Quick Installation Guide ARM-X4404 Advanced Radio Modem

Similar documents
ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

The wireless alternative to expensive cabling...

User Manual CTP4/8/16

Data Acquisition Modules/ Distributed IO Modules

The wireless alternative to expensive cabling...

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

The wireless alternative to expensive cabling...

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

PLC-K506 Series FEATURES DESCRIPTION FEATURES

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

ATSBT-BOTTOM-FM-4G. Electrical Specifications. Product Classification. General Specifications. Mechanical Specifications. Bottom Smart Bias Tee

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

AERINOS Profisens - Wireless IoT Platform

The wireless alternative to expensive cabling...

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

02/11/2015

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

User Manual. User Manual. Wide Band Booster (30dBm) 2012 February. Information in this manual is subject to change without notice

Ethernet to 900 MHz RF Modem

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

GPS Dome Installation Manual

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

Radio Transmission System Point-to-point Gateway DX80G2M6S-PM2

Antenna Overview. Version /11/19

RF over Fiber Optic Transceiver OZ816 Series Ultra Broadband 6 GHz

AUR.EL RTX-MID-868-OOK DESCRIPTION. MECHANICAL DIMENSIONS and PIN-OUT. Absolute maximum values

XMU+ Environmental, Safety and Specifications

02/11/2015

WIRELESS MODBUS GATEWAY WGW410

[ tima-datasheet-en v11.1 ]

Pulse Scaler for DIN Rail Attachment

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

KMT - Kraus Messtechnik GmbH

Telemetrie-Messtechnik Schnorrenberg

GPS Dome Model T. Installation Manual

mod. BT 20 / GSM 2004

KMT - Kraus Messtechnik GmbH

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Multifunctional counter tico 772/773/774

Main Features. Highlights

Universal/Standard Ku-band 16W BUC MODEL No. NJT8319 series

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

INPROX sensors. displacement MLS compact ccd-laser distance sensor

Teleterm D3G Remote Terminal Unit

Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

02/11/2015

R-Log Radio data logger

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Antenna Overview. Version /10/20

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

DESCRIPTION MECHANICAL DIMENSIONS AND PIN-OUT

Industrial Modbus I/O Modules

maxon document number:

D2 W LT and D2 W LR IF 1569 Wireless I/O

Telemetrie-Messtechnik Schnorrenberg

General Specifications

83 SERIES. 83 Series - Modular timers A. Features

KMT - Kraus Messtechnik GmbH

Technical guide. EC300 motor V8

ADAM 4000/4100 Series

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Paperless Recorder PR20

Totalizing Counters mini-i

Teleterm E3 Meter Concentrator Module

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

PFXLM4B01 D * * (1) (2) (3) (4)

RS3400W/04 77 GHz Radar Sensor

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

CAN-IO Custom IO remote module

CQM1H-MAB42 Analog I/O Board Connector CN1: Analog inputs 1 to 4. Name Specifications Model number Slot 1 (left slot) High-speed Counter Board

5.5 SLG 75. Read/Write Devices Read/Write Antennas

900 MHz Antenna Sharing Combiner ASC900VG11A

Standard C-band 10W BUC MODEL No. NJT5762 series

850 MHz Antenna Sharing Combiner ASC850VG12A

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

FM20VHIR FM20VVIR. RedLink Fiber Optic Receiver for Direct High Voltage Switching Preliminary Data Sheet DESCRIPTION FEATURES APPLICATIONS

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps

ST600 TRANSMITTER OPERATING INSTRUCTIONS

LINEAR POTENTIOMETER. LZW Series. Key-Features:

GPS Splitter 1 in Rack Mount

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

DSA700 Series Spectrum Analyzer

Optimising controls Vacuum switches

User Manual LTE 4G 850/2600. Wide Dual Band Repeater REDUTELCO TECHNOLOGY CO.,LTD January

DSEM640. DSEControl PROGRAMMABLE CONTROLLER FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

UHF Wireless System CONTENTS

Low Loss Combiner LLC-1900-IN DATA SHEET. Overview

Radio Transmission System Point-to-point node DX80N2X6S-PM8L

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Transcription:

Quick Installation Guide ARM-X4404 Advanced Radio Modem Before setting the product, please read the following recommendations Do not plug 110 or 220V power supply to the radio modem (Operating voltage: 15-30 Vdc) For your security, the connection of the power supply to the ARM radio modem must be realized power off. Check the module s power supply is cut before all intervention. Do not install directly the ARM radio modem in outdoor. It is not waterproof and if such installation is required it needs to be integrated in a waterproof case or electrical cabinet. When using a metallic electrical cabinet, the antenna must be installed outside. Before connecting or disconnecting the antenna, make sure to discharge to the ground, static electricity as the antenna input is very sensible. Connect the metal DIN rail and consequently the ARM to the ground. If the antenna is fixed to an outdoor pole, the later must be also connected to the ground. A surge protection module must be inserted on the antenna cable, between the antenna and the ARM radio modem. Respect the standards by using only recommended cables and antennas in order to be within the ERP authorized by the regulations (500mW or 27dBm). QIG ARM-X8800uk v1.0 26.02.07 Page 1

1. DESCRIPTION OF ARM-X8800 Antenna connector Coding wheel for channel selection Logical terminal block Logical Input Output signal LEDs RS232 port Alarm output Power supply AnalogOutput terminal Note : the alarm output and the static outputs of the ARM-X4404 switch respectively to "1" and "0" logic status when the radio transmission is interrupted more than the watchdog timer. QIG ARM-X8800uk v1.0 26.02.07 Page 2

2. INSTALLATION 2.a. Antenna We recommend to use our antenna range : ANT868-14S-L (¼ wave antenna): to operate appropriately this antenna needs a metallic ground plan. It can be mounted on a connection cabinet for example or on the roof of a car. ANT868-12S-L (½ wave antenna): it doesn t need a ground plan to operate. It can be installed directly on the polyester slate of a vehicle or on a PVC casing. The ANT868-12FSC version can be directly mounted on the radio modem. The radio wave propagation is highly influenced by the position and the height of the antenna. It is recommended to install the two antennas line of sight (without obstruction between both antennas) and to place the antennas as high as possible. For outdoor long distances, prefer a mast mounting antenna (ANT868-BZ) with low loss cable (CFP10). Try to have the shortest coaxial cable (for example for a 25m CFP10 cable, the loss is about 3dB (that means the ERP is divided by 2). Position of the antenna: It is recommended to install the antenna at a minimum height of 2 m (the farther you want to send information, the higher you must install the antenna). No metallic obstacle within a radius of 1m of the antenna. Antenna YES NO Avoid metallic obstable in this area R=1 m R=1 m No metallic obstable in this area No metallic obstable in this area QIG ARM-X8800uk v1.0 26.02.07 Page 3

2.b Connections All connections must be done with power switched off logical terminal block Pin #1 Input 1 Pin #2 Input 2 Pin #3 Input 3 Pin #4 Input 4 Pin #5 Output 1 Pin #6 Output 2 Pin #7 Output 3 Pin #8 Output 4 Pin #9 0 volt Pin #10 Power supply Analog terminal block Pin #1 Analog Output 1 Pin #2 Analog Output 1- Pin #3 Analog utput Output 4++ 2+ Pin #4 Analog Output22putnput 2 - Pin #5 Analog Input Output 1 +ut 4 3 Pin #6 Analog Output 3 - Pin #7 Analog Output 4 Pin #8 Analog Output + 4 - Pin #9 0 volt Pin #10 Vref (Compatible with PNP output) 0-10V + RS485 and power supply terminal block Pin #1 - Pin #2 - Pin #3 IN Pin #4 OUT Pin #5 0 volt Pin #6 +Power +Power supply Important : The pin #6 (power supply terminal block), the pin #10 (of the logical terminal block), the pin #10 (of the analog terminal block) must be connect to the + of the power supply. The pin #5 (power supply terminal block), the pin #9 (of the logical connector) and the pin #9 (of the analog connector) must be connected to the "0 volt" of the installation. The analog output for all input are connect internal to 0V Contact us for wiring NPN outputs on the inputs connector. Every Inputs / Outputs extension module must be connect the same way. QIG ARM-X8800uk v1.0 26.02.07 Page 4

2.c Radio channel selection Select a free channel with the coding wheel. If there are several radio devices in the area for different applications, it is recommended to set up a frequency plan : same frequency for all devices operating in the same application. Leave a free channel between the channels of 2 applications. Channel Frequency (MHz) Channel Frequency (MHz) 0 869.800 8 868.425 Max. ERP : 25mW 1 868.075 9 868.475 Duty cycle : 1% 2 868.125 A 868.525 3 868.175 B 869.850 Max. ERP : 5mW 4 868.225 C 869.900 Duty cycle : 100% 5 868.275 D 869.475 Max. ERP : 500mW 6 868.325 E 869.525 Duty cycle : 10% 7 868.375 F 869.575 The output power level depends on the radio channel. The D / E / F channels allow to send information at farthest. For a power of 5 mw you obtain a range up to 1000m, for 25mW a range of 2000m and for 500mW up to 5km in cleared environment (LOS). (These distance ranges are given for information and depend a lot on the environment). Use the maximum emission power only if necessary. 3. TECHNICAL FEATURES Product reference : ARM-X8800 Type Power supply Consumption Emission Power Frequency Number of channels Distance Range Digital Ouputs Digital Inputs Analog Output Connection Housing / Protection index Dimensions Operating / Storage temperature Agreement Characteristics 4 Digital inputs / 4 Digital outputs/ 4 Analog Output 15 30 VDC Separated power supply for base module and I/O modules < 50 ma in 5 mw and 25mW < 500 ma in 500 mw 5 mw / 25 mw / 500 mw 868.000 to 869.000 MHZ 16 channels of 50kHz Up to 5 kms in open space (or over with a high point) Protected Mosfet, max current : 250mA Opto-isolated (common ground), impedance: 2.2kΩ Modbus counters (E1-E7: 500Hz, E8: 10kHz) Output 0-10V, Conversion 12bits, Load Impedance min 2Kohm Error Max 0.5% PE Plug connector (3.96mm pitch) Aluminium (IP40) case for DIN rail mounting 105 x 105 x 60 / module (2 modules minimum) - 20 C to + 50 C / -30 C to +70 C ETS 300-220 / CE For further information (user guide, application notes, ), visit our website www.atim.com. ATIM RADIOCOMMUNICATIONS Les Guillets 38250 Villard de Lans France Phone : +33 (0)4 7695 50 65 Fax : +33 (0)4 7695 50 64 Email : tech@atim.com www.atim.com QIG ARM-X8800uk v1.0 26.02.07 Page 5