Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes

Similar documents
ACCUMEASURE. Non-contact Capacitance Position Measurement with Nanometer Accuracy. A worldwide leader in precision measurement solutions

Mercury TM 1500V Vacuum Rated Digital Output Encoders

Mercury TM 1500 Digital Output Encoder Systems

More Precision. capancdt DTV // Measuring Disc Thickness Variation

LION PRECISION. TechNote LT February, Capacitive Sensor Operation and Optimization

Mercury TM 1200 PCB-Mount Analog Encoders

queensgate a brand of Elektron Technology

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

FLEXIBLE CURRENT PROBES

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

Universal Radius Mounting Option. Fixed Radius Mounting Option

Additel 875 Series Dry Well Calibrators

ODiSI 6000 Series Optical Distributed Sensor Interrogators

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Capacitive sensors capancdt

Rotary Encoder System Compact Model Range

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

CAPACITIVE SENSORS. Series KS. Key-Features:

Current Probes. User Manual

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

P-810 P-830 Piezo Actuators

5790A Automated AC Measurement Standard

Recorders OUR MOST COMPACT CHART RECORDER! Input Number Chart Special Description Type of Pens Size Options Page

Non-Contact AC Voltage Probe SP3000, AC Voltage Probe SP9001

Moving Test - MT3000

DIT-5200L. Non-Contact Displacement Differential Measuring System User s Manual

DC MHZ PXI Differential Instrumentation Amplifier

PHILTEC PHILTEC FIBEROPTIC SENSORS FROM INNER SPACE TO OUTER SPACE SOLVE YOUR MEASUREMENT PROBLEMS FIBEROPTIC SENSORS

M70LL Laser Distance Sensor

TechNote. T001 // Precise non-contact displacement sensors. Introduction

OPTOFORM 40 ENGINEERING SPECIFICATIONS

Additel 875 Series Dry Well Calibrators

AC/DC Resistance Standard DRR-112

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Modular and Upgradable Fully Automated High Resistance Measurement Systems

INSTRUCTION MANUAL. IM7298, Revision A ( )

Keysight Technologies Optics and Laser Heads for Laser-Interferometer Positioning Systems

Loop & Magnetic Field Coil

Torque Sensor Accessories and Services

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

More Precision. capancdt // Capacitive displacement sensors and systems

World-Class Accuracy & Measurement Range (40 Conventional Models)

AC/DC Current Probes Model MR411 Model MR521

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

RGH25F encoder system

Laser Displacement Sensor Z4M. Ordering Information

SAS-563B Active Loop Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

eddyncdt 3010 Non-Contact Displacement Measuring Systems

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

M302RM OPERATING MANUAL

Model 6517B Electrometer / High Resistance Meter Specifications

How Resonance Data is Used

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

CSH1.2 CSH1.2FL CSH2FL CS2 CSH2 CSE2 CS3

PL112 PL140 PICMA Bender

PIHera Piezo Linear Precision Positioner

Operation manual. Model 24 Infrasound Sensor

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

LED Displacement Sensor

Fluke 5820A Oscilloscope Calibrator Specifications

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

rotary encoder system

Load Cell Accessories and Services

ArbStudio Arbitrary Waveform Generators

ULTRASTAB I U Precision

AlphaProx inductive sensors. Measure distances accurate to a micrometer.

Each Height Master is supplied with a gauge block for reference-height setting. Fitted wooden case supplied. SPECIFICATIONS

AC/DC Current Oscilloscope Probe Model SL261

Non-contact Thickness Meters/Displacement Meters

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

GUZIK V2002 Spinstand with XY-Positioning For Head, Headstack and Disk Testing

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Torque Sensor Series 3000 and Series 4000

7600 Isolated Digitizer and Receiver

High Speed Milliohm Resistance Meter

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

847H. Description. Features. Specifications

PHV RO High Voltage Passive Probe. Instruction Manual

Compact Nanopositioning System Family with Long Travel Ranges

QRS14 User s Guide. MEMS GYROSCOPE Model QRS14. Systron Donner Inertial Sales and Customer Service. Phone: Fax:

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

WaveLink High Bandwidth Differential Probing System (16 GHz 25 GHz)

Green LED (right of 'D' type connector)

Model LIA100. Lock-in Amplifier

SENSORS CLIMATRONICS CORPORATION (631) MANUAL HEATED SONIC ANEMOMETER P/N M Rev A 2.0 INSTALLATION 1.

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

Optical Measurement P-1

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

AlphaProx inductive sensors. Measure distances accurate to a micrometer.

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Transcription:

4810 Non-Contact Capacitance Gauging Instrument & Series 2800 Capacitive Probes Sub nanometer resolution for ultra-precise measurements Exceptional temperature stability Wide variety of precision capacitive sensors available Standard analog outputs for easy connection to A/D boards Large standoff distances allow safe gauging of delicate parts Superior price and performance Portable, lightweight Description The 4810 is a single channel instrument that provides an analog display of probe displacement on the front panel. The 4810 provides analog output via a BNC jack on the front panel for easy connection to oscilloscopes, spectrum analyzers or computer based A/D boards. The 4810, along with the 2800 series family of standard and custom probes, uses an advanced capacitive gauging technology to provide exceptional resolution, large operating ranges and large standoff distances. The large, easy-to-read front panel display makes the 4810 an ideal production tool for operations requiring visual verification of measurements. Features Sub nanometer resolution for ultra-precise measurements Exceptional temperature stability for a wide variety of environmental measurement applications Wide variety of precision capacitive sensors for measuring even the most difficult size and shape target Standard analog outputs for easy connection to A/D boards Large standoff distances allow safe gauging of delicate parts Superior price/performance Patented PhaseLock probe driver circuitry for improved accuracy on ungrounded targets and applications such as thickness Selectable filters for maximum resolution: 10 Hz, 100 Hz, 1 khz, 10 khz Probes are interchangeable with straightforward recalibration Portable, lightweight Applications Non-contact, non-destructive measurements Precision dimensional gauging X-Y positioning Real-time in-process measurements Slide and spindle runout In-process sheet thickness Vibration analysis Servo-loop positioning systems Wear measurements Precision alignment Ultra high vacuum measurements Ultra high stability Go/no go gauging Laser calibration High-precision individual unit calibration at factory using Microsense-developed laser interferometry system. Calibration traceable to NIST. Performance graph included. Options Operating ranges Operating ranges can be user specified to optimize resolution for a specific application. Optional driven target mode significantly improves resolution. Optional Ultra High stability system for the most demanding long term measurements Series 2800 probes Microsense LLC has developed a new, lower cost family of high performance capacitive sensors providing a greater temperature stability and measurement linearity. Measurement ranges from 20 microns to 2 millimeters are available in standard products. Custom probe configurations are available to met unique applications requirements. www.microsense.net

4810 - Specifications Performance Measurement Range ± 10 microns to ± 1000 microns full scale, depending on probe selection. Measurement resolutions Typically better than 20 PPM of full scale range @ 1kHz. Resolutions of better than 1 PPM are attainable: Typical Resolutions (RMS, nm) Sensor ø Range Bandwidth Resolutions PPM Optional (mm) ± µm (Hz) (nm) Target 5 30 10 0.05 0.83 N 5 30 1000 0.16 2.7 N 5 250 1000 7.0 14.0 N 5 250 1000 4.0 8.0 Y 1 30 1000 2.5 41.6 N 1 30 1000 1.2 20 Y 1 30 100 0.7 11.6 N 1 30 100 0.4 1.6 Y Actual resolution depends on probe selection, bandwidth and operating range. Resolution improves with larger sensor area, reduced bandwidth and smaller range. Detailed specifications are provided with probe information Linearity Typically better than 0.025% over full scale range, depending on probe model and operating range Detailed Stability Standard systems offer excellent stability. Typical stability is on the order of 100 PPM over 1 F or 200 PPM per PC. Optional high stability system: For the most demanding applications where stability over weeks and months is required to assure accuracy and productivity. Typical stabilities are on the order of 50 PPM over 6 months. Systems come with special stability testing, temperature and humidity correction coefficients. Bandwidth Standard 1 khz Jumper Selectable 10 Hz, 100 Hz, 10 khz. Inputs/Outputs Probe inputs Single, accepts Series 2800 probe family. Drive Synchronization For multi-unit applications. Sensors may be driven in or out of phase. Limits User adjustable digital outputs for detecting overrange and measurement limits. Adjustments/Indicators Front panel adjustments Calibration adjustment for scale factor. Offset adjustment for zero setting. Limit settings. Front panel LED indicators Power, + limit, - limit Physical Dimensions 18 cm- L x 11 cm-w x 4 cm-h (7.0" x 4.25" x 1.5") Weight 0.5 kg (1.1 lbs) Operating Environment Temperature 5 C to 50 C (41 F to 122 F) Humidity 0 to 95% RH, non condensing Power Requirements 90-240 VAC, Standard Microsense Universal Low Noise Power Supply with IEC Connector included with Instrument Probe Selection Accepts Series 2800 and 2900 passive probes Analog Output Standard ± 10 volts for full scale range Optional ± 5 v, 0-10 v 70 Industrial Ave E. Lowell, Ma. 01852 Phone: (978) 843 7670 Fax: (978) 843 7670 e-mail: sales@adetech.com Microsense LLC (specifications subject to change without notice) Series 2800 Passive Probes www.microsense.net

Probe Selection Procedure Steps Guidance 1 Identify Target Shape and Minimum Target Dimension by observing item to be measured and comparing with the guidance illustrations. Sensor Minimum Target Dimension Dia. Sensor Minimum Target Dimension Sensor Dia. Minimum Target Dimension FLAT CYLINDRICAL SPHERICAL 2 Calculate Maximum Sensor Diameter (Note: This dimension is less than the minimum target dimension because all of the spreading electric field needs to be on the target surface.) Minimum Target Dimension X{ X Shape Constant = Maximum Sensor Diameter 0.60 for Flat Target } 0.25 for Cylindrical Target = 0.20 for Spherical Target 3 Determine Optimum Sensor Size from step 2 answers For best overall performance select the larger sensor size option. However, smaller sensor sizes may be preferred if surface profile or flatness of a textured surface is being measured, or if measurements are being made near a target edge. SENSORS A B C Target Surface Sensor A SENSOR OUTPUTS Sensor B Sensor C 4 Select Probe Style Axial style is usually preferred, however other styles are available to facilitate target access. Refer to the probe diagrams on the preceding pages. Axial Lo-Profile Right Angle 30 o Axial Correct Standoff Incorrect Standoff 5 Determine Probe Ordering Information Use answers 2,3, and 4 above for probe and sensor size. Consult sensor drawings. Refer to the following pages for the correct probe choice Note: On special request, probes can be custom designed to suit specific customer needs. Consult the factory. www.microsense.net

Passive Probes 2806L 0.5-0.66 mm Diameter Sensors Compatible with 4810, 4800, 4805 2809 2817 Note: Noise Performance of 0.66 mm sensor will be better than 0.5 mm sensors Range Standoff (um,mil) (um,mil) ± 5,0.25 10, 0.4 ± 10,0.4 20, 0.8 ± 25,1 50, 2 ± 50,2 100, 4 Performance Specification 0.5 mm Diameter Sensor Linearity Target Type (, ) % Full Scale Consult Factory Consult Factory 0.02% 0.05% Resolution By Filter Setting(nanometer, microinch, r.m.s) 10 Hz 100 Hz 1 khz 0.23, 0.009 0.77, 0.03 0.12, 0.005 0.39, 0.015 1.3, 0.05 4.1, 0.16 0.41, 0.017 1.45, 0.06 5.56, 0.22 19.5, 0.78 3.6, 0.14 11.3, 0.45 11.0, 0.44 38.9, 1.55 7.2, 0.28 22.3, 0.90 0.05, 0.002 0.03, 0.001 0.21, 0.009 0.10, 0.004 1.23, 0.05 0.62, 0.025 2.45, 0.05 1.22, 0.098 10 khz 2.4, 0.10 1.29, 0.05 12.9, 0.5 5.8, 0.24 60.9, 2.4 32.5, 1.3 121.0, 4.8 64.7, 2.6

Passive Probes 1 mm Diameter Sensors Compatible with 4810, 4800, 4805 2803 2807 Range Standoff (um,mil) (um,mil) ± 10,0.4 20, 0.8 ± 25,1 50, 2 ± 50,2 100, 4 ± 100,4 200, 8 Performance Specification 1 mm Diameter Sensor Linearity Target Type (, ) % Full Scale Consult Factory 0.12% 0.10% 0.02% Resolution By Filter Setting(nanometer, microinch, r.m.s) 10 Hz 100 Hz 1 khz 0.45, 0.018 1.5, 0.06 0.23, 0.009 0.74, 0.03 1.2, 0.048 3.4, 0.16 0.6, 0.024 2.0, 0.08 6.64, 0.27 20.9, 0.83 2.1, 0.084 7.27, 0.29 22.2, 0.89 78.3, 3.1 14.4, 0.58 45.0, 1.8 0.1, 0.004 0.06, 0.002 0.26, 0.01 0.15, 0.006 1.08, 0.043 0.51, 0.02 4.92, 0.2 2.46, 0.098 10 khz 4.5, 0.18 2.3, 0.09 12.0, 0.48 6.1, 0.25 65.1, 2.6 29.4, 1.18 244, 9.7 130, 5.2

Passive Probes 2-3 mm Diameter Sensors Compatible with 4810, 4800, 4805 2804 2812 2815 Range Standoff (um,mil) (um,mil) ± 25,1 50, 2 ± 50,2 100, 4 ± 100,4 200, 8 ± 250,10 500, 20 Performance Specification 2 mm Diameter Sensor Linearity Target Type (, ) % Full Scale 0.12% 0.05% 0.02% 0.10% Resolution By Filter Setting(nanometer, microinch, r.m.s) 10 Hz 100 Hz 1 khz 0.37, 0.015 1.18, 0.047 0.22, 0.009 0.70, 0.028 2.3, 0.09 7.5, 0.3 1.17, 0.047 3.77, 0.15 4.79, 0.19 15.6, 0.62 2.43, 0.097 7.8, 0.31 55.3, 2.2 195, 7.8 35.8, 1.4 111, 4.5 0.094, 0.004 0.068, 0.003 0.51, 0.021 0.30, 0.012 1.06, 0.042 0.61, 0.024 12.2, 0.49 6.1, 0.24 10 khz 3.7 0.15 2.1, 0.084 23, 0.92 11.8, 0.47 47.8, 1.91 24.6, 0.98 606, 24.2 324, 13.0

Passive Probes 5 mm Diameter Sensors Compatible with 4810, 4800, 4805 2805, 2805V Note: 2805 V is Vacuum Compatible 2820, 2820V, 2820HS, 2820HSV Notes: The 2820 Series are made of Alumina Ceramic. 2820V -Vacuum Compatible. 2820HS - High Stability Version. 2820HSV - High Stability, Vacuum Compatible Range Standoff (um,mil) (um,mil) ± 50,2 100, 4 ± 100,4 200, 8 ± 250,10 500, 20 ± 500,20 1000, 40 Performance Specification - 5 mm Diameter Sensor Linearity Target Type (, ) % Full Scale 0.05% 0.02% 0.04% 0.12% Resolution By Filter Setting(nanometer, microinch, r.m.s) 10 Hz 100 Hz 1 khz 0.15, 0.006 0.3, 0.12 0.15, 0.006 0.3, 0.012 0.75, 0.03 2.4, 0.95 0.4, 0.03 1.2, 0.05 11.3, 0.45 36.7, 1.46 5.7, 0.23 18.4, 0.74 23.7, 0.95 77.1, 3.1 12.1, 0.48 38.7, 1.5 0.11, 0.004 0.11, 0.004 0.43, 0.017 0.22, 0.009 2.5, 0.1 1.46, 0.06 5.2, 0.21 3.0, 0.12 10 khz 1.6, 0.064 1.6, 0.064 7.5, 0.3 4.1, 0.17 112, 4.5 58.1, 2.3 236, 9.4 121, 4.9

Passive Probes 10 mm Diameter Sensors Compatible with 4810, 4800, 4805 2810, 2810V Note: 2810V is Vacuum Compatible 2811, 2811V Note: 2811V is Vacuum Compatible 2821, 2821V, 2821HS, 2821HSV Notes: The 2821 Series are made of Alumina Ceramic. 2821V -Vacuum Compatible. 2821HS - High Stability Version. 2821HSV - High Stability, Vacuum Compatible Range Standoff (um,mil) (um,mil) ± 250,10 500, 20 ± 500,20 1000, 40 ± 1000,40 2000, 80 ± 2000,80 4000, 160 Performance Specification 10 mm Diameter Sensor Linearity Target Type (, ) % Full Scale 0.04% 0.02% 0.07% Consult Factory Resolution By Filter Setting(nanometer, microinch, r.m.s) 10 Hz 100 Hz 1 khz 1.6, 0.06 4.8, 0.19 0.94, 0.038 2.5, 0.1 7.0, 0.28 22.8, 0.91 4.3, 0.17 13.4, 0.54 45.2, 1.8 147, 5.9 23.0, 0.92 74, 3.0 95, 3.8 309, 12.3 48.3, 1.93 155, 6.2 0.94, 0.038 0.56, 0.023 1.9, 0.075 1.3, 0.05 10.1, 0.4 5.8, 0.23 21.1, 0.84 12.1, 0.49 10 khz 15.9, 0.64 9.6, 0.39 72, 2.9 40.4, 1.62 451, 18 232, 9.3 947, 37.9 487, 19.5

Technical Notes Probe Clamping - With the exception of the 2810 and 2811 and ceramic probes the probes should be held in the area indicated on the drawings. Use of a split ring or collet is recommended. Use of a set screw is not recommended as it may cause a deformation of the probe body which could effect calibration. Target Angle: The angle of the probe face to the target is important for obtaining a quality measurement. The smaller the standoff and range, for a given probe size, the more critical the angle of the probe face to the target. Angular deviations result in increases in nonlinearly and in the signal gain (cosine error). The following charts illustrate typical increases in non linearity and gain for the 2800 series probes at the close and far ranges. "Close Range" corresponds to the smaller ranges found performance tables in the preceding pages and "Far Range" larger ranges. increased output noise from the gaging system For dual probe applications such as thickness measurements well grounded targets are desired but not required. Using a patented technology Microsense can balance the currents of the 2 probes and drive them 180 degrees out of phase to make a quality measurement. Please discuss your requirements with your representative for this type of application. Target Size - In general the size of the target should be at least 20% larger than the diameter of the outer guard ring of the probe. Target Resistance - Target resistance of less than 100k Ohms will not cause measurement errors. However, a poorly grounded target will be more susceptible to noise pickup. It is acceptable to capacitively ground a target. Capacitance's of 1000 pf or higher work well. Target Angle (Parallelism) Error Estimates Linearity Error % of Full Range Typical Non Linearity Error for Close Range 3 2 1 0 0.1 0.25 0.5 0.75 1 Target Angle (Degrees) Gain Correction 1.1 1.08 1.06 1.04 1.02 1 Typical Gain Correction for Close Range 0.1 0.25 0.5 0.75 1 Target Angle (Degrees) Linearity Error % of Full Range 0.4 0.3 0.2 0.1 Typical Non Linearity Error for Far Range 0 1 2 3 4 5 Target Angle (Degrees) Gain Correction 1.02 1.015 1.01 1.005 Typical Gain Correction for Far Range 1 1 2 3 4 5 Target Angle (Degrees) Target ing - For proper operation a well grounded target is required for single probe applications and most multiple probe operations. The series 2800 probes have a built in ground line. A conductive path from the target to the clamp region or attachment point will provide adequate grounding. ing to earth or grounding to the equipment case are also acceptable. Note that ground loops or other grounding inadequacies can cause Custom Calibration - Custom calibration is available and longer ranges are available. The result of a longer range is a decrease in resolution and linearity. Repeatability, however, remains excellent which makes extended ranges ideal for servo applications and the non linear response can be modeled with modern computer software. Consult your Microsense representative for more information.

Technical Notes Resolution - Probe resolution is specified as the RMS value of the noise of the gages output signal. Peak to peak resolution will be about 3 to 6 times this value. Resolution is a function of the size of the sensor, the range, and filter bandwidth. The resolutions specified in the preceding page are measured at nominal standoff (mid point of the range. Resolution at the far end of the range will be about 1.5 times this value and at the near end of the range about 0.5 times this value. Linearity - All capacitive gauges have small non linearities over their full scale range. A feature of Microsense passive gauges is that this non linearity is highly repeatable. Cable Fixtures - The cable of the 2800 series probes form an integral part of the probe. When routing the cable bends with a radius of less than 10 mm (3/8 in) should be avoided. Rolling bends with radii of less than 75 mm (3 in) should be avoided. Use of excessive force in holding the cables or other actions that can cause abrasion or excessive wear should be avoided. For maximum reliability the cables should be secured 25 mm to 75mm (1-3 inches) from the probe. Cables should not be clamped in areas where there is active flexing Cable Length - The standard length of the cable on a 2800 series probe is 3 meters (approx. 10 ft). Alternative lengths are available. Because the cable forms a part of the overall capacitive structure of the probe changes in cable length will cause changes in resolution. Shorter cables will yield better resolution and longer cables will yield worse resolution. Consult your Microsense Representative for more information. Vacuum Compatibility - Probes with a V designation are designed for Vacuum Compatibility. These probes are made with vacuum compatible materials to assure low/no outgassing. Standard Vacuum compatible probes come with 2 cables. The exterior cable connects the gauge electronics to a vacuum feed through connector. This cable is 2 meters long. The standard length of the probe cable inside the vacuum chamber is 1 meter but may be configured by the customer. The system requires a fully shielded, floating shield bulkhead connector. The preferred connector is a double ended BNC type but others can be provided. Ultra High Stability - The standard 4810 offers excellent long term stability. For the most demanding applications where stability is measured in days and nanometers Microsense offers a 4810 HS (High Stability) Gauge and probes with the HS marking. These systems undergo special long term testing to assure that any long term drift is constrained to acceptable parameters. Microsense recommends you discuss your requirements with your representative if you have a requirement in this area. Custom Probes: Custom probes are available consult your Microsense Representative for more information. Microsense LLC. 70 Industrial Ave E. Lowell, MA 01852 USA Tel: 978-843-7670 Fax 978-856-3375 e-mail: sales@adetech.com Web Page Microsense LLC. (specifications subject to change without notice) REV 092804