Medical Grade AC/DC Power Supply With PFC

Similar documents
Medical Grade AC/DC Power Supply With PFC

Medical Grade AC/DC Power Supply With PFC

C B. Models. Models 2MOPP

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Electrical Specifications

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

LB115S 115W Single Output

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

150 Watt Industrial (WLT)

LFWLP W 12V 15.00A 25.00A 92%

General. Environmental. EMC & Safety

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

General. Environmental. EMC & Safety

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Electrical Specifications

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Output Full Load

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

VOF XX - XXX - X

Output Voltage* (nom.)(adjustable)

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Technical Specification ACLF060HTx230. AC Lin. ACLF060HTC230RS-G Module. 85 to 264Vrms 9Arms 115Vrms 100ºC +100ºC

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

-80 to +80V 20A 100ºC 250kHz. Input Output Current Max DC Resistance Differential Attenuation

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Load (2) Single or Dual

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Industrial Serie +600S

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Metal Case Power Supplies

Electrical Specifications

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

For more information, please visit the product page. output. output current max (A)

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

IEC/EN/UL60950 & CE certified, EN55032 Class B

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

TB65 65W Single Output Test and Measurement/Industrial Series

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

Load (2) Single or Dual

Electrical Specifications

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

Watts HCP Series

MB120S 120W Single Output Medical Series

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

FED30-48 S 05 - N HC Series Name Input Output Output Remote Control Assembly Option Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

FED30-48 S 05 W - N HC Series Name Input Output Output Input Remote Control Assembly Option Voltage Quantity Voltage Range Option

Voltage Adjustment. Load Regulation

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Military COTS AC Line Filter

TE60 60W Single Output External Power Test & Measurement/Industrial Series

COTS EMI FILTER -500V

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

TE W Single Output External Power Test & Measurement/Industrial Series

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

PM24S/DR24S series 60W Single Output DC/DC Converter

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

CP-T range Product group picture

Transcription:

Technical Specification 1400 W Single Vout Series Medical Grade AC/DC Power Supply With PFC -264 Vrms 12/15/24/28/48 V 1400 W 10 W Up to 92 % Input Voltage Semi-Regulated Output Output Continuous Output Transient Full Load Efficiency 4. " 7" Product Features High efficiency (92% for 48 Vout Model at 1400 W) Universal input voltage range Semi-regulated output for bus stability Integral fan cooling with speed control Active PFC; EN60-3-2 compliant Low leakage; EN60601-1 compliant Low noise; EN55011 / EN55022 Class B compliant Medical EMI Compatibility: IEC 60601-1-2 ed 4.0 compliant Product # AQ1400M4xx Phone 1-888-567-96 Over current, over voltage, & over temp protection DC Power Good / AC Power Good signals Remote enable input Fan status output Small size: 4." x 7" x 1.625" (encased) RoHS 6/6 compliant 5 V (500 mw) standby output www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 1

ACuQor 1400 W Series Electrical Characteristics All specifications typical with T A = 25 C, unless otherwise specified. Specifications subject to change without notice. MAIN OUTPUT SPECIFICATIONS Output power (continuous) -132/1-264 Vrms (5 s transient) -132/1-264 Vrms 132-1 Vrms Nominal DC output voltage (at 250W) (Semi-regulated) Efficiency (see figs. 1, 3, 5, 7) Hold-up time (to -20%) 12 Vout 24 Vout 36 Vout 48 Vout 12 Vout,, 1400 W 24 Vout,, 1400 W 48 Vout,, 1400 W 12 Vout,, 1400 W 24 Vout,, 1400 W 48 Vout,, 1400 W 12 Vout 24 / 36 / 48 Vout Maximum load capacitance 12 Vout 15 Vout 24 Vout 28 Vout 48 Vout Output ripple voltage Switching frequency (20 MHz BW) Twice line frequency (at 0W) Turn-on delay 1400 W 10 W See Figure 12 12.4 V 25 V 37.5 V 50 V 87% typ. 89% typ. % typ. 89.5% typ..5% typ. 91.5% typ. 16 ms @ 1400 W 20 ms @ 1400 W 48,000 μf 40,500 μf 24,000 μf 19,200 μf 6,000 μf 0.5% p-p 5.0% p-p 2 s max. Transient response Iout steps from 50-% 3% typ / 6% max. dev. At 0.2 A/µs ms recovery Overvoltage protection Cyclic restart 110-120% Short circuit protection Cyclic operation 115% rated Iout Total regulation Over line, load and temperature ±6.0% Auxillary Output Always on (See Note 1) 5 V @ ma Thermal protection Automatic recovery +125 ºC (PCB Temp) REMOTE_ENABLE Input Low Voltage Input High Voltage 0.45 V (max) 4.15 V (min) INPUT SPECIFICATIONS AC input voltage Universal range -264 Vrms Input frequency 47-63 Hz ENVIRONMENTAL CHARACTERISTICS Thermal performance Operating ambient (see Figure 9) Non-operating ambient 0 ºC to + ºC -40 ºC to + ºC Relative humidity Non-condensing 5-% RH Altitude Operating 10,000 ft max. Non-operating 30,000 ft max. Random vibration 5-500 Hz 0.03 g2/hz Shock Half-sine, 10 ms, 3 axes 20 g peak EMC CHARACTERISTICS Conducted emissions EN55011 and EN55022, FCC part15 Level B Line frequency harmonics EN60-3-2 Class A Voltage fluctuations EN60-3-3 Clause 5b ESD air EN60-4-2 Level 4, +/-15kV See following details Perf Criteria A, AC Input Connections Perf Criteria B, DC Output Connections ESD contact EN60-4-2 Level 4, +/-8kV Perf Criteria A; HCP, VCP, Case Radiated immunity EN60-4-3 Level 3, 10V/m IEC60601-1-2 Ed.4 Table 4 28 V/m IEC60601-1-2 Ed.4 Table 9 Perf Criteria A Fast transients EN60-4-4 Level 3, KHz rep, AC input leads IEC60601-1-2 Ed.4 Table 5 Perf Criteria A Line surge immunity EN60-4-5 Level 3 Conducted immunity EN60-4-6 Level 3 Power freq. mag. field EN60-4-8 30 A/m IEC60601-1-2 Ed.4 Table 4 Perf Criteria A Input current @ 1400 W 14 Arms Voltage dip immunity EN60-4-11 0% Ut; @ 1400 W 7 Arms See following details 0.5 cycle 45 increments Power factor >0.98 0% Ut; 1 cycle Input surge current 264 Vrms (cold start) 50 A max. % Ut; 0.5s Internal input fuses Both AC lines 20 A IEC60601-1-2 Ed.4 Table 5 GENERAL SPECIFICATIONS Perf Criteria A, Load Dependent Fundamental ripple freq. Input 500 khz Output 250 khz Voltage interruptions EN60-4-11 0% Ut; 5s Audible noise Weight ( AQ00xxxxGC ) Fan speed varies with temp. 45 dba @ 1 m max. 998 g (35.2 oz) IEC60601-1-2 Ed.4 Table 5 Perf Criteria B Weight ( AQ1xxxxGC ) 1179 g (41.6 oz) NOTES: Weight ( AQ1400xxxxGC ) 1179 g (41.6 oz) MIL-217 533 khours 1. Derate 1 ma per C above 50 C ambient temperature. MTBF Demonstrated TBD khours 2. Leakage currents see following table. ISOLATION SPECIFICATIONS Isolation voltage Input to output 4000 Vrms Input to ground 1500 Vrms Output to ground (B) 500 Vrms Output to ground (BF & CF) 1500 Vrms Output to ground (CFD) 5000 Vpulse Insulation resistance Output to ground 10 MΩ min. Leakage currents See Note 2 Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 2

EMC Immunity Testing Details ESD EN60-4-2 For ESD tests applied directly to the DC output, one of the methods called out in IEC 60-4-2 section 7.1.3 must be used to bleed off charge between successive ESD events. For example, the cable with 2 x 4kOhm resistors used for this purpose during coupling plane tests can be duplicated and connected from DC output to protective earth (PEGND). Discharges must not be applied directly to any circuits other than the case (for encased models), the AC input connections, and the DC output connections. For ESD protection in equipment, it is important to follow the ACuQor Installation Instructions provided with each unit in regards to clearance. Those instructions are repeated here for emphasis. CF and CFD models, in particular, may experience high DC output voltages with respect to protective earth (PEGND) due to their low capacitance/low-leakage design if ESD pulses are directly applied. Maintaining adequate clearance will prevent arcing from ACuQor DC output circuitry to other user circuits and chassis. Voltage Dips EN60-4-11 The following table details the DC output loading conditions and performance criteria for AC input voltage dip tests. ACuQor 0/1/1400W Performance Test Condition DC Load Criteria 0% UT; 0.5 cycle at 0, 45,, 135, 1, 225, 2 and 315 degrees 0 to 1 W A > 1 W B 0% UT; 1 cycle at 0 degrees 0 to 0 W A > 0 W B % UT; 25/30 cycles (0.5s) at 0 degrees 0 to 1 W A >1 W B 0% UT; 250/1 cycles (5s) at 0 degrees All loading B Note: 1W models limited to 1300W transients Leakage Currents AC Leakage Current from Input to Earth ACuQor Typical at 110% nominal input voltage 60 Hz AC Line Connection Normal Condition Open Neutral Fault AC Leakage Current from Output to Earth Model Normal Condition Open Earth Fault AC Backdrive Fault 240 V L-N, 1 phase 220 µa 440 µa AQ.. B... 4 µa µa 208 V L-L, 120 V L-N, 1 of 3 phases 120 µa 240 µa ACuQor Typical at 264 Vac 60 Hz input AQ.. BF.. 4 µa 40 µa 78 µa 240 V L-N-L, 120 V L-N, split phase 120 µa 240 µa AQ.. CF.. 4 µa 20 µa 39 µa For convenience, the following tables show limits allowed by various standards: AC Leakage Current from Input to Earth Maximum Allowed per Standard Standard Normal Open Neutral AC Leakage Current Condition Fault from Output to Earth Contact Type Normal Open Earth AC Backdrive Condition Fault Fault IEC60601-1 500 µa 0 µa B µa 500 µa NFPA 99 2005 300 µa Maximum Allowed per IEC60601-1 BF µa 500 µa 5000 µa IEC600 3500 µa CF 10 µa 50 µa 50 µa Table 1: Leakage Currents Standard Testing Certifications SAFETY AGENCY CERTIFICATIONS UL 60601-1 CAN/CSA C22.2 No. 601.1-M EN 60601-1 IEC 60601-1 ANSI/AAMI ES60601-1 CE Marked Meets NFPA 99 2005 300 μa earth leakage Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 3

CONNECTOR DETAILS 8 OUTPUT CONNECTOR PINOUT Pin 1 Reserved Reserved for future use. 1 2 Pin 2 Reserved Reserved for future use. Pin 3 VOUT( ) Negative Output Voltage. Pin 4 REMOTE_ENABLE Logic input. See Figure B. Pull high to enable main output. Pin 5 FAN_GOOD Open collector with internal 5 V pullup. See Figure A. Pulsed low on fan failure, ms, 50% duty Pin 6 AC_POWER_GOOD Open collector with internal 5 V pullup. See Figure A. Pulled low on AC power dropout. Pin 7 DC_POWER_GOOD Open collector with internal 5 V pullup. See Figure A. Pulled low during startup ramp and within 5ºC of temperature shutdown threshold. Pin 8 5V_STANDBY 5 V @ ma available whenever AC power is applied. Figure A: Power good and fan good interface circuitry. 8 1 Figure B: Remote enable interface circuitry OUTPUT CONNECTOR PINOUT Pin 1 VOUT(+) Positive Output Voltage. Pin 2 VOUT( ) Negative Output Voltage. Pin 3 VOUT(+) Positive Output Voltage. Pin 4 VOUT( ) Negative Output Voltage. Pin 5 VOUT(+) Positive Output Voltage. Pin 6 VOUT( ) Negative Output Voltage. Pin 7 VOUT(+) Positive Output Voltage. Pin 8 VOUT( ) Negative Output Voltage 1 3 INDIVIDUAL INPUT CONNECTOR PINOUT Pin 1 Ground Pin 3 Pin 5 AC Neutral AC Line MATING CONNECTORS Connector Type Contact OUTPUT (Power) Positronic PLA08M7 Positronic MS112N OUTPUT (Data) Molex 43025-0810 Molex 430300008 INPUT Hirose DF22B-3S-7.92C Hirose DF22A-1012SC Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 4

EFFICIENCY, DERATING, AND VOUT DROOP CURVES Figure 1: 12 V OUT Figure 2: 12 V OUT Figure 3: 15 V OUT Figure 4: 15 V OUT Figure 5: 24 V OUT Figure 6: 24 V OUT Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 5

EFFICIENCY, DERATING, AND VOUT DROOP CURVES Figure 7: 28 V OUT Figure 8: 28 V OUT Figure 9: 48 V OUT Figure 10: 48 V OUT Power (W) 1600 1500 1400 1300 1200 1 0 0 0 0 600 500 400 300 200 0 0 10 20 30 40 50 60 Ambient / Case Temperature (ºC) Power (W) 2000 10 1600 1400 1200 0 0 600 400 200 0 110 140 105 132 1 1 Input AC Voltage (V RMS ) Transient Continuous 264 Figure 11: Continuous power derating curve in natural convection. Figure 12: Rated output power vs Input AC Voltage. Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 6

MECHANICAL DRAWINGS.19 PLASTIC RIVET OD. [ 4,8 ] 6-32 SELF CLINCHING INSERT MOUNTING SCREW SHALL NOT PROTRUDE 3/8" INTO THE CHASSIS x4 7.00 [177,8] 6.63 [168,3] 6.60 [167,6 ] 4.30 [109,2]. [19,1 ] 2.28 [57,8 ].20 [5,1 ].16 [4,1 ].25 [6,4 ] 4.25 [108 ] 4. [120,7].51.03 [13 0,7] 4.84 [123 ] FRONT VIEW.62.03 [15,8 0,7] 1.63 [41,3] 1.03.04 [26,1 1 ] BACK VIEW 1.31.03 [33,3 0,7] OUTPUT POWER PIN 1 3.47.03 [88,2 0,7] OUTPUT DATA PIN 1.89.03 [ 22,5 0,7] INPUT PIN 1 NOTES 1. Recommended screw tightening torque of 6in.. lbs. 2. Undimensioned components are shown for visual reference only 3. All dimensions in inches [mm] Tolerances: x.xx in ± 0.02 x.xxx in ± 0.010 Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 7

INSTALLATION INSTRUCTIONS GENERAL: ACuQor power supplies are intended for use as components in medical and industrial equipment. ACuQor units must be properly installed within end use equipment before they can be safely applied as described in this document. The suitability of the ACuQor/equipment combination must be verified through end product investigation. MOUNTING: Refer to the Mechanical Drawings section. ACuQor units are provided with threaded stainlesssteel stand-offs or inserts for mounting. This mounting hardware is internally connected to the input connector protective-earth terminal for functional-earth EMC control. Any orientation (vertical, horizontal, etc.) may be used. Adequate air space should be provided over the fan intake (top) and exhaust (sides) to allow for exchange of cooling air. ACuQor is designed for a pollution degree 2 environment. A minimum of 5 mm electrical clearance should be allowed from the connector ends of encased models. INPUT: Refer to the Connector Details section for input connector wiring. ACuQor products require a single phase AC power source of -240V 50/60Hz nominal. Refer to nameplate label for input current ratings. A protective-earth connection is also required. Minimum wire size of 14 AWG (2.5mm 2 ) is recommended. Both sides of the AC line are internally fused (see table for specific models). These fuses are not user replaceable. OUTPUT: Refer to the Connector Details section for output connector wiring and signal I/O functionality. Refer to nameplate label for output current ratings. Main DC output (Vout+, Vout-) pins should use 12 AWG (4.0mm 2 ) wire size. Individual main output pins should not be loaded to more than 30 A. For currents greater than 30 A, multiple main output pins/wires must be used in parallel. All signal I/O pins are referenced to Vout-. EMC: ACuQor products have been tested to the EMC specifications listed in the section of this datasheet titled Electrical Characteristics, on page two. However, end use equipment must be tested to verify EMC compliance. PATIENT CONTACT: ACuQor models include versions designed for B, BF and CF patient contact application per IEC60601-1. The BF and CF ACuQor models provide reinforced insulation at the DC output voltage level and basic insulation at the 240 Vac level from output to protectiveearth. Note that equipment and wiring may add to system leakage currents so that the end product must be tested for compliance. Refer to the Electrical Characteristics section for typical ACuQor input and output leakage currents. In addition, ACuQor defibrillation rated models comply with the minimum output to protective-earth creepage/clearance requirement and defibrillator pulse test of IEC60601-1. HIPOT TESTING: ACuQor products are rated for Hipot testing levels of 1500 Vac input to protective-earth, 1500 Vac output to protective-earth, and 4000 Vac input to output. When performing the 4000 Vac input to output test, the test voltage must be balanced evenly 2000 Vac input and output to protective-earth. Two oppositely phased test voltage sources or a single test voltage source with external balancing impedances (capacitors) may be used to prevent overstressing input or output to protective-earth insulation per IEC60601-1 2005 sub clause 8.8.1 and IEC60601-1 19 sub clause 20.4. CONDUCTIVE COOLING: This product requires supplemental conductive cooling through its case to maintain the rated output power. The case should be mounted to a system chassis or heat sink with a thermally conductive interface material and kept at 50 C maximum to maintain full power rating of the product. For detailed applications assistance, consult Applications Engineering through the sales channel. MODEL Input Fuses Fuses (in Both AC Lines) Total AQ00 Cooper Bussmann 20A 250V GBB-20 2 AQ1 Cooper Bussmann 20A 250V GBB-20 2 AQ1400 Cooper Bussmann 20A 250V GBB-20 2 Table 2: AC line fuses for specific ACuQor Medical Models Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 8

Ordering Information PART NUMBERING SYSTEM The part numbering system for SynQor s ACuQor AC/DC power supplies follows the format shown in the table below. Not all combinations make valid part numbers, please contact SynQor for availability. Family Output Power Grade Range Output Voltage Package Type Thermal Design Options AQ: ACuQor series of AC-DC semi-regulated output power supplies 00: 0 W 1: 1 W 1400: 1400 W M: (Medical) 4: 4th Generation EMC Universal (-264 VRMS) 12: 12 V 15: 15 V 24: 24 V 28: 28 V 48: 48 V G: (5"x7") C: Encased Medical Grade: BF: BF isolation rating CF: CF isolation rating CFD: CF isolation rating defibrilator proof Example: AQ1400M424GCBF ACCESSORIES SynQor offers a series of assemblies that can be ordered according to the table below. Mechanical drawings for these accessories are available for download in pdf format from the SynQor website. Part Number Description AQ-CBL-INPUT1CG Input mating cable with pre-stripped wire ends (36 long). AQ-CBL-OUT1CDG Output mating cables with pre-stripped wire ends (18 long). APPLICATION NOTES A variety of application notes and technical white papers can be downloaded in pdf format from the SynQor website. Online Application Notes Online Library of Technical White Papers SynQor website. Contact SynQor for further information and to order: Phone: 978-849-0600 Toll Free: 888-567-96 Fax: 978-849-0602 E-mail: power@synqor.com Web: Address: www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA PATENTS SynQor holds numerous U.S. patents, one or more of which apply to most of its power conversion products. Any that apply to the product(s) listed in this document are identified by markings on the product(s) or on internal components of the product(s) in accordance with U.S. patent laws. SynQor s patents include the following: 5,999,417 6,222,742 6,545,8 6,594,159 6,894,468 6,896,526 6,927,987 7,050,309 7,072,1 7,0,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,2 7,7,687 7,787,261 8,023,2 8,149,597 8,493,1 8,644,027 9,143,042 WARRANTY SynQor offers a two (2) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Product # AQ1400M4xx Phone 1-888-567-96 www.synqor.com Doc.# 005-00066 Rev. D 08/24/17 Page 9