15.5mm 15.5/18mm). The extensive range offered caters to specific customer requirements and can be installed in areas classified as Zone 1, 2 (hazardous areas). On the other hand, the ATEX antenna is omni-directional with 2.0 dbi gain and an integrated TNC coaxial connector for ease of installation. The upper body is optimized for rugged industrial and hazardous applications while maintaining maximum radio frequency transmission and reception efficiency. Examples 2.4GHz 5GHz 2.4GHz & 5GHz Examples Examples

31 Ex ANTENNAS ATEX NPT IP66 Zones 1 and 2 APPLICATION Hazardous tank level monitoring Wireless bridges Hazardous area computers Utility systems where explosive gases may be present Offshore platforms Power plants Utility systems with the possibility of explosive gases presence. SECTORS Oil & Gas Offshore & High sea Chemical & Refinery Industry & Machinery Maritime & Seaport Oil Drilling Floating Production FLNG Natural Gas Liquid FPSO Floating Production Pharmaceutical Food & Beverage Air Transport Nuclear & Thermal Power NORMATIVE CENELEC EN 60079-0: 2012 EN 60079-1: 2007 EUROPEAN DIRECTIVE 94/9/EC: 1994 UL, cul listed IECEx REFERENCE (Example of a box with 5 meter cable) EJBANTEx915 (Example of a box with 5 meter cable) EJBANTEx2400_05 (Example of a box with 5 meter cable) EJBANTEx5000_05 (Example of a box with 5 meter cable) EJBANTEx2.4D5 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 915 MHz Ref. ANTEx915NPT. W Box with cable gland. Ref. EJB1389R2. 4N3/4z For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 2.4 GHz Ref. ANTEx 1575NPT. Box with cable gland. Ref. EJB1389R2.4N3/4 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX 915 GHz Ref. ANTEx 5000NPT. W Box with cable gland. Ref. EJB1389R2.4N3/4 For 5 meters cable, add to the end of the reference: _05 For 10 meters cables, add to the end of the reference: _10 Cordless: don t add anything.. Antenna ATEX Dual 2.4&5 GHz Ref. ANTEx2400-5000NPT. W Box with cable gland. Ref. EJB1389R2. 4N3/4

32 Ex ANTENNA ATEX IP66 Zones 1 and 2 NPT MARKING ATEX Marking: Ex d IIB T5 Gb. UL Marking: Class I Div 1, Groups C, D. Ambient Temperature: -20/+40 ºC. CODE Position of entries Ø Cable EntrY ExterNAL DIMENSIONS (mm)) D1 A B Weight (Kg) EJBANTEx915 EJB1389R2.4N3/4 EJBANTEx5000 EJBANTEx2.4D5 8/10,5 10,5/13 13/15,5 15,5/18 89 110 130 0,6 SPECIFICATIONS ANTENNA Frequency: 1600 GHz, 5 GHz, 2,4 GHz, Dual band 2.4 GHz & 5 GHz (802.11n) Impedance: 50 Ω Gain: 2.0 dbi Maximum power: 2 Watts Connector type: Female TNC Mounting base: 20mm (3/4 NPT) Impact rating: 7 Jules Weight: 1.06 lbs., 0.48 kg Maximum length including TNC con: 5.85, 148.6mm Zones: 1-2 Box Technical Data Body and lid of a low copper content aluminium alloy. Screw-on lid with safety fastening grub screw. Gasket of acid/hydrocarbon-resistant silicone Entries with NPT UNI ISO 7/1 thread Certification label located on the lid Stainless steel bolts and screws Stainless steel earth screws with anti-rotation brackets. Zones: 1 2.

33 DELVALLE OFFERS OTHER SOLUTIONS ATEX Contact us at: atex@atexdelvalle.com We ll give a solution as Atex enclosure Luxorex Serie Increased safety enclosure Tribex Serie Atex terminal boxes Terbox Serie Control equipment Contrex Serie Plug and socket boxes Connex Serie Pressurized enclosure Ex p Peppex Serie

34 DELVALLE OFFERS OTHER SOLUTIONS ATEX Contact us at: atex@atexdelvalle.com We ll give a solution as Atex junction box Geoex Serie Flameproof enclosure Atex Ex d EJB Serie Workstations Pcex Serie Lighting LED Atex Luminex Serie Radios Atex Ex Walkies Talkies Ventilation and Air Conditioning

Flexible solutions Atex & IECEX HAZARDOUS AREA SOLUTIONS Paso del Prao, 6. 01320 Oyón (Álava). Spain www.atexdelvalle.com - atex@atexdelvalle.com Contact us, we will be available at any time.