Endura-Classic Craftsman Information

Similar documents
PVC Column Wraps - Semi-Assembled INSTALLATION INSTRUCTIONS

Craftsman Style Columns. Ease of installation Interior or exterior use Quick Ship from inventory Made-to-Order services CAD drawings / shop drawings

Inteplast Trim Free Foam

Endura-Stone Installation Instructions

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

Column Wraps. Column Wraps are non-structural. Pressure-treated posts not included.

SECTION PLASTIC FABRICATIONS PART I GENERAL 1.01 SECTION INCLUDES

Make every component count.

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Shapes Siding. Perfection Shingles. Chalk Line

SECTION SIMULATED WOOD TRIM. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

AZEK Trim & Moulding Install Guide

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Pocket Door Installation Instructions

TURNCRAFT ARCHITECTURAL COLUMN INSTALLATION INSTRUCTIONS

Dura-Lock Roof System

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

Balustrade Systems / Installation Instructions

Exterior Moulding & Trim Special Order Items. royalbuildingproducts.com Royal Building Products

Best Barns USA Assembly Book

Salter Industries Spiral Stair

How To Install Windows: Nail-Fin Application

CUSTOM SHUTTERS IN-A-BOX

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

Installation Instructions for. Before You Begin TOOLS REQUIRED

INSTALLATION INSTRUCTIONS MILLENNIUM DECKING Before Installing Millennium Decking, please read these instructions in their entirety.

Installation Guide - Evolution Series Wood Siding

DECKING INSTALLATION GUIDE

Chapter 17 - Porch Trim

ARCHITECTURAL GRADE PVC

Ash Brook Golf Course Scotch Plains, New Jersey

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

Section 914. JOINT AND WATERPROOFING MATERIALS

CFDTT-01. Control Joint Study (General)

INSTALLATION GUIDE. Biowood Outdoor Wall Panel BWWPO20018 Shiplap 8x6 Deep. Green Resources Material Australia Pty Ltd

Canadian Product Spec Guide

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

8/7/ HP SWING DOOR INSTALLATION INSTRUCTIONS

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING

Bird Feeder BUILD TIME

Balustrade System Installation - Cambridge & Huntington

Panel Installation Instructions

PREPARATION & TOOL CHECK LIST

Installation Guide. Shingles. Classical. Shingles. Warning. Storage. Cutting Shingles. Touch-Up. Eastern White Cedar

INSTALLATION INSTRUCTIONS

Installation Instructions Palladium Square Edge Panels

Installation Instructions for easy to install Texture Plus faux wall panels

KuraStone TM Installation Guide

Harvest (8094) Mystic (8078) Niagara (8095) Shenandoah (8057) 2 DURATA MORTARLESS STONE DURATA FLAT KIT PROFILE #:

SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

POCKETING MULTI-SLIDE DOOR SYSTEM

STACKING MULTI-SLIDE DOOR SYSTEM

Related Articles: Index of Siding and Exterior Trim Articles Index of Window Articles

INTEX Millwork Solutions SECTION EXTERIOR PVC PERGOLAS (IBC Compliant)

Balustrades & Columns

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Vinyl Windows Manufactured by VPI Quality Windows

Cabonyx Installation Manual

SECTION SHEET METAL FLASHING AND TRIM

HOW TO INSTALL ELITE PANELED WAINSCOTING Using X-Rails with Either Raised, Flat or Beaded Panels

COMPOSITE SIDING INSTALLATION GUIDE

The look of wood. The ease of low maintenance.

INSTALLATION GUIDE. 5" Balustrade System

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

DESIGNER SERIES GUTTER SYSTEM INSTALLATION INSTRUCTIONS

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Tools required by installer: Materials required by installer:

INSTALLATION MANUAL STORAGE

Sawn Baluster Sizing and Installation Guide

How to Install Elite Bayside Beadboard

Installation guide. MS 14 Metal Siding

GENERAL INSTALLATION GUIDE: WARRANTY: PRODUCT INFORMATION T F

CXT PRO RAILING INSTALLATION INSTRUCTIONS For Installations Using Aluminum and Glass Balusters Sold Separately

Stone coated steel roof tile INSTALLATION GUIDE

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

Tape Measure Metal Clippers Screw Bit Set With Extensions

PRIVACY INSTALLATION FOR: Standard 6 H x 8 W Privacy Fence 4 x 4 Post Sleeve & Brackets Dog Ear or Straight-Edge Pickets 1.75 x 3.

Manufactured by Reynolds Building Systems, Inc.

Best Barns USA Assembly Book

Vinyl Gazebo Instructions

Installation Instructions Palladium Wall Panels - Demountable Factory Finished Edges and Field Cut Edges

Best Barns USA. Assembly Book. 12'x 16' the Millcreek. Revised September 19, 2017

Best Barns USA Assembly Book

Installation Guidelines EX-Cel & NuCedar PVC Trim, Sheet & Moulding

Best Barns USA Assembly Book

Best Barns USA Assembly Book

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

Best Barns USA Assembly Book

installation manual m y w a l l a r t. c o m

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

SHEET METAL FLASHING AND TRIM Christ on the Mountain

Installation Guide. Deckorum. Composite Decking

Panel Installation Instructions

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

NX7 SERIES 5-1/2 HANDRAIL

2. Sanding the Modules Sand the entire surface of each cyc module with 60-grit sandpaper. This will provide for better paint adhesion.

SECTION Plastic Simulated Wood Trim SIMULATED WOOD TRIM PART 1 GENERAL 1.1 SECTION INCLUDES

Transcription:

Endura-Classic Craftsman Information Endura Classic Craftsman Series Columns have a Limited Lifetime Warranty against rot, corrosion and moisture damage. Endura Classic Craftsman Series Columns are manufactured using expanded cellular PVC and can be trimmed, fastened and drilled with ordinary woodworking tools. Endura Classic Craftsman Series Columns must be painted with two coats of acrylic latex paint applied according to the paint manufacturer s instructions. Columns that are installed in direct sunlight will perform best when painted with light colors to minimize thermal gain that can cause warping. Endura Classic Craftsman Series Columns are manufactured using our E-Z Lock Miter Joint that aids in assembly, aligning the corners for a perfect fit and keeping the column square. If installing in cold temperatures (less than 50 degrees) pre-drilling is required before using fasteners. Cellular PVC becomes more brittle in cold temperatures and can be damaged if care is not taken during installation. If repair is required any two part epoxy or two part body filler will work well. Coarse thread galvanized sheetrock or decking screws work best to fasten cellular PVC. Pin nailing will also work well when using non-corrosive pin nails with larger heads. 100% waterproof polyurethane adhesive works well to assemble Endura Classic Craftsman Columns. Endura Classic Craftsman Series Column shafts are 3/8 under nominal width and 1/2 under nominal length. Columns are shipped KD to aid in assembly around a structural post and to allow for field trimming. To provide a custom fit, Non-Tapered Plain Columns can be trimmed to any length. Non-Tapered Fluted and Raised Panel Columns can be trimmed up to 6. Tapered Plain Columns can be trimmed up to 12 and Tapered Raised Panel columns can be trimmed up to 6. Tapered Columns must be trimmed from the bottom only and will change the reveal on the base. The base can then be trimmed to match the reveal of the cap or left as is. The Tapered Column base detail is shipped loose and is applied after the column is trimmed and installed and the caps for Tapered Columns come assembled. Caps and bases for Non-Tapered columns are shipped loose and simply wrap around the column. Endura Classic Craftsman Series Columns are not load bearing and require a load bearing structure in place before installation. If a wood post is used it must be pressure treated. Columns should be trimmed 1/4 shorter than the opening to allow for expansion. ASTM DESIGNATION TEST TITLE Results D256 IZOD Impact Resistance 0.246 ft. lb/in. Width D570 Water Absorption (24 Hour exposure) 0.50% D635 Rate of Burn Failed to Ignite Tensile Strength 1,889 psi D638 Modulus of Elasticity 107,000 psi Elongation 10.20% D648 Heat Deflection Temperature under Load 153 F D696 Coefficient of Linear Thermal Expansion 0.0000327 in/in F D790 Flexural Strength 4019 psi D792 Specific Gravity / Density 0.55 g/cc Fastener Withdrawal - 2" Staples 69 D1761 Fastener Withdrawal - 1" #10 Wood Screw 422 Fastener Withdrawal - 2" Galvanized Nails 1 08 D5420 Impact Resistance (Drop Dart) 98 E84 Surface Burn Characteristics 20

Endura-Classic Craftsman Description Endura Classic Craftsman Series Columns have a Limited Lifetime Warranty against rot, corrosion and moisture damage. Endura Classic Craftsman Series Columns are manufactured using expanded cellular PVC and can be trimmed, fastened and drilled with ordinary woodworking tools. Endura Classic Craftsman Series Columns must be painted with two coats of acrylic latex paint applied according to the paint manufacturer s instructions. Columns that are installed in direct sunlight will perform best when painted with light colors to minimize thermal gain that can cause warping. Endura Classic Craftsman Series Columns are manufactured using our E-Z Lock Miter Joint that aids in assembly, aligning the corners for a perfect fit and keeping the column square. If installing in cold temperatures (less than 50 degrees) pre-drilling is required before using fasteners. Cellular PVC becomes more brittle in cold temperatures and can be damaged if care is not taken during installation. If repair is required any two part epoxy or two part body filler will work well. Coarse thread galvanized sheetrock or decking screws work best to fasten cellular PVC. Pin nailing will also work well when using non-corrosive pin nails with larger heads. 100% waterproof polyurethane adhesive works well to assemble Endura Classic Craftsman Columns. Endura Classic Craftsman Series Column shafts are 3/8 under nominal width and 1/2 under nominal length. Columns are shipped KD to aid in assembly around a structural post and to allow for field trimming. To provide a custom fit, Non-Tapered Plain Columns can be trimmed to any length. Non-Tapered Fluted and Raised Panel Columns can be trimmed up to 6. Tapered Plain Columns can be trimmed up to 12 and Tapered Raised Panel columns can be trimmed up to 6. Tapered Columns must be trimmed from the bottom only and will change the reveal on the base. The base can then be trimmed to match the reveal of the cap or left as is. The Tapered Column base detail is shipped loose and is applied after the column is trimmed and installed and the caps for Tapered Columns come assembled. Caps and bases for Non-Tapered columns are shipped loose and simply wrap around the column. Endura Classic Craftsman Series Columns are not load bearing and require a load bearing structure in place before installation. If a wood post is used it must be pressure treated. Columns should be trimmed 1/4 shorter than the opening to allow for expansion.

Endura-Classic Craftsman Non-Tapered Install Sheet 1) Measure overall opening from floor to beam or soffit (must have structural pressure-treated post or lally column for load support.) 2) Install blocking around load bearing post (use pressure treated lumber.) Final width of blocking must be same width as inside of column. 3) Install blocking around center and top of post to match step 2. (Center blocking is optional.) Blocking may be attached to deck/soffit instead of post if necessary. 4) Trim shaft pieces at least ¼ shorter than opening height (from step 1). Trim ONLY from bottom - top end is marked. 5) If you are going to use screws, pre-drill/countersink all panels. See joint diagram on next page to determine which edge to pre-drill. 6) Lay 3 panels flat and apply adhesive to center joints. (Polyurethane glue is recommended. Follow manufacturers instructions.) 7) Assemble three panels, using E-Z lock joints. 8) If using screws, assemble three panels together using coarse thread galvanized screws (deck screws.) 9) Or if you are not using screws, finish nail three panels together. 10) Place the partially assembled (3 panels) column around post and blocking. 11) Apply adhesive to final panel and attach to shaft using E-Z Lock joints. 12) Screw or nail final panel in place.

Endura-Classic Craftsman Non-Tapered Install Sheet 13) Screw or nail column to blocking ONLY ON THE BOTTOM. Do not attach at center or top (to allow for expansion.) 14) Apply adhesive to mitered ends of base moulding (9¼ tall) and assemble around bottom of column shaft. 15) Fasten joints on base with screws or nails. 16) The TOP of the shaft should NOT be fastened to the blocking, and there should be at least ¼ gap to allow for expansion (see step 4.) 17) There are TWO methods of attaching the cap. First, apply adhesive to mitered ends of cap moulding (7¼ tall) and assemble around shaft. Screw or nail joints. 18) Option 1: attach cap to soffit with construction adhesive and toenail to soffit. DO NOT ATTACH cap to column shaft if the cap is flush with soffit (allows expansion.)* 19) Option 2: Leave ¼ expansion room above cap, and pin-nail the cap to the column. Be sure pin-nails DO NOT reach the blocking inside!* 20) Caulk edges of base, cap, and nail or screw holes. 21) Clean surface of column with cleaner recommended by the paint manufacturer. Paint with 2 coats of acrylic latex paint. Please note the correct assembly of the E-Z Lock joint shown at the left. The screws or nails MUST be installed only in the edges shown (3 and 4). Installing on the other edges may result in open seams. (Pre-drill if using screws.) 1) Glue both joint edges; slide 1st joint together 2) Push 2nd joint closed 3) Nail or screw this joint first 4) Nail or screw this joint second. Notes: Panels are marked "TOP" - trim from the bottom only. Cap and base pieces are also marked as "CAP" or "BASE". Only use non-corrosive fasteners - galvanized, stainless steel, etc. Always follow glue and paint manufacturer's instructions. *Column must not be allowed to collect water, debris, etc. If the top of the column extends beyond the soffit/beam, the cap must be flashed with lead, copper, aluminum, etc. to prevent accumulation.

Endura-Classic Craftsman Tapered Install Sheet 1) Measure overall opening from floor to beam or soffit (must have structural pressure-treated post or lally column for load support.) 2) Trim shaft pieces to 2¼" shorter than opening - 2" for cap/base, ¼" for expansion (¼" if not using cap and base - each part is 1" thick.) Always trim from bottom ONLY - top is marked. 3) If you are going to use screws, pre-drill/countersink all panels. See joint diagram on next page to determine which edge to pre-drill. 4) Lay 3 panels flat and apply adhesive to center joints. (Polyurethane glue is recommended. Follow manufacturer's instructions.) 5) Assemble three panels, using E-Z lock joints. 6) If you are not using screws, finish nail three panels together. 7) If using screws, assemble three panels together using coarse thread galvanized screws (deck screws) 8) Slide ¾ base around post 9) Glue ¼ piece of base using biscuits (supplied). Center and attach to floor/pedestal with appropriate fasteners. 10) Slide assembled 3-sided column around support (on top of base) 11) Slide ¾ cap into place on top of column panels.* 12) Raise cap to beam/soffit, center, and attach. There should 1/4" between column and cap platform.

13) Apply adhesive to final panel 14) Assemble final panel to column using E-Z lock joint 15) Screw or nail final panel to secure 16) Glue ¼ cap piece and slide into place. Pin nail cap moulding to top of column.* 17) Using miter saw, cut base trim pieces to fit around bottom of column 18) Use column shaft to mark cut lines for miters (cut long and work your way shorter for best results) 19) Apply adhesive to moulding and pin-nail into place. 20) Caulk using latex caulking compound to fill any gaps & nail or screw holes. 21) Clean surface of column with cleaner recommended by the paint manufacturer. Paint with 2 coats of acrylic latex paint. Please note the correct assembly of the E-Z Lock joint shown at the left. The screws or nails MUST be installed only in the edges shown (3 and 4). Installing on the other edges will result in open seams. (Pre-drill if using screws.) 1) Glue both joint edges; slide 1st joint together. 2) Push 2nd joint closed. 3) Nail or screw this joint first. 4) Nail or screw this joint second. Notes: Panels are marked "TOP" - trim from the bottom only. Cap and base pieces are also marked as "CAP" or "BASE". Only use non-corrosive fasteners - galvanized, stainless steel, etc. Always follow glue and paint manufacturer's instructions. *Column must not be allowed to collect water, debris, etc. If the top of the column extends beyond the soffit/beam, the cap must be flashed with lead, copper, aluminum, etc. to prevent accumulation.