BNC-2121 Connector Accessory for 660X Devices

Similar documents
FP-DO-400 and cfp-do-400

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

FP-CTR-502 and cfp-ctr-502

FP-CTR-500 and cfp-ctr-500

NI 6624 Calibration Procedure

NI 6013/6014 Family Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

SCC-DI01 Isolated Digital Input Module

Getting Started with the LabVIEW DSP Module

TB-2705 PXI TERMINAL BLOCK FOR ESERIES

SCXI High-Voltage Terminal Block

NI 6143 Specifications

SCXI High-Voltage Terminal Block

NI PXI-2532 Specifications

FP-RTD-122 and cfp-rtd-122

NI DAQPad -6020E Family Specifications

NI 6023E/6024E/6025E Family Specifications

NI sbrio-9632/9642 Verification Procedure

NI Channel, TTL Digital Input/Output Module

SCC-ACC01 Accelerometer Input Module

FP-SG-140 AND CFP-SG-140

NI Channel, Universal Digital Input Module

NI Channel SPST Electromechanical Relay Module

NI 6731/6733 Specifications

OPERATING INSTRUCTIONS NI Port DeviceNet Module

SCC-FV01 Frequency Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

FP-RTD-122 AND CFP-RTD-122. Features. FieldPoint Operating Instructions. Eight-Channel Three-Wire RTD and Resistance Input Modules

Table 2. Differences Between the USB-6008 and USB Feature USB-6008 USB bits differential, 13 bits single-ended Maximum AI Sample Rate,

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

NI 6040E Family Specifications

FP-DO-401 and cfp-do-401

FP-DO-403 and cfp-do-403

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

30 A AC/DC Current Probe TCP0030A Datasheet

NI 6230 Specifications

NI PXI/PCI-5411/5431 Specifications

NI SCXI Specifications

Specifications for the NI PXI/PCI-6552/6551

NI PXI/PCI-5411/5431 Specifications

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI-4461 Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

INSTALLATION GUIDE BNC-2120 Connector Accessory for E/M/S Series Devices. Contents

NI 951x C Series Modules Object Dictionary

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Eight-Channel Thermocouple Input Module

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

SCXI HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK

SCXI MHz Quad 8x1 50 Ω Multiplexer

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, ±10 V, 16-Bit Simultaneous Analog Input Module. ni.com/manuals

TBX CHANNEL ISOTHERMAL TERMINAL BLOCKINSTALLATION GUIDE

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

NI PXI/PXIe-2540 Specifications

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

NI PXI-2557 Specifications

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

NI PXI-2555 Specifications

AC Current Probes CT1 CT2 CT6 Data Sheet

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

Analog Characteristics

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

NI 6238/6239 Specifications

Specifications. PCI Bus. Analog Input Input Characteristics

NI PXI/PXIe-2529 Specifications

TBX-1326 HIGH-VOLTAGE TERMINAL BLOCK

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

NI PXI-2530 Specifications

Arbitrary/Function Generator AFG1000 Series Datasheet

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

Arbitrary Function Generator AFG1022 Datasheet

AC/DC Current Measurement Systems

NI PXIe-5630 Specifications

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

20X Low Capacitance Probe P6158 Datasheet

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

High-impedance Buffer Amplifier System

AC/DC Current Probe TCP0150 Datasheet

High-voltage Differential Probes

NI PXI/PXIe-2527 Specifications

Debugging SENT Automotive Buses with an Oscilloscope APPLICATION NOTE

AC/DC Current Measurement Systems

1.5 GHz Active Probe TAP1500 Datasheet

PXIe Contents. Required Software CALIBRATION PROCEDURE

Arbitrary Function Generator AFG1000 Series Datasheet

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Differential Probes P6248 P6247 P6246 Datasheet

Agilent 8762F Coaxial Switch 75 ohm

PRODUCT DATA. Sound Intensity Calibrator Type 4297

DEVICE SPECIFICATIONS NI PXIe Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Transcription:

USER GUIDE BNC-2121 Connector Accessory for 660X Devices The BNC-2121 connector accessory is a terminal block that connects signals to a 660X counter device and can be used to test features of a660x device. Use this guide to install and connect signals to a BNC-2121 connector accessory for testing or for performing counter applications. For specific information about using a 660X device, refer to the 660X User Manual. What You Need to Get Started You need the following items to install and use the BNC-2121 connector accessory. BNC-2121 connector accessory BNC-2121 Connector Accessory for 660X Devices User Guide 660X device 660X User Manual 68-position cable, such as the SH68-68-D1 or R6868 BNC cables Wire no larger than 24 AWG Wire strippers

Connecting the BNC-2121 to a 660X Device You can use a BNC-2121 with any installed 660X device. Connect one end of a 68-position cable to a 660X device and the other end to the I/O connector on the BNC-2121, as shown in Figure 1. Figure 1. Connecting a BNC-2121 to a 660X Device Note If the power LED indicator does not light up, check the cable connections to make sure the cable is connected securely. Connecting Signals to the BNC-2121 Connect signals using the spring terminals or BNC connectors shown in Figure 2. For pinout diagrams and more specific information about connecting signals, refer to the 660X User Manual. BNC-2121 Connector Accessory for 660X Devices 2 ni.com

1 2! Drive only one signal per PFI line Electrostatic using either a BNC, a spring Sensitive terminal or the 660X device. Connectors PFI LINES 0-39 PFI PFI 0 P0.0 P0.1 1 2 P0.2 P0.3 3 PWR BNC-2121 DIGITAL I/O INDICATORS P0.0 P0.1 11 12 4 P0.4 6 P0.6 8 OUT7 P0.5 5 P0.7 7 UP/DN7 9 P0.2 P0.4 P0.3 P0.5 13 10 GATE7 SRC7 11 P0.6 P0.7 12 OUT6 14 GATE6 16 OUT5 UP/DN6 13 SRC6 15 UP/DN5 17 PFI LINES 32-39 18 GATE5 SRC5 19 OUT1 PFI 32 UP/DN1 PFI 33 PFI 20 OUT4 UP/DN4 PFI 21 22 GATE4 SRC4 23 24 OUT3 26 GATE3 UP/DN3 25 SRC3 27 GATE1 PFI 34! SRC1 PFI 35 14 28 OUT2 UP/DN2 29 30 GATE2 SRC2 31 32 OUT1 34 GATE1 UP/DN1 33 SRC1 35 OUT0 PFI 36 UP/DN0 PFI 37 36 OUT0 UP/DN0 37 38 GATE0 SRC0 39 RESERVE1 RESERVE2 GATE0 PFI 38 SRC0 PFI 39 USER DEFINED FUNCTIONS 3 4 5 6 7 ENCODER A ENCODER B TRIGGER +5V USER 1 USER 2 USER 3 USER 4 USER 5 USER 6 USER 1 USER 2 USER 3 USER 4 15 16 8 Quadrature Encoder 24 Pulses/rev (A,B) 9 10 Digital Trigger (TRIGGER) OFF Filtering ON USER 5 USER 6 14 khz-1 MHz 150 Hz-20 khz 10 Hz-200 Hz LO HI Frequency Frequency ( ) ( ) Selection Adjust 17 18 19 1 Warning Label 2 PFI Line Spring Terminal 3 Quadrature Encoder Output Spring Terminals 4 Digital Trigger Output Spring Terminal 5 Frequency Output Spring Terminal ( ) 6 +5 V Output Spring Terminal 7 Terminal 8 Quadrature Encoder Knob 9 Digital Trigger Button 10 Digital Trigger Filtering Switch 11 68-Position I/O Connector 12 Power LED Indicator 13 Digital Line LED State Indicator 14 BNC Connectors for Counters 0 and 1 15 User-Defined BNC Connector 16 Spring Terminals for User-Defined BNC Connectors 17 Frequency Selection Switch 18 Frequency Adjust Knob 19 Digital Trigger Line LED State Indicator Figure 2. BNC-2121 Front Panel National Instruments Corporation 3 BNC-2121 Connector Accessory for 660X Devices

Overview of Connecting to the BNC-2121 The BNC-2121 has two main areas of connectivity: the PFI lines and the user-defined functions. The PFI lines include bidirectional spring terminals, PFI <0..39>, and bidirectional BNC connectors, PFI <32..39>. Both connection types provide access to the respective PFI lines on the 660X device. The digital I/O indicators reflect the state of the dedicated digital I/O P.<0..7> spring terminals. The user-defined function connections include the following: Six output spring terminals Encoder A, Encoder B, Trigger, Square Wave ( ), +5 V, and Controls for the outputs listed above Quadrature Encoder, Digital Trigger, Frequency Selection, and Frequency Adjust Table 1 lists the controls and the outputs associated with them. Table 1. User-Defined Function Controls and the Corresponding Outputs Controls Quadrature Encoder Knob Quadrature Encoder Knob Digital Trigger Button Frequency Selection Frequency Adjust Spring Terminal Outputs Encoder A Encoder B Trigger Six bidirectional, user-defined spring terminals USER <1..6> Six user-defined BNC connectors USER <1..6> Note The user-defined spring terminals are internally mapped one-to-one to corresponding BNC connectors. For example, the USER 1 spring terminal is internally wired to the USER 1 BNC connector. When you want BNC connections for counters other than 0 or 1, use the user-defined connections. BNC-2121 Connector Accessory for 660X Devices 4 ni.com

Connecting to the Spring Terminals Use the BNC-2121 connector accessory to access the PFI lines on a 660X device. To make the connection, complete the following steps. 1. Using wire strippers, strip the wire insulation no more than 7 mm. 2. Connect a wire to a spring terminal on the BNC-2121 by depressing the orange tab and inserting the stripped end of the wire fully into the terminal. Tip For the best performance, use twisted-pair wire. Connect one wire of the wire pair from the signal on the peripheral device and the other end of the same twisted wire to the signal on the BNC-2121. Connect the other wire of the wire pair to the ground of the peripheral device and the other end to the ground () spring terminal closest to the signal. Caution Make sure that no bare wire extends past the spring terminal. Exposed wire increases the risk of a short circuit or a failure. Connecting to the BNC Connectors 3. If you need to ground a signal, a ground () spring terminal is available between every two PFI lines. For details about grounding a signal, refer to the 660X User Manual. The user-defined functions area of the BNC-2121 has six user-defined spring terminals, USER <1..6>, and six corresponding BNC connectors, USER <1..6>. Use these spring terminals for either input or output. For example, if you want to connect a BNC cable to GATE of a counter other than Counter 0 or 1, connect a wire from the GATE spring terminal on the 660X device to a user-defined spring terminal (USER 1) on the BNC-2121, and the signal is available through the corresponding BNC connector (USER 1). The six other spring terminals (ENCODER A, ENCODER B, TRIGGER,, +5 V, and ) are used as signal outputs only. Follow steps 1 and 2 in this section to connect the output wires to the appropriate spring terminals. Use the corresponding controls for each spring terminal, given in Table 1, to regulate a signal. Use the eight BNC connectors to access PFI <32..39> on a 660X device. Each line corresponds to SOURCE, GATE, OUT, and UP/DOWN of counter 0 or 1. National Instruments Corporation 5 BNC-2121 Connector Accessory for 660X Devices

To make the connection, complete the following steps. 1. Insert one end of the BNC cable in one of the PFI <32..39> BNC connectors. 2. Connect the other end of the BNC cable to the output device. In addition to the BNC connectors associated with the PFI lines of the 660X device, the BNC-2121 has six user-defined BNC connectors, USER <1..6>, that are associated with six corresponding user-defined spring terminals USER <1..6>. You can use these BNC connectors for either input or output. Testing User-Defined Functions Producing a +5 V Pulse Measuring Position You can use the BNC-2121 to test the following features on the 660X device. Use the digital trigger to test an application that counts or measures pulses. Press the Digital Trigger button to produce a +5 V pulse for as long as the button is pressed, causing the LED to light up. When you release the button, the trigger line goes low. You can access the digital trigger by connecting a wire to the Trigger spring terminal. The digital trigger also can simulate a channel Z pulse for quadrature encoder functions. The lowpass filter on the BNC-2121 is designed to remove glitches on the trigger output. If you want to use unconditional trigger output to test the debouncing filter on a 660X device, flip the Filtering switch to the OFF position, connect the trigger output to a PFI line, and programmatically enable the debouncing filter on the 660X device. For all other applications, flip the Filtering switch to the ON position. The BNC-2121 can produce 24 pulses per encoder revolution. You can test this feature using the following programs. C interface TIOquadEncoderPosMeasure.c located in Program Files/National Instruments/Measurement Studio/CVI/Samples/DAQ/Ctr LabVIEW Measure Position VI located in Program Files/ National Instruments/LabVIEW/Examples/DAQ/Counter/ NI-TIO.llb BNC-2121 Connector Accessory for 660X Devices 6 ni.com

To measure position using counter 0 of a 660X device, make the following connections. 1. Connect a wire from channel A to SOURCE of counter 0 (default PFI 39). 2. Connect a wire from channel B to UP/DOWN of counter 0 (default PFI 37). Note If you want to simulate a Z channel, connect a wire from the Trigger spring terminal to GATE of counter 0 (default PFI 38). Creating a Square Wave Viewing the State of the DIO Lines The BNC-2121 has a function generator that produces TTL-compatible square waveforms. To create a square wave, complete the following steps. 1. Access the square wave output by connecting signals to the spring terminal. 2. Use the Frequency Selection switch to select a frequency range of 10 Hz 200 Hz, 150 Hz 20 khz, or 14 khz 1 MHz. 3. Adjust the frequency within the range you selected by turning the Frequency Adjust knob. The eight Digital I/O indicators indicate the state of PFI <0..7> on a 660X device. When the LED is lit, the channel is in the high state. When the LED is off, the channel is in the low state. Using the BNC-2121 to Perform Counter Applications This section explains how to connect signals to the BNC-2121 to test, demonstrate, and perform counter applications with a 660X device. To find the correct application to perform, refer to the 660X User Manual. Counter program examples mentioned in this section are in the following locations. NI-DAQ Measurement Studio\CVI\Samples\DAQ\Ctr LabVIEW Program Files\National Instruments\ LabVIEW\Examples\DAQ\Counter\NI.TIO.llb National Instruments Corporation 7 BNC-2121 Connector Accessory for 660X Devices

Simple Event Counting Gated Event Counting Single Period Measurement Single Pulse-Width Measurement To perform simple event counting, connect a wire from the spring terminal to The 660X device counts the number of pulses that occur on SOURCE. Alternatively, you can connect a wire from the Trigger spring terminal to provide pulses on SOURCE. To perform gated event counting, complete the following steps. 1. Connect a wire from the spring terminal to SOURCE of the 2. Connect a wire from the Trigger spring terminal to GATE of the 3. Press and hold the Digital Trigger button to drive GATE into a high state. The counter counts the pulses on SOURCE as long as GATE is high. 4. Release the Digital Trigger button to drive GATE into a low state. The counting halts and retains its value until you press the Digital Trigger button again and counting continues. To take a single period measurement, complete the following steps. 2. Connect a wire from the spring terminal to GATE of the selected counter. The counter counts the rising edges on SOURCE between two active GATE edges. The period is this count multiplied by the period of SOURCE. To take a single pulse-width measurement, complete the following steps. 2. Connect a wire from the Trigger spring terminal to GATE of the 3. Press the Digital Trigger button to drive GATE into a high state. The counter counts the rising edges on SOURCE while GATE is active. 4. Release the Digital Trigger button to drive GATE into a low state. The counter value is latched for a software read. BNC-2121 Connector Accessory for 660X Devices 8 ni.com

Two-Signal Edge-Separation Measurement To take a two-signal edge-separation measurement, complete the following steps. 1. Connect a wire from the spring terminal to UP/DOWN of the 2. In the C interface or in LabVIEW, select an internal timebase as As soon as UP/DOWN goes active, the counter counts the edges on SOURCE. 3. Connect a wire from the Trigger spring terminal to GATE of the 4. Press the Digital Trigger button to drive GATE into an active state. As soon as GATE goes active, the counter value is latched for a software read. Note UP/DOWN and AUX_LINE share the same PFI line on all counters. Single Pulse Generation Single-Triggered Pulse Generation To generate a single pulse, complete the following steps. 2. Specify the pulse delay and pulse width in the C interface or LabVIEW. 3. To see the signal, connect an oscilloscope or analog input device to OUT of the To generate a single-triggered pulse, complete the following steps. 2. Specify the pulse delay and pulse width in the C interface or LabVIEW. 3. Connect a wire from the Trigger spring terminal to GATE of the 4. Press the Digital Trigger button to generate a single pulse. One pulse is generated on OUT of the counter when the trigger is received. 5. To see the signal, connect an oscilloscope or analog input device to OUT of the National Instruments Corporation 9 BNC-2121 Connector Accessory for 660X Devices

Retriggerable Single Pulse Generation To generate a retriggerable single pulse, complete the following steps. 2. Specify the pulse delay and pulse width in the C interface or LabVIEW. 3. Connect a wire from the Trigger spring terminal to GATE of the 4. Press the Digital Trigger button to generate a pulse. Any time you want an additional pulse, press the Digital Trigger button to generate a pulse on OUT of the counter. Note A pulse is generated on every active GATE edge. Continuous Pulse-Train Generation Frequency Shift-Keying 5. To see the signal, connect an oscilloscope or analog input device to OUT of the To generate a continuous pulse-train, complete the following steps. 2. In the C interface or in LabVIEW, specify the frequency and duty cycle of the pulse train. 3. To see the signal, connect an oscilloscope or analog input device to OUT of the To perform frequency shift-keying, complete the following steps. 2. Connect a wire from the Trigger spring terminal to GATE of the 3. Press the Digital Trigger button to drive GATE into a high state. 4. Release the Digital Trigger button to drive GATE into a low state. 5. To see the signal, connect an oscilloscope or analog input device to OUT of the BNC-2121 Connector Accessory for 660X Devices 10 ni.com

Buffered Event Counting Buffered Period Measurement To perform buffered event counting, complete the following steps. 2. Connect a wire from the spring terminal to GATE of the selected counter. Each time GATE goes high, the value of the counter is latched to a buffer. To perform buffered period measurement, complete the following steps. 2. Connect a wire from the spring terminal to GATE of the selected counter. Note To ensure valid measurement data, discard the first value because the counter may be armed between active edges. The counter is latched at each active GATE edge (rising or falling) and the counter resets to zero. Buffered Semi-Period Measurement To perform buffered semi-period measurement, complete the following steps. 2. Connect a wire from the spring terminal to GATE of the selected counter. Each time GATE goes high, the value of the counter is latched to a buffer. Because buffered semi-period measurement measures each phase of the pulse train, you can detect changes in duty cycle. Note To ensure valid measurement data, discard the first value because the counter may be armed between active edges. The counter is latched at each active GATE edge (rising or falling) and the counter resets to zero. National Instruments Corporation 11 BNC-2121 Connector Accessory for 660X Devices

Buffered Pulse-Width Measurement To perform buffered pulse-width measurement, complete the following steps. 2. Connect a wire from the spring terminal to GATE of the selected counter. Each time GATE goes high, the value of the counter is latched to a buffer. Note For buffered pulse-width measurement, the counter value obtained between the rising and falling edges of GATE is latched at the completion of each pulse-width interval of GATE. Buffered Two-Signal Edge-Separation Measurement Buffered Periodic Event Counting To perform a buffered two-signal edge-separation measurement, complete the following steps. 2. Connect a wire from the spring terminal to UP/DOWN of the 3. Connect a wire from the Trigger spring terminal to GATE of the The counter counts the rising edges on SOURCE between the active edge of UP/DOWN and the active edge of GATE. The counter value latches at each active edge of GATE. 4. Press the Digital Trigger button to drive GATE into a high state. Press the Digital Trigger button several times to obtain multiple GATE edges. To perform buffered periodic event counting, complete the following steps. 1. Connect a wire from the spring terminal to SOURCE of the 2. Connect a wire from the Trigger spring terminal to GATE of the The counter increments on each active SOURCE edge and latches at each active GATE edge. BNC-2121 Connector Accessory for 660X Devices 12 ni.com

Miscellaneous Functions Use these functions with any of the counter applications described in this document. Measuring Frequency To measure a frequency using counter pair 0 and 1, complete the following steps. 1. In the C interface or in LabVIEW, select GATE as the output of the other counter. This selection allows OUT of counter 1 to be the GATE signal for counter 0. 2. Connect a wire from the spring terminal to SOURCE of counter 0, which is PFI 39. The counter counts the number of edges received during the interval defined by OUT of counter 1. The frequency measured is the number of counts divided by the duration of GATE in seconds. Another counter pair also can be similarly used. Simultaneously Starting Counters You can configure two or more counters to arm from the same start trigger using a software or hardware command. To simultaneously arm two or more counters to perform single pulse generation, complete the following steps. 1. Configure two or more counters to generate a pulse after receiving a start trigger. In software, select a PFI line, such as PFI 0, to receive the start trigger. 2. To see the pulse on the outputs, connect an oscilloscope or analog input device to OUT of the selected counters. 3. Connect a wire from the Trigger spring terminal to the selected PFI line and use it to produce the start trigger. Note You can use this method for any counter application. National Instruments Corporation 13 BNC-2121 Connector Accessory for 660X Devices

Specifications This section lists the specifications of the BNC-2121. These specifications are typical at 25 C unless otherwise noted. PFI <0..39> Spring terminals...40 positions, wire no larger than 24 AWG BNC connectors...8 for PFI <32..39> User-Defined Field connections...6 BNC connectors Quadrature Encoder Spring terminals...6 positions, wire no larger than 24 AWG Spring terminals...2 Channel A/Channel B output channels...channel A leads Channel B when the encoder knob is turned 90 clockwise Pulse width...1 µs Resolution...24 pulses per revolution Digital Trigger Number of signals...1 (TRG signal for triggering) Function Generator Spring terminals...1 position Lowpass filter...f 0 = 15 Hz Square wave...ttl compatible Frequency range...10 Hz 1 MHz; ±10% deviation over entire frequency range Rise time...250 ns BNC-2121 Connector Accessory for 660X Devices 14 ni.com

Fall time... 50 ns Spring terminal... 1 position Output voltage... Refer to Figure 3 Volts 6 5 4 3 2 1 0 1 MHz 10 khz 5 khz 2 khz 1 khz 680 Hz Hz Square Wave (V peak-to-peak ) Digital Input/Output Power Requirement Figure 3. Typical Maximum Voltages versus Load Impedances LED state indicators... 8 (1 per digital line on PFI <0..7>) 5 VDC (±5%)... 200 ma, sourced from 660X device, which provides 1 A Power available at 5 V spring terminal (±5%)... 600 ma, sourced from 660X device, which provides 1 A Physical Dimensions... 27.2 by 11.2 by 5.21 cm (10.69 by 4.41 by 2.05 in.) I/O connector... 68-pin male SCSI-II type BNC connectors... 14 Spring terminal plugs... 72 National Instruments Corporation 15 BNC-2121 Connector Accessory for 660X Devices

Environment Operating temperature...0 to 50 C Storage temperature... 20 to 70 C Relative humidity...10 to 90% noncondensing Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 3111-1, UL 61010B-1 CAN/CSA C22.2 No. 1010.1 Note For UL and other safety certifications, refer to the product label or to ni.com. Electromagnetic Compatibility CE, C-Tick, and FCC Part 15 (Class A) Compliant Emissions...EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity...EN 61326:1997 + A2:2001, Table 1 Note For EMC compliance, you must operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows: Low-Voltage Directive (safety)...73/23/eec Electromagnetic Compatibility Directive (EMC)...89/336/EEC Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, click Declarations of Conformity Information at ni.com/hardref.nsf/. BNC-2121 Connector Accessory for 660X Devices 16 ni.com

Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com. Worldwide Support National Instruments has offices located around the world to help address your support needs. You can access our branch office Web sites from the Worldwide Offices section of ni.com. Branch office Web sites provide up-to-date contact information, support phone numbers, email addresses, and current events. If you have searched the technical support resources on our Web site and still cannot find the answers you need, contact your local office or National Instruments corporate. For telephone support in the United States, dial 512 795 8248. For telephone support outside the United States, contact your local branch office: Australia1800300800, Austria4306624579900, Belgium32027570020, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, CzechRepublic420224235774, Denmark4545762600, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, Israel972036393737, Italy3902413091, Japan81354722970, Korea 82 02 3451 3400, Malaysia 603 9131 0918, Mexico 001 800 010 0793, Netherlands 31 0 348 433 466, New Zealand 1800 300 800, Norway 47 0 66 90 76 60, Poland 48 0 22 3390 150, Portugal 351 210 311 210, Russia 7 095 238 7139, Singapore 65 6226 5886, Slovenia 386 3 425 4200, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 0 8 587 895 00, Switzerland 41 56 200 51 51, Taiwan 886 2 2528 7227, Thailand 662 992 7519, United Kingdom 44 0 1635 523545 National Instruments Corporation 17 BNC-2121 Connector Accessory for 660X Devices

CVI, LabVIEW, Measurement Studio, National Instruments, NI, ni.com, and NI-DAQ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2001 2003 National Instruments Corp. All rights reserved. *322640C-01* 322640C-01 Jun03