A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection. Steve T. Watt, Shankar V. Achanta, and Peter Selejan

Similar documents
Solutions to Common Distribution Protection Challenges

Self Healing Single Phase Looped Network AUTOMATED RECONFIGURATION FOR POWER OUTAGE MANAGEMENT. Team Members

Automated Power System Waveform Analytics for Improved Visibility, Situational Awareness, and Operational Efficiency

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

Optimize Outage Management and Improve Underground System Reliability

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

SEL-311C TRANSMISSION PROTECTION SYSTEM

Application of DFA Technology for Improved Reliability and Operations

ELECTRIC TRANSMISSION (ET) Guideline G0104

Solutions to Common Distribution Protection Challenges

Distance Protection for Distribution Feeders. Presented By: Yordan Kyosev, P.Eng. & Curtis Ruff, P.Eng.

UPGRADING SUBSTATION RELAYS TO DIGITAL RECLOSERS AND THEIR COORDINATION WITH SECTIONALIZERS

EE Lecture 14 Wed Feb 8, 2017

PLAN... RESPOND... RESTORE! Utility Automation & Information Technology... Automation Rising

DG TRANSFER CONNECTION SCHEME IN ACTIVE DISTRIBUTION NETWORKS

Operational Experience with DFA Technology at Bluebonnet Electric Cooperative and Mid-South Synergy

Intelligent and Flexible Monitor Circuits Detect & Record Load Profiles and Fault Events All Distribution Voltages All Conductor Types

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers

THE STATE OF NEW HAMPSHIRE BEFORE THE NEW HAMPSHIRE PUBLIC UTILITIES COMMISSION PREPARED TESTIMONY OF RUSSEL D. JOHNSON

Advanced Monitoring Tools to Improve Distribution System Visibility and Reduce Faults and Outages

Implementing Distribution Automation and Protection

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

Smart Grid Smarter Protection: Lessons Learned

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Transmission Availability Data System Definitions

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

Glossary of Terms Black Sky Event: Blue Sky Operations: Federal Communications Commission (FCC): Grey Sky Operations:

Notes 1: Introduction to Distribution Systems

Online Assessment of Capacitor Banks Using Circuit Health Monitoring Technology

No. SSIEC-PRC SHINSUNG. Polymer Recloser SIREC SERIES 15kV, 27kV, 38kV 400A, 630A, 800A

Transmission Availability Data Systems Frequently Asked Questions

Hamdy Faramawy Senior Application Specialist ABB Sweden

ECE 528 Understanding Power Quality

Distribution Feeder Principles

A proven distribution feeder solution with integrated protection, monitoring, and control

Protective Relaying for DER

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

Protecting Feeders With Distributed Resource Scott Elling HDR Inc HDR, all rights reserved.

Electric Power Distribution Handbook. Voltage Sags and Momentary Interruptions

PROTECTION SIGNALLING

Arrester Disconnector

SEATTLE CITY LIGHT DISTRIBUTION AUTOMATION

Power Quality Monitoring and Analytics for Transmission and Distribution Systems

200 RTH OFF ON IN OUT ALARM RESET

Use of Advanced Monitoring Technology to Detect Incipient Failure of Line Equipment

DOUBLE-ENDED FAULT LOCATORS

Commercial Deployments of Line Current Differential Protection (LCDP) Using Broadband Power Line Carrier (B-PLC) Technology

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

SEL Radio Accessories Guide

Distribution/Substation Transformer

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

COMPARATIVE STUDY OF TAP CHANGER CONTROL ALGORITHMS FOR DISTRIBUTION NETWORKS WITH HIGH PENETRATION OF RENEWABLES

SEL Radio Accessories Guide

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

Busbars and lines are important elements

IMPLEMENTATION OF CABLE HEAD REMOTE SWITCH UNIT TO INCREASE EFFICIENCY AND PRODUCTIVITY OF ONBOARD TESTING IN THE ABSENCE OF LAND INSTALLATIONS

Education & Training

Time-Domain Technology Benefits to Protection, Control, and Monitoring of Power Systems

Wires Down Improvement Program at Pacific Gas and Electric

Future. Ready. SM. Using Meters as Distribution Sensors for Capacitor Bank Monitoring. White Paper

Relay Communication Misoperations. Southwest Power Pool System Protection and Control Working Group

Transmission Protection Overview

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Retuning of FMIT #3 from 70.0 MHZ to 78.0 MHZ Charley Schwartz 10/28/02 DRAFT

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

ESB National Grid Transmission Planning Criteria

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Distance Relay Response to Transformer Energization: Problems and Solutions

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

IMPLEMENTATION OF ADVANCED DISTRIBUTION AUTOMATION IN U.S.A. UTILITIES

WIRELESS THREE PHASE LINE FAULT MONITORING

ECE 528 Understanding Power Quality

In order to minimise distribution (11 and 22 kv) feeder breaker

Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers

QUESTIONNAIRE ON FAULT LOCATION SYSTEMS

S&C Vista Underground Distribution Switchgear Outdoor Distribution

A TECHNIQUE TO UTILIZE SMART METER LOAD INFORMATION FOR ADAPTING OVERCURRENT PROTECTION FOR RADIAL DISTRIBUTION SYSTEMS WITH DISTRIBUTED GENERATIONS

Fixed Series Compensation

Increased Reliability of EHV Systems through Station Switchable Spare Transformer and Shunt Reactor Design and Operation

Time-current Coordination

Lightning test in lab. Symmetrical fault and protection. Olof Samuelsson

CP CU1. Coupling unit for line and ground testing

Circuit Reliability Review

Earthing of Electrical Devices and Safety

System Protection and Control Seminar

Switch-on-to-Fault Schemes in the Context of Line Relay Loadability

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

EE 741 Spring Electric Power Distribution Systems An Overview

EE 741. Primary & Secondary Distribution Systems

APPLICATION OF MULTI-FREQUENCY ADMITTANCE-BASED FAULT PASSAGE INDICATION IN PRACTICAL COMPENSATED MV-NETWORK

VTSC100. Transfer Switch Controller

Suggested reading for this discussion includes the following SEL technical papers:

2 Grounding of power supply system neutral

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

REF 610 Feeder Protection Relay. Technical Reference Manual

Transcription:

A New Use for Fault Indicators SEL Revolutionizes Distribution System Protection Steve T. Watt, Shankar V. Achanta, and Peter Selejan

2017 by Schweitzer Engineering Laboratories, Inc. All rights reserved. All brand or product names appearing in this document are the trademark or registered trademark of their respective holders. No SEL trademarks may be used without written permission. SEL products appearing in this document may be covered by US and Foreign patents. 20170606

Introduction Fault indicators have been used for several decades to help locate faults, but the idea of using them to improve protection is new. To enhance protection, wireless sensors must operate faster than ever before and communicate directly with recloser controls and feeder relays. To accomplish this, SEL sped up fault sensing and communication with Fault Transmitters and tightly integrated the Fault Receiver with protective relays. Distribution system protection can be improved by using the / Fault Transmitter and Receiver System in medium-voltage applications such as: Hybrid fuse-saving and fuse-blowing protection schemes. Precise protection selectivity of underground-to-overheard transitions. Simplifying or eliminating coordination with downstream protection devices. Enhanced protection positively impacts reliability metrics, equipment life, system stability, and safety. / Fault Transmitter and Receiver System The / System consists of high-speed fault transmitters () and a wireless fault receiver (), as shown in Figure 1. It is designed to be paired with a recloser control or feeder relay. Figure 1 Fault Transmitter and Fault Receiver The contains a current transformer and clamps onto an overhead feeder, detects overcurrent conditions, and powers itself without batteries by harvesting energy from the line. When adjustable trip thresholds are exceeded, a radio transmitter in the sends highspeed wireless signals to an Receiver. The Transmitter also sends the radio link status to the Receiver every 15 seconds. The is capable of simultaneously receiving fault information from as many as 12 Transmitters. The communicates to a protective relay using high-speed MIRRORED BITS communications protocol. The wireless signaling between Transmitters and the takes place on the 900 MHz unlicensed band and has a wireless link range of up to 4 miles. The / System comes with a configurable network ID that enables the operation of multiple / Systems in close proximity. 3

The protective relay or recloser control supervises the fault information from the / System, and it accelerates the trip decision if it also detects a fault based on the programming of its protective elements, making the protection system fast and secure. The protective relay or recloser control is designed to work reliably even if radio communications to the are temporarily lost to ensure dependability. Add an / System to Mix Protection Schemes and Optimize SAIDI and MAIFI For a given distribution feeder segment, a recloser control can be optimized for reducing outages (System Average Interruption Duration Index [SAIDI]) or reducing momentary faults (Momentary Average Interruption Frequency Index [MAIFI]). Adding an / System to a recloser control allows protection schemes to be mixed to create a hybrid scheme that balances SAIDI and MAIFI. Mixed Protection Scheme 1: Fuse Blowing Primary, Fuse Saving Secondary Fuse-blowing schemes are commonly used in urban areas where feeders have numerous taps. In this type of scheme, a fault on a tap causes a fuse at the beginning of the tap to open (i.e., blow). The outage is confined to the tap, and the recloser control avoids reclosing attempts on the main line, which delivers good MAIFI metrics. The downside of this approach is that temporary faults can cause a fuse to blow and create a permanent outage for the tap, resulting in poor SAIDI metrics. To optimize SAIDI and MAIFI metrics, a hybrid fuse-blowing/fuse-saving scheme can be employed using the / System. In Figure 2, all of the taps are fused. If a fault occurs on a tap, the recloser control will allow the fuse to blow. In Figure 2, the top-right tap is an exception. This tap may, for example, be in a wooded area with numerous temporary faults that do not require the fuse to blow. Alternately, it could be a tap with an important load (such as medical life-support equipment) or a tap where fuse replacement is difficult because of its remote location. R1 R2 Figure 2 Fuse Blowing as the Primary Protection Scheme With a Fuse-Saving Scheme Employed on the Top-Right Tap For the top-right tap, an alternate protection scheme is desirable. By using the / System and some SELOGIC programming, the recloser control will employ a fuse-saving approach when it senses a fault on this tap, allowing reclosing to clear the fault before the fuse melts. 4

Mixed Protection Scheme 2: Fuse Saving Primary, Fuse Blowing Secondary When fuse saving is the primary protection scheme, maximum effort is spent to clear all temporary faults on the feeder. This approach is commonly used in rural areas, large coverage territories, rugged terrain, areas with severe weather, and when personnel availability is constrained. The goal is to only take outages for permanent faults. Fuse saving improves SAIDI metrics and operations and maintenance costs. The downside of this scheme is that repeated reclosing results in poor MAIFI metrics. In Figure 3, the / System allows the substation feeder relay to treat the top-left tap differently. This tap is easy for crews to access, so it makes more sense to use a fuseblowing scheme to avoid blinking the entire feeder for a temporary fault. Feeder Relay R1 R2 Figure 3 Fuse Saving as the Primary Protection Scheme With a Fuse-Blowing Scheme Employed on the Top-Left Tap As shown in both examples, the addition of the / System allows a hybrid protection scheme to balance MAIFI and SAIDI based on the characteristics of specific taps. Improve Protection at Underground-to-Overhead Feeder Transitions Feeders with underground-to-overhead transitions present utilities with a protection challenge. Underground faults are typically permanent and overhead faults are usually temporary. Mixing underground protection schemes with the / System can fine-tune protection at feeder underground-to-overhead transitions. In Figure 4, to reduce congestion in the substation yard, a feeder leaves a substation underground and transitions to an overhead riser pole after some distance. Feeder Relay Underground Egress Cable Overhead Distribution Feeder Figure 4 Underground-to-Overhead Feeder Transition Outside Substation Utilities are often unwilling to reclose on faults near an underground-to-overhead transition because they do not want to reclose on underground faults. Underground faults are typically permanent, and reclosing on permanent faults stresses cables and connectors. Therefore, it is important to precisely know the fault location to choose the best protection scheme. 5

Transmitters can be placed at the beginning of the overhead span. If an detects a fault, it sends a message to the Receiver connected to the feeder relay. The relay can change its protection scheme from blocking to allow reclosing to clear the temporary overhead fault. This fine-tuned selectivity approach reduces outages and improves SAIDI metrics. The / System also provides benefits when transitions are overhead-tounderground, as shown in Figure 5. R1 Overhead Distribution Feeder Underground Feeder Figure 5 Overhead-to-Underground Transitions in a Distribution System Distribution feeders can transition to underground to serve loads in areas where developers have installed underground utilities. Utilities with such feeders that choose to reclose on all faults risk reclosing on underground faults. Using sensors at the transition point allows the recloser control to optimize its operation by reclosing for overhead segments to clear most overhead faults and blocking reclosing for underground faults, making the power system more selective. Bypass Coordination Delays To clear faults from lines and apparatus along a distribution circuit, distribution protection engineers set up a preset sequence of operations in overcurrent protection devices by specifying certain time-current characteristics and settings. This is known as coordination. When two protective devices installed in series have characteristics that provide a specific operating sequence during fault conditions, they are said to be coordinated. The device that is upstream from the fault is set to operate first. In cases when this device fails to operate, the next upstream device in line operates, providing backup protection to clear faults. Radial Feeders Recloser Control R1 and fuses on the taps protect the radial feeder shown in Figure 6. R1 has limited visibility as to where a downstream fault is. In a fuse-blowing scheme, R1 waits for coordination with the Line L1 and L2 fuse curves. If the fault is on Main Line M1 or L3, the 100 200 ms wait for the L1 and L2 curves is unnecessary because M1 and L3 are not fused. R1 L3 L1 M1 L2 Figure 6 Feeder With Fuses on Some Taps and a Fault 6

In Figure 7, L3 and M1 after L1 have Transmitters communicating with an Receiver connected to R1. The Transmitter instantly detects the fault on M1 and sends this information to the Receiver. Because R1 knows that M1 is not protected by a fuse, R1 can operate without the fuse coordination delay in less than 50 ms. L3 L1 R1 M1 L2 Figure 7 Feeder With / System Distribution Loops The / System can also improve coordination in distribution loops. In a typical loop configuration, two distribution circuits are separated by a normally-open (N.O.) point, as shown in Figure 8. R1 R2 R3 N.O. S2 R5 R4 Figure 8 Distribution Loop With a Permanent Fault Because the permanent fault is between R1 and R2, the goal is to quickly isolate the fault between these reclosers and restore power to segment R2-R3. This can be done without communication; however, isolating the permanent fault and restoring power to the nonfaulted segment takes about 1 minute. With communication to the recloser controls, the process is accelerated to 100 200 ms. Figure 9 shows the setup for a looped fault detection and isolation scheme with two / Systems. Each recloser control is connected to an. The three Receivers in the top network (blue) are set up with the same network ID as the nine Transmitters attached to the feeder conductors near, R1, and R2. The three Receivers in the bottom network (gold) are set up with the same network ID as the nine Transmitters attached to the feeder conductors near S2, R5, and R4. At R3, the normally-open point, each Receiver receives communication from nine Transmitters. 7

and Network 3 x 3 x 3 x R1 R2 R3 N.O. 3 x 3 x 3 x S2 R5 R4 and Network Figure 9 Distribution Loop With Two / Systems The fault between R1 and R2 is detected by the Transmitters located near R1 but not by the Transmitters located near R2. The Transmitters located near R1 send a high-speed wireless signal to all three Receivers in the top network within 6 ms of detecting the fault. R2 opens, isolating the faulted segment, and R3 closes to restore the R2-R3 segment. Adding the / communication capabilities to the loop significantly reduces the time to isolate a fault and restore the system. With a cost under $7,000 for the two / systems, the / System is a low-cost approach to achieving highspeed fault detection and isolation in a distribution loop. The Benefits of Faster Protection Reducing the duration of faults not only improves reliability metrics, but also has the following additional benefits: Extended equipment life. Clearing faults before they can fully develop reduces stress on infrastructure. Improved system stability. Shorter fault-clearing times reduce voltage fluctuations. Increased safety. Faster fault clearing reduces the chance of fires, electrocution, and other safety hazards. Figure 10 shows the life expectancy curves of a substation transformer with frequent and infrequent fault durations. As shown in Figure 10, faults have a cumulative effect on transformer life. Therefore, reducing exposure to faults extends transformer life. During fault conditions, voltages can fluctuate. Phases adjacent to the faulted phase can experience voltage sag. Shortening the duration of faults lessens the impact of voltage deviations, which is especially important for devices like consumer electronics that have tight tolerances for power quality. Conductors coming into contact with trees or other equipment during faults can start catastrophic fires. The longer the fault stays on the line, the longer the shower of sparks continues. Broken or fallen conductors can also be an electrocution hazard. Isolating faults faster can reduce the chances of fires and other safety hazards. 8

Initial Stress Withstand Capability Result of Overstress Events Premature End of Life Stress End of Life Stress Encountered Time Figure 10 Transformer Lifetime Prediction [1] Narrow Down Fault Locations The fault-detection information from the / System can be retrieved from the recloser control, or it can be sent by the recloser control back to a SCADA or outage management system. This provides line crews with more specific location and phase information for a fault, reducing patrol time. Figure 11 and Figure 12 show the difference in the amount of line to patrol without and with the / System, respectively. Note that the patrol crew first inspects all fuses and only inspects the rest of the line if a fuse is blown. R1 R2 Area to Patrol Figure 11 Area to Patrol Without the / System Area to Patrol R1 R2 Figure 12 Area to Patrol With the / System 9

Improved fault location information allows personnel to reduce patrol times and drive right to the faulted tap or segment, improving Customer Average Interruption Duration Index (CAIDI) metrics. The ability to identify the faulted segment ahead of time is especially helpful when feeder lines are numerous, difficult to get to or not close to major roads, or when crews face poor weather conditions. Conclusion The key benefits for distribution systems of combining / Systems with advanced recloser controls and feeder relays include the following: Improved SAIDI, CAIDI, and MAIFI metrics from mixing fuse-saving and fuse-blowing schemes. Selective protection for underground-to-overhead transitions, which reduces permanent outages and the risk of reclosing on underground faults. Faster protection on radial feeders by eliminating unnecessary wait times for coordination. Faster fault isolation and restoration of distribution loops. Increased equipment life. Improved system stability and power quality. Improved safety. Reduced patrol time for fault location. Advanced recloser controls and feeder relays have driven improvements in reliability metrics by using more precise fault-detection methods, clearing a greater number of temporary faults, and enabling effective fault isolation and restoration schemes. By adding Fault Transmitters and Fault Receivers to existing protection systems, utilities can improve reliability further and realize additional distribution system benefits. Reference [1] C. Osorio and N. Sawant, EE292K: Intelligent Energy Projects, Stanford University. Available at: http://web.stanford.edu/class/ee292k/proposals/christiannandan.pdf. Biographies Steve T. Watt received his B.S. in mechanical engineering from Virginia Polytechnic Institute and State University. He worked in the information technology industry for over 20 years at Hewlett Packard before joining Schweitzer Engineering Laboratories, Inc. (SEL) in 2012. Steve is currently the market manager for precise timing and wireless networking products at SEL. Shankar V. Achanta received his M.S. in electrical engineering from Arizona State University in 2002. He joined Schweitzer Engineering Laboratories, Inc. (SEL) in 2002 as a hardware engineer, developing electronics for communications devices, data acquisition circuits, and switch-mode power supplies. Shankar currently holds nine SEL patents, and he is an inventor on several patents that are pending in the field of precise timing and wireless communications. He currently holds the position of engineering director for the precise time, fault indicators, and sensors division at SEL. 10

Peter Selejan received his B.S. in electrical engineering from University of Florida in 1992. He worked at ABB for 22 years as an R&D engineer, project manager, and recloser product specialist. During this time, he was awarded two patents in the area of phase selection and coauthored Technologies of the Self Healing Grid, which was published at CIRED 2013. In 2016, he joined Schweitzer Engineering Laboratories Inc. where he works as an application engineer in protection. 11

Schweitzer Engineering Laboratories, Inc. Tel: +1.509.332.1890 Email: info@selinc.com Web: www.selinc.com *LWP0022-01* 12