FEMTO LDV Z8 IMAGE-GUIDED SURGERY ENHANCE YOUR SURGICAL PLANNING

Similar documents
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

AHEAD Superior technology, thoughtfully designed with you in mind for an intelligent approach to cataract surgery.

ifs 150 khz IntraLase Technology

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

OPHTHALMIC SURGICAL MODELS

MEL 80 Excimer Laser. When you want to see better performance

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Contents. Corneal Markers, Scleral Depressors

What you should know about LASIK and Femto-LASIK Understanding Laser Vision Correction. Patient information

Mastering The Techniques Of LASIK, EPILASIK And LASEK: Techniques And Technology

Overview of Commercially Available Femtosecond Lasers in Refractive Surgery

case report Scleral lens fit based on OCT data

Health Science 1110 Module 9 Sensations LAB 9. View the Film on Cornea Transplant and answer the questions on your laboratory worksheet.

ioct Discover the next generation of efficiency enhancement

Refractive Power / Corneal Analyzer. OPD-Scan III

HIGH DEFINITION VISION SOLUTIONS THE COMPLETE GUIDE TO LASER VISION CO R R EC T I O N

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

Multifocal and Accommodative

EXPAND YOUR VIEW. SUSTAIN YOUR ACCESS. OASIS IRIS EXPANDER DESIGNED FOR SAFETY & EFFICIENCY. PREMIER EDGE SAFETY SCALPELS SAFETY CRESCENT SCALPEL

Dawn of a New Era Modern LASIK Results. Christopher L. Blanton, MD April 28, 2018

Unique Aberration-Free IOL: A Vision that Patients

SCHWIND AMARIS. We have redefined perfection for you

OPHTHALMIC SURGICAL MODELS

LASIK & Refractive Surgery

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

Basic Principles of the Surgical Microscope. by Charles L. Crain

OCULUS Pentacam AXL Always an Axial Length Ahead

ATLAS Corneal Topography System

Subjective refraction OPTICS OF HUMAN EYE & REFRACTIVE ERRORS

SCHWIND eye-tech-solutions International Distributor Meeting Friday, 16th September 2011, 3:00 6:00 p.m. Hotel Sofitel Vienna Stephansdom

Title: Live volumetric (4D) visualization and guidance of in vivo human ophthalmic surgery with intraoperative optical coherence tomography

PRE-PLACED VERSUS POST-PLACED CORNEO-SCLERAL

Table of contents. 5 Swiss precision for clear vision. 6 What types of defective eyesight are there? 8 What is refractive eye surgery?

Long-term quality of vision is what every patient expects

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

ROTATIONAL STABILITY MAKES THE DIFFERENCE

GETTING STARTED WITH DMEK

The Dysphotopsia Mystery. John J. Bussa, M.D.

FOR PRECISE ASTIGMATISM CORRECTION.

FEA of Prosthetic Lens Insertion During Cataract Surgery


Axsun OCT Swept Laser and System

ISO Ophthalmic optics and instruments Instruments to measure axial distances in the eye

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Is LASIK the best choice for me? LASIK AND LASIK-LIKE PROCEDURES

MEDICAL & LIFE SCIENCES

Treatment of Presbyopia during Crystalline Lens Surgery A Review

OCULUS Keratograph 4. Topographer. We focus on progress

When I began my career as an ophthalmologist,

How to get a good centration during SMILE?

Principles and clinical applications of ray-tracing aberrometry (Part II)

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

In the following diagram the parts of the eye are visualized and labeled for you.

Laser Glasses

Digital Wavefront Sensors Measure Aberrations in Eyes

Vision Science I Exam 1 23 September ) The plot to the right shows the spectrum of a light source. Which of the following sources is this

4/2/2015. Bonnie An Henderson MD Clinical Professor of Ophthalmology Tufts University School of Medicine Ophthalmic Consultants of Boston

NIDEK ADVANCED VISION EXCIMER LASER SYSTEM

Femtosecond Lasers in Ophthalmology

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

THE ASPHERIC PRELOADED INJECTION

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

Optical Path Difference Scanning System OPD-Scan II ARK-10000

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

The Aberration Structure of the Keratoconic Eye

Our vision is foresight

Glossaries APPENDIX. Eye Care Glossary ALIC FIELD GUIDE

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Schwind Amaris 1050 Smart Pulse Technology

New Materials for Perfect Vision

Research Article Effect of 60 khz and 150 khz Femtosecond Lasers on Corneal Stromal Bed Surfaces: A Comparative Study

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Technicians & Nurses Program

PSY 214 Lecture # (09/14/2011) (Introduction to Vision) Dr. Achtman PSY 214. Lecture 4 Topic: Introduction to Vision Chapter 3, pages 44-54

MrN Physics Tuition in A level and GCSE Physics AQA GCSE Physics Spec P3 Optics Questions

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

Advanced Technology IOLs

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

Going beyond the surface of your retina OCT-HS100 OPTICAL COHERENCE TOMOGRAPHY

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

Customized Lasers for Specific Swept Source OCT Applications. Bill Ahern Axsun Technologies, Inc. June 20, 2013

BIONIC EYE. Author 2 : Author 1: P.Jagadish Babu. K.Dinakar. (2 nd B.Tech,ECE)

Virtual Reality Phacoemulsification: a Comparison Between Skilled Surgeons and Students Naive To Cataract Surgery

Adaptive Optics Phoropters

Chapter 6 Human Vision

edge of the section wound, probably from opening of the wound

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

Guide to the Patricia Bath Innovative Lives Presentation and Interview, [videotapes]

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

sclera pupil What happens to light that enters the eye?

Subjective refraction

Visual Optics. Visual Optics - Introduction

Transcription:

FEMTO LDV Z8 IMAGE-GUIDED SURGERY ENHANCE YOUR SURGICAL PLANNING

FEMTO LDV Z8 OCT applications OCT APPLICATION: CATARACT Enhanced planning and customized individual treatments High resolution OCT images of the lens and cornea help you to fine-tune the resection geometries before a treatment. Other features of our proprietary OCT-System include: Automatic edge detection (pupil, limbus, cornea, lens, iris) Automated suggestions for the placement of the resection geometries based on the individual surgeon s preferences All trajectories can be customized by the surgeon after docking «Look deep into nature, and then you will understand everything better.» Albert Einstein OCT image used in incision planning The high-resolution OCT image reveals subtle structures such as cortical cataracts The automatically placed trajectories can be customized after docking.

OCT APPLICATION: CORNEA See what was previously hidden Our OCT enables enhanced surgical planning and customization after docking. Visualization of Bowman s membrane for Sub-Bowman LASIK flap. Check the applanation via imaging Visualization of subtle structures like the epithelium and the Bowman s membrane Previous LASIK-flaps and other abnormalities like corneal scaring can be seen and the treatment adjusted accordingly An OCT scan of the donor tissue allows for enhanced surgical planning and customization «Vision is the art of seeing what is invisible to others.» Jonathan Swift

LIVE TOP VIEW IMAGE A picture is worth a thousand words. Proverb High definition images for tailor-made surgery The integrated high definition camera enables better visual control and simplified docking. Benefits include: Detailed high quality color image (24 bit) Optics optimized for cornea and lens applications Automatic detection of pupil and limbus Live top view image between the different steps of the cataract pre-treatment The automatic detection of pupil and limbus is robust against color markings The combination of OCT and top view images allows you the best possible planning and customization The top view image allows visualization of intraoperative events such as miosis

FEMTO LDV Z8 OCT applications I SPY WITH MY LITTLE EYE OCT advantages at a glance High definition images of the lens and the cornea Surgical planning assisted by OCT imaging Clear visualization of previous resections (e. g. LASIK-flaps or keratoplasties) and scars Increased planning options for thin resections of 80 microns and smaller Surgical planning is done in confidence with OCT and top view visualization «It s not what you look at that matters, it s what you see.» Henry David Thoreau The proprietary Ziemer OCT-system The Ziemer OCT system is designed and manufactured by Ziemer and highly specialized for corneal and lens applications. OCT-type: Wavelength: Scanning depth: Edge recognition: Spectral domain 880 nanometer 10 millimeter Automatic To have a proprietary OCT system brings many benefits. It is specifically built for the FEMTO LDV Z8. The system is open for innovative solutions and continuous improvements. The OCT system is directly integrated into the FEMTO LDV Z8 s hardware.

VERSATILITY THAT MEETS YOUR DEMANDS Modular architecture Adapted to your individual requirements Z2 Model Z4 Model Z6 Model Z8 Model Z-LASIK Z-LASIK Z Intracorneal Rings (ICR) Intrastromal Pocket (ISP) Lamellar Keratoplasty (LKP) Penetrating Keratoplasty (PKP) Clear Corneal and Arcuate Incisions (CCI / ARC) Z-CATARACT* Applanation patient interface Liquid patient interface *Lens fragmentation, capsulotomy and corneal incisions Standard software package Optional software package Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 2562 Port, Switzerland +41 32 332 70 70 innovation@ziemergroup.com www.ziemergroup.com www.femtoldv.com Ziemer USA, Inc. a Ziemer Group Company 620 E. Third Street Alton, Illinois 62002, USA +1 618 462 9301 usa@ziemergroup.com Ziemer Ophthalmology (Deutschland) GmbH a Ziemer Group Company Im Hausgrün 15 79312 Emmendingen, Germany +49 7641 9333860 info-deutschland@ziemergroup.com Issue Date: 2016-08 REF 510.931.019 Doc. No. FL5940-0543-01 Find us on YouTube: www.femtoldv.com/youtube The FEMTO LDV Z2, Z4, Z6 and Z8 are CE marked and FDA cleared. For some countries, availability may be restricted due to regulatory requirements; please contact Ziemer for details.